Superintending Engineer
SE, EWC Meerut
Onsite Maintenance of Medium Damaged Distribution Transformers under District Saharanpur
2024_PVVNL_953952_1
E-Tender No 22/EWC-MT/2024-25
Open Tender
Electrical Works
Item Rate
365 days
Superintending Engineer EWC Meerut
As Per Tender Document
3 documents required · 3 mandatory
₹1,180
Executive Engineer EWD
₹7,000
10 Oct 2024
7 Sept 2024
25 Sept 2024
7 Sept 2024
25 Sept 2024
7 Sept 2024
Removing Top Cover Plate by opening of Bolt and nuts of T/F and other internal connection of T/F required for repairing safely and reconnect it after aproprately after Minor repairing work of Medium Power Distribution Transformer(11/0.4 KV) installed at various site for Stoping Oil leakage from T/F, Replacement of Damaged H.T/L.T Bushing Rod and other work as per site requirment & site conditions. Firm has to make arrangement for draining and refilling of T/F Oil , if required for carring out the work. (Distance of 75 Km. from concerned CTR)
250 KVA, 400 KVA T/F
630 KVA, 750/800 KVA, 1000 KVA T/F
Toping Up/Filling of Reclained T/F Oil in T/F's Toping Up/Filling of reclaimed T/F Oil in following capacity of T/F's upto 2/3rd level of conservator Tank for Distribution T/F having less Oil as per Indent placed for repairing by Distribution Wing. Filling up of these T/F by Reclaimed T/F Oil upto required level and carriage of reclaimed T/F Oil, T/F drums from concerned CTR including safe loading and unloading at both ends. Complete in all respect as per site requirement( Reclaimed T/F Oil will be provided by the concerned JE(W/S) ( Required Vehcile & suitable Container for storage of Reclaimed T/F Oill will be arranged by the Contractor at his own cost.
Replacement of Old and Damaged H.T Busihing rod including Oil Seal/Gaskits etc.(250 KVA, 400 KVA, 630 KVA, 750/800 KVA, 1000 KVA T/F) Removal of Old and damaged H.T Busing Rod from T/F and fixing of suitable size new H.T Busing rod made of Brass with all nuts and bolts etc. including replacement of all old/damaged Neoprene Oil seal/Gasket set by fixing suitable size New Neoprene Oil Seal/Gasket Set & as per site requirment, Complete Job in all respect. ( All material will be provided by the Department)
Replacement of Old and Damaged L.T Busihing rod including Oil Seal/Gaskits etc. 250 KVA, 400 KVA, 630 KVA, 750/800 KVA, 1000 KVA T/F) Removal of Old and damaged L.T Busing Rod from T/F and fixing of suitable size new L.T Busing rod made of Brass with all nuts and bolts ect. including replacement of all old/damaged Neoprene Oil seal/Gasket set by fixing suitable size New Neoprene Oil Seal/Gasket Set & as per site requirment, Complete Job in all respect. ( All material will be provided by the Department)
Stopping Oil leakage from T/F H.T/L.T Bushing side. Stopping of Oil leakge from T/F L.T/H.T Side Bushing. Removing of all damged oil Seal/Gasket Set/Cork sheet and fixing of suitable size new Neoprene Oil seal/Gasket set/Cork sheet and tightening of H.T/L.T bushing rod Complete Job in all respect. ( All material will be provided by the Department)
M/S ANAV ELECTRICAL
DURGA ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .