CWE NAGROTA
HQ CWE Nagrota PIN-181221 C/o 56 APO
REPAIR/REPLACEMENT OF TRANSFORMER, VOLTAGE STABLIZER WITH CONNECTING ITEMS AT 213 TC UNDER GE NAGROTA
2026_MES_786811_1
CWE/NGT-63/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NAGROTA
As per NIT
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹20,000
Yes
28 Aug 2026
28 Aug 2026
21 Sept 2026
28 Aug 2026
18 Sept 2026
11 Sept 2026
28 Aug 2026 - 2 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Filteration, heating and dehydration of transformer oil (at Site) on load system, EHV grade having di-electric strength not less than 55KV with 2.5 mm gap high viscosity in transformer of capacity 40 KVA to 500 KVA as per IS-335 of 1983. The reducing moisture, acidity carbon particle in transformer Oil.
Note: The filtration, heating and dehydration of transformer oil shall be carried out site. The unit rate quoted by the contractor shall deemed to include for arrangement of filtration machine and its transporation to various location of installation of transformer and top up of transformer oil. | 1,500 | Ltr | - | - |
| 2 | Supply, treating (dehydrating), filling new transformer oil in transformers for topping up levels or for replacement of unfit oil .New oil having dielectric strength not less than 60 KV at 2.5 mm Gap and shall be confirming to IS 335.
Note: The Empty Barrel is the property of department. Supply should be given in Sealed Containers. | 600 | Ltr | - | - |
| 3 | Inspection of defective step down 11 KV / 0.433 upto 315 KVA transformer any make, installed on plinth/floor/pole mounted, indoor/outdoor type, step opening, removing the top cover of transformer, detecting the fault, rectfying the defect at site except major fault of burnt winding or other. The following tasks if required will be performed :-
(a) Step opening of the transformer and removing the transformer top cover for checking/ rectified the faults of the transformer.
(b) Replacement of defective HT/LT bushes, spindles etc.
(c) Refixing the transformer top cover with nuts, bolts and washers.
(d) Testing of transformer Complete.
Note: (i) In case of replacement of LV / HV bushing / spindles / tap changer etc, will be measured and paid for separately under relevant items
(ii) Transformer oil (if required) for topping will measured and paid for separately under relevant item.
(iii) Replacement of gaskets to arrest the leakages is included in the item rate
(iv) The rate also including the painting of complete transformers with two coats of synthetic enamel paint of smoke grey colour | 4 | Each Job | - | - |
| 4 | Taking down transformer 11 KV/0.433 KV of any make of capacity 40 KVA to 160 KVA mounted on two/four pole structure or on platform / indoor floor mounted carefully from their position after removing electrical connection, earthing leads etc, for executing necessary comprehensive preventive maintenance as well repairs necessiated, including to and fro transporting to Workshop, and refixing & testing after execution of maint/repair to their original position or to other location as directed of capacity as under: -
Note :- (i) Necessary transportation where directed and crane for lifting/un loading on platform is also included in the item rate only.
(ii) The rate also including the painting of complete transformers with two coats of synthetic enamel paint of smoke grey colour | 2 | Each Job | - | - |
| 5 | All as per srl item No-4, here-in-before but capacity exceeding 200 KVA but not exc 315 KVA all as specified and directed. | 2 | Each Job | - | - |
| 6Dismantling core, taking out damaged coils (HV Coils) of following transformers from its position for replacement, including supplying and fixing new winded coils with super enamelled copper winding wires of reqd gauge, number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and directed. | |||||
| 6.01 | Transformer of capacity 40 KVA to 160 KVA | 160 | Kgs | - | - |
| 6.02 | Transformer of capacity 200 KVA to 315 KVA | 280 | Kgs | - | - |
| 7Reconditioning of LT side coils from its position for replacement including supplying and fixing new winded coils with cotton braided copper wire or strip of approprite size (thickness & breadth) number of turnings and weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed. | |||||
| 7.01 | Transformer of capacity 40 KVA to 160 KVA | 106 | Kgs | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
tender63.pdf
Tender Documents • 0.65 MB
BOQ_881742.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .