| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹17.0 L+₹2.1 L (14.3%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹22.5 L+₹7.6 L (51.3%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
1 Oct 2020, 6:00 pmClosed
GE BHOPAL
GE Bhopal, Bairagarh, Bhopal
REPAIR MAINT OF CEILING FANS EXHAUST FANS WALL MOUNTED FANS SOLAR WATER HEATERS AND MISC EM WORKS AT BAIARAGARH UNDER GE BHOPAL
2020_MES_374837_1
8714/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
BHOPAL
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹40,000
Yes
2 Dec 2020
4 Sept 2020
3 Oct 2020
4 Sept 2020
1 Oct 2020
18 Sept 2020
Amount
NOTE: - (i) The quoted rate deems to include for all minor expenses required for making the complaint functional. (ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the AGE E/M Bairagarh subdivision in present of concern JE E/M. (iii) Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. (iv) Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it, and intimate the defects in the fan to JE E/M before carring out the repairs. (v) The bearing of fan should be of NBC/SKF/FAG make only. No other make will be accepted.
Taking down old ceiling fan/Exhaust fans/Wall mounting fan of any cap/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismantlling of fan, carried out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed. NOTE:- (i) Burnt out fan shall be kept separately for rewinding which shall be measured and paid seperately under appropriate item of BOQ. (ii) The quoted rates is deemed to include for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as "Supply only". (iii) Painting of fan shall be on requirement basis and shall be measured and paid for separately under appropriate item of BOQ.
Supply only the following items for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed.
Bearing No 6201 [Make : SKF/NBC/FAG] .
Bearing No 6202 [Make : SKF/NBC/FAG] .
Bearing No 6203 [Make : SKF/NBC/FAG] .
Bearing No 6204 [Make : SKF/NBC/FAG] .
Rubber Bush as required at site suitable for ceiling fan .
Condenser 2.5 mfd [Make: Epcos/Tibcon].
Condenser 4 mfd [Make: Epcos/Tibcon].
Lath work of Fan shaft any type/ size
M&L for rewinding of ceiling fan of sweep 1200 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing, testing etc complete all as specified and directed.
M&L for rewinding of ceiling fan of sweep 1400 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing, testing etc complete all as specified and directed.
M&L for rewinding of ceiling fan of sweep 1200 mm (old model, Heavy duty of make Kessal/ Usha/ Polar or any other make) with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing, testing etc complete all as specified and directed.
M&L for rewinding of Exhaust fan of 450 mm any make any model,1400 RPM with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing, testing, etc. complete all as specified and directed.
M&L for rewinding of Exhaust fan of 380 mmm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing, testing etc complete all as specified and directed.
M&L for rewinding of Exhaust fan of 280/300 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing, testing etc complete all as specified and directed.
M&L for rewinding of wall mounting fan of sweep 400 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing, testing etc complete all as specified and directed.
M&L for rewinding of pedestal fan of sweep 400 mm any make any model with suitable gauge copper winding wire (super enamelled) including all insulating material including necessary heat varnishing, testing etc complete all as specified and directed.
S&F in repairs blade assembly of wall mounted fan of 400 mm sweep complete all as specified and directed [Make: As approved for existing].
S&F in repairs 'U' clamp for hanging ceiling fan in ceiling to be fixed with 3" long anchor fastener 3 Nos for each clamps complete all as specified and directed [Make: As approved for existing].
S&F in repairs ceilling Fan down rod of size 15mm GI pipe medium grade (ISI mark) length upto 50cm including making holes, nut bolts, spilit pin washers etc complete all as specified and directed [Make: As approved for existing].
S&F in repairs PVC insulated multistranded Copper conductor, sheated round cable ISI marked 1.0 sqmm x 3 core complete all as specified and directed. [Make : Finolex/ Havells/Paragon]
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine.Spray painting including cleaning, washing and preparation of old painted surfaces including writing MES Nos in all ceiling and Exhaust fan complete all as specified and directed. Note:- Taking down and fixing of fan will be measured under item No. 1 here-in-before.
Ceiling fan upto 1200/1400 mm sweep complete.
Exhaust fan upto 280/300/380/450 mm sweep with smoke grey paint
M&L for attending the complaint of fan not working/ slow speed at site by deploying electrician and checking all electrical connection, tightening/ refixing of any loose electrical connections/ wires, replacement of weak / unservicable condensor etc at site and to make the fan functional without taking down from ceiling complete all as specified and directed. Note : Cost of condensor will be paid under relevant item.
S&F in repairs blade assembly of celling fan of 1200 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F in repair switch socket combined outlet 6 pin, flush type, 15 Amp, multi purpose SI marked complete all as specified and as directed. Make : Anchor / L& T/ Havells
S&F in repair stepped type electronic fan regulator 100 watt flush type (delux) on existing hylem laminated sheet complete all as specified and as directed. Make: Anchor (Delux) / L&T/ Havells
M&L for complete servicing of solar hot water system (solar water heater, flate plate collector type), with cleaning of sluge deposited in pipe line of solar pannel by using cleaning agent, check and repair of pipe line for any leakage, including carring out brazing of copper pipe for leakage, cleaning of glass shell, cleaning of hot water tank, replacement ofunserviceable clamps, adopter, hose pipe including complete sevicing to keep the plant functional of capacity up to 200 LPD complete all as specified and as directed.
S&F in replacement electrical heating element of 2.0 KW (long thread type, as per existing), ISI marked, of solar water heater of capacity up to 200 LPD complete all as specified and as directed. Make: Solar Element or equivelent as approved by GE.
S&F in replacement thermostate, long body, ISI marked of solar water heater of capacity up to 200 LPD complete all as specified and as directed.
S&F in replacement solar hot water tank with thermal insulation suitable for solar water heater of capacity 100 LPD. Make : TATA/ Supreme solar complete all as specified and as directed
S&F in replacement solar hot water tank with thermal insulation suitable for solar water heater of cap 200 LPD complete all as specified and as directed. Make : TATA/ Suprem solar.
S&F in replacement hot water pipe insulation with glass wool and aluminium cladding 20 mm bore including all material complete all as specified and as directed.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 including wooden rectangle board of first quality of suitable size for mounting of DB box complete all as specified and directed. Make- Legrand/ Seimens/ Schinder.
Taking down of Gyser of any capacity any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaning the inner tank properly and re-assembling the same and refixing to its existing location with testing for its proper functioning complete all as specified and directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new geyser element of 2.0 KW, 230 volts to match with the existing system complete all as specified and directed. [Make: Bajaj/ Usha /Recold]
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new thermostat with setting range 30 C to 80 C suitable for 230 volts AC electric supply. complete all as specified and directed. [Make : Danfoss / Ranco / Indfoss]
Disconnecting, dismantling & taking up or down existing unserviceable geyser indication lamp of any description and in any position from geyser of 25 Ltrs / 50 Ltrs capacity installed at site and supply and fixing new indication lamp (set of two) complete all as specified and directed.
Disconnecting & taking up or down existing unserviceable PVC connections of any description from geyser installed at site and supplying and fixing new 15mm PVC Connection with steel reinforced pipe for hot water connection of length 450mm including rubber washers complete all as specified & directed. [Make :Prayag or equivalent in approved make by GE.]
M&L for painting of the items given below of any description and in any position, by applying two coats of paint (DUCO) white by spray machine including preparation of existing decorated surfaces including writing MES No. in capital letters of height not less than 20 mm in the pattern and style complete all as specified and directed:- Geyser 25 ltrs capcity.
M&L for painting of the items given below of any description and in any position, by applying two coats of paint (DUCO) white by spray machine including preparation of existing decorated surfaces including writing MES No. in capital letters of height not less than 20 mm in the pattern and style complete all as specified and directed:- Geyser 50 ltrs capcity.
S&F in replacement of 3 pin plug top AC-230 v 15 Amp complete all as specified and directed. Make : Anchor/ L&T/Havells
S&F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V, complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and directed. Make : Legrand cat part No. 607841 or equivelent in Scheinder/ L&T.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor FRLS cable (with colour code), drawn in and including non metallic rigid PVC conduit of 25 mm dia, ISI marked including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed. Make of wire : L&T / Polycab/ C&S
Deduct schedule of credit (calculation will be done off line) Rs.368832.50
UMESH ENTERPRISES
RAJPATI CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .