| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 BIDDER | |
| 2 | L2₹12.9 L+₹61,705 (5.03%)Rejected-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L2 | Rejected-AOC DUE TO NOT L1 BIDDER | |
| 3 | L3₹13.1 L+₹87,220 (7.11%)Rejected-AOC | L3 | Rejected-AOC DUE TO NOT L1 BIDDER | |
| 4 | L4₹16.2 L+₹4.0 L (32.2%)Rejected-AOC | L4 | Rejected-AOC DUE TO NOT L1 BIDDER |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
15 Feb 2020, 6:00 pmClosed
GE ARMY BARMER
GE ARMY BARMER POST BOX NO 53 JALIPA MIL STN BARMER 344001
REWIRING AND REPLACEMENT OF INTERNAL WIRING OF CERTAIN BLDGS ELECTRICAL FITTINGS AND FIXTURES CEILING EXHAUST FAN INCLUDING EARTHING AND LIGHTENING PROTECTION OF ZONE B AT JALIPA UNDER GE ARMY BARMER
2020_MES_315997_1
GE(A)/BMR-52 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE ARMY BARMER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹24,000
Yes
5 Jun 2020
18 Jan 2020
18 Feb 2020
18 Jan 2020
15 Feb 2020
1 Feb 2020
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and as directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and as directed.
Taking down unserviceable sub main wiring with copper/aluminium conductor,PVC insulated,unsheathed cable of any size drawn through and including rigid PVC conduit or steel conduit or PVC casing & caping including cutting chases for conduit or steel conduit and making good disturbed surfaces complete all as specified and as directed.
All as per Sl item No.03 above but with out taking down steel conduit or PVC conduit or PCC casing & caping.
M&L Point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor, nominal cross-sectional area is 1.5 sq mm , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including drawn through and including in PVC rigid conduit with all accessories complete concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/prestressed steel sunken/concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light/fan/ bell point controlled by one, one way switch complete all as specified and directed . Note :- surface conduit shall be laid in ceiling portion only.
All as per serial item No 5.00 above but for One light point controlled by 2 way switch.
All as per serial item No 5.00 above but for 5 Amps socket on same board with other switches.
All as per serial item No 5.00 above but for 5 Amps socket on independent board.
All as per Item No. 5.00 above but for 15 Amps 5/6 pin socket point on independent board with 4 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire,complete all as specified and as directed.
M&L Point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor, nominal cross-sectional area is 1.5 sq mm , single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including in PVC casing & caping with all fittings and accessories , complete fixed on wall/roof/floor etc, with1.6mm thick mild steel/prestressed steel sunken/concealed box (with earth dolly) duly painted two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch One light/fan/ bell point controlled by one, one way switch complete all as specified and directed .
All as per serial item No 10.00 above but for 5 Amps socket on same board with other switches.
All as per serial item No 10.00 above but for 5 Amps socket point on independent board.
All as per serial Item No. 10.00 above but for 15 Amps 5/6 pin socket point on independent board with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire complete all as specified and as directed.
All as per Serial Item No.10 above but wiring in existing conduit / casing & caping for one way switch One light/ fan/bell point controlled by one, one way switch 5Amps complete all as specified and directed .
All as per Serial Item No.10 above but wiring in existing conduit / casing & caping for one 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and as directed.
All as per Serial Item No.10 above but wiring in existing conduit / casing & caping for one 3 pin socket outlet 5 Amps on independent board complete all as specified and as directed.
All as per serial Item No.10 above but wiring in existing conduit / casing & caping for 15 Amps 5/6 pin socket point on independent board with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4.00 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire
M&L Point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including heavy duty drawn through and including in 20mm dia PVC rigid conduit with all accessories complete concealed in wall/roof/floor etc, ISI marked with modular metal flush box of suitable size for mounting of modular switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for,one way switch one light / fan point controlled by one, one way switch complete all as specified and directed .
All as per serial item No 18.00 above but for 5 Amps socket on independent board.
All as per serial item No 18.00 above but for 5 Amps socket on same board with other switches.
All as per serial item No 18.00 above but for one bell / buzzer point controlled by bell push
All as per serial item No 18.00 above but for One light point controlled by 2 way switch.
All as per Item No. 18.00 above but for 15 Amps socket point on independent board with 4 Sqmm PVC insulated FRLS multi-stranded copper conductor with 4 Sqmm PVC insulated FRLS multi-stranded copper conductor as earth wire,complete all as specified and as directed.
S&F ceiling rose, 3 phase / PVC / Polycarbonate, isolated bodycomplete all as specified and as directed.
S&F modular switch single pole 1way, 6 Amps 1 module complete all as specified and directed.
S&F modular switch single pole 1way, 16 Amps 1 module complete all as specified and directed.
S&F modular switch single pole 2way, 6 Amps 1 module complete all as specified and directed.
S&F modular bell push, single pole 1way, 6 Amps 1 module complete all as specified and directed.
S&F modular socket, 6 amps 2/3 pins combined 2 module complete all as specified and directed.
S&F modular socket, 6 amps 2/3 pins combined 2 module complete all as specified and directed.
S&F modular fan step regulator 120W 2 module complete all as specified and directed.
S&F modular white cover plate with frame suitable for 1 Module complete all as specified and as directed.
S&F modular white cover plate with frame suitable for 3 Module complete all as specified and as directed.
S&F modular white cover plate with frame suitable for 6 Module complete all as specified and as directed.
S&F modular white cover plate with frame suitable for 8 Module complete all as specified and as directed.
S&F switch piano 5 Amp flush type single pole one way with ISI marked,complete all as specified and as directed.
S&F switch piano 5 Amp flush type two way with ISI marked,complete all as specified and as directed.
S&F socket outlets 5 Amps 2-in-1, 3 pin 230 V AC flush type, complete all as specified and as directed.
S&F bell push, flush type, 5 Amps, 230 Volts complete all as specified and as directed.
S&F Bell ding dong AC 230 volt single pole complete all as specified and as directed.
M&L for submain wiring with two runs of 6 sqmm with one run of 6 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through and including PVC casing & caping fixed on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly complete all as specified and directed. Note :- Three runs of 6 sqmm and one run of PVC casing & caping shall be measured as one length for the purpose of measurement.
M&L for submain wiring with two runs of 4 sqmm with one run of 4 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through and including PVC casing & caping fixed on wall / ceiling with PVC saddles and cadmium plated steel screws and connected to common earth dolly complete all as specified and directed. Note :- Three runs of 4 sqmm and one run of PVC casing & caping shall be measured as one length for the purpose of measurement.
M&L for submain wiring with two runs of 6 sqmm with one run of 6 Sqmm earth wire of 1100V grade FRLS PVC insulated multi-stranded copper conductor, single core cable conforming to IS 694 drawn through existing steel conduit and connected to common earth dolly complete all as specified and directed. Note :- Three runs of 6 sqmm shall be measured as one length for the purpose of measurement.
S&F LED light fitting 1X10W bulk head luminaries, with lamp holders including 10 W LED bulb including taking down old fitting complete all as specified and as directed Make : Havells/ Bajaj/Philips/CG
S&F LED light fitting 20W with batten ( integrated driver), 6500K colour temp, decorative type with all accessories internally pre wired with tube rod and connectiong up with twin core twisted flexible copper conductor cable with suitable size including taking down old fitting complete all as specified and as directed Make : CG Cat Part No. DMLN1LT8-16 or techno commercially equivalent model of make Bajaj /Philips / Havells
S&F LED tube rod ( integrated driver), 6000K colour temp, 4 feet long of 20 watt (PC) in existing tube light fitting including taking down old tube rod complete all as specified and as directed Make : CG Cat Part No.LT5RT-18-CDL or techno commercially equivalent model of make Bajaj /Philips / Havells
S&F LED light fitting 10W with batten (integrated electric driver) 6600K colour temp decorative type with all accessories internally pre wired with tube rod and connectiong up with twin core twisted flexible copper conductor cable with suitable size including taking down old fitting complete all as specified and as directed Make : Wipro Cat Part No. D562065 or techno commercially equivalent model of make Bajaj /Havells / CG
S&F in replacement of Recess mounted 34W LED panel light (2' x 2') cool white , white powder coated CRCA sheet steel housing with high power LED's mounted, seamless front frame with flat white high transmission acrylic cover with all accessories suitable for armstrong/grid ceiling and prewired including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make :- Bajaj model No. BZRSLL GX34W or techno commercially equivalent make in CG / Havells / Philips .
Supply,fix, connecting and testing of energy efficient, pressure die cast aluminium housing with heat resistant toughened glass with frame & IP-66 protection and impact resistance IK 07, LED street light luminaries 45 watt, fixed on pole or wall with GI tubing 25mm bore 1.20m long bent shape as required and 02 Nos brackets made with MS clamp 25x3 mm flat and connectiong up with twin core twisted flexible copper conductor cable with suitable size taking down old fitting complete all as specified and as directed Make : Havells Cat Part No LHETAXU7PN6J045 or techno commercially equivalent model of make Bajaj /Havells / CG /Wipro
Supply, Fix ,connecting and testing of LED flood light 100W with innovative thermal management and in multiple optics and equipped with IP66 protection, ideal for stadium lighting and Highmast applications fixed on pole including taking down unserviceable light fitting complete all as specified and as directed. Make : CG Cat Part No. LFLN-100-CDL/60 or Techno commercially equivalent model of make Havells/Philips/Bajaj
Supply, Fix ,connecting and testing of LED flood light 50W with innovative thermal management and in multiple optics and equipped with IP66 protection, ideal for stadium lighting and Highmast applications fixed on pole including taking down unserviceable light fitting complete all as specified and as directed. Make : CG Cat Part No.LFLE-50-CDL or Techno commercially equivalent model of make Havells/Philips/Bajaj
Supply, Fix ,connecting and testing of 1X12W down light wave slim panel light luminaries with all accessories including 12W LED bulb including taking down unserviceable light fitting complete all as specified and as directed. Make : Wipro Cat Part No.D811265 or Techno commercially equivalent model of make Havells/Philips/Bajaj
Supply, Fix ,connecting and testing of 1X15W down light wave slim panel light luminaries with all accessories including 15W LED bulb including taking down unserviceable light fitting complete all as specified and as directed. Make : Wipro Cat Part No.D711560 or Techno commercially equivalent model of make Havells/Philips/Bajaj
Supply, Fix ,connecting and testing of 1X6W down light wave slim panel light luminaries with all accessories including 6W LED bulb including taking down unserviceable light fitting complete all as specified and as directed. Make : Wipro Cat Part No.D710660 or Techno commercially equivalent model of make Havells/Philips/Bajaj
Supply, Fix ,connecting and testing of 1X10W down light wave slim panel light luminaries with all accessories including 10W LED bulb including taking down unserviceable light fitting complete all as specified and as directed. Make : Wipro Cat Part No.D711060 or Techno commercially equivalent model of make Havells/Philips/Bajaj
S&F ceiling rose, surface bakelite, 65 x 50 mm, three terminals, 230 Volts complete all as specified and as directed.
S&F PVC board of size 30cmX25cmX 5cm depth including taking down old board complete all as specified and as directed.
S&F PVC board of size 25cmX20cmX 5cm depth including taking down old board complete all as specified and as directed.
S&F PVC board of size 20cmX15cmX 5cm depth including taking down old board complete all as specified and as directed.
M&L factory made distribution board in sheet metal enclosure in single door with out bus bar,SPN 2 way, 240V for fixing MCB's complete all as specified and as directed.
S&F factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 4 way, 240V for fixing MCB's complete all as specified and as directed.
S&F factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar,SPN 8 way, 240V for fixing MCB's complete all as specified and as directed.
S&F factory made distribution board in sheet metal enclosure in double door with 200A rated bus bar,TPN 4 way, 415V for fixing MCB's complete all as specified and as directed.
S&F factory made power line vertical type DB in double door, detachable gland plates for flush / surface mounting with bus bar neutral link and earth bar without MCB's suitable for TP/FP MCCB's as incomer comprising of MCCB TP 100 Amps 25KA-01No as incoming and suitable space for outgoing MCB's complete all as specified and as directed.
M&L MCB SPN ‘C’ Curve 10KA, 5 to 32 amps complete all as specified and directed .
M&L MCB SPN ‘C’ Curve 10KA, 40 amps complete all as specified and directed .
M&L MCB SPN ‘C’ Curve 10KA, 63 amps complete all as specified and directed .
M&L MCB SP ‘C’ Curve 10KA, 5 to 32 amps complete all as specified and directed .
M&L MCB TPN ‘C’ Curve 10KA, 63 amps, 415V complete all as specified and directed .
M&L Blankig plate for filling gap of MCB complete all as specified and directed.
M&L for PVC hylum sheet 3mm thick top cover of size 30cmX25cm including taking down old one complete all as specified and directed.
M&L for PVC hylum sheet 3mm thick top cover of size 25cmX20cm including taking down old one complete all as specified and directed.
M&L for PVC hylum sheet 3mm thick top cover of size 20cmX15cm including taking down old one complete all as specified and directed.
S&F in replacement of switch piano, flush button, single pole, one way, 5/6 Amps, 230 Volts complete all as specified and as directed.
S&F in replacement of ceiling rose, surface bakelite, 65 x 50 mm, three terminals, 230 Volts complete all as specified and as directed.
S&F in replacement of lamp Holder, insulated body with back plate , 230 Volts for batten fitting complete all as specified and as directed.
S&F in replacement of bell push, flush type, 5 Amps, 230 volts complete all as specified and as directed.
S&F in replacement of bell, ding dong / multi music type, AC, 230 volts, single pole complete all as specified and as directed.
S&F in replacement of socket outlet 5 Amps 2-in-1,3/5 pin 230V AC flush type complete all as specified and directed.
S&F in replacement of switch socket outlet 5 Amps 2-in-1,3/5 pin 230V AC flush type complete all as specified and directed.
S&F in replacement of switch socket outlet, multipurpose, 2 in 1, 5 and 15 Amps, flush type, universal ,230 Volts controlled by one switch complete all as specified and as directed.
S&F in replacement of Electronic fan regulator, stepped type, 100 W, AC, 230 Volts, fixed on existing laminated sheet complete all as specified and as directed.
S&F in replacement of Electronic mini fan regulator, stepped type, 100 W, AC, 230 Volts, fixed on existing laminated sheet including taking down old regulator complete all as directed.
S&F LED light fitting 1X10W bulk head luminaries, with frosted glass cover with all accessories including 10 W LED bulb and taking down old fitting complete all as specified and as directed Make : Havells Cat Part No.LHEXCGP7PN5W010 or techno commercially equivalent model of make Bajaj/Philips/CG
S&F in replacement of MCB SP ‘C’ Curve 10KA, 5 to 32 amps complete all as specified and directed .
S&F in replacement of MCB SPN ‘C’ Curve 10KA, 5 to 32 amps complete all as specified and directed .
S&F in replacement of MCB TPN ‘C’ Curve 10KA, 63 amps, 415V complete all as specified and directed .
Taking down ceiling fan / wall mounting fan ,any size and sweep from its position and transport to workshop for servicing,dismantling for servicing including removal of bearing,bushes,condenser, connector, flaxible cord,split pin etc if required removing old grease and refill fresh, lubricating bushes along with new washers, cleaning and washing fan blades, fan body etc with soap solution after repairing, re- assamble the same and transporting from workshop to any location in Jalipa and fixing to position / location as directed, connecting to electric system, testing etc complete all as specified and as directed . Note : -(i) Replacement of parts/rewinding shall be measured and paid separately (ii) Quoted rate is deemed to be inclusive of transporting fan from any location in Army Area to MES store & taking down unserviceable/ defective parts. (iii) Item such as bearings, gun metal bushes, capacitor, shaft etc required for replacement shall be measured and paid seperately as supply only.
Taking down and transporting of exhaust fan 9" (230mm)/12" (300mm) / 15" (375mm)/ 18" (450mm) sweep from any location inside Jalipa Mil Stn to MES E/M Store Yard / Workshop for stripping of fan washing thoroughly of bearing / bush by petrol, washing / cleaning fan blade body etc thoroughly provision of new greasing replacement of worn-out / defective unserviceable parts (wherever necessary) assembling the same after defective / unserviceable parts is replaced including provision of twisted twin core flexible wire upto 0.7 mts long size 23/0.0076 (ISI marked) and re-fixing the same at the same location including making good disturbed surface including testing etc complete all as specified and as directed . Note : -(i) Replacement of parts/rewinding shall be measured and paid separately (ii) Quoted rate is deemed to be inclusive of transporting fan from any location in Army Area to MES store & taking down unserviceable/ defective parts. (iii) Item such as bearings, bushes, capacitor, shaft etc required for replacement shall be measured and paid seperately as supply only.
M & L spray painting of ceiling fan, fan blades, down rod, canopy etc with a coat of synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the fan numbers etc with black paint complete all as directed by Engineer-in-charge.
Supply only fan blades (set of three) of any make / type of exhaust fan complete all as specified and as directed.
Supply only fan blades (set of three) of any make / type of ceiling fan of size 1200/1400mm sweep complete all as specified and as directed.
Supply only U clamp complete with nut bolt washer, split pin and rubber weal etc complete all as specified and as directed.
M&L cutting and taking out old burnout winding of any sweep ceiling fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed.
M&L cutting and taking out old burnout winding of 230 mm sweep exhaust fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed.
M&L cutting and taking out old burnout winding of 300 mm sweep exhaust fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed.
M&L cutting and taking out old burnout winding of 380 mm sweep exhaust fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed.
M&L cutting and taking out old burnout winding of 450 mm sweep exhaust fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and as directed.
Supply only ball bearing suitable for ceiling fan / exhaust fan / wall mountaining fan of any sweep complete all as specified and as directed.
Supply only gun metal bush suitable for ceiling fan / exhaust fan / wall mountaining fan of any sweep complete all as specified and as directed.
Supply only condensor 2.5 MFD suitable for ceiling fan of any sweep complete all as specified and as directed.
Supply only metalic bottom plate of ceiling fan of any sweep complete all as specified and as directed.
M&L for painting with two coats of spray painting to exhaust fan any type and size with Ist quality synthetic enamel paint, colour as approved after removing existing paint by scrubbing, dusting etc and finally writing the fan numbers etc in paint (Colour as approved ) complete all as specified and as directed.
S&F in replacement sheet metal enclosures comprising 2 pin earth plug socket, MCB SP 20 Amps (C-curve-10 KA) complete all as specified and as directed.
Taking down existing earthing and M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed by Engineer-in-charge. NOTE :(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-( ii) Item includes the cost of GI pipe up to 7.5m for protection of earth wire. Any variation in length beyond 7.50 m shall be measured separately.(iii) Item includes cost of lead wire up to 7.5 m Any variation in length beyond 7.50 m shall be measured separately.(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
S&F in replacement of aluminium strip 25mm x 3.15 mm with saddles and fixing screws etc on roof and down conductor above ground level complete all as specified and as directed.
Supply & replacement of Air termination single pointed Aluminium rod size of 12 mm dia & 300 mm long complete all as specified and as directed .
S&F in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required galvanised iron wire 4mm dia complete all as specified and directed.
Supply & replacement of precast RCC earrth pit cover for replacing broken/ unserviciceable pit cover with handle complete all as specified and as directed .
Taking out garbage damped over existing earthing pits including clearing the site and making serviceable earth complete all as specified and directed by Engr-in-Charge. Note :-- Material required for making serviceable the earth pit will be measured and paid for against respective items.
Rasam Engg Co.
M/S Dharam Chand Lal Chand Jain
Dwarka Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .