Col Rajinder Singh, CWE
Commander Works Engineer Military Engineer Service Junglighat Post Minniebay Port Blair 744103
80968 Repair Maintenance of HT Transformer 2 Pole structure at Prothrapur Chouldari NTS NAD and Brookshabad of AGE EM-II under GE Minniebay Port Blair
2021_MES_491550_1
80968 Rep Maint HT Transformer 2 Pole GE Minniebay
Open Tender
Civil Works - Others
Item Rate
180 days
GE Minniebay Port Blair
Class D Category b ii
8 documents required · 8 mandatory
₹500
GE Minniebay
₹59,200
Yes
27 Jan 2022
30 Nov 2021
3 Jan 2022
30 Nov 2021
28 Dec 2021
14 Dec 2021
Amount
M&L for repair/maintenance of 11KV air break gang operated triple pole switch along with DO fuse unit (Set of three), outdoor type of capacity 200/400 Amps AC,replacement of Male moving contact blade, Female contact/Fix contact Jaw,Tinned copper flexible jumber 200Amp/400Amp, MS jumber carrier,Back connector plate etc. connecting, testing complete including dismantling of unserviceable parts of gang operated triple pole switch from the structures complete all as specified and as directed. [Make: Jaipuria/ Mysore Electrical Industries/ HEI]
M&L for repair/maintenance of 33 KV air break gang operated triple pole switch along with DO fuse unit (Set of three), outdoor type of capacity 200/400 Amps AC, replacement of Male moving contact blade, Female contact/Fix contact Jaw, Tinned copper flexible jumber 200Amp/400Amp, MS jumber carrier, Back connector plate etc. connecting, testing complete including dismantling of unserviceable parts of gang operated triple pole switch from the structures complete all as specified and as directed. [Make: Jaipuria/ Mysore Electrical Industries/ HEI]
Supply and lay stone aggregate of 40mm size in 75 mm thickness underneath of 4 pole/ 2 pole structure/ transformer yard all as specified and as directed.
Supply and install lightning arrester non linear resistor type, horn gap and chocking coil complete with all fittings, transmission class, discharge capacity 65 KA, (set of Three) suitable for rated system voltage 12 KV self supporting station class type complete including taking down existing UNSV lightning arrester from 2 Pole/ 4 Pole structure all as specified and as directed. [Make: Oblum/ BHEL/ GEC-ELPRO/ Areva/ Jaipuria Brothers]
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted sections all as directed.
M&L for anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling existing rusted devices all as directed.
Dismantling/taking down serviceable/unserviceable distribution transformer of capacity up to 500 KVA from the existing platform/2 Pole/4 Pole structure/RMU after isolation of power supply and transporting to civil workshop by crane for requisite repair /maintenance and taking back to site including refixing the transformer on its original position/location, restoration of power supply and testing on completion.
M&L for opening the transformer from the top duly draining out the existing transformer oil from the transformer and keeping in a cleaned container for its re-use, taking out the complete core including winding of the transformer by lifting the same with the help of a suitable lifting equipment/machine, cleaning the transformer tank thoroughly with suitable cleaning agent after removing foreing materials, carry out the requisite repair/maint/servicing of the transformer for its smooth functioning including replacement of following unsv parts, reassembling the transformer in all respects, refilling of the transformer oil, reassembling the transformer and testing on completion of following capacities:-Di-Electric strength of Transformer oil before and after filtration should be measured and kept in record pls. Note :- Replacment of unsv parts/spares and dehydaration of transformer oil before refilling shall be measured and paid for separately under relevant items of the schedule here-in-after.
HT 11 KV/433 V 100 KVA to 200 KVA of any make and type
HT 11 KV/433 V 300 KVA to 500 KVA of any make and type
HT 33 KV/433 V 400 KVA of any make and type
Supply and fixing in replacement of silica gel breather assembly transparent type with first fill of silica gel suitable for upto 500 KVA transformers complete & connecting with proper rubberized gasket including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing in replacement of silica gel in breathers of existing transformers all as specified. [Note: The silica gel shall be brought in air tight container]
Supply and fixing in replacement of LV side gun metal/brass threaded studs of rating 1.1 KV, suitable for Transformer of Capacity up to 500 KVA of any size and length including porcelain bushing, metal rings, bolts, washers, rubber rings, etc., complete all as specified and directed suitable for indoor/outdoor type, step down transformers of any make/model.
Supply and fixing in replacement of HV side gun metal/brass threaded studs of rating 11 KV, suitable for Transformer of Capacity up to 500 KVA of any size and length including porcelain bushing, metal rings, bolts, washers, rubber rings, etc., complete all as specified and directed suitable for indoor/outdoor type, step down transformers of any make/model.
Supply and fixing in replacement of top cover gasket rubberized cork sheet 6mm thick of suitable size for transformer of 11KV/ 433 volts, up to 500KVA capacity by opening top cover of the transformer etc. including taking down old unserviceable gasket complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement of gun metal drain valve for transformer of capacity 100 to 400 KVA all as directed.
Supply and fixing in replacement of HT off load Tap changing switch of existing type/size/make
Supply and fixing in replacement of temparature gauge of existing type/size/make
Supply and fixing in replacement of Buchholz Relay suitable for transformer 33KV/433 V of existing type/size/make
M&L for on line centrifuging (filtration/ dehydration) of transformer oil including checking di-electric strength of oil before and after filtration for transformers located in various locations of AGE E/M-II Area with suitable portable machine having filtration, heating and pumping facility to improve the dielectric strength/ insulation value of Transformer oil. Notes :- (i) Di-electric strength of oil after filtration/ dehydration shall not be less than 60 KV/min. (ii) The contactor shall take shut down orders in writing from Engineer-in-charge before commencement of the work. (iii) The contractor shall ensure no wastage of transformer oil. (iv) The di-electric strength of oil shall be tested before & after filtration and test results shall be submitted to Engineer-in-Charge.
Supply and filling new transformer oil for topping up the transformers duly initialiy filtered having dielectric strength not less than 60 KV complete all as specified and as directed. [Make : Poweroil/ Electrol/ Savitha/ Tashol/ Servo]. Note :- (a) The transformer oil shall be EHV type confirming to IS - 335/1983. (b) Mineral oil grade shall be used. (c) The IR value of transformer oil shall not be less than 60KV/min. (d) The unit rate shall be deemed to include the cost of filtration to achieve desired di-electric strength before filling.
M&L for rewinding of LV/ HV coils (i.e. Primary/ secondary coils) of any size and type of 11 KV transformer of capacity 100 to 315 KVA including cleaning the burnt out insulating material, brazing and rewinding with appropriate turns and size of super enameled copper winding strip including filling insulating paper, etc., varnishing the winding with synthetic varnish including heating/ drying/ baking complete carefully and thoroughly inside the heating chamber at desired temperature to obtain required value of insulation resistance etc. complete all as specified and as directed. Make-Devidoyal Notes: (i) The unit rate quoted shall be inclusive of varnish sleeving of insulating material, taking down the clamps, upper channels and core & HT links and re-clamping, positioning with separators, brazing etc. complete. (ii) Weight of copper coil only shall be considered for payment. (iii) Rate quoted shall be inclusive of disconnecting the transformer, transportation of transformer to work shop and back to site, reconnecting , charging the transformer and Testing complete.
S&F Earth continuity conductor or main earthing lead of GI earth strip of size 25x4mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, fixed with necessary clamps and nuts, bolts etc. including taking out unserviceable strip all as directed.
Disconnecting HT supply and taking out defective trolley of VCB HT 11/33 KV, upto 1000 Amps of any make ad type and servicing of trolley of VCB by cleaning isolating contacts moving parts removing dust particles from bus bar chamber spout gear mechanism and moving parts, repair to motor charge spring mechanism tightening of nut & bolts of entire trolley components and replacement of all unserviceable spares as required and all as directed, inserting in trolley, testing commissioning and putting on the supply on load complete all as directed by the Engr-in-charge. Note: - (i) Servicing/repairs will be carried out by OEM's authorised dealer only. (ii) Spares as required for replacement will be of the same company as of existing make or as recommended by the OEM (iii) Cost of spares will be measured and paid separately under relevant items.
Supply and fix in replacement of mechanical Castle interlock assembly with Key suitable for HT 11/33 KV VCB of rating upto 1000 Amps as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of Closing coil assembly 24 Volts DC as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of tripping coil assembly 24 Volts DC as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of fixed contact block complete suitable for upto 1000 Amps, 11/33 KV HT VCB as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of LED indicator lamp suitable for operating at 110 V AC for RYB as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of HT 11/33KV PT HRC fuse AVT type 0.5 to 6 Amp and 2.5 KV to 36 KV as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of moving contact block complete as per existing make and model upto 1000 amps 11/33KV complete all as directed by Engr-in-Charge.
Supply and fix in replacement of vacuum interrupter type (4 inch dia) suitable for HT VCB 11/33KV upto 1000 Amps as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of maintenance free battery 2Volt, 26 AH Make Exide model No UPST 100.
Supply and fix in replacement of tripping push button suitable for HT 11KV/33KV VCB upto 1000 Amps as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of limit switch suitable for HT 11KV/33KV VCB upto 1000 Amps as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of charging motor button suitable for HT 11KV/33KV VCB upto 1000 Amps as per existing make and model and directed by Engr-in-Charge.
Supply and fix in replacement of pole assembly suitable for HT 11KV/33KV VCB upto 1000 Amps as per existing make and model and directed by Engr-in-Charge.
Supply & fix in renewal of current transformer resin cast copper wound double tapping/dual correct 400/200/5 Amp HT 11/33 KV having connectors for internal wiring with 15VA burden class complete all as directed by Engineer-in- Charge.
M&L for servicing and renewal/replacement of defective parts of Dry type/oil type Transformer 200 to 320 KVA 11/0.433 KV indoor door type transformer by disconnecting of HT/LT bus bar connection, opening of doors etc complete cleaning of the inside compartment, core and coils by vacuum cleaner incl lead supports, tap changer terminal boards, bushings and other insulated surfaces be wiped clean lead supports, tap changer terminal boards,bushinggs and other insulated surfaces be wiped clean with a dry cloth and all connections must be checked for tightness after cleaning up to the satisfaction of Engr-in- Charge the transformer must be meggred and connecting all connection and necessary testing complete with under mentioned scope of work. a)Cleaning of transformer from inside. b) Testing the Transformer for IR Values c) Checking/servicing/calibration of WTI for healthiness d) Magnetic Balance Test e) IR Value check before and after the work f) Voltage Ratio Test at 440 V. g) DC Logic test h) Commissioning of transformer after completion of work
Note :-1) Maintenance Shall be carried out by authorised dealer/repair of OEM. 2) Counter guarantee certificate for servicing/maintenance of dry type transformers from OEM as mentioned above shall be submitted by the tendered before quoting his competitive rates. 3) Test results obtained shall be recorded and produced to the Engr-n-Charge. 4) All Measuring equipments and T&P required shall be arranged by the contractor. 5) Any item/activity not listed/covered here above and required during /completing the overhauling work will have to be arranged by Contractor himself. 6) The rate quoted shall be deemed to include for Disconnection of Transformer HV/LV terminations for testing work and re-connections after completion of repair work. 7) Defective part measured and paid under respective item however fixing charges included. 8) Repair shall be carried out by authorised dealer/repair of OEM i.e. Volt amp Ltd.
Supply and fixing in replacement of LV bushing with studs and closing the tank top cover by fixing of suitable size of nut, bolts and washers gasket etc for the dry type Transformer of capacity upto 320KVA dry type transformer as per existing make and model complete all as directed.
Supply only in replacement HV Bushing suitable for dry type Transformer upto 320 KVA dry type as per existing make and model complete all as directeded.
Supply only in replacement Door limit switch suitable for CSS upto 320KVA KVA as per existing make and model complete all as directeded.
Supply only in replacement WTI suitable for dry type Transformer upto 320 KVA as per existing make and model complete all as directeded.
Supply and fixing heat sensor in dry type/oil type transformer upto 500 KVA as per existing make and model complete all as directeded.
M&L for isolating of power supply of LT ACB of any type/Make of capacity 1000 Amps, opening /taking out the ACB and carry out requisite repair/maint/servicing for its smooth functioning as under and refixing the ACB restoration of power supply and testing on completion complete all as specified and as directed. (a) Cleaning of pitted portion of contacts by emery paper and re-alignment of moving/fixed contact for proper alignment, complete all as directed. (b) re-setting and re-alignment of tripping and closing mechanism for proper, smooth and free operation. (c) serving of fixed carriage portion, shutter mechanism, rails etc and tightening of all nuts, bolts and fixing in position. (d) checking of all CT connection wiring etc.
Supply and fixing in replacement of Under voltage trip as per existing make and model complete all as directed.
Supply and fixing in replacement of Shunt release trip as per existing make and model complete all as directed.
Supply and fixing in replacement of Lockable Trip Push Button kit (3 I/C & 2 B/C)as per existing make and model complete all as directed.
Supply, lay, testing of HT UG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded Aluminium conductor 11000 Volts (earthed) grade of size 3 core 95sq.mm including disconnecting and taking out the existing unserviceable HT cable from trenches/ ducts/ on pole etc. all specified and as directed. Note: (i) Necessary test results like continuity test, megger tests, shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation earth work will be measured and paid separately. [Make: CCI/ Havells/ Universal/ Gloster/ Asian Cables (RPG)]
All as per Item above herein before but cable of size 3 core 120 sq.mm suitable for 13 KV
All as per Item above herein before but cable of size 3 core 95 sq.mm suitable for 33 KV
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized earth strip of 25x4mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with 20 mm GI pipe medium grade,40 mm GI pipe light grade for earth strip protection, PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion
Supply and replace danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20x15cm size all as directed.
Providing dry river sand in trenches as sand for cableducts at inside sub stations, punning down of sand in layer all as speciied. (Note :- Punned thickness shall only be measured and paid).
Supply, jointing and testing cable termination kit for 11KV (earthed) grade cable for indoor end termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 95 / 120 sq.mm all as specified. [Make: Raychem/ 3M/ Densons/ CCI]
Supply, jointing and testing cable termination kit for 11KV (earthed) grade cable for outdoor end termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 95/120sq.mm all as specified. [Make: Raychem/ 3M/ Densons/ CCI]
Supply, jointing and testing cable termination kit for 33KV (earthed) grade cable for Indoor/outdoor end termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 95sq.mm all as specified. [Make: Raychem/ 3M/ Densons/ CCI]
Supply, jointing and testing cable termination kit for 33KV (earthed) grade cable for stright through termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 3 core 95sq.mm all as specified. [Make: Raychem/ 3M/ Densons/ CCI]
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point.
Supplying and laying GI tubes medium grade 80mm bore dia in trenches/ duct/ fixed to pole/wall or in such similar position with all necessary fittings complete including taking down existing tubes all as specified and as directed.
Supply and laying in trenches or in cable ducts, DWC HDPE pipe ISI marked of size 180mm (OD) x 152mm (ID) along with connected accessories like couplers, bends, end caps etc. for UG cable protection all as specified and as directed. [Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatics Pvt Ltd.]
Service /repair of two pole structure including replacement of U/S ACSR loop joints/Jumbers and Carry out routine maint.in Switch Triple pole 33000/11000V mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating 200A and applying petroleum jelly/greasing on moving parts, testing & complete all as directed at site.
Service /repair of four pole structure including replacement of U/S ACSR loop joints/Jumbers and Carry out routine maint.in Switch Triple pole 11000V mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating 200A and applying petroleum jelly/greasing on moving parts, testing & complete all as directed at site.
M&L for preparation of old painted steel surfaces of 4 pole structure of approximate height 9.00m, consisting of 3 Nos GODs including brackets, clamps, channels and cross arms by cleaning of oils, lubricants, grease etc. complete above PCC coping and applying two coats of aluminium paint on surfaces 1m above PCC coping, applying two coats of synthetic enamel paint in zebra pattern with black & yellow colour combination up to 1m height above PCC coping; writing MES No. of poles (Number size shall be 25mm and lettering shall be 40mm) complete including applying two coats of white wash on exposed concrete surfaces of coping to poles duly preparing the surfaces all as directed by Engineer-in-Charge.
All as per item above herein before but for two pole structure complete all as directed.
M&L for spray painting with Silicon acrylic heat resistant paint of approved quality & colour to indoor/outdoor type, step up/step down transformer of up to 500 KVA capacity, installed at different location of Minniebay Area after thoroughly scraping the existing corroded paint/rust, filling of cavities complete including writing the details such as SM/MES No. all as specified and as directed.
Supply only in replacement synthtic insulating mat 2mx1mx25 mm thick suitable for HT 11/33 KV
Locating of fault for any short circuit/discontinuity in HT UG cables of any size/type by using cable fault detecting instrument/machine/equipment and taking out the damaged cable from the trench with necessary excavation upto 2 cum by manually or mechanically and rectification for suitable staraight through joint kit complete all as directed at site by Engr-in-Charge
Supply & fix for straight through joint 95/120 Sqmm 3 Core HT 11 KV/33KV heat shrinkable type complete all as specified and directed.
S&F in replacement on load changeover switch 415 V, 4 pole, 400 Amps, with sheet steel enclosure all as specified and as directed to be matched with existing type/size & to be fixed in the existing panel .
S&F in replacement MCCB 415 Volts, 250 Amps, 4 pole with adjustable thermal setting, 36KA complete connected with necessary spreader links all as specified and as directed to be matched with existing type/size & to be fixed in the existing panel .
S&F in replacement MCCB 415 Volts, 400 Amps, 4 pole C Frame,with adjustable thermal setting, 35 KA complete connected with necessary spreader links all as specified and as directed to be matched with existing type/size & to be fixed in the existing panel .
M&L for servicing of Ring main unit HT 630 Amps, 11KV, 50 Hz by removing both the sources of supply power cable carefully, checking its cable ends; removing the body cover of RMU; opening its contact blade, moving and fixed contacts, repair of moving / fixed parts, the condition of contact blades and lubricate the contact blades; repair of its drive mechanism, refixing the contact blades, moving & fixed contact, refixing its body covers, refixing the RMU with both ends of cables; necessary testing and charging the RMU all as specified and directed.
M&L for Attending the HT structure complaints of Drop out fuse cut, jumper cut , Taking down the damaged drop out fuse unit/jumper unit from the overhead structure, supply and fix new porcelain aerial fuses/ jumper with brass contact bolts and nuts, 3mm thick wire unit suitable for 11KV/33KV, with rupturing/ holding capacity up to 100 Amp. Note:- (a) Spares will be measured and paid separately under relavant items. (b) The break down complaint should be attended within 2 hours with the intimation of Engr-in-charge or concern JE E/M by telephonically / verbally. (c) Not attended of complaint within two hours will lead to recovery from subsequent payment in the following manner :- (i) Not attending within 2 to 4 Hours - Rs. 2000.00 (ii) Not attending within 4 to 6 Hours- Rs. 4000.00 (iii) Not attending within 6 to 8 Hours- Rs. 8000.00 (iv) Not attending after 8 Hours - Rs. 10,000.00 (v) The maximum recovery will be Rs. 50,000.00 plus the expenditure incurred for rectification of the same by any other means.
Cutting/ removing bushes,vegetation levelling the area around E/M installation such as sub stations, 4/2 pole structure etc. including surface excavation not exceeding 30cm deep and averaging 15cm deep and averaging 15cm deep and getting out roots, jungles etc. throw away not less than 50 mtr from the site and making good all as specified and as directed by Engineer-in-Charge.
Calibration of following relays, setting the relays for the fault levels Earth fault relay /Over current relay( Electro Mechanical) as directed by Engineer-in-Charge and testing the operation of Vacuum circuit breaker after installation of relays by simulating different types of faults all as directed by Engineer-in-charge. Note: Work should be carried out by competent service engineer of Alstom / Areva /Kirloskar/CG or Equivalent.
M&L for repairing of Transformer cooling fins, drainout Transfrmer Oil and find out the leakage position cleaning scraipling, breacing/welding of the cooling fins refiling of Transformer Oil including de-hydration and testing complete all as specified and as directed.
M&L for repair/replacement of Transformer HT side cover plate,disconect the electric supply,cutting welding and driling hole as per suitable size/thickness of sheets including nut, bolts and washer etc complete all as specified and as directed.
Supply and erect in replacement of Pre-stressed concrete pole, 11.0 meter long, 152X152mm at top and 152X260mm at bottom, class 9 complete including necessary arrangement for bypass supply to transformer complete all as as specified and directed. Note: Necessary shut down of power supply shall be done through incoming / outgoing HT 11 KV feeder pillar before the execution of said item.
Excavation in trenches, not exceeding 1.5 M wide and exceeding 1.5 M and not exceeding 3.0m in depth for foundation, etc., and getting out in hard/ dense soil complete all as specified and as directed.
M & L plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundation of poles complete all as specified and as directed.
M & L plain cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate as in coping etc. for poles complete all as specified and as directed.
M&L for providing & fixing lighting arrestors high tension suitable for 11/33 KV grade capacity expulsion type complete with all fitting transmission class discharge capacity 65 kilo Amps all as directed at side.
M&L for supply & fix dropout fuse unit consisting of fixed & moveable insulators with expulsion fuse single pole 11000 volts above 25 & upto 50 Amps capacity mounted one & including common MS channel complete as directed.
M&L for supply and fix pin type insulator porcelain vitreous white / brown / green insulators including one galvanised mild steel spindle two galvanised iron washer & one galvanised iron washer & one galvanised iron nut 100 mm height 65 mm dia for 1100 volts grade all as directed.
Supply only SRBP fuse element suitable for 11 KV, 10 Amps to 40 Amps
Supply only SRBP fuse element suitable for 33 KV, 10 Amps to 30 Amps
PTech Engineers
N Rathinam
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .