| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹23.2 L+₹3.0 L (14.7%)Admitted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Admitted-Finance | |
| 3 | L3₹25.9 L+₹5.7 L (28.1%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹42.7 L+₹22.4 L (110.9%)Admitted-Finance NOT FOUND | L4 | Admitted-Finance | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to demise of one partner, change in constitution to be uploaded. |
| Sl No | Description | Qty | Unit | A B K Enterprises L1 | SHIV SHANKAR ENTERPRISES L4 | Surjit and Sons L3 | M/S Anand Enterprises L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commissioning LT Timer panel board, out-door type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet ineer of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated , (Note: The Panel shall be mounted on floor with PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above the ground level all as directed by the Engr-in-harge. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item) (Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011,Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 56KA. ( The contractor should submit all Certificates before executing the job.)
Make of panel boards: ADLAC PANEL / TRICOLITE / SHALABH / ADVANCE Make of MCCB & MCB : L&T, ABB, SCHNEIDER & SIEMENS The panel includes following items and rate for below mentioned item shall be included in the quoted rate in this item:- | 26 | Each | 38,000 ₹9,88,000 | 99,000 ₹25,74,000 | 35,000 ₹9,10,000 Lowest | 42,000 ₹10,92,000 |
| 1.01Busbar 4 Pole, Aluminum,150 Amps - 01 Set | |||||||
| 1.0263A, FP. MCCB 25/30 KA, with spreader link - 01 No. | |||||||
| 1.03RYB Indicating Lamp LED type 240 V AC - 03 Nos. | |||||||
| 1.04S&F automatic street light switch panel outdoor Swadeep 02EC12KW3P three-phase outdoor light automation with features like voltage protection and IP54 rating. | |||||||
| 1.054Pole, 63 A (AC1) contactor -01 No. | |||||||
| 1.06MCBSP 6A - 04 Nos. | |||||||
| 1.07ON indicator -01 No. | |||||||
| 1.08Auto mannual switch -01 No. | |||||||
| 1.09OUTGOINGS:- | |||||||
Tender Value
₹25.9 L
EMD Value
₹52,000
Closing Date
30 Jul 2026, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
SPECIAL REPAIR/REPLACEMENT OF ELECTRIC SWITCH AND TIMER SWITCH OF STREET LIGHTS AT AFSSR AND PROVISION OF AUGMENTATION OF THREE PHASE POWER SUPPLY AT SHIPS GALLERY AT INS ARAVALI UNDER GE (AF) GURGAON
2026_MES_776022_1
GE/GUR-/NIT-11/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹52,000
23 Sept 2026
2 Jul 2026
1 Aug 2026
2 Jul 2026
30 Jul 2026
16 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing & commissioning LT Timer panel board, out-door type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, made out of 3 mm thick CRCA sheet outer & 2mm thick CRCA sheet ineer of suitable size to accommodate all accessories / fittings, compartmentalized in costruction to accommodate proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated , (Note: The Panel shall be mounted on floor with PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above the ground level all as directed by the Engr-in-harge. The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item) (Note:- LT Panel board should be as per IS/IEC 61439-I: 2011 & IS/IEC 61439-2 : 2011,Test certificates for Shot Circuit Test, Temperature Rise Test, Di-Electric Property Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 56KA. ( The contractor should submit all Certificates before executing the job.)
Make of panel boards: ADLAC PANEL / TRICOLITE / SHALABH / ADVANCE Make of MCCB & MCB : L&T, ABB, SCHNEIDER & SIEMENS The panel includes following items and rate for below mentioned item shall be included in the quoted rate in this item:- | 26 | Each | - | - |
| 1.01 | Busbar 4 Pole, Aluminum,150 Amps - 01 Set | - | - | - | - |
| 1.02 | 63A, FP. MCCB 25/30 KA, with spreader link - 01 No. | - | - | - | - |
| 1.03 | RYB Indicating Lamp LED type 240 V AC - 03 Nos. | - | - | - | - |
| 1.04 | S&F automatic street light switch panel outdoor Swadeep 02EC12KW3P three-phase outdoor light automation with features like voltage protection and IP54 rating. | - | - | - | - |
| 1.05 | 4Pole, 63 A (AC1) contactor -01 No. | - | - | - | - |
| 1.06 | MCBSP 6A - 04 Nos. | - | - | - | - |
| 1.07 | ON indicator -01 No. | - | - | - | - |
| 1.08 | Auto mannual switch -01 No. | - | - | - | - |
| 1.09 | OUTGOINGS:- | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocuments11.pdf
Tender Documents • 0.42 MB
BOQ_868991.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .