Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAdmitted-Finance 01 PURANA DAKKHANA CIVIL LINE GANDHI NAGAR BASTI UTTAR PRADESH 272001 | BASTI | UTTAR PRADESH | 272001 | ₹2.5 L | L1 | Admitted-Finance |
| 2 | L2₹2.6 L+₹2,350 (0.93%)Admitted-Finance 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | ₹2.6 L+₹2,350 (0.93%) | L2 | Admitted-Finance |
| 3 | L3₹2.6 L+₹7,560 (2.99%)Admitted-Finance 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | ₹2.6 L+₹7,560 (2.99%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RAJA ELECTRICAL WORKS L3 | M/s Kiran Electrical works L2 | M/s Geeta Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.01 | Providing and fixing G.I. pipes of dia 80 mm nominal bore complete with G.I. fittings including trenching and refilling etc. External work | 75 | metre | 1,300 ₹97,500 | 1,250 ₹93,750 Lowest | 1,250 ₹93,750 Lowest |
| 1.02 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | 10 | point | 900 ₹9,000 Lowest | 900 ₹9,000 Lowest | 900 ₹9,000 Lowest |
| 1.03 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as reqd. | 8 | point | 500 ₹4,000 Lowest | 500 ₹4,000 Lowest | 500 ₹4,000 Lowest |
| 1.04 | Supplying and fixing 2 + 4 way/ 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. | 4 | no. | 2,000 ₹8,000 | 2,000 ₹8,000 | 1,925 ₹7,700 Lowest |
| 1.05 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of "Single Pole & Neutral" poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 6 | no. | 535 ₹3,210 Lowest | 550 ₹3,300 | 535 ₹3,210 Lowest |
| 1.06 | Wiring for light/ power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required | 80 | metre | 400 ₹32,000 | 400 ₹32,000 | 390 ₹31,200 Lowest |
| 1.07 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required | 11 | each | 450 ₹4,950 | 450 ₹4,950 | 440 ₹4,840 Lowest |
| 1.08 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 4 | no. | 350 ₹1,400 | 325 ₹1,300 Lowest | 325 ₹1,300 Lowest |
| 1.09 | Supplying and fixing of 25mm dia of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | 20 | metre | 250 ₹5,000 Lowest | 250 ₹5,000 Lowest | 250 ₹5,000 Lowest |
| 1.10 | Providing and fixing 100A TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. | 2 | each | 6,000 ₹12,000 | 5,500 ₹11,000 Lowest | 5,500 ₹11,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹3,500
Closing Date
27 Jul 2026, 9:00 amClosed
PE EnM Karo OCP
OFFICE OF PE EnM Karo OCP
Provision of Cable Protection Conduit as per GoJ Guidelines along with repairing or restrenghening of switchgears in connection with Phusro rail in motion, for uninterrupted power supply to the Rail in motion weighbridge under Karo OCP, BnK Area
2026_CCL_362090_1
P.E. / Karo OCP/ e-tender/ 2026-27/ 13
Open Tender
Electrical and Maintenance Works
Item Rate
5 days
KARO OCP
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,500
29 Jul 2026
16 Jul 2026
28 Jul 2026
16 Jul 2026
27 Jul 2026
16 Jul 2026
16 Jul 2026 - 23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Providing and fixing G.I. pipes of dia 80 mm nominal bore complete with G.I. fittings including trenching and refilling etc. External work | 75 | metre | - | - |
| 1.02 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | 10 | point | - | - |
| 1.03 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as reqd. | 8 | point | - | - |
| 1.04 | Supplying and fixing 2 + 4 way/ 6 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. | 4 | no. | - | - |
| 1.05 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of "Single Pole & Neutral" poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 6 | no. | - | - |
| 1.06 | Wiring for light/ power plug with 2 x 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required | 80 | metre | - | - |
| 1.07 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required | 11 | each | - | - |
| 1.08 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 4 | no. | - | - |
| 1.09 | Supplying and fixing of 25mm dia of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | 20 | metre | - | - |
| 1.1 | Providing and fixing 100A TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. | 2 | each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.38 MB
BOQ_374981.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .