| Sl No | Description | Qty | Unit | L-7 Primewave Communications L1 | M/S ZENITH TRADE LINK L3 | M/S BASHIR AHMAD AND SONS L2 | Electromech Engineers L6 | ORISON ENTERPRISES L4 | M/S M.A.S ELECTRICALS L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labor for carefully removing unserviceable air conditioners from their existing installed locations, including safely discharging the refrigerant, vacuuming both indoor and outdoor units, and removing the unserviceable voltage stabilizer. The AC unit, along with the stabilizer and all associated accessories, shall be submitted to Ref & AC store at E/M subdivision as specified and directed. | 26 | Each Job | 1,500 ₹39,000 | 400 ₹10,400 | 1,500 ₹39,000 | 500 ₹13,000 | 100 ₹2,600 Lowest | 200 ₹5,200 |
| 2.00 | Supply and install hi wall split AC indoor/outdoor unit complete with cordless remote control unit and with cooling and heating function of capacity 1.5 TR of BEE 3 star rating minimum, single phase and Digital Inverter twin rotary complete with mounting arrangements all as specified and as directed by Engr-in-charge.(Makes-Voltas/Blue Star/Hitachi/Diakan) | 28 | Each | 48,500 ₹13,58,000 Lowest | 53,400 ₹14,95,200 | 52,000 ₹14,56,000 | 55,000 ₹15,40,000 | 55,000 ₹15,40,000 | 54,000 ₹15,12,000 |
| 3.00 | Supply and install hi wall split AC indoor/outdoor unit complete with cordless remote control unit and with cooling and heating function of capacity 2.0 TR of BEE 3 star rating minimum, single phase and Digital Inverter twin rotary complete with mounting arrangements all as specified and as directed by Engr-in-charge.(Makes-Voltas/Blue Star/Hitachi/Diakan) | 19 | Each | 58,000 ₹11,02,000 Lowest | 66,300 ₹12,59,700 | 67,000 ₹12,73,000 | 66,000 ₹12,54,000 | 70,000 ₹13,30,000 | 67,500 ₹12,82,500 |
| 4.00 | Supply only 5.0 KVA Voltage stabilizer suitable for Air conditioner 2.0 TR having voltage range 90-300 volts I/C outgoing stabilized at 230 Volts+/- 5% tolerance complete all as specified.(Makes-Sinetrac/Blue Bird/BlueStar/Integ) | 19 | Each | 10,000 ₹1,90,000 | 10,500 ₹1,99,500 | 12,000 ₹2,28,000 | 6,500 ₹1,23,500 Lowest | 11,500 ₹2,18,500 | 8,400 ₹1,59,600 |
| 5.00 | Supply only 4.0 KVA Voltage stabilizer suitable for Air conditioner 1.5 TR having voltage range 90-300 volts I/C outgoing stabilized at 230 Volts+/- 5% tolerance complete all as specified.(Makes-Sinetrac/Blue Bird/BlueStar/Integ) | 28 | Each | 9,000 ₹2,52,000 | 11,000 ₹3,08,000 | 10,000 ₹2,80,000 | 5,500 ₹1,54,000 Lowest | 10,500 ₹2,94,000 | 6,500 ₹1,82,000 |
| 6.00 | Supply fixing and installation of 2 AC timer digital heavy duty metallic with powder coated enclosure and LCD messaging display based on latest micro controller technology , supply voltage 230V ac, 50 Hz +/-15% , LCD display 2*16 characters , 1 hr to 24 hrs settable timer , wall mounting , delay time facility suitable for window , split with atleast 12 months of warranty complete all as specified and as directed by Engr-in-charge | 1 | Each | 4,000 ₹4,000 Lowest | 14,000 ₹14,000 | 6,900 ₹6,900 | 25,000 ₹25,000 | 7,000 ₹7,000 | 21,900 ₹21,900 |
| 7.00 | S & F Sub main wiring with PVC insulated FRLS cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor in and incl rigid PVC Casing & Capping (ISI marked) incl all specials/accessories etc and provision of PVC insulated FRLS copper conductor single core 4.0 sq mm for earth continuity all as directed. | 1,000 | RM | 190 ₹1,90,000 | 180 ₹1,80,000 | 150 ₹1,50,000 | 315 ₹3,15,000 | 100 ₹1,00,000 Lowest | 195 ₹1,95,000 |
| 8.00 | S & F Sub main wiring with PVC insulated FRLS cable 2 single core 6 sq mm 1100 V grade with stranded copper conductor in and incl rigid PVC Casing & Capping (ISI marked) incl all specials/accessories etc and provision of PVC insulated FRLS copper conductor single core 6.0 sq mm for earth continuity all as directed. | 300 | RM | 400 ₹1,20,000 | 210 ₹63,000 | 220 ₹66,000 | 425 ₹1,27,500 | 150 ₹45,000 Lowest | 289 ₹86,700 |
| 9.00 | Supply, laying or passing through pipe, in trench underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminum conductor of size 16 Sqmm, 4 core including making electrical connection with thimbles complete all as specified. | 200 | RM | 400 ₹80,000 | 140 ₹28,000 | 130 ₹26,000 | 225 ₹45,000 | 110 ₹22,000 Lowest | 285 ₹57,000 |
| 10.00 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out soil in soft/loose soil complete all as specified. | 54 | Cum | 350 ₹18,900 | 150 ₹8,100 Lowest | 150 ₹8,100 Lowest | 200 ₹10,800 | 150 ₹8,100 Lowest | 350 ₹18,900 |
Tender Value
₹44.8 L
EMD Value
₹89,640
Closing Date
4 Jul 2025, 6:00 pmClosed
GE AF AWANTIPUR
GE AF AWANTIPUR
PROVISION OF ACS AT CERTAIN LOCATION AND RENEWAL/ REPLACEMENT OF BER ACS AT AF STN AWANTIPUR
2025_MES_714075_1
GE-AF-AWA-17-25-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AWANTIPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AF AWANTIPUR
₹89,640
Yes
19 Sept 2025
12 Jun 2025
7 Jul 2025
12 Jun 2025
4 Jul 2025
27 Jun 2025
Amount
Material and labor for carefully removing unserviceable air conditioners from their existing installed locations, including safely discharging the refrigerant, vacuuming both indoor and outdoor units, and removing the unserviceable voltage stabilizer. The AC unit, along with the stabilizer and all associated accessories, shall be submitted to Ref & AC store at E/M subdivision as specified and directed.
Supply and install hi wall split AC indoor/outdoor unit complete with cordless remote control unit and with cooling and heating function of capacity 1.5 TR of BEE 3 star rating minimum, single phase and Digital Inverter twin rotary complete with mounting arrangements all as specified and as directed by Engr-in-charge.(Makes-Voltas/Blue Star/Hitachi/Diakan)
Supply and install hi wall split AC indoor/outdoor unit complete with cordless remote control unit and with cooling and heating function of capacity 2.0 TR of BEE 3 star rating minimum, single phase and Digital Inverter twin rotary complete with mounting arrangements all as specified and as directed by Engr-in-charge.(Makes-Voltas/Blue Star/Hitachi/Diakan)
Supply only 5.0 KVA Voltage stabilizer suitable for Air conditioner 2.0 TR having voltage range 90-300 volts I/C outgoing stabilized at 230 Volts+/- 5% tolerance complete all as specified.(Makes-Sinetrac/Blue Bird/BlueStar/Integ)
Supply only 4.0 KVA Voltage stabilizer suitable for Air conditioner 1.5 TR having voltage range 90-300 volts I/C outgoing stabilized at 230 Volts+/- 5% tolerance complete all as specified.(Makes-Sinetrac/Blue Bird/BlueStar/Integ)
Supply fixing and installation of 2 AC timer digital heavy duty metallic with powder coated enclosure and LCD messaging display based on latest micro controller technology , supply voltage 230V ac, 50 Hz +/-15% , LCD display 2*16 characters , 1 hr to 24 hrs settable timer , wall mounting , delay time facility suitable for window , split with atleast 12 months of warranty complete all as specified and as directed by Engr-in-charge
S & F Sub main wiring with PVC insulated FRLS cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor in and incl rigid PVC Casing & Capping (ISI marked) incl all specials/accessories etc and provision of PVC insulated FRLS copper conductor single core 4.0 sq mm for earth continuity all as directed.
S & F Sub main wiring with PVC insulated FRLS cable 2 single core 6 sq mm 1100 V grade with stranded copper conductor in and incl rigid PVC Casing & Capping (ISI marked) incl all specials/accessories etc and provision of PVC insulated FRLS copper conductor single core 6.0 sq mm for earth continuity all as directed.
Supply, laying or passing through pipe, in trench underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminum conductor of size 16 Sqmm, 4 core including making electrical connection with thimbles complete all as specified.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out soil in soft/loose soil complete all as specified.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified.
M&L for GI Tubes, 'light grad', galvanised of 40 mm bore with all fitting for fixing on the wall complete all as specified and as directed.
M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified. Note: Punned thickness of sand shall be measured & paid.
Well burnt old size class 'B' bricks of nominal size 230X115X75 mm abutting each other for cable protection, complete all as specified and directed
M&L for Cutting of bitumen road/PCC road/hard standing for laying of GI pipe and passing of cable including making good to disturbed surface with PCC (1:4:8) type B1, using 20 mm graded crushed stone aggregate and matching with existing surface, complete all as specified and directed.
Supply & Fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 V, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosure DB SPN 4 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing complete all as specified.
S&F in replacement of sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB TP/TPN as incomer & MCB SP as outgoing complete all as specified.
S&F in replacement of MCBs, SP, 6-32 Amps, 230 volts,10 kA rupturing capacity, B curve type complete all as specified.
S&F in replacement of MCBs, SPN, 32 Amps, 230 volts, 10 kA rupturing capacity, B curve type complete all as specified.
S&F in replacement of MCBs, TPN, 25-63 Amps, 415 volts, 10 kA rupturing capacity, B curve type complete all as specified.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and as directed.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified. (For TPN DB)
M/S BASHIR AHMAD AND SONS (BID ID -3346445)
M/S ZENITH TRADE LINK (BID ID -3346359)
ORISON ENTERPRISES (BID ID -3346000)
M/S M.A.S ELECTRICALS (BID ID -3344165)
Electromech Engineers (BID ID -3346573)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .