Tender Value
Refer Docs
EMD Value
₹13,000
Closing Date
7 Nov 2024, 4:00 pmClosed
Executive Engineer Electric Divsion-IV
Khanyar Srinagar Kashmir
reation of 100 KVA sub -station (dedicated sub- Station) along with HT/ LT networks for the office of poultry nutritionist Hariparbath Srinagar
2024_PDD_261781_1
NIT-34 of 2024-25
Open Tender
Electrical Works
Turn-key
20 days
Khanyar Srinagar Jammu and kashmir
As per SBD
6 documents required · 6 mandatory
₹500
Executive Engineer Electric Divsion-IV
₹13,000
Yes
2 Dec 2024
22 Oct 2024
9 Nov 2024
25 Oct 2024
7 Nov 2024
29 Oct 2024
28 Oct 2024 - 28 Oct 2024
Particulars
Supply installation testing and commisioning of 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al. wound upto 100kVA, , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. ( X-mer without OCTC (Off Ckt Tap Changer)
Providing ,Loading , unloading at site Installation Testing Commissioning of 9 Mtr. Long Pole, ST-410 SP33
Supply , fixing of Wedge Connectors / PG Clamps
Providing of Cement bottoming 1:2:4 mix as per Standards 0.5 cum per pole complete with material & labour
Supply , fixing of 11 kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply , fixing of 11 kV Horn Gap Fuse Set 3 Phase 200A ( set of 3 Nos )
Supply , fixing of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type. ( set of 3 Nos )
Supply , fixing of 240mm² single core Cable,1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type
Supply, Installation, Testing, Commissioning ,of LT Distribution BoxLT Distribution Box for 100 kVA DTR with 160 MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits.
Providing ,testing and commissioning of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing and fixing of Sundry items like aluminium lugs, Jumpers, binding Tape,
Supply , fixing of Galvinized Nuts and Bolts
Supply , fixing of Danger Plates with Clamps
Anti-Climbing Device ( of Barbed wire with clamps )
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm for poles
Providing of Painting of poles with 2 each coats of Red Oxide & aluminum Paint with 1 liter of Redoxide and aliminum paint each
Supply , fixing of GI Channel X-arm including clamps and braces ( fibricated out of 100X50X50X8 MM,75x40x40x 6 mm with top Bracket including clamp fibricated out of 50x 8 mm flat GI Strip
Supply , fixing, testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply,fixing ,testing & comissioning of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply , fixing, testing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing ,Loading , unloading at site Installation Testing Commissioning of 9 Mtr. Long Pole, ST-410 SP33
Supply,erection , Installation testing and commissioning of 35 mm² AB (HT) Cable (3x35+1x70 mm²) XLPE (11 kV, 3C + Earth)
Supply,erection , Installation testing and commissioning of 11 kV Heat Shrinkable Outdoor Cable Termination Kit ( 3 core, SET OF 3 nos) upto 35-95 sq mm
Supply , fixing of Galvinized Nuts and Bolts
Supply , fixing of Danger Plates with Clamps
Anti-Climbing Device ( of Barbed wire with clamps )
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm for poles
Providing of Painting of poles with 2 each coats of Red Oxide & aluminum Paint with 1 liter of Redoxide and aliminum paint each
Providing of Cement bottoming 1:2:4 mix as per Standards 0.5 cum per pole complete with material & labour
Providing ,Loading , unloading at site Installation Testing Commissioning of 8 Mtr. Long Pole, ST-410 SP15
Supply,erection , Installation testing and commissioning of 50 mm² ACSR Conductor ( Rabbit)
Supply,erection , Installation testing and commissioning GI Mucky / for Shackle Insulators ( 2.5 KG each)
Supply,erection , Installation testing and commissioning of 16 kN Polymer Shackle Insulators
Supply , fixing of Galvinized Nuts and Bolts
Supply , fixing of Danger Plates with Clamps
Anti-Climbing Device ( of Barbed wire with clamps )
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3 mm for poles
Providing of Painting of poles with 2 each coats of Red Oxide & aluminum Paint with 1 liter of Redoxide and aliminum paint each
Providing of Cement bottoming 1:2:4 mix as per Standards 0.45 cum per pole complete with material & labour
Max Marketing (BID ID -2216988)
Alamdar Electricals (BID ID -2216564)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .