Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹24.8 L+₹2.0 L (8.78%)Rejected-Finance 2284 30 BAJRANG NAGAR VFJ ESTATE JABALPUR 482009 | JABALPUR | MADHYA PRADESH | 482009 | L2 | Rejected-Finance Over all rates are higher than L1. | |
| 3 | L3₹25.5 L+₹2.7 L (11.7%)Rejected-Finance 0 SALEHPUR KOTLA BSR ROAD PO DAHANA HAPUR HAPUR UTTAR PRADESH 245101 | HAPUR | UTTAR PRADESH | 245101 | L3 | Rejected-Finance Over all rates are higher than L1. | |
| 4 | L4₹27.3 L+₹4.5 L (19.7%)Rejected-Finance 210 C RAM DASS KA HATA SADAR CANTT LUCKNOW UP PIN 226002 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226002 | L4 | Rejected-Finance Over all rates are higher than L1. | |
| 5 | L5₹27.4 L+₹4.6 L (20.1%)Rejected-Finance | L5 | Rejected-Finance Over all rates are higher than L1. |
Tender Value
Refer Docs
EMD Value
₹57,700
Closing Date
22 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Bareilly
CWE (AF) Bareilly
SPECIAL REPAIR TO LABS AT AF STATION BKT
2021_MES_423793_1
SPL REP TO LAB AT BKT
Open Tender
Civil Works
Item Rate
120 days
BKT
As per NIT
8 documents required · 8 mandatory
₹500
GE(AF) BKT
₹57,700
Yes
31 Mar 2021
19 Feb 2021
24 Mar 2021
19 Feb 2021
22 Mar 2021
9 Mar 2021
20 Feb 2021 - 1 Mar 2021
60 days
Amount
M&L for aluminium powder coated door frame and shutter including top, bottom/middle rail using glazing clip including rubber head and glass 6mm thick tinted provided with one floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty fixed to aluminium door and other fittings like handle, locking system, push plate and necessary beading all around the door shutter frame as required for resistance complete all as specified and directed and as per Chief Engineer (AF) Allahabad Drg No CE/ALD/TD-224 Sh 1/1 dated 17 Oct 2012.
M&L for aluminium powder coated sliding window, ventilator three track including aluminium powder coated decorated grill sliding shutter 5mm thick tinted float glasses, necessary aluminium beadings fittings and other panels to prevent air from out side complete all as specified and directed and as per Chief Engineer (AF) Allahabad Drg No CE/ALD/TD-194 Sh 1/2(R) dated 29 Feb 2012 and revised upto 01 Aug 2012 and Sh 2/2 dated 29 Feb 2012.
M&L for aluminium powder coated partition using aluminium sections fitted with 5mm thick tinted glass in upper portion from 3' height as required as per site and 12 mm thick prelaminated particle board both side of standard quality of approved make, any type upto 3' height as required as per site from bottom using glazing clips including jointing cleat for fixing glazing clips, rubber packing anodised aluminium beading etc aluminium tower bolt, floor stoper and locking arrangement by providing latch lock of standard quality of approved make complete all as specified and directed and as per CE(AF) Allahabad Drg No CE/ALD/TD-224 Sh 1/1 dated 17 Oct 2012.
Demolition of cement concrete (un-reinforced) including APP membrane any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for water proofing treatment by providing 90-100 micron thick polymeric water proofing membrance over levelling coarse on non-approachable roof (where required) complete all as mentioned below as specified. (i) Average 10mm thick plaster in CM 1:3 mixed with polymer based water proofing compound when levelling coarse is still green. (ii) After the surface is fully dried, it shall be cleaned free from dust and shall be painted with a coat of bituminous primer @ 0.30 ltrs/Sqm. (iii) After primer, the entire roof surface shall be applied with hot, blown bitumen grade 85/25 confirming to IS-702 @ 1.2 Kg/Sqm. (iv) Over hot bitumen polymeric water proofing membrance consisting of 90 to 100 micron thick central core HMHDPE film and standard weight not less than 3 Kg/Sqm shall be laid with 100mm side lap/end lap on prepared surfaces as per manufacturere's instruction and strict supervision of manufacturer's technical representative including as required on verticle surface in parapet. (v) Laying 40mm thick brick tiles, laid over a bedding layer 20 mm thick in CM 1:4. The cement mortar screed shall be mixed with polymer based liquid water proofing additive @ 5% by weight of cement as per manufacturer's specition/instruction and tile joints shall be filled with polymer based cement proof joint filler manufactured by approved specification/instructions and tiles joints shall be filled with 1:3 CM mixed with crude oil as per SSR-2009 (Part-1) complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 (20mm graded agg) as in benching , haunching kerb etc rounded or chamfered on edges incl necessary formwork complete all as specified and directed
M&L for cement concrete (1:2:4) type B0 using (12.5mm graded aggregate) in roof for leveling course complete all as specified and directed
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed.
M & L for brick work with old size sub class 'B' bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for 15 mm thick rendering on any faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M & L for 15 mm thick rendering on brick work or concrete surfaces with cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3, on concrete surfaces fiished even and smooth without using extra cement as in ceiling complete all as specified and directed.
M&L for applying two coats of oil bound distemper over a coat of primer over Birla white wall putty after complete removal of existing treatment on old plastered surface including necessary preparation complete all as specified and directed
M&L for applying two coats of oil bound distemper over a coat of primer over Birla white wall putty on new plastered surface including necessary preparation complete all as specified and directed
M&L for applying two coats of oil bound distemper on ceiling surface of ceiling board Gypsum including ncessary preparation including taking down and refixing of gypsum board complete all as specified and directed
M&L preparation of new plastered surfaces of walls and applying two coats of wheather proof exterior emulsion paint over a coat of alkali resistant priming paint in comouflage pattern of thee or more colors as approved complete all as specified and directed
M&L for complete removal of existing treatment and preparation of old plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant priming paint in comouflage pattern of thee or more colors as approved complete all as specified and directed
M&L for three coats of white wash on newly plastered surfaces of ceiling including preparation to surfaces complete all as specified and directed .
M&L for preparation of old steel surfaces of any description, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for Preparation of old wooden or wood based surfaces of any description, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed..
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs, any thickness, including cover fillets complete all as specified and directed.
S&F false ceiling aluminium snap grid type with hot dipped pre-coated sections & 12mm thick perforated /semi perforated panels of grid size 60cmx60cm Make : India Gypsum, Armstrong with following aluminium sections for frame work:- (a) Wall side angle 24x24x0.43mm (b) Main tee 24x35x0.35mm (c) Cross tee 24x25x0.30mm having integral splices at both ends for interlocking complete with suitable hanging arrangements of metalic fastners, holding cleats GI wire suspenders etc complete including two coats of oil bound distemper complete all as specified and directed
S&F 12 mm thick Perforated particle boards or tiles for insulation and accoustic purposes, 60cm x 60cm size fixed with screw or as per manufacturers instructions. Complete all as per specified and directed
S & F door closer hydraulically regulated, aluminium (die cast) designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for dark shade Coloured Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed
M&L for dark shade Coloured Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm in dado/ skirting etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
Dismantling of boarding, any description and fixed in any position with nails complete all as specified and directed.
S & F for 2nd class hard wood (SAL) scantling, wrought in any position and any description as in framed work complete all as specified and directed.
Fixing only 2nd class hard wood (SAL) scantling (Except timber), wrought in any position and any description as in framed work complete all as specified and directed.
S & F for 20 mm thick weather boarding (Eaves board ), clean sawn, plain II nd class hard wood fixed with 30 mm laps with nail complete all as specified and directed
M&L for preparing surfaces of wood & wood based materials new or old of any description & girth not otherwise described & treated with creosite oil complete all as specified and as directed
Dismantling of plain or corrugated steel sheeting / galvalume aluminum sheeting, any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and directed.
S&F Pre-painted Trapezoidal profile galvalume or Zincalume profiled coloured coated steel sheet 0.63 mm total thickness (with coating and painting) of approved colour as in roof covering/cladding, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap whereever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided whereever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : (i) The colour of sheet for bldg shall be approved by GE. (ii) Sheeting shall be fixed of any height. Make : Tata Blue Scope/Jindal
All as per item No. 36 above but fixing only.
Taking down and refixing in same opening aluminum door shutter of area exc 1.00 sqm but n exc 2.00 sqm including necessary repair complete all as specified and directed
S&F in repair PVC water tank covers with hinges and locking device for tank capacity of 500 liters complete all as specified and directed.
Taking down aluminum glazed shutter from frames for servicing / replacement of broken pivots , rubber beads etc, complete & refixing in the same opening after repair. The servicing shall include oiling of hydraulic door closer / floor door spring tightening / refixing of handles, tightening of joints of rail and styles etc and opening of pivot plate and replacement and refixing to obtain smooth opening and closing complete all as specified and directed. Note :- Aluminium members, glass, handles , hydroulic door closer, floor spring shall only be paid for separatly under respective items
Taking down aluminum door frame in any size and length as per existing glass door/approved including taking out glazed shutter from frames and refixing in the same opening after servicing / replacement of broken pivots etc and making good to obtain smooth oening and closing. complete all as specified and directed Note :- Aluminium members shall only be paid for separatly under respective items
S & F in repair vitreous china wash down water closet pan (Pedestal pattern) white excluding fixing bolts, flushing cistern and flush pipe complete all as specified and directed.
S & F in repair plastic seat cover suitable for water closet pedestal pan, coloured closed pattern with flat bottom and cover and mid steel chromium plated or aluminium hinges devices complete all as specified and directed.
Taking down existing PVC low level flushing cistern including bend, flush pipes etc and M&L for providing 10 Ltrs capacity PVC low level flushing cistern including chromium plated brass inlet and outlet connections, brackets, PVC flush pipe with bend 32 mm dia of suitable length incl making necessary connections to water supply pipe line jointing to WC all as specified and directed.
S & F in repair water closet vitreous china squatting pan ‘Orissa’ pattern size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, anti-syphonic pipe etc. including lean concrete as required complete all as specified and directed.
S & F in repairs vitreous china coloured wash basin, oval shaped, nearest size 550 X 400 mm, fixed over counter, excluding taps, waste, chain and plug but including brackets, waste pipe, waste coupling, cutting for and pinning in as required complete all as specified and directed.
S & F in repair 15 mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'HOT' or 'COLD’ with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S&F in repair vitreous china urinal, half stall pattern (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinals back in cement ,fixing automatic flushing cistern with brackets, flush pipe, grating amd union for discharge pipe, (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) and PTMT spreader complete all as specified and directed
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
M&L 50mm thick PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in plinth protection without using extra cement complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) pipes (IS 13592-1992 type A) single socketed , in any length with rubber ring joints conforming to IS-5382 fixed to walls with SS clamps laid in trenches or in floors complete all as specified and directed.
S&F for PVC (SWR) bends with access door any radius of bore 110 mm complete all as specified and directed.
S & F mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe – 290 Grade – E 165 complete all as specified and directed.
Taking down carefully Aluminium/ Copper point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, lamp holder, regulator, switch socket outlet, light fittings, shade conical etc and separating serviceable fittings & fixtures for re-use in the work as directed including removing of unserviceable fittings & fixtures with wiring cable, existing conduits etc from site and making good disturbed surfaces of walls, floors, ceiling etc complete all as specified and as directed.
Taking down old and unserviceable sub main wiring any size / type / core incl earth wire complete with batten/conduit etc and making good the disturbed surface to match the existing disturbed surface all as directed by Engr-in-charg.
Taking down old and unsrevicable sheet metal enclosure , switch fuse unit, distribution bord any type /way / capacity including fuses, MCB's, insulator etc complete after removing all connection and making good the disturbed surface complete all as specified and directed.
M&L for Point wiring complete with FRLS PVC insulated unsheathed , 1100 V grade conforming to IS 694,1.5 Sqmm (Norminal area) multistranded ,copper conductor cable drawn through in non metallic rigid PVC conduit medium grade not less than 20 mm dia concealed in wall / surface of roof / ceilings etc with concealed sunk in pressed steel terminal boxes of required size , thickness not less than 1.6 mm factory made with top cover of hylem sheet 3.0 mm thick, with brass screw and cup wachers and including FRLS PVC insulated unsheathed 1.5 Sqmm muilti stranded green colour copper conductor cable single core as earth continuity conductor and connecting to common earth dolly & drawn in same conduit complete all as specified and directed .
(a) One light point controlled by one, one way switch
(b) One Ceiling / exhaust fan point controlled by one, one way switch
(c) One 3 pin swicth socket outlet, 5/6 amps, on independent board
(d) One 3 pin switch socket outlet, 5/6 amps, on same board
All as per item No. 58 above but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete outlet on independent board including single core 2.5 Sqmm FRLS insulated unseathed cabledrawn on same conduit as earth wire and common earth and connecting to earth dolly as specified. Note for BOQ Item No 58 & 59 Cost of cutting/ chasing for conduits and making good disturbed surface deemed to be included in unit rate.
S&F switch piano flush type single pole one way , 5 Amps , 230V grade ISI marked complete all as specified and directed.
S&F switch piano flush type single pole one way , 15 Amps , 230V grade ISI marked complete all as specified and directed.
S&F socket outlet 2 in 1 , 3 pin 5 Amps flush type ISI marked complete all as specified and directed.
S&F socket outlet 2 in 1 , 3 pin 5 &15 Amps flush type ISI marked complete all as specified and directed.
S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete all as specified and directed.
Taking down old U/S flame proof light fitting from its existing position and S&F of CMRI certified LED flame proof 1x18/20W LED tube light fixture with recommended for Gas /Vapor group of IIA & IIB and zone 1 & IP 65 protection etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in repair wall / surface mounted type LED light fitting batten type complete with LED lamp 1 x 20 Watt (4 feet long), extruded aluminium heat sink provide for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper conductor cable complete all as specified and directed.
S&F in repair full glow fully diffused recessed mounting LED light fitting 2' x 2', 36 watts with diffused acrylic cover complete with all accessories and making connection by using suitable length of three core flexible copper of size 0.50 Sqmm complete all as specified and directed.
Supply & fixing of electronic step type fan regulator of flush type on the existing hylem sheet complete all as specified and directed.
M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor FRLS cable of size 4 Sqmm 1100 Volts grade and one run of PVC insulated unsheathed stranded copper conductor FRLS cable of size 4.0 Sqmm 1100 Volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC conduit of size 25mm dia concealed including making good the disturbed surfaces of wall etc including complete all as pecified and directed. Note :- Cutting/ chasing for conduits shall be measured and paid separately.
M&L for submain wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor FRLS cable of size 6 Sqmm 1100 Volts grade and one run of PVC insulated unsheathed stranded copper conductor FRLS cable of size 6 Sqmm 1100 Volts grade as earth continuity conductor drawn through in and including rigid non metallec PVC conduit of size 25mm dia concealed including making good the disturbed surfaces of wall etc including complete all as directed. Note :- Cutting/ chasing for conduits shall be measured and paid separately.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( single pole and neutral ) 8 way, 240 Volts, sheet metal powder coated with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F MCB SP, 240 volts, 40 Amps breaking capacity 10 KA, ‘C’ Series. etc , complete all as specified and directed. Make :- Legrand, Schneider, Siemens
S&F MCB SP (single pole) 240 volts, 6 - 32 Amps, 50HZ, 10 KA. , ‘C’ series complete all as specified and directed. Make :- Legrand, Schneider, Siemens
S&F for sheet metal enclosures with two pin and earth plug sockets controlled by one No. MCB SP rating 20 Amps , 240 Volts grade, double door type complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used TPN (Triple pole and neutral ) 4 way, 240 Volts, sheet metal, powder coated with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( single pole and neutral ) 12 way, 415 Volts, sheet metal powder coated with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F MCB TPN, 63 Amps, 415 Volts, rupturing capacity 10 KA "C" Series complete all as specified and directed.
S&F MCB SPN, 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete.
S&F angle holder backlite with hylum sheet including 5 Watt LED Bulb complete all as specified and directed.
M&L for earthing complete for machinary / Equipment installed at power house / sub station with copper earth plate electrode of size 60 cmx 60 cmx 3.15 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected with copper strip of size 20X3 mm by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.3 of SSR Part- I connected to main board / disribution board complete .Earthing strip copper 25x3.15 mm and GI protection pipe 32 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete. (ii) Earthing shall be tested as specified in SSR PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S&F rigid non-metalic PVC conduit of size 25 mm inclusive of boxes (junction / terminal) of all tees, bends, elbows, reducers, bell mounth tube ends and fixing accessories such as couplers , lock nuts , saddles , pipe hooks etc complete all as specified and directed.
Shri Krishna Constructions
M/S PRATAP BUILDERS
M/s A S Associates
H C CONSTRUCTION
VINAYAKA (INDIA) MULTIFARIOUS SERVICES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .