Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.4 L+₹7,825 (0.43%)Rejected-AOC 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹21.8 L+₹3.4 L (18.7%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹22.1 L+₹3.8 L (20.6%)Rejected-AOC H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹22.7 L+₹4.3 L (23.6%)Rejected-AOC SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹39,920
Closing Date
3 Aug 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GOMANTAK
GE GOMANTAK VASCO PIN 403802
Maintenance and Cleaning of Sewage line manholes floor traps gully traps WCs and WHB etc and Septic tanks of AOR under AGE BR-I in GE Gomantak
2021_MES_458710_1
8293/E8
Open Tender
Support/Maintenance Service
Works
330 days
VASCO DA GAMA
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE GOMANTAK
₹39,920
Yes
9 Nov 2021
10 Jul 2021
4 Aug 2021
10 Jul 2021
3 Aug 2021
19 Jul 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10 sqm on plan and getting out in hard/dense soil.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10 sqm on plan and getting out in soft/disintegrated rock.
Demolition/breaking of drain pipes laid in trenches in foul condition of any dia.
Supply and fixing in repairs PVC (SWR) pipes 150 mm dia type'A'single socketed in any length with rubber ring joints laid in trenches or in floors
Material and labour for concrete bed to drain pipes (150mm dia) in cement concrete 1:4:8 type D2 using 40mm graded crushed stone aggregates including packing under and haunching against the sides of pipes after they are laid and tested complete.
Dismantling of cast iron drain pipe 100mm dia jointed in cement mortar and taking out of trenches/wall/floor etc incl fitting in foul condition.
Supply and fixing in repairs PVC (SWR) pipes 110 mm single socketed in any length with rubber ring joints fixed to walls in foul condition
Supply and fixing in repairs PVC (SWR) pipes 75 mm single socketed in any length with rubber ring joints fixed to walls in foul condition incl dismantling of old pipe.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any soil.
Removing of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point.
M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) using 40 mm graded stone aggregate
Demolition of stone/brick masonry wall built in cement mortar
M & L for precast cement concrete block masonry with solid blocks in cement concrete 1:3:6, type C1 using 20 mm graded crushed stone aggregate exc10 cm in width and set in CM 1:6 complete.
Material and labour for rendering 15 mm thick in CM 1:4 on brick/precast block masonry surfaces finished even and smooth without using extra cement.
Material and labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping including necessary form work.
Supply and fix mild steel TMT bars 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.
Supply and fix mild steel round bars 10mm dia FE 410W Gde E-250 quality A or Fe 290 gde E-165 cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips for man hole cover handle.
Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (reinforced)
Material and labour for precast cement concrete slab for manhole covers slab 1:2:4 type B1 using 20 mm graded crushed stone aggregate set in CM 1:4
Cleaning / clearing of sewage line of SWG pipe 150 mm dia choked with mud and other accumulated solids, semi solids etc with proper cleanining rods with water for proper functioning of sewage line complete all as specified and directed
All as per serial item No 20 hereinbefore but 100 mm dia pipe.
All as per serial item No 20 here-in-before but for gully traps/nahani traps.
Cleaning/clearing of manhole of any description any size not exceeding 1.5 m deep and removing sludge and accumulated solids/semi solids with proper equipment and washing down with water for smooth functioning of sewage line and man hole as specified and waste obtained shall be removed to a distance exceeding 200 m and not exceeding 250m and buried in ground including necessary excavation earth work and spreading of bleaching powder all as directed by Engineer-in-charge.
All as per serial item No 25 here-in-before but exceeding 1.5 m depth.
Cleaning and dewatering of septic tanks of any size or depth including cleaning outlet and inlet chambers outlet inlet pipes grills etc of any description and removing mud solid sludge and finally washing with water for smooth functioning of sewage incl removing sludge out side MD land at places approved by Municipal authorities by Manually.
Cleaning and dewatering of septic tanks of any size or depth including cleaning outlet and inlet chambers outlet inlet pipes grills etc of any description and removing mud solid sludge and finally washing with water for smooth functioning of sewage incl removing sludge out side MD land at places approved by Municipal authorities by Mechanically
Cleaning / removal of blockage from EWC/IWC/Gully traps/floor trap/wash hand basin etc choked with mud and other accumulated solids, semi solids etc with proper cleaning rubber bush/other instruments and cleaning with water for proper functioning of same complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repair PVC (SWR) bends any radius 110mm
S&F in repair PVC (SWR) bends any radius 75mm dia
S&F in repair PVC (SWR) vent cowl 75mm dia
Supply and Fix in repair PVC (SWR) vent cowl any radius 110mm
M&L in repair PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement
M&L in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement
Supply and fixing in repair PVC (SWR) pipes 110 mm single socketed in any length with rubber ring joints fixed to walls for rain water pipes
S & F in repairs vitreous china squating pan, Orissa pattern of size 580 X 440 mm white with integral foot rusts incl all necessary fittings all as directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern & flush pipe)
S & F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
S&F in repairs PVC valveless, syphonic action type, flushing cistern 10 litr capacity, low level, white, with intel, ball valve, float & handle including brackets
S&F Grating doom 125 mm dia with waste hole of PTMT. (min. weight 40 gms)
S&F Plastic water closet seat, black, closed pattern with flat bottom, & cover & mild steel CP or aluminised hinging device
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises.
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:4)
SHIVANI ENTERPRISES
SACHIN CONSTRUCTIONS
M/S DUBAL CONSTRUCTION
Tara Construction
M/s Gayatri Contruction Co.
CVs CONSTRUCTIONS
M/S Kartik Enterprises
Sai Supreme Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .