| Sl No | Description | Qty | Unit | M/S MSD & Associate L4 | RISHU CONSTRUCTION COMPANY L1 | R.P Builders L3 | Ex Serviceman Enterprises L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of reinforced cement concrete in roof, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspende work complete all as specified and directed.
Note: The work shall be carried out upto sixth storey height of buildings including all safety factor. | 5 | Cum | 340 ₹1,700 | 400 ₹2,000 | 400 ₹2,000 | 300 ₹1,500 Lowest |
| 2.00 | M&L for fixing rebar of required length & diameter for structural connection in RCC slab, Baems and similar situations including power drilling holes of appropriate diameters in reinforced or plain concrete upto depth minimum 100 mm or as per manufacturers specification, fixing the reinforcement in position using epoxy Arcylate based anchoring adhesive at all heights and levels, 14 mm dia hole suitable for inserting 10 mm dia reinforcement bars complete all as specified and directed.
Note: The work shall be carried out upto sixth storey height of buildings including all safety factor. | 650 | Each | 450 ₹2,92,500 | 95 ₹61,750 | 120 ₹78,000 | 80 ₹52,000 Lowest |
| 3.00 | S&F additional reinforcement for strengthening the existing RCC structure, TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Note: The work shall be carried out upto sixth storey height of buildings including all safety factor. | 509 | Kg | 98 ₹49,882 | 72 ₹36,648 Lowest | 72 ₹36,648 Lowest | 80 ₹40,720 |
| 4.00 | M&L for reinforced cement concrete 1:2:4 type B-1 using 20 mm graded aggregate (nominal mix) in slabs supported on walls, beams and columns in floor, roofs, conopies and in shelves and like complete all as specified and directed.
Note: The work shall be carried out upto sixth storey height of buildings including all safety factor. | 5 | Cum | 7,800 ₹39,000 | 6,200 ₹31,000 | 7,000 ₹35,000 | 5,000 ₹25,000 Lowest |
| 5.00 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
Note: The work shall be carried out upto sixth storey height of buildings including all safety factor. | 97 | RM | 360 ₹34,920 | 45 ₹4,365 Lowest | 45 ₹4,365 Lowest | 50 ₹4,850 |
| 6.00 | M&L for form work to sides and soffits of floor or roof beams, cantilevers, shelves incl supports, overhang for rough finished flat surfaces complete all as specified and directed. | 33 | Sqm | 340 ₹11,220 | 325 ₹10,725 Lowest | 350 ₹11,550 | 400 ₹13,200 |
| 7.00 | Taking down cement or cement lime plaster any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed including removal of debris out side MoD land complete all as specified and directed.
Note: The work shall be carried out upto sixth storey height of buildings. | 2,000 | Sqm | 5 ₹10,000 Lowest | 10 ₹20,000 | 25 ₹50,000 | 13 ₹26,000 |
| 8.00 | M&L for rendering 15 mm thick on fair faces of brick/concrete surfaces in CM (1:4) finished with finish complete all as specified and directed.
Note: The work shall be carried out upto sixth storey height of buildings including all safety factor. | 2,045 | Sqm | 219 ₹4,47,855 | 170 ₹3,47,650 Lowest | 170 ₹3,47,650 Lowest | 421 ₹8,60,945 |
| 9.00 | M&L for rendering 10 mm thick on fair faces of brick/concrete surfaces as in ceiling/soffits in CM (1:4) finished with finish complete all as specified and directed.
Note: The work shall be carried out upto sixth storey height of buildings including all safety factor. | 233 | Sqm | 218 ₹50,794 | 180 ₹41,940 Lowest | 180 ₹41,940 Lowest | 210 ₹48,930 |
| 10.00 | M&L for finishing wall /ceiling with Acrylic smooth exterior paint of required shade: New work two coats applied @ 1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm) complete all as specified and directed.
Note: The work shall be carried out upto sixth storey height of buildings including all safety factor. | 2,500 | Sqm | 70 ₹1,75,000 Lowest | 110 ₹2,75,000 | 125 ₹3,12,500 | 100 ₹2,50,000 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
16 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
REPAIR TO CHAJJAS, BALCONIES, PARAPET WALL, PLASTER AND MISC CONNECTED WORKS IN MD OFFICERS ENCLAVE AT SP MARG UNDER GE NEW DELHI
2025_MES_715281_1
NIT No GE/ND-24/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE NEW DELHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NEW DELHI
₹90,000
Yes
14 Oct 2025
18 Jun 2025
18 Jul 2025
18 Jun 2025
16 Jul 2025
3 Jul 2025
Amount
Demolition of reinforced cement concrete in roof, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspende work complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for fixing rebar of required length & diameter for structural connection in RCC slab, Baems and similar situations including power drilling holes of appropriate diameters in reinforced or plain concrete upto depth minimum 100 mm or as per manufacturers specification, fixing the reinforcement in position using epoxy Arcylate based anchoring adhesive at all heights and levels, 14 mm dia hole suitable for inserting 10 mm dia reinforcement bars complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
S&F additional reinforcement for strengthening the existing RCC structure, TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for reinforced cement concrete 1:2:4 type B-1 using 20 mm graded aggregate (nominal mix) in slabs supported on walls, beams and columns in floor, roofs, conopies and in shelves and like complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for form work to sides and soffits of floor or roof beams, cantilevers, shelves incl supports, overhang for rough finished flat surfaces complete all as specified and directed.
Taking down cement or cement lime plaster any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed including removal of debris out side MoD land complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings.
M&L for rendering 15 mm thick on fair faces of brick/concrete surfaces in CM (1:4) finished with finish complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for rendering 10 mm thick on fair faces of brick/concrete surfaces as in ceiling/soffits in CM (1:4) finished with finish complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for finishing wall /ceiling with Acrylic smooth exterior paint of required shade: New work two coats applied @ 1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm) complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for finishing wall /ceiling with Acrylic smooth exterior paint of required shade: old work ( one coats applied @ 1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm) complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for uprooting grass/ plants (girth n.exc 15 cm of trunk to any of plants) grown along the pipes or walls, chajjas, parapets and roof or any othder location on the building upto sixth storey height including making good the surface as per existing surface and pouring acid not less than 100 ml for each plant in the roof to avoid further growth as directed with necessary scaffolding/form work required for completion of work upto sixth storey height including all safety factor complete all as specified and directed.
M&L for light shade vitrified tiles 9 to 10 mm thick (Square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 including dismantling of existing tiles complete all as specified and directed.
M&L for non skid ceramic tiles of approved colour and design 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 including dismantling of existing tiles complete all as specified and directed.
All as per Item No 14.00 above but as in skirting/ dado etc over and including renderning 10 mm thick cement mortar 1:4 complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed.
M&L for framed mild steel work of any description such as grills, gratings, railing for balcony area etc with ends of bars shouldered and/or riveted, welded or forged into spikes framed guard bars, barred doors & walk ways railings frame work of water tank and similar work confirming to Fe-290 Gde -E-165 complete all as specified and directed.
M&L for two coats of synthetic enamel paint on new steel and iron surfaces over a coat of red oxide primer incl preparation of surfaces over 10 cm width of girth complete all as specified and directed.
M&L for one coats of synthetic enamel paint on old wooden painted surfaces incl preparation of surfaces over 10 cm width of girth complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for one coats of synthetic enamel paint on old steel and iron surfaces incl preparation of surfaces over 10 cm width of girth complete all as specified and directed.
M&L for preparation of old painted stone wall surfaces and applying one coat of synthetic enamel paint complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
Taking up or down steel tubing and connections including cleaning for refixing or removal from site with all fittings for 15 mm bore GI tubings complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal from site with all fittings for 20 mm bore GI tubings complete all as specified and directed.
S&F medium grade galvanised steel tubing with all fittings fixed to walls and ceilings or laid in floors for 15 mm bore GI tubings complete all as specified and directed.
All as per item No 24.00 above but for 20mm bore pipe complete all as specified and directed.
Refixing old GI 15 mm dia tubing incl. new fittings to walls, ceilings or floors in old / new position complete all as specified and directed.
All as per item No 26.00 above but for 20mm dia pipe complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar or cement lime mortar complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L brick work with old size sub class B" bricks straight or curved on plan exc 6m mean radius in CM 1:4 (work incl parapet walls) complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
M&L for 75mm thick precast cement concrete ,type B-0, 1:2:4 (12.50 mm graded stone aggregate) as in louvres & jallies ( measured solid), set in CM 1:4 complete all as specified and directed.
S&F in repair 100mm dia cast iron spun pipe soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
All as per item No 31.00 above but fixed on walls complete all as specified and directed.
S&F in repair 75mm dia cast iron spun pipe soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
All as per item No 33.00 above but fixed on walls complete all as specified and directed.
S&F in repair CI bends 100mm dia (any radius), with duck's foot or heel rest complete all as specified and directed.
S&F in repair CI bends 75mm dia (any radius), diminishing pieces or tapers (larger bore measured), with oval access door complete all as specified and directed.
S&F in repair 100mm bore CI branch pieces,single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, with oval access door complete all as specified and directed.
S&F in repairs stack clamps out of 50 mm X 5 mm flat iron and 16 mm dia round bars incl bolts and nuts and securing ends of stays to walls or on roof 100 mm bore pipe complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
All as per item No 38.00 above but for 75mm dia bore pipe complete all as specified and directed.
Removal of debrish/malba out side the MD land to any lead, malba accumulated on the roof of block including old stacking of malba any type and bringing the same to down wards with all safety precautions and cleaning the entire roof surfaces ,top of chajjas removal of any vegetation/plants with roots on the roof/chajjas and making good disturbed surfaces with cement mortar/concrete to match the existing specification during removal of plants etc to the entire satisfication of Engr-in-charge complete all as specified and directed.
S&F in repair PVC (SWR) pipes single socketed, 50 mm bore in any length with rubber ring joints, fixed to walls including necessory for fixing clamp complete all as specified and directed. Note: The work shall be carried out upto sixth storey height of buildings including all safety factor.
S&F in repair PVC (SWR) bends/Tees of any radius of 50 mm bore complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground levels,incl removing the demolished material outside the MOD land complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6, type C-2 (40 mm agg) as in plinth protection finished even & smooth without using extra cement complete all as specified and directed.
Dismantling of brick tiles (laid flat or on edge) on roof surface laid bedded and pointed in any mortar complete all as specified and directed.
M&L for Demolition of mud in roof, any thickness, including plastering and leaping up to seven story bldgs. incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area complete all as specified and directed by Engr in charge.
M&L for cement concrete 1:2:4 type B0 (using 12.50 mm graded stone aggregate) as in levelling coarse over RCC slab to bring the desired slope up to six storied Bldg, using water proofing compound as per manufacturer instruction complete all as specified and directed. Note: Cost of Water proofing compound deemed to be included in this item
M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints complete all as specified and directed.
M&L for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner complete all as specified and directed.
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edge including necessary form work complete all as specified and directed.
M&L for Providing & Pouring Micro concreting M-40 grade :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : Master Emaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed including M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note : Form work shall be 100% leak proof. The cost of micro concrete M-40 grade & Epoxy bond coat is included in this item.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strata surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairly rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer complete all as specified and directed.
M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 43 grade and two part of sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 25 metre height) complete all as specified and directed. Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guniting is done with polycretes admixture @ 2% by weight of cement all as per manufacturers instructions (polycretes admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
S&F welded steel wire fabric, n.exc 4 Kg weight per sqm, cut to length bent to shape required and fixing with and including annealed mild steel wire not less than (0.90 mm dia or fixing with galvanised steel staples or welding supplied and fixed complete to wood or steel members complete all as specified and directed.
Dismantling A.C/Fibre sheet corrugated or semi corrugated sheet in roof coverings complete all as specified and directed.
S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in lieu of screws complete all as specified and directed. Note: The rates for these items deemed to be included for cleaning of complete house such as floor (includes application of pouncha with wet cloths), removing of all spots on door, glass pane, window and wall and floor tile in kitchen and bath room after Apex/ painting, cleaning of glass paes for door & windows including garges shutters & its shutter proper and over cover the furniture properly during Apex & painting of tarpoline cover paints in different room and lay out of all furniture items proplerly after completion of entire process complete all as specified and directed by Engineer In Charge. The above work shall be carried out upto sixth storey height of buildings including all safety factor. Note: (a) Srl Item No 08.00 to 11.00, 13.00, 14.00, 17.00, 19.00 to 21.00, 41.00, 44.00, 47.00 to 49.00, 53.00, 54.00 & 56.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody. (b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge.
Ex Serviceman Enterprises (BID ID -3355014)
R.P Builders (BID ID -3354710)
M/S MSD & Associate (BID ID -3360493)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .