Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAdmitted-Finance VPO BERLA TEHSIL AND DISTT CHARKHI DADRI HARYANA | CHARKI DADRI | HARYANA | 127022 | ₹20.7 L | L1 | Admitted-Finance |
| 2 | L2₹21.7 LAdmitted-Finance H NO 2338 NEW HOUSING BOARD COLONY SECTOR 12 HUDA PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹21.7 L | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical 00 VILLAGE GOTHRA 127022 | CHARKI DADRI | HARYANA | 127022 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical HARYANA HR | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | OM PARKASH CONT L1 | M/S SHAKUNTLAM ELECTORCARE L2 |
|---|---|---|---|---|---|
| 1.01 | Ground probe radar survey to check any underground obstruction before finalization the alignment. | 1 | Job | 25,000 ₹25,000 | 26,000 ₹26,000 |
| 1.02 | Providing and fixing caution sign boards, signals, watching fencing etc | 1 | Job | 10,000 ₹10,000 | 11,000 ₹11,000 |
| 1.03 | Boring/excavation to the precise dimensions for the launch of the specialization jack pushing machine/ any other method as desired by Railway Authorities in normal soil condition but not in rock / bolder / any underground utility like foundation, water supply line coming in alignment or other underground obstruction under railway line suitable For 600 mm i/d dia M.S pipe complete in all respect. | 31.7 | Per Metre | 18,000 ₹5.7 L | 19,000 ₹6.0 L |
| 1.04 | Cleaning of surface of M.S pipe (casing pipes) inner surface and outer surface by sand blasting at site to make the surface ready for P.U coating /high build epoxy paint/ polythene tap system complete in all respect. for 600mm MS pipe | 119.57 | Sqm | 600 ₹71,743.20 | 700 ₹83,700.40 |
| 1.05 | Coating of 600 i/d MS pipe outer and inner surface of casing and carrier pipe with 100 % elastomeric polyurethane coating to AWWA-C2A/C222-1999 specifications to 1000 V dry film thickness for protection again corrosion complete in all respect. | 119.57 | Sqm | 1,700 ₹2.0 L | 1,800 ₹2.2 L |
| 1.06 | Providing and insertion of M.S casing pipe fabricated as per IS:3589 steel plates confirming to IS-2062 of following sizes |including cutting. beveling grinding and radio graphically complete in all respect including cartage to site of work and testing make Jindal, Electro steel, TATA and other approved reputed make as per railway specification 600mm MS casing pipe 8mm thickness | 31.7 | Metre | 30,000 ₹9.5 L | 31,000 ₹9.8 L |
| 1.07 | Providing and fixing HDPE spacer at a distance of 1 mtr apart to avoid contact of casing pipe complete in all respect for 350 mm DI carrier pipes. | 32 | Nos. | 2,500 ₹80,000 | 2,600 ₹83,200 |
Tender Value
₹13.3 L
EMD Value
₹26,700
Closing Date
21 May 2026, 1:00 pmClosed
PARMOD
M/Garh W.S.Divn. Ch-Dadri
Crossing the railway line by adopting trenchless method in village Pathrwa for the work Water conservation scheme by Construction of water bodies in village Pathrawa, Jawaharnagar and Nangla and connecting to Jarwa Disty. at 8.830 L of Jarwa Disty
2026_HRY_521538_1
2026D65C1867 50D5 4337 80D2 3A6598633191140IRR
Open Tender
Civil Works
90 days
Charkhi Dadri
2 documents required · 2 mandatory
₹1,000
₹26,700
Yes
1 Jun 2026
14 May 2026
21 May 2026
14 May 2026
21 May 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1.01 | Ground probe radar survey to check any underground obstruction before finalization the alignment. | 1 | Job | - | - | BI01010001010000000000000515BI0100001113 |
| 1.02 | Providing and fixing caution sign boards, signals, watching fencing etc | 1 | Job | - | - | BI01010001010000000000000515BI0100001114 |
| 1.03 | Boring/excavation to the precise dimensions for the launch of the specialization jack pushing machine/ any other method as desired by Railway Authorities in normal soil condition but not in rock / bolder / any underground utility like foundation, water supply line coming in alignment or other underground obstruction under railway line suitable For 600 mm i/d dia M.S pipe complete in all respect. | 31.7 | Per Metre | - | - | BI01010001010000000000000515BI0100001115 |
| 1.04 | Cleaning of surface of M.S pipe (casing pipes) inner surface and outer surface by sand blasting at site to make the surface ready for P.U coating /high build epoxy paint/ polythene tap system complete in all respect. for 600mm MS pipe | 119.57 | Sqm | - | - | BI01010001010000000000000515BI0100001116 |
| 1.05 | Coating of 600 i/d MS pipe outer and inner surface of casing and carrier pipe with 100 % elastomeric polyurethane coating to AWWA-C2A/C222-1999 specifications to 1000 V dry film thickness for protection again corrosion complete in all respect. | 119.57 | Sqm | - | - | BI01010001010000000000000515BI0100001117 |
| 1.06 | Providing and insertion of M.S casing pipe fabricated as per IS:3589 steel plates confirming to IS-2062 of following sizes |including cutting. beveling grinding and radio graphically complete in all respect including cartage to site of work and testing make Jindal, Electro steel, TATA and other approved reputed make as per railway specification 600mm MS casing pipe 8mm thickness | 31.7 | Metre | - | - | BI01010001010000000000000515BI0100001118 |
| 1.07 | Providing and fixing HDPE spacer at a distance of 1 mtr apart to avoid contact of casing pipe complete in all respect for 350 mm DI carrier pipes. | 32 | Nos. | - | - | BI01010001010000000000000515BI0100001119 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_600447.xls
BOQ • 0.26 MB
OT0162191.pdf
Other Document • 1.61 MB
Download all tender documents and submit your bid