Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC | L1 | Accepted-AOC Ist Lowest | |
| 2 | L2₹4.1 L+₹8,600 (2.16%)Rejected-AOC | L2 | Rejected-AOC IInd Lowest |
Tender Value
₹3.3 L
EMD Value
₹6,650
Closing Date
4 Apr 2024, 6:00 pmClosed
EE Civil Gurgaon
EE Civil BSNL Civil Division Sec-18 Gurgaon
R and mtc of Generator shad and Bldg in DLF IDC Faridabad SH Replacement of damaged of sheets provision of Shed above DG No. 2 3 and transformer inc ptg. of server hall, lobby, staircase etc. incl. pro. of main supply pipe line to bldg and mtc
2024_BSNL_192528_1
62/EE/BSNL/CD/GRG/2023-24
Open Tender
Civil Works
Item Rate
30 days
Faridabad
Please refer Tender documents.
10 documents required · 10 mandatory
₹590
A.O. (Cash) O/o GMTD BSNL, Faridabad
₹6,650
Yes
7 Jun 2024
28 Mar 2024
8 Apr 2024
28 Mar 2024
4 Apr 2024
28 Mar 2024
Amount
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (A) 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (A) Old Work (one or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. (A) New work (two or more coats)
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (A) One coat
(B) Two coats.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (A) One or more coats on old work.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (A) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. (A) With cement mortar 1:4 (1 cement : 4 fine sand).
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (A) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (A) Asbestos cement sheet / Fibre sheet
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall (A) 20 mm nominal outer dia. Pipes.
(B) 25 mm nominal outer dia .Pipes.
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (A) 25 to 40 mm nominal bore
Providing and fixing CPVC union of approved brand and manufacture complete as per directions of Engineer-in-charge (A) 20 mm dia
(B) 25 mm dia
Providing and fixing CPVC gate valve of approved brand and manufacture complete as per directions of Engineer-in-charge (A) 25 mm dia
Credit to work for dismantled materials (A) Mild Steel / Cast Iron / Fibre sheet Etc.
ANJAY MALHOTRA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .