Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹22.9 L+₹60,120 (2.70%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹24.9 L+₹2.6 L (11.6%)Rejected-AOC | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹26.4 L+₹4.1 L (18.3%)Rejected-AOC | L4 | Rejected-AOC Other than L1 |
Tender Value
₹34.5 L
EMD Value
₹68,906
Closing Date
25 Mar 2024, 6:00 pmClosed
Garrison Engineer(North) Akhnoor
Garrison Engineer(North) Akhnoor PIN 181201 CO 56 APO
COMPLETE MAINTENANCE SERVICES OF BR WORKS FOR POCKET F INCLUDING INTERNAL WIRING FOR OTM ACCN IN EAST ZONE OF GE (NORTH) AKHNOOOR
2024_MES_644050_1
CANO- GE(N)/AKH-67/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
Akhnoor
Class D Cat a i and b i
8 documents required · 8 mandatory
₹500
GE (North) Akhnoor
₹68,906
Yes
18 Jun 2024
26 Feb 2024
27 Mar 2024
26 Feb 2024
25 Mar 2024
11 Mar 2024
Amount
Receiving written complaint already entered in B/R complaint cell of AGE B/R-II for building related work such as plumbing work, water supply work, carpantry work, masonary work, blockages in WC's, kitchen/bath floor traps, gully traps & blockage in CI pipe etc. and handing over the same to the respective trade worker as per nature of complaint and submission of completion report to concerned MES staff and maintaning of record of closing of complaint on on daily basis, complete all as specified and as directed. Note: (i) Please note that different nature of complaints in one bldg/ward/Dept shall be treated as one complaint. (ii)The labour required for repair shall be paid separetaly under attending of complaint of respective nature of work here-in-after. (iii)The supply only material required in repair shall be paid separetaly under respective item.
(iv) The rep of contractor deployed to receive complaint will report daily 08:45hrs at complaint cell and attend complaints till 16:45 hrs given by Engr-in-Charge. Complaints needs to be cleared within 24hrs after receiving. The recovery will be made from the contractors dues @100 Rs. per complaint which are not cleared within 24/48hrs from the time of receipt of complaints. Decision of Engr-in-Charge in this regard is final and binding.
Attending complaints related to plumbing work/water supply work such as repair of taps by replacement of washers, tightening of taps, stop cock, angle valve, pillar cock, mixer etc, tightening of check nuts of PVC connection and making water supply functional in case of blockage, redressing of GI pipe joints if any leakage is found, repair of non-functional PVC flushing cistern by changing washers, repair/replacement of face mohra, grating etc alogwith obtaining completion from user after needful done and submit the same to MES complaint cell, complete all as specified & directed. Note:-(i) Replacement of taps, stop cock, angle valve, pillar cock,mixer, PVC connections/face mohra's of any description & any other material reqiured shall be paid separately as supply only. (ii) The contractor will supply all T&P reqiured for repair alongwith scaffolding ladders & rate of same shall be deemed to be included in in rate to quoted by the contractor. (iii) Minor item like washer, cotton, tape, screws etc. required for repair of leakage seepage in taps, pipe line etc. shall be inclussived in the rate to be quoted by the contractor & nothing extra will be admissible on this account.
Attending complaints related to spot blockage of WC seat, traps inside house and gully trap such as removing /re-fixing of grating and cleaning of WC's traps, kitchen/bath floor traps, gully traps including cleaning of blocked CI pipes upto 1st Manhole, cleaning of blocked of vertical soils/waste pipe of different dia and sewage line alogwith obtaining completion from user after needful done and submit the same to MES complaint cell, complete all as specified & directed. Note:- (i) Replacement of grating reqiured shall be paid separately as supply only. (ii) The contractors will supply all T&P reqiured for repair alongwith scaffolding ladders & rate of same shall be inclussived in rate to quoted by the contractor. (iii) Minor item like washer, cotton, tape, screws, white cement for fixing trap etc. required for repair shall be inclussived in the rate to be quoted by the contractor & nothing extra will be admissible on this account.
Supply only float valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball 15mm dia bore.
Supply only float valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball 20mm dia bore.
Supply only float valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball 25mm dia bore.
Supply only bib taps 15mm dia bore, fancy type chromium plated, cast copper alloy with capstan head.
Supply only two way bib cock 15mm dia bore, fancy type chromium plated cast copper alloy with capstan head.
Supply only bib taps standard PTMT any colour of 15mm bore.
Supply only push cock with nipple standard PTMT colour of 15mm bore.
Supply only Pillar taps 15mm bore cast copper alloy CP, fancy type with capstan head with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nut.
Supply only pillar taps standard PTMT any colour for iron pipe of 15mm bore.
Supply only brass chromium plated shower roses 125mm with or without swivel joints.
Supply only Brass CP mixer fancy type for mixing hot & cold water with sigle lever arm for iron pipe 15mm bore.
Supply only Stop valves cast copper alloy with crutch or butter fly handle for bore dia of pipe 20 mm.
Supply only Stop valves cast copper alloy with crutch or butter fly handle for bore dia of pipe 15 mm.
Supply only CP brass Stop valves/angle valve, cast copper alloy, fancy type, chromium plated for bore dia of pipe 15 mm.
Supply only Angle valve /stop cock of PTMT any colour of 15mm bore pipe.
Supply only cast copper alloy face mohra for pillar cock/bib cock/stop cock as required.
Supply only waste coupling of PTMT (half or full thread) of size 32mm bore.
Supply only waste coupling of PTMT (half or full thread) of size 40mm bore.
Supply only Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms)
Supply only urinal spreader of PTMT of size 15mm bore.
Supply only CP toilet Jet including 1m long PVC pipe & necessary nut bolts and washers.
Supply only chromium plated cast copper alloy Health faucet with one mtr long stainless steel flexible tube and wall hook.
Supply only chromium plated toilet paper holder
Supply only chromium plated stainless steel soap dish.
Supply only toughned glass shelf consisting of 5.5 mm thick sheet glass shelf 10 cm wide with chromium plated bracket guard and railing 45 cm long.
Supply only grating square/round 150mm size of PTMT minimum weight 100gms.
Supply only grating square/round 125mm size of PTMT minimum weight 40gms.
Supply only CP grating square/round 125mm size.
Supply only PVC connection 15mm size with PTMT nuts on both ends of length 600mm
Supply only PVC connection 15mm size with PTMT nuts on both ends of length 450mm
Supply only PVC waste pipe for WHB/Urinal/Sink for 32mm dia
Supply only PVC waste pipe for WHB/Urinal/Sink for 40/50mm dia.
Attending complaints related to repairing PVC Flushing Cistern by changing its internal fittings as required at site complete and obtaining completion from user after needful done and submit the same to MES complaint cell, complete all as specified & directed. Note:- (i) Replacement of unsv spare parts of flushing cistern such as float valve & syphon washer shall be included in rate to be quoted by the contractor & nothing extra will be admissible on this account. (ii) The contractors will supply all T&P reqiured for repair of flushing cistern & rate of same shall be inclussived in rate to quoted by the contractor.
S&F in repairs PVC valve less symphonic action type flushing cistern 10ltr capacity , low level white with inlet ball valve float and handle including brackets, complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel (1mm thick) kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm as approved by Engr-in-Charge complete all as specified and directed.
S&F in repairs Stainless steel kitchen sink (with out drainage board) (1 mm thick) with plugs, washers and waste pipe & couplings including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting and conecting union to pipe over all size 495 mm x 420 mm bowl size 410 mm x 330 mm x 160 mm fixed in repair complete all as specified and directed.
Rotational moulded polyethylene water storage tanks of 500 litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc. with & including "dismantling water tank exc 250 ltr and not exc 500 ltr in capacity and removing from site, complete all as specified.
Rotational moulded polyethylene water storage tanks of 1000 litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc. with & including "dismantling water tank exc 500 ltr and not exc 1000 ltr in capacity and removing from site, complete all as specified.
Attending complaints related to repair of steel window/ ventilators and other connected articles by using welding equipment and including provn of slot pin, hinge, hook and eye of standard quality where required and obtaining completion from user after needful done and submit the same to MES complaint cell, complete all as specified & directed. Note:- (i) Replacement of unsv spare parts of steel window/ ventilators such as slot pin, hinge, hook and eye shall be included in rate to be quoted by the contractor & nothing extra will be admissible on this account... (ii) The contractors will supply all T&P reqiured for repair of steel window/ ventilators & rate of same shall be inclussived in rate to quoted by the contractor.
Attending complaints related to repairing of GI tubing concealed or open including replacing of unserviceable GI socket, nipple, union, tee etc with the existing size complete including making necessary threading work to be carried upto any height or on walls for 15mm bore pipe and obtaining completion from user after needful done and submit the same to MES complaint cell, complete all as specified & directed. Note:- (i) Replacement of unsv GI socket, nipple,union, tee etc of any description shall be included in rate to be quoted by the contractor & nothing extra will be admissible on this account... (ii) The contractors will supply all T&P reqiured for repair of pipe line & rate of same shall be inclusive of the rate quoted by the contractor.
Description all as per srl Item No-43 above, but bore of pipe 20mm .
Supply & fixing in repair GI Pipe medium grade of bore 15mm including all fittings and connections fixed to wall/floor/ceiling complete all as specified and as directed.
Supply & fixing in repair GI Pipe medium grade of bore 20mm including all fittings and connections fixed to wall/floor/ceiling complete all as specified and as directed.
Supply & fixing in repair 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Supply and fixing brass elbow 3/4x12 for 20mm outer dia of CPVC pipes, complete all as specified and as directed.
Attending complaints related to rain water pipe and making functional by taking down & refixing existing PVC Rain Water Pipe, CI Pipes to wall / replacement of unsv /broken bends, rings of any dia including making the joints water tight by using suitable material, including cleaning if required work to be carried out up to any heights and obtaining completion from user after needful done and submit the same to MES complaint cell, complete all as specified & directed. Note:- (i) Replacement of unsv bends, rings etc of any description shall be included in rate to be quoted by the contractor & nothing extra will be admissible on this account... (ii) The contractors will supply all T&P reqiured for repair of rain water pipe line & rate of same shall be inclusive in rate to quoted by the contractor.
S&F in repairs 110mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed.
S&F in repairs 75mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc all as specified and directed.
S&F in repairs 110mm bore PVC Bends any radius complete all as specified and directed.
S&F in repairs 75mm bore PVC Bends any radius complete all as specified and directed.
Material and labour for Sealing of WC/Floor traps joint by using neat white cement paste and making the joint leakproof in case seepage is observed from WC/Floor trap, complete all as specified and directed.
S&F in repairs CI door lid, lid of size 100mm to C.I pipes including provision of new bolts and removal of existing broken bolts, rubber seal to make the opening leak proof complete all as specified and directed.
S&F in repairs CI door lid, lid of size 75mm to C.I pipes including provision of new bolts and removal of existing broken bolts, rubber seal to make the opening leak proof complete all as specified and directed.
PVC (SWR) 75 mm dia floor trap plain with grating including jointing with solvent cement fixed in repairs, all as specified and directed
Plastic water closet seat cover white closed pattern with flat bottom and cover including chromium plated hinges device fixed in repairs, complete all as specified and as directed.
Vitreous china wash down water closet pan pedestal pattern in white colour with 'P' or 'S' traps excluding seat cover, flushing cistern and flush pipe fixed in repairs complete all as specified and directed. Cat Part No-20011 (SLICK) of Hindware or equivalent cat part of make NEYCER, CERA, PARRYWARE as approved by GE.
Vitreous china wash basin, white, flat back, size 550x400mm including CP mixer for mixing hot and cold water for pipe of bore 15mm, waste fitting chromium plated brass, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets, waste pipe etc., fixed in repairs complete all as specified and as directed. Cat Part No. 10036 of Hindware (Model-Windsor) or its equivalent in Neycer, Cera & Parryware as approved by GE.
Vitreous china squatting pan "Orissa Pattern" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'S' trap fixed in repairs complete all as specified and directed. Cat Part No-20042 (ORISSA PAN (ECO)) of Hindware or equivalent cat part of make specified in list make as approved by GE.
Vitreous china Urinal, Half stall type, white ( excluding flushing cistern, flush pipe and waste pipe), with grating and union for discharge pipe fixed in repairs complete all as specified and directed.
Supply & fixing in repair Chromium plate Stainless Steel towel rail 60cm long including brackets, complete all as specified and directed.
Supply & fixing in repair looking mirror of size 450x600mm with PVC moulding, complete all as specified and as directed.
Supply & fixing in repair bath cabinet of size 360mmx450mmx90mm deep with glass of size 320mmx450mmx3mm thick (Make : Prayag (Symet) or equivalent make as specified in P.S complete all as specified and as directed.
Attending complaints related to carpentry work such as repair of doors/refixing /re-tightning of doors windows , welding work, resecuring of doors/window wire gauge etc including nails, screwes, fevicol, putty etc required to make good the work and attend the complaints regarding fixing, repalcement of hinges, handles ,tower bolts, sliding bolts, door spring, hydraulic door closer, door stopper, door cill, door/window shutter glass panes etc including removing broken glass (supply only hinges, handles ,tower bolts, sliding bolts, door spring, hydraulic door closer, door stopper, door cill, glass panes & wire gauge etc shall be paid for seperately under relevant item of BOQ) and obtaining completion from user after needful done and submit the same to MES complaint cell, complete all as specified & directed. Note:- (i) Minor materials like nails, screws, fevicol, putty etc required at site shall be included in rate to be quoted by the contractor & nothing extra will be admissible on this account. (ii) The contractors will supply all T&P reqiured for repair of door/ window & rate of same shall be inclussived in rate to quoted by the contractor.
Supply only GI Mild Steel wire cloth 0.47 nominal dia of wire and average width of aperture 1.18.
Supply only 03 mm thick sheet glass, ordinary quality in square not exceeding 0.5 square metre in each pane.
Supply only 04 mm thick sheet glass, ordinary quality in square not exceeding 0.5 square metre in each pane.
Supply only Helical door spring rat tail type of size 150mm including roller plate.
Supply only 150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked.
Supply only 75mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked.
Supply only 250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections.
Supply only Aluminium alloy handles, cast type, anodised of size 150mm.
Supply only Aluminium alloy handles, cast type, anodised of size 100mm
Supply only Hasp and staple safety type of size 75mm.
Supply only Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue, anodised,with hard drawn steel spring.
Supply only Door closer of aluminium (Die cast body), hydraulically regulated, designation No 3, universal type, suitable for door shutters of size 851mm to 1000mm of width , ISI marked.
Supply and fixing in repair double action door spring hydraulically regulated made of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass other parts made steel heavy duty complete all as specified and as directed.
S&F in repair 25 mm dia stainless curtain rod complete with stainless bracket and side caps fixed in position by drilling holes in wall and fixed the bracket with rawl plug and SS screw all as specified and as directed.
Taking down shutters of any description exc 1.00 Sqm and not exc 2.00 Sqm each and removing from site, complete all as specified and directed
35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated, complete all as specified.
35mm thick 2nd class hard wood Glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc devided into square with sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
Factory made 40 mm thick ,Flush shutters, solid core construction, with block board core and plywood face panels, one face is commercial on both side etc complete all as specified & as directed.
Factory made solid core PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC sheet, 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap inserted for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified & shown in relevant drawing of item No. 08080 in MES Schedule (Part-II) and directed.
Aluminium anodised, barrel tower bolts of extruded section of size 150mm and fixed, complete all as specified and directed.
250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and as directed.
Aluminium alloy handles, cast type, anodised of size 150mm and fixed, complete all as specified and directed.
Preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint of Ist quality over a coat of pink primer,complete, all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc. including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
Rendering 15mm thick on fair faces of brick work or cement concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 15mm thick on other than fair faces of brick work or stone masonry surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper including primer complete all as specified and as directed.
Preparation of newly plastered surfaces of wall and applying two coats of cement base paint including primer complete all as specified and as directed.
Preparation of old painted surfaces by washing, rubbing down and stopping of distempered or painted walls and applying one coat of oil bound distemper complete all as specified and as directed.
Preparation of old painted surfaces by washing, rubbing down and stopping of distempered or painted walls and applying one coat of cement base paint white or tined, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Glazed ceramic tiles 450 x 300 x 7mm thick / 350 x 250 x 7mm thick (coloured) on vertical surfaces such as skirtings, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in CM 1:4 complete all as specified and directed.
Non skid coloured ceramic tiles 7mm to 8mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 15mm thick screed bed/bedding layers in cement and sand mortar 1:6 complete all as specified.
Description all as per Item No.99 above, but Glazed Ceramic tiles as in skirting over and including 10mm thick plaster in CM 1:4.
Vitrified ceramic coloured tiles (light shade) 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and directed.
Taking down aluminium door shutter of any size / any description and making functional by way of repair/replacement of floor spring, hinges, lock, rubber packing etc as required and refixing in position of same opening, complete all as specified and directed.
Taking down Rolling shutters of any size from any position & making functional by way of repairs of ball bearing and spring and greasing complete and making good the surfaces and refixing in the same position of same opening, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers shall be deemed in to included in quoted rate only.)
All as per item No-105 above but for One light point/fan /bell point controlled by one switch.
All as per item No-105 here-in-before but for One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
All as per item No-105 here-in-before but for One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers shall be deemed in to included in quoted rate only.) for One 15 amps power socket outlet point controlled by one 16 amps switch on independent board.
Modular type switch 6 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and approved.
Modular type switch 16 Amps, single pole, 1way,1 module, 240V, ISI Marked Complete all as specified and approved.
Modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and approved.
Modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked Complete all as specified and approved.
Fan regulator modular type electronic compatible with BLDC fan, stepped type 100 Watts, 2 module 240Volts, AC ISI marked complete all as specified and approved.
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 12 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified. Make:- Havells cat part No-DHDPSHODPW12 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
Sheet metal enclosure factory made (Double door) for DBs, single pole and neutral, 240 volts, 8 way with 200Amps rated bus bar fixed on walls, including connecting both incoming and outgoing cable termination with proper taping, lagging, blanking plates where required testing and commissioning in replacement, complete all as specified. Make:- Havells cat part No-DHDPSHODPW08 or its Equivalent cat part of make of Legrand / ABB / L&T as approved by GE.
Sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Supply and fixing in replacement Integrel sleek surface mounted LED fitting fixture( 4 feet length), 18 watt with integral electronic driver complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size cable incl testing after fixing all as specified and directed by Engr - in-charge . The specification of the light fitting should meet the following:- (a) Housing of Light fitting : aluminium Extruded (b) Operating voltage : 150 v to 270 v (c) Operating temprature : -10 to 45 degrees (d) Lumen efficacy : 100 lumen per watt (e) system lumen : Not less than 1800 lumens (f) Colour temprature : Not less tha 5700k (g) Surge voltage protection : Up to 2 KV (h) Ingress protection : IP20 (j) Total harmonic distortion : not less than 20% (k) Power factor : not less than 0.90 (l) Input Frequency : 50 HZ (m) Line protection : Under/ Over voltage protection
Supply and fixing in replacement of 10 watt Bulkhead Designed with beautiful aesthetics using new generation technology in LED to enliven your outdoor and indoor areas in perfect synchronization with functionality and aesthetics. Family of bulkhead Lights designed to compliment thegeometry of the area with modern design. High quality polycarbonate UV Protected milkydiffuser is used for glare free light distribution complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of the panel light fitting should meet the following:- (a) Housing of Light fitting : Die cast Aluminium (b) Polycarbonate UV protected diffuser (c) Operating voltage : 140 v to 270 v (d) operating temprature : -10 to 45 degrees (e) Lumen efficacy : 100 lumen per watt (f) system lumen : Not less than 900 lumens (g) Colour temprature : Not less than 5700K (h) Surge voltage protection : Up to 4 KV (j) Ingress protection : IP65 (k) Total harmonic distortion : not less than 20% (l) Input Frequency : 50 HZ
Supply and fixing in replacement of 36 watt 2x2 panel Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/ Grid ceiling Delivers excellent illumination & comfort in high ceiling areas Long life & photobiologically safe LED’s High performance electronic driver ensures zero maintenance No harmful UV & IR radiations Environment friendly as it does not contain Mercury Instant light, High transmittance PMMA opal diffuser for glare free symmetric light distribution.Powered by an Built-In electronic driver (SMPS based constant current supply) complete making connection and testing after fixing all as specified and directed by Engr-in-charge .The specification of the panel light fitting should meet the following:- (a) Housing of Light fitting : CRCA Powder Coated (b) Operating voltage : 150 v to 270v (c) operating temprature : -10 to 45 degrees (d) Lumen efficacy : 110 lumen per watt (e) system lumen : Not less than 3600 lumens (f) Colour temprature : Not less tha 5700k
(g) Surge voltage protection : Up to 2 KV (h) Ingress protection : IP20 (j) Total harmonic distortion : not less than 20% (k) Power factor : not less than 0.90 Line protection : Under/ Over voltage protection (l)nput Frequency : 50 HZ
Supply & fixing and in repair MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed.Make:- Legrand cat No.4085 87 to 4085 95 / Hager Cat Ref No.NCN106N to NCN132N / Havells Cat No.DHMGCSPF006-032 as approved
Supply & fixing and in repair MCB SPN 32 to 40 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed.Make:- Legrand cat No.4086 17 to 4086 18/ Hager cat part No:- NCN232N /Havells cat part No.DHMGCSNF040 / L&T cat part NoBB20400C as approved
M/S KARAN SINGH CONTRACTOR
CHOPRA CONSTRUCTIONS
M/s Rajesh Kumar Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .