| 1 | L1₹12.7 LAccepted-AOC | ₹12.7 L Quoted ₹14.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹14.3 L+₹26,973 (1.92%)Rejected-Finance | ₹14.3 L+₹26,973 (1.92%) | L2 | Rejected-Finance L2 |
| 3 | L3₹14.7 L+₹70,667 (5.03%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹14.7 L+₹70,667 (5.03%) | L3 | Rejected-Finance L3 |
| 4 | L4₹14.9 L+₹91,100 (6.49%)Rejected-Finance | ₹14.9 L+₹91,100 (6.49%) | L4 | Rejected-Finance L4 |
| 5 | L5₹15.8 L+₹1.8 L (12.9%)Rejected-Finance | ₹15.8 L+₹1.8 L (12.9%) | L5 | Rejected-Finance L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
24 Mar 2021, 6:00 pmClosed
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR /MANINTENACE OF INTERNAL ELECTRIFICATION WORK IN CERTAIN MD ACCN OF AT ZONE - II (A) AREA UNDER GE JAIPUR AT JAIPUR MIL STN
2021_MES_426377_1
GE/J-74/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JAIPUR
As per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹40,000
Yes
30 Mar 2021
27 Feb 2021
26 Mar 2021
27 Feb 2021
24 Mar 2021
12 Mar 2021
27 Feb 2021 - 11 Mar 2021
Amount
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets etc and making good disturbed surfaces even and smooth using CM 1:3 including white/colour wash to match the existing surface complete.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators as required for the following :- One light point controlled by one switch.
All as per Item no. 2 above but One fan point controlled by one switch.
All as per Item no. 2 above but One light point controlled by two, two way switches.
All as per Item no. 2 above but One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per Item no. 2 above but One socket outlet 6 amp controlled by one switch on indepdendent board.
All as per Item no. 2 above but One bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.0 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets as required for one 16 amp socket outlet point controlled by one switch on independent board.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x16 mm ISI marked ivory colour with all fittings / fixing accessories with surface placstic board and white plate with frame for mounting switches, sockets, fan regulators as required for the following :- One light point controlled by one switch.
All as per Item no. 09 above but One fan point controlled by one switch.
All as per Item no. 09 above but One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per Item no. 09 above but One socket outlet 6 amp controlled by one switch on indepdendent board.
All as per Item no. 09 above but One bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x16 mm ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets for one 16 amp socket outlet point controlled by one switch on independent board.
S&F angle holder, insulated polycabonate body with back plate complete.
S&F switch piano flush button single pole one way 6 amp complete.
S&F switch piano flush button single pole one way 16 amp complete.
S&F switch flush type, 6 amp, single pole, two way complete.
S&F bell push, flush type, 6 amp 240 volts complete.
S&F door bell, AC, 240 volts, single pole complete.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F ceiling rose 3 plates polycarbonate body complete.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:- For 2x4 sqmm + 1x4 sqmm earth wire including 20 mm dia conduit.
2x6 sqmm + 1x6 sqmm earth wire including 25 mm dia conduit.
M&L for brick work with sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 and plastering 10 mm thick in CM 1:4 and 2 coats of white / colour washing to match the existing surface complete.
S&F 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16 amp as required. Make - Legrand cat ref no 507811 & 408592 or equivalent as approved by GE
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- SPN, 240 volts, 4 ways. Make - Legrand cat ref no 507610 or equivalent as approved by GE
All as per Item no. 29 above but SPN, 240 volts, 8 ways. Make - Legrand cat ref no 507611 or equivalent as approved by GE
All as per Item no. 29 above but SPN, 240 volts, 12 ways. Make - Legrand cat ref no 507612 or equivalent as approved by GE
All as per Item no. 29 above but TPN, 415 volts, 4 ways. Make - Legrand cat ref no 507670 or equivalent as approved by GE
S&F MCCB four pole, 125 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required. Make - Legrand cat ref no 420016 or equivalent as approved by GE
S&F MCB distribution board, tripple pole and neutral, powder coated CRCA steel sheet suitable for MCCB incomer upto 160 amp, 4 way, 415 volts, degree of protection IP 43 - IK- 09 with reversible double door, recess mounted, having 250 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. Make- Legrand cat ref no 507745 or equivalent as approved by GE
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- Single pole 6 to 32 amp. Make - Legrand cat ref no 408587 to 408595 or equivalent as approved by GE
All as per Item no. 35 above but Double pole 10 to 32 amp. Make - Legrand cat ref no 408631 to 408636 or equivalent as approved by GE
All as per Item no. 35 above but Double pole, 40 to 63 amp. Make - Legrand cat ref no 408637 to 408639 or equivalent as approved by GE
All as per Item no. 35 above but Four pole 40 to 63 amp. Make - Legrand cat ref no 408700 to 408702 or equivalent as approved by GE Note for MCBs & MCB DBs:- MCCBs, MCBs & MCB DBs shall be of the same make.
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 50 mm & inner pipe dia 25 mm duly filled with highly conductive and anti corrosive compound tested from NABL certified Laboratory of required quantity laid by by digging a bore of 150 mm dia surrounded by soil friendly backfill compound including connection with galvanised earth wire 4 mm dia from earth electrode to the equipment to be earthed duly protected in 15 mm medium grade GI pipe upto 7.5 m, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40 mm thick cover with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 2.0 ohm complete.
Supplying and fixing in repairs LED batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt (including driver) having colour temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make - Philips cat ref no. ENDURALED BATTEN "BN 108C LED 20S PSU CDL WH" or Bajaj cat ref no. BLTRU 20W WH VIVA or equivalent in other specified make as approved.
Supplying and fixing in repairs LED batten 9 watt, 900 lumens operating voltage 160 to 360 volts, colour temperature 6500K including connection all as per Philips Astra Line 9-Watt LED Batten or equivalent as approved by GE
Supplying and fixing in repairs LED bulkhead fitting 9 watt IP 66 & IK 09 with polycarbonate body duly prewired connection with 0.75 sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable all as per Philips cat ref no. WT202W LED6S CW PSU S2 PC or equivalent as approved by GE
Supply and fixing in repairs LED batten compact commercial batten both side connection suitable for single T8 LED tube made of PVC housing and prewired connection with LED tube both side connection.
Supplying and fixing in repairs energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required. Make - Philips cat ref no. RC365B LED33- 6500 PSU OD WH or equivalent as approved by GE
S&F in repair modular switch one way 6 amp 1 module all as per Legrand Britzy cat ref no. 673401 or equivalent as approved by GE
S&F in repair modular switch one way 16 amp 2 module all as per Legrand Brizy cat ref no. 673411 or equivalent as approved by GE
S&F in repair modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Britzy cat ref no. 673455 or equivalent as approved by GE
S&F in repair modular socket 6 amp 2/3 pin combined 2 module all as per Legrand Britzy cat ref no. 673452 oor equivalent as approved by GE
S&F in repair modular hum free electronic step fan regulator, 100 watt 2 module all as per Legrand Britzy cat ref no. 673430 or equivalent as approved by GE
S & F in repair white cover plate 1 modular with frame for fixing modular switch and socket
S & F in repair white cover plate 2 modular with frame for fixing modular switch and socket
S & F in repair white cover plate 3 modular with frame for fixing modular switch and socket
S & F in repair white cover plate 4 modular with frame for fixing modular switch and socket
S & F in repair white cover plate 6 modular with frame for fixing modular switch and socket
S & F in repair white cover plate 8 modular with frame for fixing modular switch and socket
S & F in repair white cover plate 12 modular with frame for fixing modular switch and socket
S & F in repair white cover plate 16 modular with frame for fixing modular switch and socket
S & F in repair plastic surface boxe 1 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 2 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 3 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 4 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 6 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 8 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 12 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 16 moduler for fixing modular switch and socket
S&F in repair modular switch one way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675501 or equivalent as approved by GE
S&Fin repair modular switch one way 16 amp 1 module all as per Legrand Mylinc cat ref no. 675511 or equivalent as approved by GE
S&Fin repair modular switch two way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675502 or equivalent as approved by GE
S&F in repair modular bell push, 6 amp, 1 module all as per Legrand Mylinc cat ref no. 675504 or equivalent as approved by GE
S&F in repair modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent as approved by GE
S&F in repair modular socket 6 amp 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675550 or equivalent as approved by GE
S&F in repair modular hum free electronic step fan regulator, 100 watt 2 module all as per Legrand cat ref no. 675530 or equivalent as approved by GE
Supplying and fixing in repairs phenolic laminated white sheet cover 3.0 mm thick, cut into required size suitable for fixing on existing boards / terminal boxes for mounting switches, sockets, regulators as required.
Fixing / repairing loose and disconnected point wiring or diverting the route of point wiring upto a length not exceeding 2.0 metre including required cable of same size and carrier (PVC casing caping or conduit, domestic gang box etc) with fasteners etc and making good disturbed surfaces even and smooth using CM (1:3) as required.
Supplying and fixing in repairs switch type hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity including connecting up complete.
Taking down industrial plug and socket including one number single pole MCB any make, any capacity after disconnecting complete.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Taking down carefully submain wiring with PVC casing caping / PVC surface conduit and making good disturbed surfaces complete.
Renewal of street light fittings like tube light/CFL/T5 of any discription with greenline high efficiency LED street light luminaire 25 watt complete with drive, pressure die cast aluminium housing, UV stablized polycarbonates cover, in built power unit, IP 65 protection including mounting bracket made of 25 mm GI pipe, medium grade ISI marked not less then 1.2 m bend in shape with two number clamps, nuts, bolts, washeres as required. Make Philips cat ref No BRP022 LED 10 CW MR S 1 PSU GR or equivalent as approved by GE
Rewinding the motor of table / pedestal / cabin fan 400 mm of any type and make with super enameled copper wire of existing gauge of approved quality including opening of fan, overhauling, providing fresh clean lubricating oil / grease, split pins and minor repairs for satisfactory operation, re-assembling and testing for the original speed & consumption complete.
Rewinding the motor of ceiling fan 1200/1400 mm of any type and make with super enameled copper wire of existing gauge of approved quality including overhauling and minor repairs for satisfactory operation, testing for the original speed & consumption complete.
Rewinding the motor of fresh air/exhaust fan 230/300 mm of any type and make with super enameled copper wire of existing gauge of approved quality including opening of fan, overhauling, providing fresh clean lubricating oil / grease, split pins and minor repairs for satisfactory operation, re-assembling and testing for the original speed & consumption complete.
Rewinding the motor of exhaust fan 375/450 mm of any type and make with super enameled copper wire of existing gauge of approved quality including opening of fan, overhauling, providing fresh clean lubricating oil / grease, split pins and minor repairs for satisfactory operation, re-assembling and testing for the original speed & consumption complete.
Renewal of ball bearing of ceiling / exhaust fan of any size and make as required with alignment of shaft and testing complete. Make - SKF (6201 to 6203) or equivalent as approved by GE
Renewal of AC film capacitor 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete. Make - Havells cat ref no. 2.5 mfd / 440V / PLWW / 25x45 or equivalent as approved by GE
Renewal of AC film capacitor 4.0 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete. Make - Havells cat ref no. 4.0 mfd / 440V / PLWW / 28x52 or equivalent as approved by GE
Renewal of self lubricating bush of gun metal of same type for ceiling fan / exhaust fan as required.
Renewal of shaft of approved quality for ceiling fan / exhaust fan any make any type & size as required.
Opening up geyser of capacity 25/50 litre, checking defect, taking out u/s parts and re-assembling after carrying out repair / renewal work including nuts / bolts / wahers / gaskets / fusible plug etc wherever required and minor items not included separately in schedule. (Note - U/s parts shall be measured separately under relevant item of schedule as supply only).
Supply only heating element 2.0 KW, 230 volts, ISI marked suitable for 50 litre capacity geysers of any type as required.
Suppply only thermostat ISI marked suitable for 25/50 litres geysers as required.
Supply only heating element 1.50 KW, 230 volts, ISI marked suitable for 25 litre capacity geysers of any type and make as required.
Renewal of down rod of ceiling fan made of GI pipe medium grade 15 mm bore including cutting, threading, painting etc as required.
M&L for clamp and back plates fabricated from steel sections conforming to Gde Fe 410-O or Fe 310-O including nuts, bolts, washer, drilling holes for bolts in any shape or size for fixing ceiling fan complete.
S&F ventilating fan single phase, 230 volts, 250 mm sweep plastic body with mounting rings all as per Havells cat ref no. Ventil Air-DX or equivalent as approved by GE
S&F ventilating fan single phase, 230 volts, 300 mm sweep plastic body with mounting rings all as per Havells cat ref no. Ventil Air-DX or equivalent as approved by GE
Schedule of Credit
M/s Radhey Enterprises
J.P. Enterprises
M/S Sheeba Enterprises
M/S STEADFAST ENTERPRISES
M/S TRADE LINKERS
GLOBAL ENGINEERS AND INNOVATORS
TRISHUL ENTERPRISES
agrawal constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .