| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹7.6 L+₹9,554.60 (1.27%)Rejected-Finance | L2 | Rejected-Finance Not Being lowest bidder | |
| 3 | L3₹9.4 L+₹1.9 L (25.3%)Rejected-Finance | L3 | Rejected-Finance Not Being lowest bidder | |
| 4 | L4₹10.1 L+₹2.6 L (34.7%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L4 | Rejected-Finance Not Being lowest bidder |
| Sl No | Description | Qty | Unit | City buildcom builders & devlopers L1 | PRAGATI ELECTRICALS AND ELECTRONICS L4 | PRADEEP TIWARI CONTRACTOR L2 | MODI CORPORATION L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5mtr in depth and getting out in soft/loose soil for taking out U/S clogged water pipe lines & relaying after cleaning /laying of new pipe lines, complete all as specified and directed. | 153 | Cum | 97 ₹14,841 Lowest | 160 ₹24,480 | 150 ₹22,950 | 200 ₹30,600 |
| 2.00 | Returning filling in, including spreading, leveling, watering and well ramming in layers n exc 25 cm thick in soft/loose soil complete all as specified and directed. | 137.7 | Cum | 12 ₹1,652.4 Lowest | 100 ₹13,770 | 70 ₹9,639 | 50 ₹6,885 |
| 3.00 | Removing surplus excavated soil n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point. | 15.3 | Cum | 40 ₹612 Lowest | 300 ₹4,590 | 80 ₹1,224 | 100 ₹1,530 |
| 4.00 | Supply and laying sand cushioning for the purpose intrenches and laying of cables in duct/trench including and consiolidation all as specified and directed. | 3.5 | Cum | 1,500 ₹5,250 | 800 ₹2,800 Lowest | 1,000 ₹3,500 | 900 ₹3,150 |
| 5.00 | S&F Sub-Class B Brick, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. | 1.17 | Per 1000 Nos | 2,500 ₹2,925 Lowest | 5,000 ₹5,850 | 6,000 ₹7,020 | 6,000 ₹7,020 |
| 6.00Taking up or down (from wall/trenches/floor) existing steel tubing and connections, including cleaning for refixing or removal to store of following sizes:- | |||||||
| 6.01 | (a) GI pipe 20 mm dia | 50 | RM | 11 ₹550 | 20 ₹1,000 | 10 ₹500 Lowest | 10 ₹500 Lowest |
| 6.02 | (b) GI pipe 25 mm dia | 250 | RM | 12 ₹3,000 | 25 ₹6,250 | 10 ₹2,500 Lowest | 20 ₹5,000 |
| 6.03 | ( c) GI pipe 50 mm dia | 550 | RM | 12 ₹6,600 | 30 ₹16,500 | 10 ₹5,500 Lowest | 30 ₹16,500 |
| 7.00Refixing of old steel tubing and connections in new or old position including cleaning internally and externally, any grade/make in trenches/wall/floor/ceiling including all type of new fittings i.e. sockets, Tee union elbow etc all as specified and directed of follwing size:- | |||||||
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
11 Nov 2025, 6:00 pmClosed
Shri Ankit Goyal, IDSE
GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038
REPAIR/REPLACEMENT AND IMPROVEMENT OF EXTERNAL WATER SUPPLY SYSTEM, DI/GI PIPE LINE, BOREWELLS, OHT AND OTHER CONNECTED WORKS AT DSCC UNDER GE DRONACHAL
2025_MES_736020_1
8930/E8
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
BHOPAL
Class-E, Category a (ii) and as per NIT documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER DRONACHAL
₹26,000
Yes
25 Apr 2026
18 Oct 2025
13 Nov 2025
18 Oct 2025
11 Nov 2025
4 Nov 2025
18 Oct 2025 - 25 Oct 2025
Amount
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5mtr in depth and getting out in soft/loose soil for taking out U/S clogged water pipe lines & relaying after cleaning /laying of new pipe lines, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing surplus excavated soil n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point.
Supply and laying sand cushioning for the purpose intrenches and laying of cables in duct/trench including and consiolidation all as specified and directed.
S&F Sub-Class B Brick, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
Taking up or down (from wall/trenches/floor) existing steel tubing and connections, including cleaning for refixing or removal to store of following sizes:-
(a) GI pipe 20 mm dia
(b) GI pipe 25 mm dia
( c) GI pipe 50 mm dia
Refixing of old steel tubing and connections in new or old position including cleaning internally and externally, any grade/make in trenches/wall/floor/ceiling including all type of new fittings i.e. sockets, Tee union elbow etc all as specified and directed of follwing size:-
(a) GI pipe 20 mm dia
(b) GI pipe 25 mm dia
Supply , fixing & laying GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of GI new fittings for laid in trenches all as specified and directed of following size:-
(a) GI pipe 25mm dia bore
(b) GI pipe 50mm dia bore
(c) GI pipe 80mm dia bore (In lieu off 50 mm)
Supply and fixing gun metal gate valves with iron wheel head screwed both ends for galvanised iron pipe of following sizes, including taking out old unserviceable gate valves:-
(a) 25mm dia
(b) 50mm dia
Supply and fixing in replacement of float valve brass, high pressure with polythene float and fly nut complete screwed for iron pipe of following sizes:-
(a) 25 mm dia
(b) 20mm dia
Supply and fixing of rotational moulded PVC water storage tank of capacity 1000 Ltrs cylindrical vertical with closed top including taking down of old broken/tank and making connection for new tank all as specified and directed by Engr-in-charge.
Ditto but 500 litre capacity
S&F in replacement top cover lid for PVC tank as per existing size/pattern, suitable for tank capacity 500/1000/2000 ltr.
Supply and fixing in repair of foot valve assy with strainer of brass/gun metal of 50mm dia for suction pipe in U/G sump including taking out and lower the suction pipe all as directed by Engr-in-charge.
Supply, replacement and fixing Cast iron sluice valve, heavy duty (PN-1.6) with flanged ends,stainless steel spindle any pattern with iron wheel head conforming to IS including jointing and jointing materials, nuts, bolts,rubber gasket and washers etc complete all as specified of following sizes:-
(a) 100 mm bore
(b) 80 mm bore
M & L for Repair/rewinding of Submerssible pump mono block type AC, 3 phase 5 HP, Kirloskar model KVP-5684 after dismantling from its original position and disconnect from electric panel, opening the body, cutting, removing the burnt out winding and rewinding the same with appropriate supper enameled copper wire, insulating, varnishing drying etc and reassembling the motor. pump set including repair/replacement for pump set of all bearing, bush, nut, bolts, washers, coupling with pump and testing for best performance all as specified and directed by Engr-in Charge.
Supply ,installation,testing & commissioning of Centrifugal Monoblock Pumping set suction & Discharge 80 mm,Single Stage ,electric motor driven with the following technical specifications:- (i)Discharge : 500 LPM (ii)Head : Suction Head 05 mtr and Discharge Head 20 mtr (iii)RPM : 2880 (iv)Material of constraction of impellers : CI (v)Motar Rating :7.5HP (vi)Type of enclosures : Tottaly enclosed fan cooled (TEFC) (vii)Type of cooling : Air cooling (viii)Volts : 3 Phase,415+10% (ix)Coupling : Tyer type Note:- The pump has to be installed /modification of suction delivery as per site requirement .The required MS base frame incluiding with PCC foundation of required size as per OEM's recommendation of suitable construction is to be provided /fitted inclussive in quoted rate.Screwed ,fasteners,sealing material ,other miscellaneous items required for successfull testing/commissioning of the equipment are also to be provided.
M & L for repair/servicing of pump set suitable for AC, 3 phase, 7.5 HP by dismantling the pump case by opening the nuts & bolts and replacing the unserviceable impeller bearings and bush gasket, nut, bolts, washers including greasing, gland packing and rubber spacer incl transportation all as directed by Engr in Charge.
Rewinding of 7.5 HP Submersible pump set by removing old unserviceable copper winding clearing of slots and rewinding of Submersible pump set with same gauge and no of turn of copper coil which is obtained from old winding and assembling complete all as specified and directed by Engr in Charge.
M&L for taking out of UPVC water pipe of 50mm dia bore from existing bore well along with submerssible pumps, electric cable, wire rope etc for repairing of U/S submerssible pump, replacement of defective cable with the help of tripot, chain pulley all as specified and directed by Engr-in-Charge.
Supply , fixing of 50mm dia UPVC pipe (SCH-80) column/ delivery pipe of length 6 meter threaded ends included threaded couplers, and suitable end caps or plug for bore well all as specified and directed
M&L for taking out of GI water tubing heavy grade of 40mm dia bore from existing bore well along with submerssible pumps, electric cable, wire rope etc for repairing of U/S submerssible pump, replacement of defective cable with the help of tripot, chain pulley all as specified and directed by Engr-in-Charge.
Supply , fixing & laying GI tubing heavy grade with one socket both end threaded in any length including cutting threading connection in bore well and all type of GI new fittings for laid in bore well of size 40mm dia bore all as specified and directed
Materials and labour for development of Bore well by V-Notch method at site with air compressor and related accessoreis till water discharge is free from sand / mud including carryout yield test with suitable turbin pump for two consecutive days of 12 hours duration after necessary development of the tube well all as directed and specified
Supply, Fixing of old submersible electric cable PVC sheathed industrial 10 sqmm 3 Core cable copper conductor including fitting with suitable lugs etc complete all as specifed and directed.
M & L for Cleaning of underground sump by following seven stage cleaning process mentioned below after celaning process applying 2 coats of white cement base paint and marking the date of cleaning complete capacity 50000.00 ltr with white paint on black background all as directed by Engineer-in-charge for capacity of tank fifty thousand litre.
SEVEN STAGE CLEANING PROCESS:- (a)At first stage is to drain out the water by using exit valve or our own high capacity de watering system. (b) Second stage is cleaning all the algae formation inside the tank by using TERBAC-G10 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks. (c ) Thrid stage is fresh water clenaing by high speed jet pump with pressure 5 PSI (d) Fourth stage and first bacteria screening is sterilization by using TERBAC-G5 a laboratory certifed branded halogen compound,test certtificate of TERBAC-G% from government laboratory mentioning suitabiity for sterilization should be submitted to the office before using for sterilization. (e) Fifth Stage is cleaning the floor of the water tank by heavy duty industrial vacuum cleaner (f) Sixth stage is the second bacteria scseening and sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills al suspended bacteria. (g) Seventh stage oif cleaning and thiord bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidising agent TERBAC-G65.Test certificate of TERBAC-G65 from government laboratory mentioning suitability for sterilization should be submitteed to the office before using for sterilization.
Note ;- (i)Contractor shall be fully responsible for all security and sefty measures. Contractor shall deploy experienced persons in such field with insurance from reputed insurance company and also submit the certificate. (ii) Contractor shall ensure that during cleaning of tanks etc water supply system is not intrupted, Accordingly adequate manpower is deployed to complete the job within the time period given by Engr-in-Charge.
Ditto as item No- 26 here-in-before but of capacity 25000 ltrs
M & L for Cleaning of OHT by following seven stage cleaning process mentioned above in item no:22 after celaning process applying 2 coats of white cement base paint and marking the date of cleaning complete capacity 100000.00 ltr with white paint on black background all as directed by Engineer-in-charge for capacity of tank one lakh litre.
Note ;- (i)Contractor shall be fully responsible for all security and safety measures. Contractor shall deploy experienced persons in such field with insurance from reputed insurance company and also submit the certificate. (ii) Contractor shall ensure that during cleaning of tanks etc water supply system is not intrupted, Accordingly adequate manpower is deployed to complete the job within the time period given by Engr-in-Charge.
S & F in repair semi -Automatic star - Delta starter suitable for 7.5 HP Submersible motor, 415 Volts, 50Hz, 3 phase in sheet - steel enclosure MB 2S type consisting relays & contactor, pre-wiring, ON/OFF of push button, 3 phase indicating neon lamp, overload trip relay system Cat No SS96255 Model No MK1 SASD complete all as specified and directed.
S & F in repair semi -Automatic star - Delta starter suitable for 5 HP Submersible motor, 415 Volts, 50Hz, 3 phase in sheet - steel enclosure MB 2S type consisting relays & contactor, pre-wiring, ON/OFF of push button, 3 phase indicating neon lamp, overload trip relay system Cat No SS96255 Model No MK1 SASD complete all as specified and directed.
M & L for cleaning of PVC water tank of capacity 4000Ltrs by blocking out let pipe and removing sludge, mud or any other foreign material from the bottom and internal surface by brushing, draining out the water from the tank and washing internally by using bleaching powder and marking the date of cleaning etc with fluorescent white paint all as directed by Engineer-in-charge.Note: seven stage cleaning process mentioned above to be followed:-
Ditto as per Item No 31.00 above but of capacity 2000 Ltrs
Ditto as per Item No 31.00 above but of capacity 1000 Ltrs
Ditto as per Item No 31.00 above but of capacity 500 Ltrs
Dismantling existing valve chamber and Construction of brick valve pit of size 600mm x 600mm x 600 mm construction complete with Mild steel sheet cover 6mm thick and angle iron frame of size 40 x 40 x6 mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and incl locking arrangement and lifting handle all as specified and directed. All inner surface of pit shall be plastered in cement mortar (1:40 15 mm thick complete, incl excavation and earth work in any type of soil complete all as directed by Engineer in charge.
Supply and replace in repairs, XLPE insulated armoured heavy duty electric cable of size 50 Sqmm 3.5 Core with aluminium conductor 1100 Volts grade laid in trenches/floor or fixed on wall/pole including brass compression cable gland, terminal lug etc complete all as specified.
Supply & fixing MCCB, suitable for rotary handle TYPE 440 volt AC, 50 Hz, 3 pole, rupturing capacity 35 KA of capacity 125 Amps.
(a) -ditto- but 100 Amps 25 KA
(b) -ditto- but 63 Amps 16 KA
Supply & fix in repairs protection circuit breaker with short circuit and overload protection rotary type for motor of capacity 7.5 HP, type Type MOG-H1 (Rotary Type) - Frame 1 model rating 16 Amp
Supply & fix in repairs protection circuit breaker with short circuit and overload protection rotary type for motor of capacity 7.5 HP,Type MOG-H1 (Rotary Type) - Frame 1 model rating 20 Amp
M&L for scratching out old bubbled paint, finishing the surface with powder coated (smoke green) two coats synthetic enamele paint of 1st quality to LT panels at Pump house location including Panel number writting with blue colour enamel paint all as specified and directed by Engr-in-charge.
Repair/ maintenance, testing and commissioning of solar inverter panel indoor type RPI503M260000 50KW x 2 with connected accessories of make Delta , removing of dust, moisture ,checking of vermin proofing,repair, cleaning and servicing of cooling fans, air filters, checking of loose connections and repair, retightening of screws, door handles and repairing of locking arrangement, taking down of inverter from mounting structure by disconnecting of connecting wires and other accessories, transportation to civil work shop for repair, replacement of unserviceable parts and re-installation at site, making the inverter completely functional complete all as specified and as directed by Engr-in-charge. Note : (i) The unit quoted rate shall be deemed to include technically required minor spares etc (ii) Major Spares required measured and paid separately under relevent item.(iii) Major repair/ overhauling, inspection and any other functional problem to be rectified instantly.(iv) Supply only item no-4.1 to 4.11 and item no-5 of this schedule will be fixed,tested and commissioned under this item no extra cost will be paid to the contractor.
Supply only Control PCB suitable for 50 KW
Supply only cooling fan assembly suitable for 50 KW
Supply only DC input fuse or SPD
Supply only AC Contactor
Supply only MCCB 100 Amps
Visit charges for Delta authorised service Engineer including diagnostics and submission of detailed report.
M&L for cleaning and washing of 100 KW roof top solar plant including solar PV modules 330 Nos using soft water with water pump and hose reel system and appropriate non- abrasive cleaning tools like soft brushes, microfiber clothes, rubber wipers, pipes, ensuring no damage to modules and structure.Deployment of manpower and safety gears incuded the scope of job
Materials and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connected with copper strip of size 20x3mm by means of nuts, bolts, check nuts and washers made of copper or copper earthing lead to be protected by galvanised iron pipe of 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance(less than 5 Ohms) is not obtained the contractor shall redo the earthing without any extra cost to the department.
PRADEEP TIWARI CONTRACTOR (BID ID -3477377)
MODI CORPORATION (BID ID -3469653)
PRAGATI ELECTRICALS AND ELECTRONICS (BID ID -3477139)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
GPSC_8930.pdf
Tender Documents • 0.60 MB
PS_8930.pdf
Tender Documents • 0.27 MB
BOQ_824154.xls
BOQ • 2.10 MB
SOC_8930.pdf
Tender Documents • 0.26 MB
WORKLOADRETURN.pdf
Additional Documents • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .