Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Rejected due to docus not found in order |
Tender Value
₹75,700
Closing Date
27 Feb 2025, 6:00 pmClosed
Garrison Engineer AF Mohanbari
Garrison Engineer AF Mohanbari Mohanbari Post Dibrugarh Assam 786012
Soil investigation and Structural design in ro Upgradation of Stn Fire Section at AF Stn Dinjan under GE (AF) Mohanbari
2025_MES_696902_1
3005/17/E3
Limited
Miscellaneous Goods
Supply
30 days
Dinjan
As per tender documents
6 documents required · 6 mandatory
₹0
Exempted
22 Mar 2025
7 Feb 2025
28 Feb 2025
7 Feb 2025
27 Feb 2025
8 Feb 2025
Amount
Carrying out soil investigation as given below :- Boring through sand/clay/soft strata with 150mm pipe from ground level to 10 mtr depth. (a) Subsurface investigation :- (i) Grain size analysis, specific gravity, unit weight and natural moinsture content of soil. (ii) Liquid limit, plastic limit & swelling index. (iii) Consolidated tests for consolidation properties. (iv) Shear strength tests for shear strength parameters. (v) Chemical tests for soluble chloride and sulphate based in local information and experiences. (vi) Field tests as per Appx 'C' of IS 1892. (vii) Plate load tests at recommended depth of foundation. (viii) Pate load tests at recommended depth of foundation. (ix) CBR values (Soaked & unsoaked) & K value for strata. (x) Depth of water table if found in bore holes shall to be reported to GE. (b) The report to include clearly the following parameters :- (i) Layout of trial pits & bore holes on proposed site plan. (ii) Record of boring as per Appx 'D' of IS 1892. (iii) Soil/Rock properties as per detailed exploration (Table 3 of IS 1892). (iv) Soil properties basd on field tests. (v) Estimation of safe bearing pressure based on safe bearing capacity as per shear criteria and settlement criteria for rectangular. It also include detailed calculation of SBC. Note : In case low bearing capacity recommendation may include bearing capacity calculation SBC & Settlement calculation for raft foundation. (vi) Recommendation for pile with pile capacity in case weaker strata in encountered. (vii) Other relevant recommendation for foundation and improvement of soil if necessary. (viii) Recommendation of existing soil for backfill purpose. Notes for item No 1 : (ii) all the reports/results will be got vetted from any of the IIT's or Govt Engineer College's after approval from GE/Engineer-in-Charge.
Preparation of structural design and architectural drawing for Upgradation of Stn Fire Section at AF Stn Dinjan. Plinth area of bldg 38.21 Sqm. Note :(a) Architectural Drawing, Structural Design and drawing included Design claculation folder shall be vetted by IIT/Govt Engg college in original. (b) Bidder shall have to submit 5 (Five) copies of drawing in A3 size and soft copy in CD. (c) Completion duration 30 (thirty) from the day issue of Job Order.
S.G. Foundation & Engineers (BID ID -3250355)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .