Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.2 CrAccepted-AOC DHANI CHANDPUR BAWAL ROAD REWARI DHANI CHANDPUR BAWAL ROAD REWARI 123401 | REWARI | REWARI | HARYANA | 123401 | ₹4.2 Cr | 1 | Accepted-AOC lowest |
| 2 | 2₹4.9 CrRejected-AOC HOUSE NO 3123 66 WARD NO 23 SATI COLONY REWARI 123401 | REWARI | REWARI | HARYANA | 123401 | ₹4.9 Cr | 2 | Rejected-AOC highest |
| Sl No | Description | Qty | Unit | Sachin Goyal L2 | Rakesh Yadav Contractor L1 |
|---|---|---|---|---|---|
| 1.00 | Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling = 200 KVA The DG set should be according to CPCB IV plus draft notification effective from 1 july
2023 norms or any other upto date norms according to CPCB/Govt. complete in all respect. 200 KVA | 1 | Nos. | 24,00,000 ₹24 L | 22,00,000 ₹22 L |
| 2.00 | Providing and fixing of channel gate for channel size 1.0 x 1.0 mtr with actuator complete in all respect in satisfaction of engineer-in
charge. | 2 | Nos. | 12,75,000 ₹25.5 L | 8,00,000 ₹16 L |
| 3.00 | Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 35.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend
(D/F Bend) etc. complete in all respect the indicated. LPM - 9500 and BHP - 125 | 2 | Nos. | 14,95,000 ₹29.9 L | 14,50,000 ₹29 L |
| 4.00 | LT panel board indoor Type 0.415 KV ACB Control Cubical Panel with vertical Isolation Type Breaker as per relevant IS as amended up to date and Additional Specifications, having Capacities as mentioned below, Single break trip free mechanism, manually charged and Auto/Manuelly closing breaker suitable for use on 0.415 kv, 3 phase 50 hz AC Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF Indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as required (3) incoming and 3 outgoing) including provision of APFC Panel of 110 kVAR or as per suitable capacity.
(1) ACB, 0.415 kV, 800 Amp., 50 kA 02 Nos. (2) Changeover Switch 0.415 kV, 800 Amp., 50 kA- 01 Nos.( 3) MCCB, 415V, 4 pole, 50 KA a) 400 Amp. - 3 Nos. (1 No. outgoing for APFC panel).(4) Control panel- Cubicle type control panel suitable for floor mounting made out of 2 mm CR sheet duly powder coated and with following electrical equipment`s.
(5) THERMAL OVERLOAD RELAY- 02 Nos.(6) AUXILARY CONTACTOR a) 265 A (2 NO plus 2 NC) COIL Voltage 220V-02 Nos. b) 265 A (2 NO plus 2 NC) COIL Voltage 220V-02 Nos. c) 225 A (2 NO plus 2 NC) COIL Voltage 220V-02 Nos. (7) Timers for starters- 02 Nos. (8) ELCB (96X96 mm) For all starters- 02 Nos. (9) AIR COOLED AUTO TRANSFORMER STARTER- 02 Nos. a) Frequency of Open. 6 starts/hour (evenly spaced) or as per specification. b) Starting time: Suitable for 12sec starting or as per specification.
c) Taps: 50% /65% /80% or as per standard. d) Thermal cut-off: in-built.(10) RYB Indication Light as per outgoing. (11) ON/OFF/Trip indication Light as per outgoing. (12) Spring Charge Healthy Indication as per outgoing. (13) Trip Circuit Healthy Indication as per outgoing.(14) Push Button Test Accept and Reset as per outgoing. (15) Breaker Control Switch as per outgoing.(16) L/R Switch as per outgoing. (17) Emergency Push Button as per outgoing. (18) 10-Annunciator as per outgoing(19) Pin Plug. (20) Toggle Switch. (21) Hooter.
( 22) Door Switch as per outgoing. (23) Space Heater with Thermostat. (24) Control MCB as per outgoing. (25) LED as per outgoing (26) 32 Amp. X 3 Nos., 16 Amp. X 3 Nos. TP MCB for lightening load. For 9500 LPM X 35 Mtr Head (1 working plus 1 standby) | 1 | Job | 10,00,000 ₹10 L | 10,70,000 ₹10.7 L |
| 5.00 | HT Panel -Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/ Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure (such as G.O switch, H Pole and HT cable of required capacity etc. complete in all respect) arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG)
(a). VCB, 11KV, 630Amp, 50KA. ( b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s. (c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2. (d). Control panel- Cubicle type control panel suitable for floor
mounting made out of 1.63 mm CR sheet duly powder coated
and with following relays.
e). Microprocessor based numerical relay for O/L, E/F and SC
Protection suitable for above.
f). Master trip relay -2 no’s.
g). Indicator type Annunciator panel with buzzer.
h). Digital Volt Meter- 0-11 KV.
i). Digital Amp Meter- 0-100 Amp.
j). RYB/ Trip/Closing/Spring charged indicator lamp.
k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz
Relay Alarm And Trip Auxiliary relay.
l) TNC Switch for Operation.
m) Multifunction Meter EM6400NG.
n) TCS Relay for Safety.
For Bawal Road IPS | 1 | Job | 13,00,000 ₹13 L | 15,00,000 ₹15 L |
| 6.00 | Providing and fixing of EOT Crane of Capacity 3 MT including providing and fixing horizontal Beam and vertical column made from suitable size of MS girders to be installed, Confirms to IS : 3177-807, Class of Duty : 2nd Heavy Duty, Lifting Height : 15 Mtr., Location : outdoor Type, Speed : Hoisting - 3 Mtr / Min. (up and down Motion), Cross Travel – 15 Mtr / Min, Long Travel – 15 Mtr / Min, with 3 MT motorized hoist / chain pulley block. complete in all respect as per design, as per direction and satisfaction of Engineer -in- charge Capacity 3 ton | 1 | Nos. | 13,00,000 ₹13 L | 11,00,000 ₹11 L |
| 7.00 | Providing and fixing aluminum ladder stair 12 Feet long including fitting, jointing, fasner complete in all respect as per design satisfaction Engineer-in-charge | 1 | Nos. | 8,000 ₹8,000 | 7,000 ₹7,000 |
| 8.00 | Providing and fixing of 50 watt led lights make havells complete in all respect as per derication of Engineer-in-charge. | 5 | Nos. | 2,250 ₹11,250 | 1,875 ₹9,375 |
| 9.00 | Providing and fixing DI Flange Adopter of size 300 mm complete in all respect | 2 | Nos. | 9,000 ₹18,000 | 8,000 ₹16,000 |
| 10.00 | Providing and fixing DI Flange Adopter of size 400 mm complete in all respect. | 1 | Nos. | 15,000 ₹15,000 | 9,000 ₹9,000 |
Tender Value
₹4.6 Cr
EMD Value
₹9.3 L
Closing Date
15 Dec 2025, 5:00 pmClosed
VINAY PRAKASH CHAUHAN
Rewari PHED No. 1
Extension of Western side storm water network and up-gradation of Eastern side storm water network of Rewari Town
2025_HRY_487802_1
202550A4FCB8 B2EB 437C A874 3DE12B3037F1579PUH
Open Tender
Civil Works
360 days
Rewari
2 documents required · 2 mandatory
₹15,000
₹9.3 L
Yes
20 Jan 2026
3 Dec 2025
16 Dec 2025
3 Dec 2025
15 Dec 2025
3 Dec 2025
3 Dec 2025 - 5 Dec 2025
Amount
Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling = 200 KVA The DG set should be according to CPCB IV plus draft notification effective from 1 july 2023 norms or any other upto date norms according to CPCB/Govt. complete in all respect. 200 KVA
Providing and fixing of channel gate for channel size 1.0 x 1.0 mtr with actuator complete in all respect in satisfaction of engineer-in charge.
Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 35.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect the indicated. LPM - 9500 and BHP - 125
LT panel board indoor Type 0.415 KV ACB Control Cubical Panel with vertical Isolation Type Breaker as per relevant IS as amended up to date and Additional Specifications, having Capacities as mentioned below, Single break trip free mechanism, manually charged and Auto/Manuelly closing breaker suitable for use on 0.415 kv, 3 phase 50 hz AC Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF Indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as required (3) incoming and 3 outgoing) including provision of APFC Panel of 110 kVAR or as per suitable capacity. (1) ACB, 0.415 kV, 800 Amp., 50 kA 02 Nos. (2) Changeover Switch 0.415 kV, 800 Amp., 50 kA- 01 Nos.( 3) MCCB, 415V, 4 pole, 50 KA a) 400 Amp. - 3 Nos. (1 No. outgoing for APFC panel).(4) Control panel- Cubicle type control panel suitable for floor mounting made out of 2 mm CR sheet duly powder coated and with following electrical equipment`s. (5) THERMAL OVERLOAD RELAY- 02 Nos.(6) AUXILARY CONTACTOR a) 265 A (2 NO plus 2 NC) COIL Voltage 220V-02 Nos. b) 265 A (2 NO plus 2 NC) COIL Voltage 220V-02 Nos. c) 225 A (2 NO plus 2 NC) COIL Voltage 220V-02 Nos. (7) Timers for starters- 02 Nos. (8) ELCB (96X96 mm) For all starters- 02 Nos. (9) AIR COOLED AUTO TRANSFORMER STARTER- 02 Nos. a) Frequency of Open. 6 starts/hour (evenly spaced) or as per specification. b) Starting time: Suitable for 12sec starting or as per specification. c) Taps: 50% /65% /80% or as per standard. d) Thermal cut-off: in-built.(10) RYB Indication Light as per outgoing. (11) ON/OFF/Trip indication Light as per outgoing. (12) Spring Charge Healthy Indication as per outgoing. (13) Trip Circuit Healthy Indication as per outgoing.(14) Push Button Test Accept and Reset as per outgoing. (15) Breaker Control Switch as per outgoing.(16) L/R Switch as per outgoing. (17) Emergency Push Button as per outgoing. (18) 10-Annunciator as per outgoing(19) Pin Plug. (20) Toggle Switch. (21) Hooter. ( 22) Door Switch as per outgoing. (23) Space Heater with Thermostat. (24) Control MCB as per outgoing. (25) LED as per outgoing (26) 32 Amp. X 3 Nos., 16 Amp. X 3 Nos. TP MCB for lightening load. For 9500 LPM X 35 Mtr Head (1 working plus 1 standby)
HT Panel -Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/ Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure (such as G.O switch, H Pole and HT cable of required capacity etc. complete in all respect) arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG) (a). VCB, 11KV, 630Amp, 50KA. ( b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s. (c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2. (d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays. e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above. f). Master trip relay -2 no’s. g). Indicator type Annunciator panel with buzzer. h). Digital Volt Meter- 0-11 KV. i). Digital Amp Meter- 0-100 Amp. j). RYB/ Trip/Closing/Spring charged indicator lamp. k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay. l) TNC Switch for Operation. m) Multifunction Meter EM6400NG. n) TCS Relay for Safety. For Bawal Road IPS
Providing and fixing of EOT Crane of Capacity 3 MT including providing and fixing horizontal Beam and vertical column made from suitable size of MS girders to be installed, Confirms to IS : 3177-807, Class of Duty : 2nd Heavy Duty, Lifting Height : 15 Mtr., Location : outdoor Type, Speed : Hoisting - 3 Mtr / Min. (up and down Motion), Cross Travel – 15 Mtr / Min, Long Travel – 15 Mtr / Min, with 3 MT motorized hoist / chain pulley block. complete in all respect as per design, as per direction and satisfaction of Engineer -in- charge Capacity 3 ton
Providing and fixing aluminum ladder stair 12 Feet long including fitting, jointing, fasner complete in all respect as per design satisfaction Engineer-in-charge
Providing and fixing of 50 watt led lights make havells complete in all respect as per derication of Engineer-in-charge.
Providing and fixing DI Flange Adopter of size 300 mm complete in all respect
Providing and fixing DI Flange Adopter of size 400 mm complete in all respect.
Providing and fixing 250 AMP copper bus bar junction bar complete in all respect..
Providing and fixing cast iron double flange swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts and bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge = 300 mm i/d at Bawal IPS
Providing and fixing C.I. sluice valves (with wheel) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : - 300 mm i/d
Providing and fixing D.I. AIR valves complete with all accessories bolts, nuts, rubber insertions etc. 100 mm i/d for rising mains
providing and fixing D.I. Sluice valves (with Wheel) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): - 400 mm i/d
Providing and fixing Ductile iron double flanged swing check type reflux (non-return) valves PN- 1.6 including nuts and bolts, rubber sheet, carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect 400 mm..
Operation and maintenance of proposedStorm water Disposal complete in all respct including all Civil, electrical and Mechanical installation and Rising Mains upto final disposal point, complete scope of work under this contract as per Operation and maintenance Manual of NIT (Attached in additional Documents) for a period of 5 years after 12 month defect liability period and 3 months trial run period. (charged to A/Mtc estimate year wise) complete in all respect. Operation and maintenance during defect liability period (Operation only) after 3 months trial run period
Operation and Maintenance during 1st Year after Defect liability period
Operation and Maintenance during 2nd Year
Operation and Maintenance during 3rd Year
Operation and Maintenance during 4th Year
Operation and Maintenance during 5th year
Bidder Name
Amount
Sachin Goyal (GSTN-NA) BID ID -1385199
Rakesh Yadav Contractor (GSTN-NA) BID ID -1383369
Sachin Goyal (BID ID -1385199)
Sachin Goyal (BID ID -1385199)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
BOQ_565967.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid