Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L1 | Accepted-AOC Being L1 bid | |
| 2 | L2₹35.6 L+₹7,117.37 (0.20%)Rejected-Finance VILL GHARGA PO DWARNARI DIST PURBA BARDHAMAN PIN 713403 WB | PURBA BARDHAMAN | WEST BENGAL | 713403 | L2 | Rejected-Finance Being L2 bid | |
| 3 | L3₹37.0 L+₹1.5 L (4.30%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L3 | Rejected-Finance Being L3 bid |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
10 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (CGN) KOLKATA
GE (I) (Coast Guard Navy) Military Engineer Services Damodar Complex Naval Transit Accommodation Hastings, Kolkata700 023
REPAIR MAINTENANCE TO EXTERNAL STREET LIGHT AND OTHER E/M ITEM AND EXTERNAL ELECTRIC SUPPLY AND INTERNAL ELECTRIC FITTINGS FIXTURE AT NAVY AREA, TS BAGJOLA AND BM CAMP UNDER GE (I) (CGN) KOLKATA
2023_MES_633573_2
NIT No 8701/42/2023-2024/10/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kolkata
Class D and category b(i) or b(ii)
8 documents required · 8 mandatory
₹500
GE (I) (CGN) Kolkata
₹72,000
Yes
4 Mar 2024
20 Jan 2024
12 Feb 2024
20 Jan 2024
10 Feb 2024
27 Jan 2024
Amount
Taking down carefully copper/aluminium point wiring (light,fan,socket or power) complete, (including unscrewing from boards/outlet boxes fittings and fixtures such as switches, sockets,ceiling roses,lamp holders,brackets,ceiling fittings,bulk head fittings,tube light fittings and rfgulators,etc.) . removing materials off the site work and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for (concelaed) type point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 Sqmm (nominal area), PVC insulated, (FRLSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 Sqmm (nominal area) PVC insulated, unsheathed,copper cable multistraned conductor 1100 volts grade for earth continuity wire connecting to common earth dolly drawn through and including PVC conduit and making good the disturbed surfaces as per the existing complete all as specified and directed.( Note:A Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing.Separated cable for earthing and neutralto be used for each individule ckt from the distribution board (B) The Rate of point wiring includes the following :- (i) copper wire.(ii)PVC conduit with accessoreis.(ii) chase cutting.
All as per above item No 02 but for the one light point controlled by two way switch complete all as specified and as directed.
All as per item no.02 above but for one three pin 5 Amp socket outlet on same board.
All as per item no.02 above but for one three pin 5 Amp socket outlet on independent board.
M&L point wiring surface type with 2.5 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FR copper conductor cable 1100 Volts grade drawn through with and including PVC conduit/ PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling /surface/ concealed etc. with and including 2.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core FR copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for three pin 15 Amp socket outlet on independent board complete all as specified and directed.
M&L point wiring surface type with 4 Sqmm (nominal area), PVC insulated, stranded single core unsheathed FR copper conductor cable 1100 Volts grade drawn through with and including PVC conduit/ PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling /surface/ concealed etc. with and including 4 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core FR copper cable as earth continuity wire connecting to common earth point including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC / Plastic laminated sheet. top cover, suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulators etc complete for three pin 15 Amp socket outlet on independent board complete all as specified and directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
All as per above item 07 but for one light point controlled by two way switch complete all as specified and as directed.
All as per above item 07 but for one 3 pin socket outlet on the same board complete all as specified and as directed
All as per above item 07 but for one 3 pin socket outlet on the indpendent board complete all as specified and as directed
M & L for Concealed point wiring with 2.5 sqmm (Nominal area0 FRLS PVC insulated unsheathed multi stranded copper conductor,1100 Volts grade, in and including PVC conduit medium duty (ISI Marked ) not less than 20mm dia with accessories such as bends, cross,elbow,tees etc of suitable size including continuos earth wire FRLS PVC insulated Unsheathed 2.5 Sq mm (nominal) copper multi-stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly for 16 amps socket complete all as specified and directed
M&L Sub main wiring with two runs of 4.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FR copper conductor cable upto and including 1100 V grade drawn through concealed conduit fixed to walls / ceiling etc. complete including one run of 4.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed including taking down old one (Note :-(i) Two runs of 4.0 sqmm single core cable, one run of 4.0 sqmm earth continuity wire to be measured as one length). (ii) PVC conduit and necessary chase cuting with making the surface good is deemed to be incl in the quoted rate.
M&L Sub main wiring with two runs of 2.50 sqmm (Nominal area) single core PVC insulated stranded unsheathed FR copper conductor cable upto and including 1100 V grade drawn through concealed conduit fixed to walls / ceiling etc. complete including one run of 2.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed including taking down old one (Note :-(i) Two runs of 2.5 sqmm single core cable, one run of 2.5sqmm earth continuity wire to be measured as one length). (ii) PVC conduit and necessary chase cuting with making the surface good is deemed to be incl in the quoted rate.
M&L Sub main wiring with two runs of 6.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FR copper conductor cable upto and including 1100 V grade drawn through concealed conduit fixed to walls / ceiling etc. complete including one run of 6.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed including taking down old one (Note :-(i) Two runs of 6.0 sqmm single core cable, one run of 6.0 sqmm earth continuity wire to be measured as one length). (ii) PVC conduit and necessary chase cuting with making the surface good is deemed to be incl in the quoted rate.
M&L Sub main wiring with two runs of 10.0 sqmm (Nominal area) single core PVC insulated stranded unsheathed FR copper conductor cable upto and including 1100 V grade drawn through concealed conduit fixed to walls / ceiling etc. complete including one run of 10.0 sqmm (nominal area) single core, PVC insulated stranded unsheathed FRLS copper conductor as earth wire and duly connected to common earth point complete all as specified and directed including taking down old one (Note :-(i) Two runs of 10.0 sqmm single core cable, one run of 10.0 sqmm earth continuity wire to be measured as one length). (ii) PVC conduit and necessary chase cuting with making the surface good is deemed to be incl in the quoted rate.
S&F bell multi music type complete all as specified and as directed.
M & L Ceiling rose, surface type polycarbonate/ PVC three terminals, conforming to IS, complete all as specified and as directed.
S&F white cover plate with frame for Modular switch, 1 or 2 module complete all as specified and as directed.
S&F white cover plate with frame for Modular switch, 3 module complete all as specified and as directed.
S&F white cover plate with frame for Modular switch, 4 module complete all as specified and as directed.
S&F white cover plate with frame for Modular switch, 6 module complete all as specified and as directed.
S&F white cover plate with frame for Modular switch, 8 module complete all as specified and as directed.
Supply & fixing Modular metal flush box, 1 or 2 module complete all as specified and as directed.
Supply & fixing Modular metal flush box, 3 module complete all as specified and as directed.
Supply & fixing Modular metal flush box, 4 module complete all as specified and as directed.
Supply & fixing Modular metal flush box, 6 module complete all as specified and as directed.
Supply& fixing Modular metal flush box, 8 module complete all as specified and as directed.
S&F white blanking plate one module complete all as specified and directed.
Supply and fix ( sheet steel enclosure) SPN DBs, 8 way, double door for MCBs with din channel, Earth bar and neutral bar etc. complete all as specified and directed including taking down old one complete all as specified and as directed.
Supply and fix sheet steel metal enclosure SPN DBs, 4 way, for MCBs with din channel, Earth bar and neutral bar, double door type complete all as specified and directed including taking down old one complete all as specified and as directed.
Supply and fix sheet steel enclosure TPN DBs, 4 way, for MCBs with din channel, Earth bar and neutral bar, double door type complete all as specified and directed including taking down old one.
Supply and fix sheet steel enclosure TPN DBs, 12 way, for MCBs with din channel, Earth bar and neutral bar, double door type complete all as specified and directed including taking down old one.
Supply and fix MCB SP 240V, 6-32 Amps capacity including taking down old one complete all as specified and directed. Make : Legrand / Schneider/GE
Supply and fix MCB SPN C- Curve, 240V 32 Amps capacity including taking down old one complete all as specified and directed. Make : Legrand /ABB/Schnieder.
Supply and fix MCB SPN C- Curve, 240V 40 Amps capacity including taking down old one complete all as specified and directed. Make : Legrand /ABB/Schnieder.
Supply and fix MCB SPN C- Curve, 240V 63 Amps capacity including taking down old one complete all as specified and directed.
Material and labour in repairs for MCB, FP, 'C' series, 16-32 Amps complete all as specified and as directed.
Material and labour in repairs for MCB, FP, 'C' series, 40-100 Amps complete all as specified and as directed.
Material and labour in repairs for MCB, DP 'C' series, 6-32 Amps complete all as specified and as directed.
S & F metal flush box 4 Module for mounting starter / socket unit including necessary cutting in wall for fixing the box and making good the disterbed surfaces complete all as specified and directed.
S & F white cover plate with frame for Modular metal flush box 4 module complete for mounting starter / socket unit complete all as specified and as directed.
S & F modular socket 6/16 Amps, 3/6 pin, 240 Volts, two modules complete all as specified and as directed.
S & F single phase motor starter current rating 16.00 -25.00 Amps, 240 Volts, two modules complete all as specified and as directed.
S&F for Power unit 6M flush type with AC starter, 20Amps MCB & 20Amps Plug top with indicator, 6module plate including connection complete all as specified and as directed.
S & F metal box 6 Module for mounting power unit complete all as specified and as directed.
S & F switch piano, flush type, 5/6 Amps, 240 Volts, single pole, one way, conforming to IS complete all as specified and as directed including taking down old one complete all as specified and as directed.
S & F switch piano, 5A, Sp 230V 2 way complete all as specified and as directed
S & F switch piano, flush type, 15/16 Amps, 240 Volts, single pole, one way, conforming to IS complete all as specified and as directed including taking down old one.
Supply and fixed lamp holder , PVc/ polycarbonated type complete all as specified and as directed
Supply and fixed call bell, multi music type complet all as specified and as directed.
S&F bell push flush type, 5 Amps 230 Volts complete all as specified and as directed including taking down old one.
S & F Switch socket combination 3/5 Pin, 5/6 Amps, 240 Volts, flush type multi-purpose, conforming to IS complete all as specified and as directed including taking down old one.
S & F Switch socket combination 6 Pin, 15/16 Amps, flush type, multipurpose, conforming to IS complete all as specified and as directed including taking down old one.
S & F Switch socket combination 2 in 1 3 Pin, 5 Amps, flush type, multipurpose, conforming to IS complete all as specified and as directed including taking down old one.
Supply and fixed socket outlet 2 in 1 5/6 pin, 15 Amps flush type complete all as specified and as directed.
Supply and fixed socket outlet 6a, 2/3 pin combined 2 module modular type complet all as specifiesd and as directed.
S & F stepped type electronic fan regulator flush type 100 W complete all as specified and directed including taking down old one complete all as specified and as directed.
M&L bell,AC 230 Volts single pole complete all as specified and as directed including taking down old one.
Supply , fix and connecting ceiling fan / exhaust fan capacitor of capacity 2.5 mfd complete all as specified and directed including taking down old one.
S & F modular switch 6 Amps, 240 Volts, single pole, one way, one module conforming to IS complete incl taking down old one, all as specified and as directed.
S & F modular switch 16 Amps, 240 Volts, single pole, one way, one module conforming to IS complete incl taking down old one, all as specified and as directed.
S & F modular socket 6 Amps, 5 pin, 240 Volts, two module conforming to IS complete incl taking down old one, all as specified and as directed.
S & F modular socket 16 Amps, 3 pin, 240 Volts, two modules conforming to IS complete incl taking down old one, all as specified and as directed.
S&F Modular bell push 10A, 1 module complete incl taking down old one, all as specified and as directed.
S&F Modular fan step regulator, 2 modules complete incl taking down old one, all as specified and as directed.
Supply and fixing LED BLDG security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and Fixing of Recessed Surface Mounted Round slim & Elegant LED 15 watt 230 V AC Downlight made of aluminium PDC housing for indoor applications with high asthetic appeal for uniform light.
Supply & Fix in Surface mounted indoor decorative 1x1 LED luminaire,18 watt suitable for Gypsum ceiling, complete and connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including taking down old one.complete all as specified and as directed.
Supply and fixed recessed/ surface mmounted full open 2 ft x 2 ft tile glare free, uniform illumination with longer life kless maintenance, 36 wat with minimum lumen capacity 110 Lumen per Watt complerte all as specified and as directed.
Supply and fixed 35 watt building security light made up the pressure die cast housing with IP 66 protection, Min 110 lumen per efficiency including the suitable length of bracket made up of the 32 mm dia GI pipe, light grade complete all as specified and as directed.
M & L for 1x10 watt LED Celing/wall mounted lightining fixture with lamp Lumen not less than 100 lum/watt polycarbonate,enviormental friendly,energy efficient fixed to wall/ceiling & connecting from ceiling rose to fitting terminal complete allas specified and as directed by Engr -in-charge including taking down old one.
M & L for 1x20 watt LED Celing/wall mounted lightining fixture with lamp Lumen not less than 100 lum/watt polycarbonate,enviormental friendly,energy efficient fixed to wall/ceiling & connecting from ceiling rose to fitting terminal complete allas specified and as directed by Engr -in-charge including taking down old one.
S and F LED bulb type 9 watt in warm white /natural white complete all as specified and as directed including taking down old unserviceable one.
S and F LED bulb type 12 watt in warm white /natural white complete all as specified and as directed including taking down old unserviceable one complete all as specified and as directed.
S & F LED Flood light 30 Watt madeup of pressure die cast aluminium housing with toughened glass and high power led and secondary lenses with IP66 protection with 10 KV SPD and system efficacyof 110 LPW and necessary bracteks and fittings incl taking down old one complete all as specified and as directed.
S & F 15 Watt LED POST TOP Light, IP65 rating,energy saving, long life with symmetrical light distribution suitable for outdoor ,spun aluminium landscape lumiaire with high power LEDs as light source and necessary brackets and fittings incl taking down old one complete all as specified and as directed.
Supply & fixing MCCB 63Amps,10 KA ,4 pole,415 volts,50 Hz,having thermal setting range 70% to 100% and fixed magnetic setting and break capacity 10 KA incld making incoming and outgoing connection after (Make- Legrand/ Schneider/ L&T) taking down old one complete all as specified and as directed.
Supply & fixing MCCB 100 Amps,36 KA ,4 pole,415 volts,50 Hz,having thermal setting range 70% to 100% and fixed magnetic setting and break capacity 35 KA incld making incoming and outgoing connection after taking down old one complete all as specified and as directed.
Supply & fixing MCCB 400 Amps,36 KA, 4 pole,415 volts,50 Hz,having thermal setting range 70% to 100% and fixed magnetic setting and break capacity 36 KA incld making incoming and outgoing connection after taking down old one complete all as specified and as directed.
Serviceing of split /window type AC unit of capacity 1.5/2.0 TR that includs cleaning of air filtres, indoor unit it griless and filtre through air blower cleaning of indoor unit body by wiping out dust etc. with wet cloth, cleaning of blower and condensor fan cleaning of evaporator and condensor coils graseing/oiling of motors and all moving parts and checking various parts of AC for proper functioning.(Note : (1) All majar parts or spares as mentioned below will be measured separately. (ii) Charging of gas tobe measured separately.)
Supply & charging R-134A/ R-22/410A refrigerant gas complete all as specified and as directed.
S & F only Hermeatically sealed unit of compressor for AC of 1.5 TR capacity including charging gas R-134 A complete including taking down old one complete all as specified and as directed.
S & F only Hermeatically sealed unit of compressor for AC of 2.0 TR capacity including charging gas R-134 A complete including taking downold one complete al las specified and as directed.
S &F Electronic circuit board as existing type for 1.5 TR capacity split type AC complete including taking downold one complete all as specified and as diredcted.
S &F Electronic circuit board as existing type for 2.0 TR capacity split type AC complete including taking down all as specified and as diredcted.
S & F display board as existing type for 1.5 TR / 2.0 TR capacity split/window type AC complete including taking down all as specified and as directed.
S & F capacitor combined type 50 MFD capacity for 1.5 TR/2.0 TR split type AC complete including taking down all as specified and as directed.
S & F Capilary tube copper 1.5 TR/2.0 TR split type AC as per existing type complete including taking down allas specified and as directed.
S & F electrical treminal for outer unit PVC /Polycarbonate including taking down aii as specified and as directed.
S & F Blower fan motor for indoor unit 1.5 TR/2.0 TR split type AC as per existing type complete including taking down allas specified and as directed.
S & F outer fan motor for outdoor unit 1.5 TR/2.0 TR split type AC as per existing type complete including taking down allas specified and as directed.
S & F swing motor for indoor unit 1.5 TR/2.0 TR split type AC as per existing type complete including taking down allas specified and as directed.
Supply only remote for the 1.5/2TR AC of any make model complete all as specified and as directed.
Supply and fixed condensor coil for split/window type AC as per exsting make/model complete all as specified and as directed.
S &F 3 core copper cable 4.0 sqmm for connection outer to inner unit of split type AC including taking down complete all as specified and as directed.
S & F copper tube 3/8" size thickness 0.7mm for connection to outer to inner unit for 1.5 TR /2.0 TR capacity split type AC including taking down complete all as specified and as directed.
S & F copper tube5/8" size thickness 0.7mm for connection to outer to inner unit for 1.5 TR /2.0 TR capacity split type AC including taking down complete all as specified and as directed.
S & F insulation cover for thermally insulated copper tube for 1.5 TR/ 2.0 TR capacity including taking down complete allas specified and as directed.
S & F Fliring valve inlet / outlet with nut,bolts,and necessary item for 1.5 TR/ 2.0 TR split type AC including taking down complete allas specified and as directed.
S & F good quality rubber pipe for condensing water for drain of size 20 mm dia including taking down complete all as specified and as directed.
S and F stand for outdoor AC Unit made up of power quoted MS angle including removal of old stand and making good the disturved surfaces all as specified and as directed.
S & F fan blade existing type for split /window type AC including taking down complete allas specified and as directed.
Supply only remote for split/window type AC as per site/ ordered model complete allas specified and as directed by Engr-in-charge.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron or steel earth lead MS flat 25 x 4 mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth wire protected by galvanised iron pipe 50 mm dia (light grade) and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work complete all as shown in elect plate No. 3 of SSR Part I, all as directed.
Taking down repairable exhaust fan of any size/sweep from existing position including taking down old connections wire complete all as directed and keep in safe custody for repairs and refixing the same on the same / different location with provision of new flexiable wire including cleaning of external surfaces & servicing the fan by dismantling complete greasing oiling and replacement of unserviceable parts as complete all as specified & directed Note :- Any parts needed to be replaced for satisfactorily running of exhaust fan shall be measured and paid separately under appropriate items.
S and F Louver for Exhaust fan of existing type including taking down old one all as specified and as directed.
Supply only Ball bearing suitable for ceiling/ exhaust fan of any sweep all as specified and as directed.
M&L for painting to exhaust fan of any sweep complete with synthetic enamel paint by spraying including filling cavities with fillar including necessary preparation of surface including refixing the same at site complete all as directed.
M&L for painting to ceiling fan of any sweep complete with synthetic enamel paint by spraying including filling cavities with fillar with necessary preparation of surface including hanging the ceiling fan and connecting up complete all as directed.
Taking down repairable ceiling fan of any size/sweep from existing position including taking down old connections wire complete all as directed and keep in safe custody for repairs and refixing the same on the same / different location with provision of new flexiable wire including cleaning of external surfaces & servicing the fan by dismantling complete greasing oiling and replacement of unserviceable parts as complete all as specified & directed Note :- Any parts needed to be replaced for satisfactorily running of celing fan shall be measured and paid separately under appropriate items.
Supply only Rubber bush of size 1 1/2 " dia x 1" thick for ceiling fan complete all as specified and as directed.
Supply only MS split pin size 2" x 1/8" for ceiling fan complete all as specified and as directed.
Dismantling burnt winding of ceiling fan (any size/ sweep/make) and taking out existing winding wire, and rewinding the same after proper cleaning with super enamelled copper winding wire as per existing gauge and turn to achieve the required RPM, cleaning of bearings, bushes etc as required and testing complete for fan suitable to operate on 230 V, single phase, AC supply, permanent capacitor type complete all as specified and directed. Note :- Replacement of unserviceable parts shall be measured and paid separately as supply only under appropriate item of this schedule , however labour element involved is included in this item.
Dismantling burnt winding of BLDC ceiling fan (any size/ sweep/make) and taking out existing winding wire, and rewinding the same after proper cleaning with super enamelled copper winding wire as per existing gauge and turn to achieve the required RPM, cleaning of bearings, bushes etc as required and testing complete for fan suitable to operate on 230 V, single phase, AC supply, permanent capacitor type complete all as specified and directed. Note :- Replacement of unserviceable parts shall be measured and paid separately as supply only under appropriate item of this schedule , however labour element involved is included in this item.
supply only PCB of BLDC fan of any make model/sweep/wattage complet all as specified and as directed.
Supply only remote of BLDC ceiling fan of any make/model/sweep/wattage complet all as specified and as directed.
Dismantling of burnt motor of exhaust fan of size 225 mm to 350 mm sweep, 230 V, single phase, AC supply, permanent capacitor type, taking out existing winding and rewinding the same with super enamelled bare insulated copper winding wire as per existing gauge and turn to achieve required RPM and testing complete all as directed . Note :- Replacement of unserviceable parts shall be measured and paid separately as supply only under appropriate item of this schedule, however labour element involved is included in this item.
Taking down repairable geyser of size 15-25 ltr from existing position including taking down old connections connecting pipe/wire complete all as directed and keep in safe custody for repair and refixing the same on the same / different location with provision of frastnut(as reqd) incl cleaning of external surfaces & servicing the geyser complete and replacement of unserviceable parts complete all as specified & directed Note :- Any parts needed to be replaced for satisfactorily running of geyser shall be measured and paid separately under appropriate items.
Supply & fixing heating element 1000w- 2000watt, ISI marked for geyser of any make complete all as specified and directed including taking out old one.
Supply & fixing Thermostat switch of geyser 230 volts, 30 degree to 90 degree centrigate temp. range complete all as specified and directed including taking out old one.
Supply & fixing Indicating lamp set for geyser of any make complete all as specified and directed including taking out old one.
Supply & fixing copper connection pipe set (pair) best quality of 600 mm long with brass screws for geyser of any make complete all as specified and directed including taking out old one.
S & F fusible plug of brass 15 mm bore suitable for any type geyser including taking down old one complete all as specified and directed.
S & F drain plug for wash out line made of brass suitable for any type geyser including taking down old one complete all as specified and directed.
S& F Air release valve 15 mm dia for geyser including taking down old one complete all as specified and directed.
Supply and fixed in repairs copper inner shell of electric geyser of capacity 25 litre, 2 mm thick sheet complete all as specified and as directed.
M&L for painting to geyser of capacity 15-25 ltr, complete with synthetic enamel white paint by spraying including filling cavities with fillar with necessary preparation of surface including hanging the same or different position and connecting up complete all as directed.
M and L for painting of LT panel, feeder pilar boxes,sheet metal enclosure and any other steel surfaces complete with two coats of power coated paint, (1st quality) of approved colour by spraying after removing all dust/rust/grease including preparation of surface all as specified and as directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm
supply and fixing ceiling fan complete with blades down rods and accessories 230 volts 1200 mm sweep white colour (with remote) min air delivery 210-CFM with service value 6 BEE 5 star rated with brushless direct current motor (BLDC)complete all as specified and as directed.
Supply and fixed in repairs wall mounted high speed fan of 400 mm sweep, including all fittings arrangment and all necessary fittings complete all as specified and as directed. Note:- Unserviceable fan shall be deposited to MES store yard of AGE E/M.
Supply,install and Commisioning of 100mm dia mild steel ERW pipe heavy class (Class-C) including cutting,screwing,welding suppoting pipe etc. complete with forged steel/butt welded fitting viz. Tees,bends,elbows,flanges etc including cutting holes and painting pipes,fittings & steel work with one one coat of primer and two or more coats of synthetic enamal paint of approved make and shade of dia 100mm including taking down old one complete all as specified and directed.
Material and labour for repair to the wall mounted fan of any make/model/sweep including removal of the exsting burnt out winding from slot, cleaning the slot throughly with suitable cleaning agent and spply slot insulation and rewinding with super enamelled copper conductor of same gauge and same tun and number as thet of exsting and connecting the coil suitable to operate on 230V single phase AC supply complet all as specified and as directed.
S & F Sluice valve PN 1.6 of dia 100 mm. complete as specified and as directed.
S& F Aparture plate(as per sample) for geyser capacity 25ltr including taking down old one complete all as specified and directed.
S&F Plug top with indicator 16 A, including taking down old one complete all as specified and directed.
Supply and fixed in repairs electronic driver for LED surfacelight/spot light as per exsting capacity including fittings complete all as directed and as specified
S&F indicator LED phase lamps 03 Nos. (R,Y,B) incl taking down old one complete all as specified and directed.
S & F Voltmeter 0-500 Volts digital type incl taking down old one complete all as specified and as directed.
S & F Ammeter 0-100 digital type incl taking down old one complete all as specified and as directed.
Repair/maintenance and fitment of existing water cooler /Refrigerator/RO Water Purifier of existing capacity including repair/replacement of spares/cartridge with proper cleaning of water storage space,cooling coil,supply and charging of refrigerent maintenance of Compressor etc for proper functioning complete all as specified and as directed.
S & F compressor for Refrigerator of capacity 290 ltr as per existing including charging gas complete including taking down old one complete all as specified and as directed.
Supply and fixed in repairs hermeatically sealed unit of compressor for water cooler of capacity 120 litre including charging of gas R-22 complete all as specified and as directed.
Supply and fixing single phase KWh meter with LCD display,5-40A with box,including connection wire and grouting of nuts,bolts complete all as specified and directed.
Material and Labour for Servicing of Transformer 11/0.415 kV of capacity 400 KVA Natural Oil Cooled Transformer including taking proper shutdown from HT side and disconnecting all HT and LT cables, checking drain plug and replacing where required, checking oil level indicator and replacing where required, checking of silica gel breathers, claening and polishing both side HT & LT bushing and studs, bushing rod, servicing of tap changing gears by cleaning and polishing tapping contact points, rectify the oil leakages issues, if noticed any from the entire body of the transformer, cleaning all sludges from main oil tank and conservator tank and removal off the site, manual cleaning the cores and windings from sediments and foreign particles deposited on cores/ windings/ body, replacing the gaskets and bolts/Nuts as reqd for under mentioned capacities of transformers. Note 1: - Inspection of transformer shall involve :- (a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts,etc. (b) Checking all brazings, joints, tap heads, gaskets and connection joints. (c) Checking all terminations / connections inside/ouside the transformer. (d) Checking of off load tap changer assembly, checking the moving and fixed contacts for contact wear and connection to winding. (e) Conducting the test on core and windings as per IS like ratio, magnetic imbalance, short circuit, IR Value, High Voltage Test etc. in presence of Engr-in-Charge.Note 2: - The materials used rewinding of primary & secondary coils, Iron Core, bushes studs HT/LT, bushing rod HT/LT, buchholtz relay, Gaskets set for servicing will be measured and paid under separate item. Dehydration and topping up of transformer oil will be measured and paid under separate item but must be done at the time of servicing. Other minor spares/ materials not mentioned in the schedule viz drain plug, M seal monoplast kit, bolts and nuts, materials and and tools used for servicing, lowering/ lifting of transformer, tools required for cleaning or core/ windings, tools required for cutting of gaskets etc deemed to be included in the quoted rate.Note 2: - The materials used rewinding of primary & secondary coils, Iron Core, bushes studs HT/LT, bushing rod HT/LT, buchholtz relay, Gaskets set for servicing will be measured and paid under separate item. Dehydration and topping up of transformer oil will be measured and paid under separate item but must be done at the time of servicing. Other minor spares/ materials not mentioned in the schedule viz drain plug, M seal monoplast kit, bolts and nuts, materials and and tools used for servicing, lowering/ lifting of transformer, tools required for cleaning or core/ windings, tools required for cutting of gaskets etc deemed to be included in the quoted rate. Note 2: - The materials used rewinding of primary & secondary coils, Iron Core, bushes studs HT/LT, bushing rod HT/LT, buchholtz relay, Gaskets set for servicing will be measured and paid under separate item. Dehydration and topping up of transformer oil will be measured and paid under separate item but must be done at the time of servicing. Other minor spares/ materials not mentioned in the schedule viz drain plug, M seal monoplast kit, bolts and nuts, materials and and tools used for servicing, lowering/ lifting of transformer, tools required for cleaning or core/ windings, tools required for cutting of gaskets etc deemed to be included in the quoted rate.Note 2: - The materials used rewinding of primary & secondary coils, Iron Core, bushes studs HT/LT, bushing rod HT/LT, buchholtz relay, Gaskets set for servicing will be measured and paid under separate item. Dehydration and topping up of transformer oil will be measured and paid under separate item but must be done at the time of servicing. Other minor spares/ materials not mentioned in the schedule viz drain plug, M seal monoplast kit, bolts and nuts, materials and and tools used for servicing, lowering/ lifting of transformer, tools required for cleaning or core/ windings, tools required for cutting of gaskets etc deemed to be included in the quoted rate.
Material and Labour for Servicing of TrTransformer 11/0.415 kV of capacity 200 KVA. Make of Transformer - Volt Amp Natural Oil Cooled Transformer including taking proper shutdown from HT side and disconnecting all HT and LT cables, checking drain plug and replacing where required, checking oil level indicator and replacing where required, checking of silica gel breathers, claening and polishing both side HT & LT bushing and studs, bushing rod, servicing of tap changing gears by cleaning and polishing tapping contact points, rectify the oil leakages issues, if noticed any from the entire body of the transformer, cleaning all sludges from main oil tank and conservator tank and removal off the site, manual cleaning the cores and windings from sediments and foreign particles deposited on cores/ windings/ body, replacing the gaskets and bolts/Nuts as reqd for under mentioned capacities of transformers. Note 1: - Inspection of transformer shall involve :- (a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts,etc. (b) Checking all brazings, joints, tap heads, gaskets and connection joints. (c) Checking all terminations / connections inside/ouside the transformer. (d) Checking of off load tap changer assembly, checking the moving and fixed contacts for contact wear and connection to winding. (e) Conducting the test on core and windings as per IS like ratio, magnetic imbalance, short circuit, IR Value, High Voltage Test etc. in presence of Engr-in-Charge.Note 2: - The materials used rewinding of primary & secondary coils, Iron Core, bushes studs HT/LT, bushing rod HT/LT, buchholtz relay, Gaskets set for servicing will be measured and paid under separate item. Dehydration and topping up of transformer oil will be measured and paid under separate item but must be done at the time of servicing. Other minor spares/ materials not mentioned in the schedule viz drain plug, M seal monoplast kit, bolts and nuts, materials and and tools used for servicing, lowering/ lifting of transformer, tools required for cleaning or core/ windings, tools required for cutting of gaskets etc deemed to be included in the quoted rate.Note 2: - The materials used rewinding of primary & secondary coils, Iron Core, bushes studs HT/LT, bushing rod HT/LT, buchholtz relay, Gaskets set for servicing will be measured and paid under separate item. Dehydration and topping up of transformer oil will be measured and paid under separate item but must be done at the time of servicing. Other minor spares/ materials not mentioned in the schedule viz drain plug, M seal monoplast kit, bolts and nuts, materials and and tools used for servicing, lowering/ lifting of transformer, tools required for cleaning or core/ windings, tools required for cutting of gaskets etc deemed to be included in the quoted rate. Note 2: - The materials used rewinding of primary & secondary coils, Iron Core, bushes studs HT/LT, bushing rod HT/LT, buchholtz relay, Gaskets set for servicing will be measured and paid under separate item. Dehydration and topping up of transformer oil will be measured and paid under separate item but must be done at the time of servicing. Other minor spares/ materials not mentioned in the schedule viz drain plug, M seal monoplast kit, bolts and nuts, materials and and tools used for servicing, lowering/ lifting of transformer, tools required for cleaning or core/ windings, tools required for cutting of gaskets etc deemed to be included in the quoted rate.Note 2: - The materials used rewinding of primary & secondary coils, Iron Core, bushes studs HT/LT, bushing rod HT/LT, buchholtz relay, Gaskets set for servicing will be measured and paid under separate item. Dehydration and topping up of transformer oil will be measured and paid under separate item but must be done at the time of servicing. Other minor spares/ materials not mentioned in the schedule viz drain plug, M seal monoplast kit, bolts and nuts, materials and and tools used for servicing, lowering/ lifting of transformer, tools required for cleaning or core/ windings, tools required for cutting of gaskets etc deemed to be included in the quoted rate.
Dehydration & filteration of transformer oil by disconnecting the device from supply and draining out the complete oil, filtering the dirt, sludge and dehumidifying by heating the same and raising the Breakdown voltage level 60 KV at 2.5 mm gap and testing and recording the result for three times in specified interval including pouring the oil in transformer tank and charging the same to restore supply complete all as specified and as directed.
Supply & filling only Transformer Oil for topping up the level( after necessry disconnection and earthing both winding) with grade as per IS : 335 complete incl opening the tank cover and refixing the same and charging the transformer to the supply voltage complete all as specified and as directed including taking out old one. Note : Die electric strength of the oil shall be ensured not less than 60 KV before filling.
Supply only silica gel breather including initial fiiling with required quantity of silica gel for transformers of 200 and 400 KVA capacities all as specified and as directed.
Supply only procelain transformer bushing with bushing rod (studs) made out of brass/ gun metal with threading and of suitable length /size as per existing including metal rings, bolts, washers, rubber rings, etc for LT secondary side of existing 11/0.433 kV step down transformer of capacity 315 KVA and 400 KVA complete all as specified and as directed.
Supply only in replacement of Oil temperature guage ranging from 0 to 150 degree C suitable for existing 11/0.433 kV step down transformer of capacity 200 KVA and 400 KVA complete all as specified and as directed.
Supply only best quality good oil resistant gasket sheet suitable for oil cooled transformer as per IS: 4253 including cutting to shape as per existing size of transformer top covers and side covers all as specified and as directed.
Material and labour for dismantling, lowering lifting of transformer and transporting it to worshop for rewinding work and taking back to the site after rewinding and resinstalling the transformer complete all as specified and directed by the Engr -in- charge.
Material and labour for rewinding of existing step down 11/.433 KV transformer HT / LT coil of capacity 200/400 KVA using super enamelled copper wire of suitable guage and specifications including super enamelled iron core as per existing guage and specifications, including heating up, drying, varnishing, re-insulating with insulation of necessary class complete all as specified and directed by the Engr -in- charge.
Material for painting of transformers with two coats of synthetic enamel paint of approved colour and writing MES No with Capital letters after removing of old paints by paint removing chemicals and mild scrapping for transformers of 315 and 400 KVA capacities all as specified and as directed.
Maintenance of Vaccum circuit Breaker, make: PASCAL, 6.0 KV Grade, 200 to 630 Amps by licensed electrician including the following:- (a) Switiching off VCB and conforming that supply to incomming end is properly disconnecte. (b) Opening covers of the VCB and visual checking of epoxy housing and all parts for rust and wear. (c) Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths. (d) Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable. (e) Checking of PTs, CTs control circuits, closing and tripping coil and all other parts. (f) Replacement of detective or less reliable parts from OEM (to be measured and paid separately). (g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections. Note : 1. After servicing of VCB, Health check up reports will be submitted.
Repair/ maintenance of HT Oil Isolating switch(VLE) unit of 200 Amps capacity, 3 phase manually operated fixed/draw out ID type oil isolating switch 11KV/200A, MEI make at Teesta building by removing the breaker from panel discmantling carefully its parts/accessories. Cleaning the dust/impurities and accumulations etc blowering/brushing cleaning properly with CRC-26 spray to remove rust including supply of gasket, oil seal, nut & bolts, washers, reassembles, the parts /accessories and fix in same position and connection, testing for satisfactory operation all as directed. (Note: Maintenance /repairs shall be carried out by trained technicians/mechanic (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate)
Removing existing old paint by scraping from Vacuum Circuit Breaker/VLE and applying two coats of synthetic enamel paint (1st quality) by spraying including writing SM/MES No, capacity in white paint complete all as specified and directed.
Supply and replacement of heating coil of Vacuum Circuit Breaker including taking down old unserviceable all as specified as directed .
Supply and replacement of Trip Coil Box Assembly with Plunger - without Coil as per existing type and size complete all as specified and as directed.
Supply and replacement of Busbar Support Insulator complete all as specified and as directed.
Supply and replacement of Release/Closing Coil complete all as specified and as directed.
Supply and replacement of HRC Fuse-PT HT Side VTF 6.6, 3A complete all as specified and as directed.
Supply and replacement of Potential transformer of Vacuum Circuit Breaker (Model and type as per sample) including taking down old unserviceable all as specified as directed .
Supply and replacement of current transformer of Vacuum Circuit Breaker (Model and type as per sample) including taking down old unserviceable all as specified as directed .
Supply and replacement of Power pack unit of Vacuum Circuit Breaker (Model and type as per sample) including taking down old unserviceable all as specified as directed .
Calibration of relays of Vacuum Circuit Breaker with secondry injection unit and check the healthiness of relays and adjust the realy settings as per ground requirements complete all as specified and as directed. Note: Report of calibration to be submitted to the department.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
Disconnecting, repair and maintenance of APFC panel and replacement of internal wiring by new, checking and taking out defective unserviceable parts and replaced the same to make serviceable connection, testing etc. as directed. Note: (i) Maintenance / repairs shall be carried out by trained technicians/mechanic under supervision of qualified electrical technician. (ii) All repairs shall be carried out at site only. (iii) Spare / parts shall be measured and paid seperately as ''supply only''
Supply only 5 to 15 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, including taking down old unserviceable all as specified as directed.
Supply only 20 to 50 KVAR capacitor, box series type-LTXL-Ultra heavy duty, 440V, including taking down old unserviceable all as specified as directed.
Supply only APFC Relay meter (8 Steps) complete including taking down old unserviceable all as specified as directed . .
Supply only capacitor duty contractors of 5 KVAR rating, type MO C5, size Fr 1 including taking down old unserviceable all as specified as directed .
Supply only capacitor duty contractors of 10 KVAR rating, type MO C10, size Fr 1 including taking down old unserviceable all as specified as directed .
Supply only capacitor duty contractors of 20 KVAR rating, type MO C20, size Fr 1 including taking down old unserviceable all as specified as directed .
Supply and fixing MCCB, 16-125 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed.
Supply and fixing MCCB, 160 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed.
Supply and fixing MCCB, 200 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for straight though heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm sqmm cutting of old jointing material including taking down old one complete all as specified and as directed.
M & L Cable jointing kit for 1100 V grade cable for straight though (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185-300 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed.
M & L Cable jointing kit for 1100 V grade cable for straight through (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-150 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed.
M & L Cable jointing kit for 1100 V grade cable for straight through (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5/4.0 core XLPE armoured aluminium conductor cable of size 25-50 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 4 coreincluding taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 25 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS IS 7098 (Part- I)with aluminium conductor of cross sectional area 35 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 70 Sqmm 3.5 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 11000 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- II) with aluminium conductor of cross sectional area 95 Sqmm 3 core including taking down old one complete all as specified and as directed.
Supply only , 1100 volts grade PVC insulated and FR PVC round sheathed, copper conductor (flexible) industrial cable of cross sectional area 10 Sqmm 4 core conforming to IS 694 with suitable size of lugs (02 sets) on a drum with handle with movable trolley (one for 100 RM length) complete all as specified and as directed.
Supply & fix hot dip galvanized steel perforated cable tray with tray cover rectanglar type (rigid & felxible) of suitable width ranging from 4 inch to 8 inch to be fixed on wall complete all specified and as directed.
M&L for painting of perforated cable tray and cover of width 4-8 inch with two coats of powder coated paint (1st quality) of approved colour by brush after removing all dust/rust all as specified and as directed.
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
M&L for sand filling for cable cushioning including spreading and levelling as directed. Note : Thickness for sand shall be measured after punning down.
M & L Bricks, common burnt clay building bricks, old size sub-class ‘B’ designation 75 laid perpendicular to the axis of cable,abutting 10 mm gap in between complete all as specified and directed.
M&L for re- laying old brick perpendicular to the axis of cable,abutting 10 mm gap in between complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover class HV, Type 1, flat, size 300mmx 180mm x 40mm all as specified and as directed.
M & L Tubes, 'light grade', galvanised,with all fitting,laid in trenches/fixed on Wall 80 mm dia for protection of cable all as specified and directed.
M&L for road cutting for laying of LT UG cable /Galvanised Iron Pipe complete all as specified and directed.
M&L plain cement concrete 1:3:6 Type C1 (using 20 mm graded crushed stone aggregate) as in coping, roof kerb or similar work, rounded or chamfered on edges including necessary form work including demolition old one complete all as specified and directed.
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm galvanised iron strip complete incl saddles if required.
M&L for PCC Pit for earthing made up of PCC 1:2:4 type C2 and RCC cover 40 mm thick with 8 mm bar 15 c/c including water pipe with funnel and wire mesh and also includes excavation and earth work all as specified in SSR Part 1 2009.
M&L for painting of LT panels, APFC pannel, feeder pillar boxes, junction boxes, sheet metal enclosure and any other steel surfaces complete with two coats of powder coated paint (1st quality) of approved colour by spraying after removing all dust/rust /grease including preparation surface all as specified and directed.
M&L for shifting of LT panel from one location to another by disconnecting and/or terminating old connection, removing foundation PCC and fixing at new location if required all as specified and as directed. Note: 1. Transportation cost deemed inclusive of the quoted rate. 2. PCC for foundation shall be measured and paid separately.
Supply and fix sheet steel enclosure 4 way TPN DB with 200 amps bus bar with provision for TPN MCB as incomer, double door type complete all as specified and directed. Make: Legrand/ABB/L&T/Siemens/Schenieider.
Supply and fix MCB TPN 240V, 16-32 Amps capacity 'C' Curve complete all as specified and directed.
Supply and fix MCB TPN 240V, 40-100 Amps capacity 'C' Curve complete all as specified and directed.
Supply only Aluminium cable lugs (each set of 16) suitable for XLPE armourded cable for cable size of 16-300 sqmm with 3.5/4.0 core all as specified and as directed.
Supply only Aluminium ferrules (each set of four) suitable for XLPE armourded cable for cable size of 16-300 sqmm with 3.5/4.0 core all as specified and as directed.
Supply only plain rubber HT safety gloves suitable for 11KV supply protection, reusable type (in pair) of suitable size all as specified and as directed.
Supply and fix in repairs on load change over switch with phase barriers, handles with door interlocking kit with enclosure, 4 pole, 250 amps, I-O-II complete all as specified and as directed by Eng-in-charge.
Taking down old LED street light/secirity light/flood light/post top lantern/ garden light fitting of any size and any capacity from pole/ bldg/gate/garden with disconnecting the existing line for pole and cleaning the carbon of existing cable of pole box, checking driver kit replace unserviceable items and light fitting connector and refix the same on pole and testing complete all as specified and directed by Engr-in-charge. Note-LED Driver required will be measured and paid seperately.
Supply and fix GI Bracket made of 32/40/50 mm dia MS pipe medium grade 1.5mtr long suitable for street light on steel / RCC pole as per site requirement including suitable GI nut, bolt and clamps complete accesseries all as specified and directed Including taking out old one.
Supply and fix MS Clamp for street light with dimension suitable to firm grip on pole and PVC conduit and fix with MS nut and bolts complete including taking down old unserviceable one all as specified and as directed.
M&L preparation of old painted surface above the planting depth and PCC coping of steel tubular LT pole of upto 9.00 metre length with white wash including painting with synthectic enamelled MS clamps ,cable protection pipe bracket fitted with street light fittings etc by scraping with steel wire brush and applying two coats, of aluminium paint to external surface of poles MS cross arms MS clamp, cable protection pipe etc to give even shade and numbering of poles complete all as specified and as directed by Engr-in –charge.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 4 core including taking down old one complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS 7098 (Part- I)with aluminium conductor of cross sectional area 16 Sqmm 4 core including taking down old one complete all as specified and as directed.
M&L for re- laying old brick perpendicular to the axis of cable,abutting 10 mm gap in between complete all as specified and directed.
M & L Tubes, 'light grade', galvanised,with all fitting,laid in trenches/fixed on Wall 50 mm dia for protection of cable all as specified and directed.
M&L for road cutting for laying of LT UG cable /Galvanised Iron Pipe complete all as specified and directed.
M&L plain cement concrete 1:3:6 Type C1 (using 20 mm graded crushed stone aggregate) as in coping, roof kerb or similar work, rounded or chamfered on edges including necessary form work including demolition old one complete all as specified and directed.
Refixing of hanging/loosen earth strip/down conductors of Cu/GI/Al with replacement of broken procelain connector and proper clamping, saddling and connected accessories at the original location complete all as directed. Note: Price of porcelain connector any scaffloding required deemed inclusive of quoted rate.
Supply & fix Air termination single pointed aluminum rod 12 mm dia and 300 mm long including taking down old unserviceable one complete all as specified and as directed.
Supply & fix Test point terminal block made of gunmetal or phosphorus bronze of size 75 x 75 x 25 mm, drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed including taking down old unserviceable one.
M&L for indoor LT Panel cubicle compartmentalized type panel of suitable size with 1.6 mm thick CRCA sheet with 2.0 mm thick gland plate suitable for IP 52 protection, phosphate powder coated in Siemens grey colour with suitable size of Al Bus bar with heat colour coded sleeve with provision of cable entry from bottom & top complete with all fittings and fixing arrangement all as specified and as directed with following specifications:- Note: 1. Switchgears and metering equipment will be provided by department. 2. Busbars and internal wiring and connector deemed inclusive of the quoted rate. 3. Any minor spares deemed inclusive of the quoted rate. 4. PCC for foundation deemed inclusive of the rate.
Supply and fix electronic driver for LED flood light/street light as per existing capacity including fitting arrangements and taking down old one complete all as specified and as direted.
Supply and fix electronic driver for LED bollard light/post top lantern/spot light as per existing capacity including fitting arrangements and taking down old one complete all as specified and as direted.
Supply and fix flood LED light in 250 W in static mono colour or as specified by Engr-In-Charge with IP 66 protection with all fittings and accesories complete all as specified and as directed.
M&L for Decorative post top lantern for 360 degree , 20 Watt, indirect light suitable for pipe 50mm dia including connection from connector to switch including taking down old one complete all as specified and as directed.
S & F of Flood light 200 W with minimum system efficacy 100 lum/W including electronic driver and all fixing arrangement including taking down old one all as specified and as directed.
Supply and fixing in repair LED street light fitting 70 watt 230 V AC outdoor type with high pressure die cast aluminiun housing and heat resistant complete with driver, lamp bracket with impact and corrosin resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Eng-in charge.
S&F Sign Board with details made of acrylic sheet board waterproof for display with 2.5 ft height x 6 ft width with 12 mm thickness fixed with SS clamp complete all as specified and as directed. Note: Subject material to be provided by the department.
S & F water supply/electric supply/fire fighting network diagram chart acrylic PVC sheet with size 5 ft x 3ft with 4 mm thickness complete all as specified and directed by engr-in-charge.
Supply and fix sheet steel enclosure 4 way TPN DB with 200 amps bus bar with provision for TPN MCB as incomer, double door type complete all as specified and directed.
Supply and fix MCB TPN 240V, 16-32 Amps capacity 'C' Curve complete all as specified and directed.
Supply and fix MCB TPN 240V, 40-100 Amps capacity 'C' Curve complete all as specified and directed.
Supply and fix Contactor ML-2, 3 pole 240 Volts including taking down old burnt/unserviceable one complete all as specified and directed.
Supply and fix main CTs as per existing capacity including taking down old burnt/unserviceable one complete all as specified and directed.
Supply & fix street light timer suitable for street light control complete all as specified & directed including taking down old one all as specified and directed.
Supply and fix SMC junction box fix to wall/pole , Size - 300 x 200 mm, with provision of cable incoming and outging including cable glands and 4 Pole PVC Connector all fittings including taking down old unserviceable one all as specified and as directed.
M&L for wiring with two runs of 1.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed copper conductor FRLS cable upto and including 1100 V grade drawn through PVC rigid conduit medium grade fixed to wall / ceiling / pole etc including one run of 1.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed copper conductor FRLS cable as earth wire and duly connected to common earth point all as specified and directed including taking out old cables. (Note :-(i) One run of PVC rigid conduit with all fittings/accessories and Two runs of 1.5 sqmm single core cable and one run of 1.5 sqmm earth continuity wire to be measured as one length).
Supply and fixing in repair LED street light fitting 70 watt 230 V AC outdoor type with high pressure die cast aluminiun housing and heat resistant complete with driver, lamp bracket with impact and corrosin resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Eng-in charge.
Supply and fixing in repair LED bollard light in cylindrical shape with opal acrylic diffuser and IP66 protection including taking down old u/s one complete all as specified and as directed.
Supply and fixed in repairs 16 A plug top with in-built RCD, RESET function is for switching on the applicance after its shut down, which trips the connected appliance in case any detention of current leakage and prevents chancesof any electrical shock
Supply and laying double wall corugated pipe internal dia 75 mm dia, IS 16205-Part-24-2018 with coupler, bends etc for mechanical protection of LT cables for relaying new cables complete all as specified and directed
HIGH HILLS ENTERPRISE
M/s Santosh Industrial Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .