Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AND RAASONABLE | |
| 2 | L2₹9.7 L+₹1.6 L (19.2%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹11.4 L+₹3.2 L (39.6%)Rejected-AOC | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹12.0 L+₹3.8 L (46.7%)Rejected-AOC | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹12.0 L+₹3.9 L (47.3%)Rejected-AOC WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
2 Apr 2024, 6:00 pmClosed
GE EM RR HOSPITAL, DELHI CANTT 10
GE EM RR HOSPITAL, RAO TULA RAM MARG, DELHI CANTT 10
REPAIR TO DRAIN, CULVERT ETC AT STATIC WORKSHOP AREA, KLP LINE, MT ETC AT AHRR UNDER AGE BRI OF GE EM RR HOSPITAL, DELHI CANTT 10
2024_MES_644995_1
GE/H-53/2023-24
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT 10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹29,000
Yes
8 Jun 2024
4 Mar 2024
4 Apr 2024
4 Mar 2024
2 Apr 2024
19 Mar 2024
Amount
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/ loose soil, all as specified.
Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks (using old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:4, complete all as specified and directed.
All as per item No 03 here-in-before but except bricks.
Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified & directed.
M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement, complete all as specified & directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint, all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving n exc 15 cm thickness (below or above ground level), complete all as specified & directed.
M&L for cement concrete type D-2 1:4:8 (using 40 mm graded aggregate) as in foundation, filling and mass concrete, complete all as specified.
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded aggregates), as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed.
M&L for cement concrete 1:3:6, type C-2 (using 40 mm graded aggregates), as in surface channels and drain, complete all as specified.
Extra for forming fair finished drains or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, in soft/loose soil, all as specified.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, all as specified.
Manually Cleaning of existing drain of any width and any depth from ground level by rodding or by any means and blowing water through pipe for efficient functioning of drain including manpower and allied infrastructure required for smooth functioning and operation and removing the waste material out of defence land , complete all as specified and directed.
Demolition of reinforced cement concrete as in drains or manhole covers of any description and in any position not otherwise specifically provided for complete all as specified and as directed
S&F factory made RCC precast heavy duty drain covers 75mm thick with MS frame including reinforcement as per manufacture/ IS 12592, hot dip galvanized lifting hook for lifting overall cover, complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 (nominal mix) type B-1 (using 20mm graded stone aggregate), as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter to rough finish of surfaces, all as specified.
M&L for steel TMT bars 10 mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binging with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified.
All as per item no. 21 above but 5mm dia and over and up to and including 10mm dia in stirrups spacers and binders, complete all as specified and directed.
Demolition and breaking up drain pipes (SGSW, AC or reinforced concrete) set in cement mortar of 300 mm internal dia of Pipe, complete all as specified & directed.
S&F reinforced concrete pipes, class NP 3 of 300mm bore of pipe, with one collar per length of pipes, laid in trenches and jointed specified including testing, complete all as specified.
SURESH KUMAR SHARMA & CO
ACR ENTERPRISES
a.k constructions
imran construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .