Loading…
Loading…
Tender ID
Tender Value
₹55.8 Cr
EMD Value
₹1.1 Cr
Closing Date
25 Mar 2026, 3:00 pmClosed
EXECUTIVE ENGINEER
Narwana PHED
UJHANA AUGMENTATION OF WATER SUPPLY SCHEME IN VILLAGE. UJHANA MAHAGRAM DISTT JIND UJHANA PROVIDING SEWERAGE SCHEME IN VILLAGE UJHANA SWARN JAYANTI MAHAGRAM YOJNA DISTT JIND UJHANA PROVIDING SEWERAGE SCHEME IN VILLAGE UJHANA SWARN JAYA
2026_HRY_505855_1
202681904108 97DB 42D4 B5C2 862520A0CED1570PUH
Open Tender
Civil Works
Works
755 days
UJHANA UJHANA UJHANA
4 documents required · 4 mandatory
₹20,000
₹1.1 Cr
Yes
O/o SE PHE Circle Jind
13 Mar 2026
3 Mar 2026
25 Mar 2026
3 Mar 2026
25 Mar 2026
3 Mar 2026
13 Mar 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: EE PHED Narwana
Name of Work UJHANA:- AUGMENTATION OF WATER SUPPLY SCHEME AND SEWERAGE SCHEME IN VILLAGE. UJHANA (MAHAGRAM) DISTT. JIND.” Construction of independent canal based water works No.2, Construction of Structures at existing Water Works No.1 and 3 nos boosting station, Strengthening of distribution system, laying of Sewerage Network, Restoration of streets, Construction of 2.50 MLD STP, Construction of 2 nos. Intermediate Pumping Station, Main Pumping Station, Treated Effluent rising main and Operation and maintenance for 6 year Defect liability cum maintenance period (after 3month trial run) as per letter issued by the project director HEWP vide memo no. 11296-11352 PHE/HEWP dated 10/02/2026. and all other works contingent thereto.”
Contract No: 01684-298555
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description NS Item Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1.1 Providing and fixing of 300 mm Zero velocity valve IVC/VAG/Kirloskar make of PN 1.6 rating, including, carriage, loading and unloading and fixing, complete in all respect for the satisfaction of the Engineer-in-Charge . 1 No. Excess(+) Full Conversion INR
1.2 Supply and fixing of chain pulley block of 5 ton capacity including cost of steel wire, chain full length etc. complete in all respect including cost of 2.50 mter. high piller, Gantry garderwith moving swivel arm of suitable length for lifting pumps from the sump to the ground level with paltform and complete in all respect. 1 Each Excess(+) Full Conversion INR
1.3 Construction of Water proof Shed for Transformer and DG set of required size with MS railing including material ISI make complete in all respect. 1 Each Excess(+) Full Conversion INR
1.4 Supplying, erection, testing and commissioning of Horizontal submersible open well pumping set of raw water having head 12.00 m as requirements of discharge in 1600 LPM and power capacity in 10.00BHP as ISI Marked 2 Each Excess(+) Full Conversion INR
1.5 Design construction, testing and commissioning of 2.50 MLD capacity Water Treatment Plant including inlet channel, Alum dozing Flash mixing, Clarifloculator, filter box, over head Reservoir for back wash, waste water tank including all civil work, Pumping machineries and electric cabling. Control panels entire piping network of suitable size, laying the DI pipe from raw water pump to inlet box of WTP, WTP to CWT. and Suction Well for CW including DI specials, suitable size Sluice valves, Hodies, manhole covers, air scour equipment, chemical house include chlorination equipment and arrangement of flow measurement and sand bed complete in all respects as per NIT (BASED ON SCADA SYSTEM- 2.50 MLD) 2 Job Excess(+) Full Conversion INR
1.6 Construction of HT/LT Panel room, PLC room, Centrifuge house, blower room and Lab cum office building including doors, window and fitting with toilet block including sanitary fittings STP site covered area with RCC framed structure of brick work vitrified glaze tiles flooring, powder coated aluminum frame of size 100mm x 45mm of 10 gauge for chowkhat frame, 75mm x 45mm of 10 gauge for door frame, 45mm x 45mm of 10 gauge for window frame, 5mm thick glass AIS/Saint Gobin/Modi Float, covered area 1 sqm. 300 Sqm. Excess(+) Full Conversion INR
1.7 Supply of electrically driven vacuume pump ( Suitable capacity) of ISI make along with glass, reflector, GI pipe fitting, gate valve, base coupling and other acessoseries complete in all respect. 1 Each Excess(+) Full Conversion INR
1.8 Design, Supply and erection of transformer of HT metering pannel of standard make required rating indoor type 11 KVA VCB Pannel with entire cable network from GO switch to HT Metering and HT metering ot transformer complete in all respect. 1 Each Excess(+) Full Conversion INR
1.9 Providing and fixing LT panel board suitable for 3 phase for wire AC supply with Bus Bar for running of 5 No. electric motor of 10 BHP to 35 BHP with complete in all accessories. 2 Each Excess(+) Full Conversion INR
2 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- (Suitable for 2 no. 10.00 BHP RAW water induction Motor) `a) Main switch 63 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 100/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 63 Amp. = 1 No. each ` 2 Each Excess(+) Full Conversion INR
2.1 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 2 no. 50.00 BHP clear water induction Motor ) (a) Main switch 150 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 100/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 150 Amp. = 1 No. each 2 Each Excess(+) Full Conversion INR
2.2 Supply, Installation, testing, Commissioning with one year warranty Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus. Line Size 200mm, installed at Pump End/Source 2 Each Excess(+) Full Conversion INR
2.3 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- (Suitable for 2 no. 15.00 BHP clear water induction Motor ) (a) Main switch 63 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 100/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 63 Amp. = 1 No. each 1 Each Excess(+) Full Conversion INR
2.4 Less credit of Old Bricks bats...... 270 Cum Less(-) Full Conversion INR
2.5 credit of old bricks 194400 No. Less(-) Full Conversion INR
2.6 Providing and fixing clear water pumping machinery 4000 LPM x 35 M Head for filling 3 No Boosting station 1,2 and 3..... 2 Job Excess(+) Full Conversion INR
2.7 credit of old steel 5766 Kg. Less(-) Full Conversion INR
2.8 Supplying, erection, testing and commissioning or Horizontal motor pumping set of Raw water having head 12.00 m as requirements of discharge in 1600 LPM and power capacity in 7.50 BHP as ISI Marked Raw water 1600 LPM x 7.50 BHP x 12m head at ww 2 Each Excess(+) Full Conversion INR
2.9 Supply,fixing testing and commissioning of C.I. Sluice Gate of Size 600x600 mm with all accessories of ISI make complete in all respect 1 One Unit Excess(+) Full Conversion INR
3 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 2 no. 20.00 BHP Clear water induction Motor ) a) Main switch 100 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 200/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 100 Amp. = 1 No. each 1 Each Excess(+) Full Conversion INR
3.1 Providing and Fixing PVC insulated 10 sq. mm copper wire 3.50 core ISI mark for connection of Induction motor including thimble and jointing complete in all respect. 400 Per Mtr. Excess(+) Full Conversion INR
3.2 Providing and Fixing PVC insulated 16 sq. mm copper wire 3.50 core ISI mark for connection of Induction motor including thimble and jointing complete in all respect. 360 Per Mtr. Excess(+) Full Conversion INR
3.3 Crossing of National Highway 352 with 450 mm i/d HDPE Pipe with trenchless method with material and labour complete in all respect as required at site… 60 Per Mtr. Excess(+) Full Conversion INR
3.4 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 2 no. 20.00 BHP RAW water induction Motor ) `a) Main switch 63 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 100/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 63 Amp. = 1 No. each ` 1 Each Excess(+) Full Conversion INR
3.5 Credit of old Pumping machinery Supplying, erection, testing and commissioning of Horizontal motor pumping set of raw water having head 12.50 m as requirements of discharge in 1500 LPM and power capacity in 7.5.BHP as ISI Marked 2 Each Less(-) Full Conversion INR
3.6 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 2 no. 7.5 BHP RAW water induction Motor ) `a) Main switch 63 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 100/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 63 Amp. = 1 No. each ` 2 Each Excess(+) Full Conversion INR
3.7 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 2 no. 35.00 BHP clear water induction Motor ) `a) Main switch 150 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 100/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 150 Amp. = 1 No. each` 1 Each Excess(+) Full Conversion INR
3.8 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 2 no. 15.00 BHP clear water induction Motor ) (a) Main switch 150 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 100/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 2 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 150 Amp. = 1 No. each 2 Each Excess(+) Full Conversion INR
3.9 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 1 no. 30.00 BHP clear water induction Motor ) at Water Works no.1 for filling Boosting Stations `a) Main switch 100 Amp.1 Nos.. (L and T Siemens, ABB). (b) CT 100/5 Nos. (AE/KAPPA/ LandT) (c) Digital Multi Function meter = 2 no. (d) SPP 1 No. of approved make (e) Motor starter, star delta 1 Nos. (LandT Simens, AAB) (f) VSS 1 No. and ASS 1 No. of approved make (g) Capacity KVAR as per site requirement = 2 No. (h) Indicating Lamp-One Set (i) Change over switch 100 Amp. = 1 No. each ` 2 Each Excess(+) Full Conversion INR
4 Providing and laying of 250 mm i/d D.I pipe through 400 mm M.S casing pipe under NH-352 by trenchless method complete as per N.H. specification including cost of material, labour and all other safety measures required during execution of work. 60 Per Mtr. Excess(+) Full Conversion INR
4.1 Providing and laying of 300 mm i/d D.I pipe through 450 mm M.S casing pipe under NH-352 by trenchless method complete as per N.H. specification including cost of material, labour and all other safety measures required during execution of work. 60 Per Mtr. Excess(+) Full Conversion INR
4.2 Laying of 450 mm o/d HDPE Pipe through Prov. and fixing 600 mm M.S. casing Pipe under NH-352 by trenchless method complete as per N.H. specification including cost of material, labour and all other safety measures required during execution of work. 60 Mtr. Excess(+) Full Conversion INR
4.3 Laying of 315 mm o/d HDPE Pipe through prov.and fixing 450 mm M.S. casing Pipe under NH-352 by trenchless method complete as per N.H. specification including cost of material, labour and all other safety measures required during execution of work. 60 Mtr. Excess(+) Full Conversion INR
4.4 Supply ,erection testing and commissioning of Horizontal motor pumping set of raw water having head 60.00 m as requirements of discharge 4200 LPM and power capacity 100.00 BHP as ISI Marked 3 Nos. Excess(+) Full Conversion INR
4.5 Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 1500 mm and 400 mm deep having following accessories:- ( Suitable for 3 no. 100.00 BHP) 3 Each Excess(+) Full Conversion INR
4.6 “Design, construction, erection, testing and commissioning of 2.50 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including, Landscaping, MCC Panel Room and all other contingent Electrical, Mechanical, Electromagnetic Flow Measurement Device on inlet and outlet, Real Time water quality monitoring with Data collection system (Online analyzer) Piping and Instrumentation works with PLC and SCADA Arrangement for STP along with Synchronizing it with each other including furniture and laboratory equipments as per detail given in the bid document and including following components. 1 Each Excess(+) Full Conversion INR
4.7 NS Item -MAIN PUMPING STATIONS 2.50 MLD Design, construction, erection, testing and commissioning of MPS and following components.RCC Inlet chamber, Screen Chamber, rectangular collecting tank suitable size for 2.50 MLD average flow with peak factor of 3.00, landscaping of the campus providing and installing of 5 No. Pumping Set of i.e.1 no.5300 LPM (312.5 cum per hour), 2 no. 1800 LPM (104.17 Cum per hour) and 2 no. 900 LPM (52.08 Cum per hour) with 35 mtr. Head each suitable LT panel equipped with all safety devices, automatic capacitor bank and submersible cable form LT panel to pump sets complete in all respect..K9 DI pipe of suitable dia at MPS including welding and screwing of flanges, ISI marked D.I. fittings, Sluice valves, Flow measurement devices as per requirements complete in all respect.3 Nos. CI Gear Operated Sluice Gate with SS Spindle (SS 410) and seats (SS 304) (2 nos. for screen and 1 no. for partition of collecting tank) as per design. Supply and installation of 2 Nos. mechanical course screens of minimum length 6 mtr for 2.50 MLD average flow with peak factor of 3.0:-i) The connecting sewer of same diameter and material of construction, laid at adequate depth between existing sewers to newly constructed structures is included in this scope of work.ii) All the infrastructure except construction of staff quarter, and path ways/ roads required to be executed at site to make the MPS functional is included in the scope of work for lump-sump job.iii) All the pumping machinery, panel board, Level sensor etc shall be controlled by PLC and SCADA and shall be synchronized with PLC panels at MPS site through broadband internet facility. Providing and Installing CCTV 2 Cameras for MPS complete as per satisfaction of the Engineer– in- Charge, within 96 hours of signing the Agreement along with 90 days recording (DVR), 32 inch LED Screen, 16 Channel DVR at STP Site and 8 Channel DVR at MPS Site with connectors, cables, poles and power supply with online real-time output facility. The cameras at MPS shall be synchronized at MPS site. Make: - CP Plus Internet Protocol minimum 5 MP WDR, Night vision color mode 2.4.2 12 mm very focal with extra IR, CCTV Cameras should be installed and commissioned before starting execution of work.....1 1 Each Excess(+) Full Conversion INR
4.8 Operation and maintenance of 2 No. water treatment plant 2.50 MLD capacity (1 No. constructed at w/w No.1 and other 1 is at w/w No.2), construction of 2 No. intermediate pumping station, sewerage treatment plant (2.50 MLD), Main pumping station, treated effluent rising main and sewerage network for 6 year Defect liability cum maintenance period (after 3month trial run) as per letter issued by the project director HEWP vide memo no. 11296-11352 PHE/HEWP dated 10/02/2026. (Operation and maintenance will be charged to the A/mtc. Estimate) complete in all respect as per approved NIT. 1 Job Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: EE PHED Narwana
Name of Work UJHANA:- AUGMENTATION OF WATER SUPPLY SCHEME AND SEWERAGE SCHEME IN VILLAGE. UJHANA (MAHAGRAM) DISTT. JIND.” Construction of independent canal based water works No.2, Construction of Structures at existing Water Works No.1 and 3 nos boosting station, Strengthening of distribution system, laying of Sewerage Network, Restoration of streets, Construction of 2.50 MLD STP, Construction of 2 nos. Intermediate Pumping Station, Main Pumping Station, Treated Effluent rising main and Operation and maintenance for 6 year Defect liability cum maintenance period (after 3month trial run) as per letter issued by the project director HEWP vide memo no. 11296-11352 PHE/HEWP dated 10/02/2026. and all other works contingent thereto.”
Contract No: 01684-298555
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Item Description HSR Item BI01010001010000000000000515BI0100001112
1.1 UJHANA:- AUGMENTATION OF WATER SUPPLY SCHEME AND SEWERAGE SCHEME IN VILLAGE. UJHANA (MAHAGRAM) DISTT. JIND.” Construction of independent canal based water works No.2, Construction of Structures at existing Water Works No.1 and 3 nos boosting station, Strengthening of distribution system, laying of Sewerage Network, Restoration of streets, Construction of 2.50 MLD STP, Construction of 2 nos. Intermediate Pumping Station, Main Pumping Station, Treated Effluent rising main and Operation and maintenance for 6 year Defect liability cum maintenance period (after 3month trial run) as per letter issued by the project director HEWP vide memo no. 11296-11352 PHE/HEWP dated 10/02/2026. and all other works contingent thereto.” BI01010001010000000000000515BI0100001113 0.000 Nos 373923409.4 Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.83 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.67 MB
BOQ_584581.xls
BOQ • 0.33 MB
1F4BOQZ132780.pdf
Additional Documents • 19.52 MB
Corrigendum.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .