Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-Finance | ₹1.7 Cr | L1 | Accepted-Finance The bidder possess 1st lowest position |
| 2 | L2₹1.8 CrRejected-Finance | ₹1.8 Cr | L2 | Rejected-Finance The bidder possess 2nd lowest position |
| 3 | L3₹1.8 CrRejected-Finance KHATI SAHI PO CHILIKA NUAPADA DS KRUSHNA PRASAD GANJAM ODISHA PIN 752011 | PURI | ODISHA | 752011 | ₹1.8 Cr | L3 | Rejected-Finance The bidder possess 3rd lowest position |
| 4 | L4₹1.8 CrRejected-Finance AT ANLOI VILLAGE CHAUPUR P O MODARI P S DHANG DIST PURI PIN 752015 STATE ODISHA | PURI | PURI | ODISHA | 752015 | ₹1.8 Cr | L4 | Rejected-Finance The bidder possess 4th lowest position |
| 5 | L5₹1.8 CrRejected-Finance | ₹1.8 Cr | L5 | Rejected-Finance The bidder possess 5th lowest position |
Tender Value
₹2.2 Cr
EMD Value
₹2.2 L
Closing Date
15 Jan 2026, 5:00 pmClosed
CHIEFCONSTRUCTIONENGINEERCENTRALRANDBCIRCLEBBSR
OFFICE OF THE CHIEF CONSTRUCTION ENGINEER, CENTRAL RANDB CIRCLE,BHUBANESWAR
Construction of Kitchen-cum-Dining, Earth filling, Cycle Stand, approach road, drain and boundary wall of Odisha Adarsha Vidyalaya, Beraboi under Delanga Block in Puri District for the year 2025-26..
2026_EICCL_124175_2
TENDER CALL NOTICE NO.21 OF 2025-26
Open Tender
Civil Works - Buildings
180 days
Bhubaneswar
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹2.2 L
Yes
7 Jun 2026
3 Jan 2026
15 Jan 2026
3 Jan 2026
15 Jan 2026
3 Jan 2026
CIVIL WORK
Earth work in excavation in all kinds of soil within 50m, initial lead and 1.5m, initial lift including rought dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge
Kitchen
Boundary
Cycle
Drain
Approach road
Sand filling in foundation and plinth including cost of all material, labour, conveyance, loading and unloading, taxes, royalties, sundries, tools and plants etc. complete as per the driection of the Engineer in Charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights).
Kitchen
Boundary
Cycle
Drain
Approach road
Cement concrete of prop.(1:3:6) in foundation and floors using 4cm. size black hard (crusher broken) granite metal of approved quality from approved quarry including lowering, laying concrete, watering and curing etc. complete to required level laid in layers not exceeding 15cm. thick including cost, conveyance, royalties and taxes of all materials and cost of all labour, side shuttering, cost of dewatering if necessary etc. required for the work complete as directed by the Engineer in charge.
Kitchen
Boundary
Cycle
Drain
Fly ash.bricks masonry in C.M (1:6) in foundation and plinth using fly ash bricks of 25cmx12cmx8cm size having crushing strength not less than 75kg / cm2 after immersing the bricks for six hours in water before use in and for ornamental flower beds. Plinth molding and similar such type of works with all necessary projections cutting moulding corbelling champhering, watering and curing including cost, conveyance, royalties and taxes of all materials and cost of all labour, sundries and T&P etc required for the work complete as directed by the Engineer in charge.
Kitchen
Boundary
Cycle
Fly ash.bricks masonry in C.M (1:6) in Superstructure using fly ash bricks of 25cmx12cmx8cm size having crushing strength not less than 75kg / cm2 after immersing the bricks for six hours in water before use in and for ornamental flower beds. Plinth molding and similar such type of works with all necessary projections cutting moulding corbelling champhering, watering and curing including cost, conveyance, royalties and taxes of all materials and cost of all labour, sundries and T&P etc required for the work complete as directed by the Engineer in charge.
Kitchen
Boundary
Cycle
Providing lifting, hoisting and laying R.C.C. of M-20 Grade to base of columns and footing, columns, beams, plinth band, lintels, chajja, shaft, fins, roof slabs, balconies, stair cases, parapets, window sills, lofts, railing, jally, copping or in places as shown in the drawing for all floors with 20mm and down graded size black hard crusher broken ships of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth (if required providing plaster with cement mortar (1:4) wherever necessary without any extra cost) including rigid smooth centering and shuttering, scafolding, watering (excluding reinforcement bars) and curing for required period including cost of all material, labour, conveyance, royality, loading and unloading, sundries, tools and plants etc. complete as per the direction of the Engineer in Charge.
a)Base Footing
Kitchen
Boundary
Cycle
Drain
(b) Column in s/s
Kitchen
Boundary
Cycle
(c) Plinth beam
Kitchen
Boundary
Cycle
(d) Beam
Kitchen
Cycle
(e) Roof slab
Kitchen
Cycle
Drain
(f) Lintel
Kitchen
Boundary
(g) Chajja
Kitchen
(h) Shelves
Kitchen
(h) Drain wall
Drain
Supplying,Cutting,straightening of steel HYSD (Fe- 500) conforming to (IS- 1786) with bending, binding, cranking, hooking, welding or jointing if necessary & tying the grills and placing in position as required for the Rod work in all floors and & for providing fan hooks hosting lowering ,& laying steels including cost conveyance ,taxes & royalties of all materials and binding wires of 18 to 20 gauge & cost of all labour T&P required for the work etc. Complete in all respect as per the direction of Engineer in charges ( payment will be made on weight of MS rod or tor steel only basing on the co- efficient of MS rod or tor steel bars approved by SAIL/ TATA/ competent authority and (No separate payment will be made towards the cost of binding wires over lapping, wastage, coupling, welded, joints , spacer bars, ,chairs stays, hangers and annealed steel wires or other methods for binding and placing etc.)
Kitchen
Boundary
Cycle
Drain
25 mm Thick Grading Concrete in C.C.(1:2:2) using 6 mm H.G. chips. (Per Sq.M.)
Kitchen
Providing 6mm thick cement plaster (1:4) ( 1 cement : 4 sand) to R.C.C surface including close & deep chipping and cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing as shown in the drawing including cost of all materials , labour ,conveyance ,loading and unloading , taxes, cess, royalities ,scaffolding, watering ,curring, sundries ,tools and plans etc complete as per direction of E.I.C.
Kitchen
Boundary
Cycle
Providing 12 mm thick cement plaster (1:6) ( 1 cement : 6 sand) to outside plastered surface/ plumped surface of masonary ,racking out joints , cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing as shown in the drawing including cost of all materials , labour ,conveyance ,loading and unloading , taxes, cess, royalities ,scaffolding, watering ,curring, sundries ,tools and plans etc complete as per direction of E.I.C.
Kitchen
Boundary
16mm thick cement plaster in cement mortar (1:6) in all floors at all height finishing smooth to rough surface of brick walls after raking out the joints including watering and curing rounding of corners with cost conveyance, royalties and taxes of all materials and cost of all labour scaffolding sundries and T&P etc required for the work etc complete as directed by the Engineer in charge.
Kitchen
Boundary
Cycle
Wall painting 2 coats with weather coat cement paint of approved shade on outer wall surface over a coat of water bound wall cement primer to give an even shade including cost of brushes and putty including cost of paint scrapping, cleaning rubbing, scaffolding including all costs of labour etc. complete as per direction of E.I.C.
Kitchen
Boundary
Cycle
Approach road
Supplying, fitting and fixing GraniteSlab (0.1 to 0.40 Sqm ) in floors of approved make laid on 20mm thick C.M (1:4) & filling joints with white cement of approved quality including cost of all materials, takes labour T&P etc required for the work. per 1 sqm (Data for 10 sq.mt.)
Kitchen
Providing & applying Distempering over a coat of primer 2 coats of (1coat primer+2coats distemper ) with approved quality ,including cleaning and smoothening the sur face thoroughly including cost of all materials ,labour, conveyance , taxes, cess ,royalities ,scaffolding , watering , curing ,sundries,tools and plans etc. complete as per direction of E.I.C.
Kitchen
Cycle
Supplying fitting and fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA /NCL VEKA LTD.) Casement Door- 60-Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mm x2.5mm for outer frames , 102 mm x 60mm x 2.25 mm for casement window sash profile and 74 mm x 60 mm x 2.5 mm mullion profile capable of mounting single glazing system , structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like ciipping locking system made of aluminium 1 NO. per sashes and the system is to be installed at the site using anchor fasteners rubber sealant , easy glazing / deglazing at site etc. including cost and conveyance all materials , accessories , labour charges, materials and product conforming to D 638-14 , EN -477-95 and other applicable codes and standards.
Kitchen
Supplying fitting and fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA /NCL VEKA LTD.) Three Track -Three pannel sliding window - 60-Series duly manufactured using UPVC reinforced profiles of 108 mm x 45 mm x2.5mm for outer frames and window sash profile and 39 mm x 58 mm x 2.5 mm mullion profile capable of mounting single glazing system , structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window sash shall be fitted with 6 mm thick clear toughened glass of SAINT - GOBAIN make duly fixed with EPDM weathering seal resistant accessories like ciipping locking system made of aluminium 1 NO. per sashes and the system is to be installed at the site using anchor fasteners rubber sealant , easy glazing / deglazing at site etc. including cost and conveyance all materials , accessories , labour charges, materials and product conforming to D 638-14 , EN -477-95 and other applicable codes and standards.
Kitchen
Supplying windows with M.S.Grill made out of MS angle frame , MS flat, sheet of approved section & design electrically welded properly 2with all necessary locking arrangement including cost & conveyance of all materials, labours charges,carriage of materils to the site etc complete.
Kitchen
Boundary
Painting with two coats of enamel paint of approved quality and shade over surfaces as specified below ( steel surface) to give an even shade with 2 coats of approved quality over one coat of steel primer including costs of all materials, labour , conveyance ,taxes, cess , royalities , scaffolding ,watering ,tools and plan etc complete as per direction of E.I.C.
Kitchen
Boundary
Supplying, fitting and fixing vetrifed tile in floors of size 600mm x 600mm of approved make confirming to IS 13755 laid on 20 mm thick cement mortar (1:4) (1 cement:4 course sand) and filling joints with white cement of approved qualiy including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-Charge.es and T&P. etc. required for the work complete.
Kitchen
Supplying, fitting and fixing vetrifed tile in dados of size 600mm x 600mm of approved make confirming to IS 13755 laid on 20 mm thick cement mortar (1:3) (1 cement:3 course sand) and filling joints with white cement of approved qualiy including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-Charge.
Kitchen
Supplying & fixing of industrial vitrified tiles on 20 mm thick bed of cement mortar 1:4 jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing etc complete.
Kitchen
Filling F&P with excavated materials including all cost, conveyance,royalty & taxes etc.compete of all materials to work site as per specification approved by the department & direction of Engg-in-charge.
Boundary
Cycle
Filling foundation & plinth with excavated earth materials etc complete.
Cycle
2.5 cm thick A.S flooring with C C (1:2:4) including punning using 12mm c.bh.g chips & watering with cost of all charges etc complete.
Cycle
Providing weep holes in brick masonary / plain or reinforced concrete abutment with 100mm dia PVC pipe
Drain
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as g (AR, P-158/37)
Approach road
Construction of granular sub-base by providing Gr.-VI material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller.
Approach road
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.PCC Grade M15 Concrete.
Approach road
Providing of 80 mm thick factory made cement concrete interlocking paver block of M-35 grade and approved make,varity colour and size made by block making machine with strong vibratory compection of approved design and shape ,laid in required colour and pattern over 50mm thick compected bed of coarse sand ,filling the joints with fine sand etc,all T&P etc complete as per direction of Engineer- in-charge.
Approach road
Providing and filling sand with good river course sand and well-watered & rammed etc. complete as per the direction of Engineer-in-charge.(AR, P-08/15)
Earth filling
Excavation of foundation for structure in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting.
Earth filling
ELECTRICAL WORKS
Sub-Head I (modular Wiring Items)
Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Each lightpoint should have provision for ceiling rose and angle holder point. In all the rooms there shall be two types of switchboard- one for raw and the other one for inverter. The inverter switchboard shall include atleast one fan, one light and other emergency sockets. Each quarter shall have 2 separte Dbs- one for raw and the other one for inverter.
GROUP-A
GROUP-B
GROUP-C
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5)
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5)
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit (2X4+1X1.5)
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit . (2X6+1X2.5)
Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
Sub-Head II (Light fitting Fixture & Fan)
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.( REGULATOR COMPATIBLE)
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
SITC of Sleek LED 9 watt LED Lamp complete with all accessories etc. directly on angle holder as required AS PER DIRECTION OF eNGINEER-IN-CHARGE. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supply and fixing of 10 Watt LED BH Fitting (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
BDBS,DB,AC DB,FLOOR PANELS,MCBS
Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years
Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
Supply and fixing of 8 way(Inverter DB) DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years.
Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, DP MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 1 year.
Supplying and fixing 32Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
Supplying and fixing 32 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, DP MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 1 year.
(Earthing) INSTALLATION
S/IT/C Of Earthing withG.I earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge.
Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
CABLING AND END TERMINATION MAIN AREA
Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
3core x6 sq mm
LAYING OF CABLE
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
Supplying and making end termination with brass comprecision gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
3 core x6 sq mm
INTERNAL TOTAL
LIGHTENING PROTECTION SYSTEM
Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent
Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent
Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
EXTINGUISHER SYSTEM
Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories Make-Ceasefire/Safex/Fireshield
P.H. WORK
Internal PH works
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipes conforming to pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge (Supreme/Ashirvad/Oriplast). 20mm dia C-PVC pipe .
25mm dia CPVC ASTM Pipe
Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) .
Ground Floor 25m dia UPVC ASTM Pipe
32m dia UPVC ASTM Pipe
40mm UPVC ASTM Pipe
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.
Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in charge .
Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall .
Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.15mm dia Long body CP Bib cock ( Jaquar make)
15mm dia CP angle stop cock(FLR-CHR-5053N Jaquar make)
15mm dia CP Pillar cock (FLR-chr-5011N Jaquar make)
25mm dia brass or gun metal fullway valve(Leader / Kriti Make)
32mm dia brass or gun metal fullway valve(Leader / KritiMake)
40mm dia brass or gun metel fullway valve(Leader/KritiMake )
15mm dia CP flange
Sink cock(Jaquar Make)CON-CHR-349KN
Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge 2000 litre capacity water storage Sintex tank on the roof of ground floor.
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge 110mm dia U-PVC SWR pipes(Supreme/Ashirvad/Oriplast)
100mm dia U-PVC Plain Tee
100mm dia U-PVC Plain Bend
100mm dia U-PVC Door Bend
110mm dia Vent cowl.
75mm to 110mm dia pipe
75mm dia U-PVC Plain Bend
PVC Clamp suitable for 75mm to 110mm dia pipe
125mm dia CP grating
Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink With sink cock with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge 600x450x250 mm SS sink(With drain board -NIRALI)
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge. Under counter wash basin(560x450)(Jaquar -FLS -WHT -5701)
Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge Design mirror(Parryware)
Supplying all materials , labours ,T&P and providing fitting and fixing (Aqua Guard ) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage Capacity 120 Liters along with 3 nos of faucets 2for cold water and 1for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing ,spesification and direction of the Engineer incharge. (a) Aquaguard Pure Chill 120 PSS UV
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder AKP-ABR-35731P(Jaquar make)
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.
A. Kitchen Platform 1x3.0x1.2 B. Wash Basin Area 1x(3.250+0.6+0.6)x2.10 Wash basin Area 1x(2.450+0.98)x2.10 platform Support wall 2x0.6x0.75
Providing Granite slab for Wash Basin 1x3.25x0.60 1x2.10x0.60
Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in chargeKajaria / Somany of size 30 cm x 45 cm . Quantity same as plaster item above.
EXTERNAL P.H. WORK.
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm all round concrete.
Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge. Inside size 250mmx250mm
Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, Ground class fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class Fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge . Brick masonry soakway pit 1.40m dia x 2.00m deep
Please Enable Macros to View BoQ information
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.20 MB
BOQ_574391.xls
BOQ • 0.54 MB
DTCN4.pdf
Tender Documents • 1.54 MB
Download all tender documents and submit your bid