| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC M S SATHYAM ENGINEERING KOOTHANKUZHI THIRUVALLUR TAMIL NADU 600 062 | THIRUVALLUR | THIRUVALLUR | TAMIL NADU | 600062 | ₹25.9 L Quoted ₹26.0 L | L1 | Accepted-AOC ACCEPTED BEING L1 |
| 2 | L2₹26.1 LRejected-AOC 9 8 B THENGUMTHARAVIL MLA ROAD PANANGAD PO KOCHI 682506 | KOCHI | ERNAKULAM | KERALA | 682506 | ₹26.1 L | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| 3 | L3₹28.8 LRejected-AOC D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹28.8 L | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| 4 | L4₹32.2 LRejected-AOC | ₹32.2 L | L4 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected due to No appropriate category as mentioned in NIT |
| Sl No | Description | Qty | Unit | Sathyam engineering L1 | T.I.John and Sons L2 | AYYAPPA CONSTRUCTIONS L4 | SHIKHARA PROJECTS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix Analog Addressable Fire Alarm Panel (Wall Mount, 4 Loops, Premium License) both analog addressable and conventional technologies, with a modular design and capable of connecting periphery devices in stub or loop topologies. Each peripheral (e.g., fire detectors, manual call points) shall be represented as single loop elements, and logical zones shall be grouped according to the building infrastructure.
(a) Modular Design: Solid metal housing to house panel hardware, cabling, and batteries. Functional modules (addressable loops, conventional zones, inputs, outputs, serial interfaces) plugged into slots on a rail. Modules are hot-swappable (replaceable without power interruption or reprogramming).
(b) Capacity: Supports up to 4 analog addressable loops, each capable of managing up to 1,016 loop elements. Can handle up to 512 automatic fire detectors and manual call points as per EN54 part 2. Flash memory stores configuration, settings, and firmware.
(c) Panel Networking: Capable of connecting up to 32 panels, keypads, and information servers. Supports several network topologies (CAN loop, Ethernet loop, redundant Ethernet and CAN loop). Maximum distance between nodes: 1 km (can be extended up to 40 km with fiber optic media converters).
(d) Alarm Indication: 7” touchscreen display with a minimum resolution of 800x480 pixels, clear, intuitive graphical interface. Alarm messages will show type, triggering element, and location. Acoustical signal (min 65 dB) to alert operators.
LED indicators (Red for fire, Yellow for fault, Green for idle) to show system status.
(e) Alarm Verification: Features day/night modes for alarm verification, with delayed or immediate responses based on operator presence. Verification timer (max 6 minutes) for manual confirmation of alarm location. Automatic activation of signaling and fire protection equipment if no action is taken in time. | 1 | Each Job | 2,95,800 ₹3.0 L | 6,50,000 ₹6.5 L | 3,00,000 ₹3 L | 2,97,000 ₹3.0 L |
| 1.01(f) Evacuation Zones & Outputs: Provides an overview of all evacuation zones and outputs. Operators can start evacuations and activate fire protection equipment manually. (g) Operator Functions: Multiple operator controls: reset detectors, silence alarms, toggle between day/night modes, disable/enable devices, adjust sensitivity, and review event history. Programmable function keys for quick access to frequently used functions. History log of up to 10,000 messages, exportable as PDF or CSV. | |||||||
| 1.02(h) Automatic Controls: Calendar-based control system for functions like activating outputs, adjusting detector sensitivity, and toggling day/night modes. Ability to define up to 19 time control programs and 20 timer channels. (i) Operator Management: Supports up to 200 operator profiles, with 4 permission levels. User login is via 8-digit codes, ensuring secure access. Built-in language support for English and multiple languages (e.g., German, French, Spanish). (j) Self-Monitoring & Remote Service: Continuous self-monitoring of hardware and software. Real-time fault diagnosis with detailed information available via the user interface. Periodic diagnostic data transmitted to a remote server for troubleshooting. | |||||||
| 1.03(k) Voice Alarm System Integration: Ethernet interface for integration with a certified EN54 part 16 voice alarm system. Pre-recorded announcements, customizable evacuation zones, and fault diagnostics. (l) Building Management System Integration: Ethernet interface to a BMS with OPC-server for real-time communication and control functions (reset detectors, silence alarms, disable devices, adjust sensitivity). (m) Power Supply: 24V DC power supply with 6A capacity, backed by 26 Ah batteries for 72 hours of quiescent power + 30 minutes during alarms. Automatic battery testing with fault alerts if needed. (n) Regulations and Certifications: Complies with EN 54-2:1997 + A1:2006, EN 54-4:1997 + A1:2002 + A2:2006, and other fire protection regulations. Certified by VdS, BOSEC, CNBOP, and other authorities. (o) Technical Specifications: Electrical: Input voltage: 100-240V AC, Frequency: 50-60 Hz, Power source: PS 3. Mechanical: Housing material: Painted sheet steel, flammability rating: UL94-V0. Environmental: Operating Temp: -5°C to 60°C, Storage Temp: -20°C to 60°C, Humidity: up to 95% non-condensing complete all as specified and directed Make: BOSCH/FIRE THORN/GAMEWELL | |||||||
| 2.00 | Supply and fix microprocessor-based loop modules capable of supporting up to 254 devices with a line length of up to 1600m/3000m based on cable type. Modules must be hot-pluggable, encapsulated, include an LED test button, and have visible front fascia for fault identification and Loop cards should be replaceable without requiring reprogramming combination complete all as specified and directed.
Make: BOSCH/FIRE THORN/GAMEWELL | 1 | Each Job | 88,500 ₹88,500 | 75,000 ₹75,000 | 70,000 ₹70,000 | 70,000 ₹70,000 |
| 3.00 | Supply and fix EN54/VdS-certified addressable double-action MCPs along with Key (break glass with push button) featuring alarm LED indication and inbuilt fault isolators.MCP must include onboard electronics for addressing and support both surface and flush mounting complete all as specified and directed.
Make: BOSCH/FIRE THORN/GAMEWELL | 8 | Each Job | 7,600 ₹60,800 | 7,500 ₹60,000 | 5,050 ₹40,400 | 4,500 ₹36,000 |
| 4.00 | Supply and fix EN54/VdS-certified addressable loop-powered fire alarm sounders with inbuilt fault isolators, programmable tones, and <5mA current consumption. Sounders must support synchronization, volume adjustment via FACP, and dual functionality as strobes or detector bases. Includes all necessary accessories for installation and power complete all as specified and directed.
Make: BOSCH/FIRE THORN/GAMEWELL | 8 | Each Job | 8,500 ₹68,000 | 8,500 ₹68,000 | 5,050 ₹40,400 | 4,500 ₹36,000 |
| 5.00 | Supply and fix EN54/VdS-certified addressable loop-powered strobes with red flash (≥1Hz), minimum 2 cd output, and ≤10mA current consumption.Strobes must include inbuilt fault isolators (or external if not integrated), support DIP switch or panel addressing, and integrate into detection loops only. Capable of functioning as sounder cum strobe, with ease of testing, drill programming, and maintenance via the FACP complete all as specified and directed.
Make: BOSCH/FIRE THORN/GAMEWELL | 8 | Each Job | 7,500 ₹60,000 | 9,000 ₹72,000 | 5,250 ₹42,000 | 5,000 ₹40,000 |
| 6.00 | Supply and fix EN54/VdS-certified, addressable loop-powered monitor modules with 2 independent inputs for monitoring third-party devices.Modules must support contact, voltage, and EOL resistor monitoring with programmable open/close contact logic and include inbuilt or external fault isolators. Addressable via DIP switch or panel, and configurable per site application requirements complete all as specified and directed.
Make: BOSCH/FIRE THORN/GAMEWELL | 2 | Each Job | 8,500 ₹17,000 | 4,800 ₹9,600 | 6,200 ₹12,400 | 6,000 ₹12,000 |
| 7.00 | Supply and fix Supply of standalone AI-powered flame and smoke detection units with real-time video analytics, designed for early and reliable detection in indoor and sheltered outdoor environments.
(a) Core Detection Capabilities
AI-Powered Video Analytics: Detect flame (≥1.1% frame width) and smoke (≥1.6% frame width) using embedded AI algorithms.
Operating Conditions: Minimum illumination of 1 Lux, infrared-assisted detection at 0 Lux, and up to 20,000 Lux ambient light.
Detection Standards: Complies with EN54 fire detection standards (TF1–TF8).
Intelligent Configuration: Adjustable verification time, detection area, sensitivity, and exclusion zones.
(b) AI-Based Object Detection. Differentiation: Object-based logic to distinguish fire-related elements from background noise. Real-Time Metadata: Instant alarms, historical data storage, and post-event forensic search.
(c) System Features. Storage: Dual microSD slots, supports up to 2 TB for local event storage.
Data Transmission: H.264/H.265 encoding, 60 fps video and analytics streaming.
(d) Power & Communication. Power Options: 12 VDC, 24 VAC (±10%), or PoE.
Power Consumption: 7–16 W depending on power source.
I/O Interfaces: Audio, Alarm, USB, Fiber, Power Out.
(e) Physical and Environmental Specifications. Enclosure: IP66, IP67, IP6K9K, with surface mounting capability. Operating Temperature: PoE: -40°C to +60°C, Direct Power: -50°C to +60°C, Extended: Up to +74°C. Humidity: Operation: 5%–93% RH, Storage: up to 98% RH.
(f) Standards & Compliance. Fire Detection: EN54 and VdS certified.
Environmental: NEMA Type 4X.
Inter-operability: ONVIF Profiles S, G, T, M complete all as specified and directed.
Make: BOSCH/FIRE VU/DEF | 2 | Each Job | 5,85,600 ₹11.7 L | 3,50,000 ₹7 L | 8,95,000 ₹17.9 L | 8,00,000 ₹16 L |
Updated dates
Tender Value
₹27.3 L
EMD Value
₹54,600
Closing Date
20 Nov 2025, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
PROVISION OF FIRE ALARM SYSTEM AT MH2 BSF AND 01 NO OF 10HP MONOBLOC PUMPSET FOR EXISTING STATIC WATER TANK NEAR ATC NEW GARRAGE AND AC AT BATTERY WORKSHOP AT E HANGAR AND P8I STORE AT INS RAJALI ARAKKONAM
2025_MES_734267_2
8475E8
Open Tender
Electrical and Maintenance Works
180 days
Garrison Engineer M NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹54,600
Yes
26 Feb 2026
30 Oct 2025
22 Nov 2025
30 Oct 2025
20 Nov 2025
6 Nov 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
Tenderdocuments8475R.pdf
Tender Documents • 0.80 MB
BOQ_826086.xls
BOQ • 1.62 MB
NIT8475R.pdf
Additional Documents • 0.37 MB
Download all tender documents and submit your bid