Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.0 LAccepted-AOC H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 1 | Accepted-AOC REASONABLE AND LOWEST | |
| 2 | 2₹22.9 L+₹2.9 L (14.6%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹25.9 L+₹5.9 L (29.6%)Rejected-Finance A 102 GOLDEN SAND APARTMENTS GAZIPUR DHAKOLI ZIRAKPUR PB 160104 | ZIRAKPUR | S A S NAGAR | PUNJAB | 160104 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹28.8 L+₹8.8 L (44.0%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | 4 | Rejected-Finance NOT LOWEST |
Tender Value
₹22.6 L
EMD Value
₹45,000
Closing Date
13 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA SANGRUR ROAD PATIALA CANTT
ADDN/ALTN AND UPGRADATION OF THREE PHASE SUPPLY IN LIEU OF SINGLE PHASE IN NEW KSE AREA AND MES COLONY OLD CANTT ARAE UNDER GE(N) PATIALA AT PATIALA MIL STN
2021_MES_421960_1
GE(N)/PAT-43/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
PATIALA
1.All contractors enlisted with MES in Class E above and category b i subject to the remarks w r t satisfactory performance in respect of works in hand
2.The firms not enlisted with MES shall meet the enlistment criteria of Class E MES co
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹45,000
Yes
6 Apr 2021
13 Feb 2021
15 Mar 2021
13 Feb 2021
13 Mar 2021
27 Feb 2021
15 Feb 2021 - 20 Feb 2021
60 days
Amount
Excavation in trenches in soil n.exe 1.5 mtr wide and 1.5 mtr deep for laying of cables including getting out complete all as specefied and directed. (193.33+388.8)
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specefied and directed. (124.80+261.36)
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point. (68.54+127.44)
Supply and filling Dry clean sand for sand cushioning of underground cable complete all as specified and as directed. Note:-Sand shall be measured after punning down. (116.64 + 55)
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Boring under roads/hardstanding for passing of cable with GI pipe all as specified and directed
Cutting of walls/hardstanding for laying cable including match with surface all as specified and directed.
M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection all as specified and directed.
Material and labour for Boring of holes under road, pavement, hard standing without cutting the road including light grade GI Pipe of 80 mm dia suitable for passing throug of UG cable all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover , class LV, Type 1, flat of size 250 mm x 150 mm x 40 mm for cable protection, confirming to IS : 5820-1970 and having minimum average load breaking strength 200 Kg/Sqcm complete all as specified. Note: Testing of PCC cable cover shall be carried out by the contractor from any Govt approved lab all as directed by Engineer in charge and cost of testing shall be deemed included in the quoted rate.
M/L for PCC 1:4:8 type D-2 (using 40mm graded stone agg) in foundation, filling and mass concrete complete all as specified and directed.
M/L for hard core of gauge n.exc 0.63mm deposited, spreed and levelled in layers n.exc 15 cm thick watered and rammed to a true surfaces and brocken stones or baoulders
M&L brick work with sub class B brick straight or curved on plan exc. 6m mean radius using old size bricks built in Cement Mortar (1:6) complete all as specified and directed.
M&L for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth with using extra cement complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply only integral water proofing compound complete all as specified & as directed by Engineer-in-Charge. Make : Pidilite/Sika
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate for foundation of transformer and LT panel ,coping of pole etc above ground level.
S&F GI pipe medium grade 40 mm passing through cables, walls , across the roads with proper clamps, nut & bolts including taking down complete all as specefied and dirceted.
M&L for expanded metal cut to length bend to shape required with and annealed miled steel not less than 0.9 mm dia including fixed with galvanised steel stapples or welded with supporting steel members. Weight XPM is not less than 3.15 Kg/Sqm complete all as specified. Note:MS work required to fixed XPM mesh shall be measured and paid seperately.
M & L for Cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections incl nuts, bolts, washers, welding, bending cold or hot,, drilling holes for bolts in any shape or size as indicated or directed and inclusive or one primer coat, one under coat and one finishing coat of super enamel paint complete all as specified and directed.
Supply and fixing Tubes, 'light grade' galvanised, 40 mm dia with all fitting and fixed complete to walls and ceilings or laid in floors for passing through of cable making good the disturbed surface matching with existing all as specified and directed.
Supply and fixing of PVC sheathed copper cable 3 core 2.5 sqmm as used in service connection from junction box to upto street light fittings duly passing through PVC conduit all as specified and directed. Note: PVC conduit shall be measured and paid seperately.
Supply and fixing street light junction box of size 300 mm x 200 mm x 105 mm, made out of FRP sheet with weather proof hinged door including self locking arrangement, out door type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) with and including 6 Apms MCB single pole, single phase 230 volts, including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete and all as specified and directed.
Taking down old unserviceable XLPE UG cable of any size complete all as specified and directed. Note :- Old retrived material will be deposited to MES store yard
Supply laying and testing of cable XLPE insulated,screened PVC bedded,galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including suitable lugs for 95 sqmm X 3.5 Core size scomplete all as specified and directed.
Supply laying and testing of cable XLPE insulated,screened PVC bedded,galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including suitable lugs for 35 sqmm X 3.5 Core size scomplete all as specified and directed.
Supply laying and testing of cable XLPE insulated,screened PVC bedded,galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including suitable lugs for 25 sqmm X 4 Core size scomplete all as specified and directed.
Supply laying and testing of cable XLPE insulated,screened PVC bedded,galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor including suitable lugs for 10 sqmm X 2 Core sizes complete all as specified and directed.
Supply and Fixing of MCCB 3 Pole, 415 V, with Microprocessor release 250 Amps with breaking capacity 36 KA complete all as specified and directed.
S&F MCB, single pole 240 volts 6 to 32 Amp 'c' series capacity fixing in DB’s including proper thimble connections complete all as specefied and directed.
Supply and laying XLPE 1100 volts grade heavy duty with PVC insulated, armoured cable, 4 core 16 sqmm in service supply connection passing through trenches, walls, road crossings and poles complete all as specified and directed.
Supply and laying XLPE 1100 volts grade heavy duty with PVC insulated, armoured cable, 3.5 core 120 sqmm in service supply connection passing through trenches, walls, road crossings and poles complete all as specified and directed.
M&L for Sheet metal enclosures distribution board double door three phase 415 volts TPN 4 way series for MCCB as incoming and MCB(TP/SP) as outgoing,comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed. Notes :- (i)The DB shall be TPN series of make Legrand/C&S/Scheinder (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost. (iii)connection of the MCCBs/ISOLATORs/MCBs with cable shall be made through appropriate size pin /bottle type thimble properly crimped. (iv) all the vacant holes of the DB shall be provided with blanking plates of suitable size. Make:-Havells/Standard/Scheinder
Supply and fixing of MCCB 63 amp 4 pole, 415 volts 25 KA rupturing capacity including proper thimbles, fixing on DB'S Complte all as specefied and directed. Make:-Havells/Standard/Scheinder
Earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 25x4 mm as earthing lead covered with 20mm bore GI pipe light grade by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20 mm dia GI watering pipe 'medium grade', funnel with wire mesh, earthing chamber with cement concrete (1:3:6) type C-1, RCC chamber cover 80 mm thick (1:2:4) type B-1, excavating & earth work all as shown in electrical plate No. 3 of SSR (Part-I) and testing on completion complete all as specified and directed.
Earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected togalvanized earth lead wire 4.0 mm dia by means of bolts ,nuts ,check nuts and galvanized iron or steel incl excavation and earth work, GI pipe light grade 25mm/40 mm bore for protection of GI wire /strip from earth electrode to and incl supplying and lying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded crushed stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed
Earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected togalvanized earth strip 25X4 mm by means of bolts ,nuts ,check nuts and galvanized iron or steel incl excavation and earth work, GI pipe light grade 40 mm bore for protection of GI wire /strip from earth electrode to and incl supplying and lying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded crushed stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed
Swami Engineers
AP BUILDERS
UNITED ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .