Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.8 LAccepted-AOC INDUSTRIAL AREA A LUDHIANA PUNJAB 141003 | LUDHIANA | PUNJAB | 141003 | 1 | Accepted-AOC Quoted Reasonable rates | |
| 2 | 2₹2.3 L+₹11.6 L (59.9%)Accepted-AOC | 2 | Accepted-AOC Quoted Reasonable rates |
Tender Value
₹19.4 L
EMD Value
₹40,000
Closing Date
14 Oct 2020, 5:00 pmClosed
PRINCIPAL, GOVT. ITI GURUGRAM
GOVT. ITI GURUGRAM, SECTOR 14, GURUGRAM
Supply of Machinery at Govt.ITI, Gurugram
2020_HRY_145203_1
GITI/GGM/Mach./2020/10
Open Tender
Miscellaneous Goods
Supply
45 days
GOVT. ITI GURUGRAM
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Gurgaon Industrial Training Society
₹40,000
9 Dec 2020
22 Sept 2020
15 Oct 2020
22 Sept 2020
14 Oct 2020
22 Sept 2020
Amount
Split phase induction motor Specification : 1Hp,230V
BLDC Motor (1400 r.p.m.), 8 Pole with controller Specification: 15-30 Watts, 315 Volt DC
IDU Pulse Generation type motor Specification : 15watt, 230 volt A.C.
Capacitor start induction motor Specification : 1Hp,230V
AC 3 phase motor, 400/50hz Specification: 2hp
Auto Transformer Starter Specification : 3hp
Oxy- acetylene welding set complete with following accessories :- Specification : 1.Tested & Filled Cylinders of capacity 7 cubic mtrs. of Oxygen and DA with valves & valve keys along with certification certificate of each cylinder (Make- Maruti Kotey, Everest Kanto, British Pipe)-1 No. each (2.) Regulators Double Stage(Make-Asha/ Eshab/IOL)-2 Nos.(3.) Welding torch (Make-Asha/Eshab) with different size nozzles – 1 No. (4.) Hose Pipe, 6 mtr. length for each cylinder with clamps & suitable for W.P. of 4000 PSI -2 Nos. (5.) Cylinder Trolley with wheels for cylinders, made of M.S. frame with paint
Frost free refrigerator carrying with HC blend Specification : 200 L
Core drill machine with diamond core drill bit dia 65 mm. Specification : 220 – 240 Volt, 1500 Watt.
Grinding machine Specification : 200mm,3000rpm,Double ended 1/2hp
Evacuating and refrigerant charging station, consist of a) Rotary two stage vacuum pump and motor (with gas ballast and anti such back). b) manifold with gauges and valves and capable of pulling vacuum up to 50 microns of Hg and with provision of connection to a microns level vacuum gauge. b) Graduated charging cylinder with provision for temperature correction and all necessary isolating valves. Specification : (CAP. 2 kg In lieu of (b) above and with accuracy of +/-1 g for charging hydrocarbons.
Evacuating and charging station as above but fitted with weighing scale Specification: As per above specification (mentioned at Sr. No 11 ) but for charging R 410a refrigerant.
Two stage rotary vacuum pump 4 CFM Specification: capacity approx.60 – 10 rmp capable of evacuating to 50 microns of Hg and fitted with gas ballast, anti Such back valve and single phase motor.
Dry N2 cylinder Specification: Commercial N2 in cylinder with drier unit and 2 stage regulator & meter cube. Cylinder should be tested & certified with certificate.
Window AC Specification : 1 Ton with R-22 blend reciprocating compressor & Remote Control.
Split A.C 1.5 Ton with R134a or R-22 reciprocating compressor Specification : 1.5 Ton with R134a or R-22 reciprocating compressor.
Shell and tube, DX chillers (small) Specifications: 5 ton with valves Cu tubing only.
Shell and tube condenser Specification : 5 Ton
Rotary hermetic compressor Specification : 2 Ton
Bottle cooler visible Specification : 200 L carrying with HFC -134a & reciprocating compressor.
Deep freezer Specification : Single Door, Storage Capacity 200 Ltr. , Temp. range 0 degree C to -20 degree C, carrying with HFC-134a & reciprocating compressor.
Display Cabinet Specification : 2 Ton capacity
Ice candy plant Specification: 2 Ton with capacity to make 32 ice candy at a time with Forma tray, stainless steel tank on trolley.
Air-conditioning, direct system Specification: Air-conditioning, direct system complete with all controls including humidity control capacity 15000 kcal /hr with provisions: - 1. Condenser fins & tube type or forced draft. 2. Cooling coils fin &tube type with three speed fan motor. 3. HP/LP cut out. 4. All electrical control fitted in suitable MS box in such a position that it can be demonstrated perfectly. 5. Digital temp. meter in five sense: - (A)temp. of condenser inlet. (B) temp of condenser outlet. (C)- liquid line to cooling inlet. (D)- suction line outlet of cooling coils (E)- Air temperature ambient. 6. Thermostatic expansion valve of suitable capacity. 7.Digital gases, liquid line indicator, Digital Ampere metre, Volt metre , power metre , mcb etc. should be installed in machine.(Note: -The plant will be put on test for 7 days on site after installation and commissioning).
Air -conditioning indirect system (water cooled) Specification: Air-conditioning, direct system complete with all controls including humidity control capacity 15000 kcal /hr with provisions: - 1. Condenser fins & tube type or forced draft. 2. Cooling coils fin &tube type with three speed fan motor, shell and tube type evaporator 5TR capacity with all safety valves and accessories, make up water tank with 1/2 hp water motor centrifugal pump. 3. HP/LP cut out. 4. All electrical control fitted in suitable MS box in such a position that it can be demonstrated perfectly. 5. Digital temp. meter in five sense: - (A)temp. of condenser inlet. (B) temp of condenser outlet. (C)- liquid line to cooling inlet. (D)- suction line outlet of cooling coils (E)- Air temperature ambient. 6. Thermostatic expansion valve of suitable capacity. 7.Digital gases, liquid line indicator, Digital Ampere metre, Volt metre , power metre , mcb etc. should be installed in machine.(Note: -The plant will be put on test for 7 days on site after installation and commissioning).
Automatic ice cube m/c Specification : 50Kg/24 Hour
Storage type water cooler (hot and cold)Specification : Hot and cold type 80-120 LTR
Visi cooler Specification : Single Door, Temp. Range- 1 degree C to 10 degree C, 185 Ltr. Storage capacity.
VRF/VRV unit Specification : With two indoor unit 2.5 TR cassette type each and 5 TR/6hp capacity outdoor unit complete with air cooled condenser, accessories & control and installation with Cu piping & wire minimum length 40 meter.
Walk in cooler PUF insulated for cold room 6x4.5x8 cft. (complete set) Specification: Temperature 0 degree Celsius to 5 degree Celsius.
Absorption system Specification : Small size
VIJAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .