Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC 91 B LAXMI NAGAR AIRPORT ROAD INDORE INDORE MADHYA PRADESH 452005 UDYAM MP 23 0000211 | INDORE | MADHYA PRADESH | 452005 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.0 L+₹24,958 (4.37%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹6.4 L+₹67,823 (11.9%)Rejected-Finance SUBAN BAZAAR DIGLIPUR NORTH ANDAMAN 744202 | DIGLIPUR | NORTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹6.8 L+₹1.1 L (19.5%)Rejected-Finance | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹7.0 L+₹1.3 L (23.5%)Rejected-Finance NO 353 DIGLIPUR 1 DIGLIPUR NORTH MIDDLE ANDAMAN 744 202 | NORTH AND MIDDLE ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | L5 | Rejected-Finance Not L1 |
Tender Value
₹5.7 L
EMD Value
₹11,400
Closing Date
19 Jul 2022, 6:00 pmClosed
GARRISON ENGINEER SOUTH DIGLIPUR
Garrison Engineer (South) Military Engineer Services, RK Gram, Diglipur North Andaman - 744 202
PROVISION OF ELECTRIC SUPPLY FOR RADAR STATION AT RANGAT AND PROVISION OF CEILING FAN IN PORTA CABIN AT KUTAR COMPLEX AT DIGLIPUR
2022_MES_529912_1
8872/E8
Open Tender
Civil Works
Item Rate
180 days
Diglipur
ALL BIDDERS ENLISTED WITH MES IN CLASS E AND CAT ai AND UNENLISTED BIDDERS MEET MES
ENLISTMENT CRETERIA OF CLASS E AND CAT ai REFER NIT
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER SOUTH DIGLIPUR
₹11,400
Yes
13 Sept 2022
10 Jun 2022
20 Jul 2022
10 Jun 2022
19 Jul 2022
24 Jun 2022
11 Jun 2022 - 15 Jun 2022
Amount
Excavating over areas, not exceeding 1.5 m deep and getting out in any type of soil.
M&L for PCC Type C2, 1:3:6 (using 40mm graded granite stone aggregate) as in foundations, filling and mass concrete.
M&L Pre-cast cement concrete Type C1, 1:3:6 (using 20mm graded crushed granite stone aggregate), block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4 complete.
M&L PCC Type B1, 1:2:4 (using 20 mm graded granite stone aggregate) as in copings, cills, benching of manholes, kneelers, apex stones, bed plates, levelling course, kerbs water troughs and the like including use of formwork, weathering, slightly rounded or chamfered angles and throating.
M&L for rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or concrete surfaces, finishing the surface even and smooth without using extra cement complete all as specified.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete.
M&L for broken stone hardcore of guage exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled/ rammed to a true surface.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose soil.
Removing excavated soil material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L 150 mm thick PCC Type B1, 1:2:4 (using 20 mm graded crushed granite stone aggregate) laid in flooring and pavings, etc. finishing surfaces of concrete even and fair (without using extra cement) complete all as specified.
Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out in hard/ dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface.
S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-410 Gde E-250.
S&F mild steel bolts, purpose made, with hexagonal or square head one end and screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 30 cm long and 12 mm dia of neck.
M&L mild steel bar 10 mm dia and cut to length, bend to shape fixing in flat angles with bolt.
M&L for preparation of new or previously untreated steel surfaces of any description, not exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of anti-corrosive paint over a coat of red oxide zinc chrome primer complete all as specified.
S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining, fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured).
S&F 1 mm thick PVC coated chain link fencing wire mesh of size 75 mm x 75 mm, made of 4 mm dia MS galvanised wire, straining and fixing to any type of standards, rails, straining bolts, etc including provision of GI wire binding complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/ loose soil or hard/ dense soil.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm
Supply and spreading clean, fine, dry river sand in trenches for cushioning of underground cable/ inside transformer yard complete all as specified and directed. Note: Only punned thickness shall be measured for payment purpose.
Supply, lay and testing XLPE insulated, cores laid up, PVC innersheathed, armoured with galvanised steel strip, heavy duty LT UG electric cable with stranded aluminium conductor, 1100 Volts grade, extruded PVC Type ST2 sheathed, conforming to IS: 7098 (Part I) 1988 of cross- sectional area 3.50 core 120 Sqmm.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (each pit not less than 2.25 mtr below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, including provision of galvanised earth strip 32x6 mm connected by means of bolts, nuts, check nuts and washers of galvanised iron steel, provision of 40mm dia GI pipes medium grade for earth strip protection connected from earth plate electrode to main switch board, provision of 15 mm dia GI pipe perforated medium grade for watering arrangement and PCC 1:3:6 type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 for earth pit. Cover with 6 No's 8 mm dia high strength deformed steel TMT bars on both ways, including test terminal block made of gun metal or phosphorous bronze 75x75x25 mm and drilled and screwed including 3 nos 8 mm dia, 25 mm long at hex head screw also necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance not exceeding 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No. 3 of schedule Part-I 2009 all as specified, directed and testing on completion.
M&L for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No. in and including PVC casing and capping with all fittings such as internal bend, end caps etc fixed on the surface of wall, ceiling, roof, steel structure etc. by means of suitable fixing accessories, with GI pressed steel / PVC box suitable for modular switches sunken boxes (with earth dolly) covered with logic modular PVC sheet cover for fixing of switches, sockets etc including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- NOTE: - Switch and socket to be measured and paid for separately. (a) One light point controlled by one 5/ 6 Amps one way switch.
S&F modular switch flush type single pole, one way 5/ 6 Amp complete.
S&F 40 mm bore dia GI pipe, medium grade with all fittings for hanging ceiling fan complete.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
S&F sheet metal enclosure for 8 way Distribution Board (DB), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates complete all as specified and as directed.
S&F MCB, single pole, 5 to 32 Amps, 240 volts, 'C' curve, 10 KA complete all as specified and as directed.
S&F MCB, single pole and neutral, 32 Amps, 240 volts, 'C' curve, 10 KA complete all as specified and as directed.
M&L for sub main wiring with 3 run of 4.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC casing and capping complete all as specified and as directed. Note : (i) Three run of submain wiring cable along with PVC casing and capping shall be measured as one unit length.
RMS Construction
MOHAMMED SAFIQUE
DAS AND SONS CONSTRUCTION
M/s Mohammed Shamim
M/S SHAJAHAN BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .