| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC D 9 NETAJI NAGAR KANTATOLI COLONY RANCHI 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹12.8 L+₹83,016 (6.91%)Rejected-Finance C O MANOJ KUMAR KESHRI MIRA SADAN ROAD NO 03 ANAND VIHAR NEAR WAXPOL FACTORY BOOTY MORE BUTI RANCHI JHARKHAND 834012 | RANCHI | RANCHI | JHARKHAND | 834012 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹13.0 L+₹1.0 L (8.63%)Rejected-Finance PURALLIA ROAD KANTATOLI RANCHI 834001 | RANCHI | JHARKHAND | 834001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹13.2 L+₹1.2 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹13.5 L+₹1.5 L (12.4%)Rejected-Finance 85 D GHOSH PARA ROAD BARRAKPORE KOLKATA PIN 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
18 Nov 2020, 6:00 pmClosed
GE DIPATOLI
GARRISON ENGINEER MES DIPATOLI MIL STN P.O. - HOTWAR RANCHI (JHARKHAND) 835217
SPL REPAIR TO ROOF GALLERY AT OR SINGLE LIVING ACCN COMPLEX OF 623 EME BN, PROVN OF FOL HYGIENE AND CHEMICAL STORE AT WKSP AREA (829 FWC) OF 623 EME BN AND PROVN OF 5X WATER COOLER FOR COOK HOUSE OF JCO MESS 163 MED REGT AT DIPATOLI MIL STN
2020_MES_388309_1
8000/1617/E8
Open Tender
Civil Works
Item Rate
120 days
DIPATOLI
CLASS E CATEGORY a(i)
7 documents required · 7 mandatory
₹500
Yes
GE DIPATOLI
₹24,000
Yes
3 Dec 2020
26 Oct 2020
20 Nov 2020
26 Oct 2020
18 Nov 2020
9 Nov 2020
Amount
M&L for roof treatment of non approachable roof including complete removal of existing roof treatment in following stages:- (i) Rendering 10mm thick in cement mortor (1:3) mixed with polymer based liquid water proofing compound, surface finished fair and even. (ii) Applying evenly a coat of bituminous primer conforming to IS:3384-1965 @ 0.30 Kg/Sqm till the roof surface is properly impregnated. (iii) Applying APP modified polymeric membrane over the bitumen coat surface, weight not less than 4.00 Kg/Sqm and over lap 100mm and sealed by torch application as per manufacturer's instructions. (iv) Applying a coat of Aluminium paint @ 200 gm/sqm in two coats over polymeric membrene. Note:- Polymer based Liquid water proofing compound shall be measured and paid seperately.
Supply only polymer based liquid water proofing compound complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for keys, scrubbing down with water, etc complete all as specified and as directed.
Demolition of brick work or rubbled stone masonry including all qoins, arches, pillars etc built in cement mortar complete all as specified and as directed.
M &L for brickwork with sub-class 'B' old size bricks, straright or corved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on wall of brick work or concrete surface, finished fair and even complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on wall of brick work or concrete surface, finished fair and even complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar (1:3) as on ceiling of brick or concrete surface, finished fair and even complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for non- skid colour ceramic tiles, 7 to 8mm thick square / rectangular, area of each tile exc 0.18 sqm but n exc 0.38sqm as in floor, with and including over 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and as directed.
Demolition of cement concrete in ground floors and paving n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregates), surface finished even and smooth without using extra cement as in plinth protection complete all as specified and as directed.
M&L for repair and rendering 10mm thick in CM (1:3) on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) with and including necessary scafolding work for double/single storey bldgs complete all as specified and as directed .
M&L for preparing the new plastered surfaces of wall and applying two coats of cement based paint after one coat of white primer complete all as specified and as directed.
M&L for preparing the old surfaces by complete removal of existing treatment and applying two coats of cement based paint on walls after one coat of white primer complete all as specified and as directed.
M&L for preparing new plastered surfaces and applying two coats of distember oil emulsion white or tinted after one coat of white primer over and including average 3mm thick cement base wall care putty on walls complete all as specified and directed.
M&L for preparing of old surfaces by complete removal of existing treatment and applying two coats of distember oil emulsion white or tinted on walls over one coat of white primer with and including over average 3mm thick cement based wall care putty on wall complete all as specified and as directed.
M&L for preparing newly plastered surfaces and applying two coats of distember oil emulsion white or tinted on ceilling after one coat of white primer over and including average 3mm thick cement based wall care putty complete all as specified and as directed.
M&L for preparing old plastered surfaces and applying two coats of distember oil emulsion white or tinted on ceilling after one coat of white primer over and including average 3mm thick cement based wall care putty complete all as specified and directed.
M&L for providing, cement concrete as in roof kerbs or mud stops, filling around hold fast etc to rounded or chamfered on edges of (1:2:4) type B1 (using 20 mm graded aggregate) complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide n exc 1.5 m deep in soft/ loose soil for foundation etc or for shaft, wells, manholes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and as directed.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc. 25 cm thick complete all as specified and as directed.
M&L for cement concret (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1: 1.50 :3) type A1 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1: 1.50 :3) type A1 (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for reinforced cement concrete (1: 1.50 :3) type A1 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.50m span complete all as specified and as directed.
M&L for reinforced cement concrete (1: 1.50 :3) type A1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of form work to pillars, posts and columns etc. complete all as specified and as directed.
Use and waste of form work to sides and soffits of plinth beam lintel beam roof beam etc complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs n.exc. 200mm thick complete all as specified and as directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floor etc exc 10cm but n.exc 20cm thick complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for mild steel TMT bars 6mm to 8mm dia as in stirrups cut to length, bent to shape required, including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for moorum/ red bajri filling in floors or pavings, laid in floors n.exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for acid resistant tiles 15 mm thick vitreous, ceramic, unglazed, set and jointed and pointed in chemical resistant materials resin type in floors and skirting etc with and including over 15 mm thick screed base in CM (1:4) complete all as specified and as directed.
M&L for white washing three coats after preparation of newly plastered surface on wall complete all as specified and as directed.
M&L for white washing three coats after preparation of newly plastered surface on ceiling complete all as specified and as directed.
M&L for prepration of new steel surface not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
S&F steel window with side hung shutter including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovatailed or welded as per IS.1038:1983 (Amendment No.3 of May 2009) complete all as specified and as directed.
S&F steel window with side hung shutter including projecting type hinges with steel handle and steel peg stay complete without glazing bars dovatailed or welded as per IS.1038:1983 (Amendment No.3 of May 2009) complete all as specified and as directed.
M&L for window guard bars fixed independetly, framed guard bars & similar work conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed.
S&F Steel ventilator with top hung shutter incl. box type hinges with steel handle and steel peg stays complete with glazing bars welded as per IS.1038:1983 (Amendment No.3 of May 2009).
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average with of aperture 1.4mm and fixed withtinnwdtack, or galvanised wire staples complete all as specified and as directed.
S & F framed work as in door or gates of angle or other section with gusset plates rails, braces etc. complete, drilled for fixing of steel sheeting or other covering.Door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging,also fastening and fixing complete all as specified and as directed.
S&F 1.00 mm thick mild steel plain black sheet in steel gates and similar works, cut to size, holes, punched including round heade screwes, clout nails or revets and fixed to steel framing with plain 40mm lap joints with reveted or welded seams, including bending or turning up, etc complete all as specified and as directed.
Surface dressing in soft/loose soil n exc 15 cm deep trimming of natural ground (removing vegetation/shurbs/ brushwood. Undergrowth and carring away rubbish to a distance of 50 metre complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and as directed.
Taking down carefully copper/aluminium submain wiring of any size from surface/concealed /existing conduit of any height and removing materials from site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and as directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed.
M&L for concealed point wiring with 2x 1.5 sqmm single core PVC insulated unsheathed copper multi stranded conductor in and including concealed PVC conduit of size 20 mm for incomer circuit and 25 mm for outgoing circuit marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch, socket etc with white laminated 3 mm thick sheet cover of suitable size complete including PVC insulated multi stranded copper conductor 1.5 sqmm as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster for One light /Fan point controlled by one one way switch complete all as specified and directed.
Description all as per ser item No. 54 here-in-before but for one 3pin socket out let 5 Amps on the same board complete all as specified and as directed.
Description all as per ser item No. 54 here-in-before but for power point with 2.5sqmm wire and earth wire on the independent board complete all as specified and as directed.
S&F switch piano type single pole 5 amp 230 v complete all as specified and as directed.
S&F socket outlet 2 in 1, 5 pin, 5 amp complete all as specified and as directed.
S&F switch piano type single pole 15 amp 230 v complete all as specified and as directed.
S&F socket outlet 2 in 1, 6 pin, 5 and 15 amp complete all as specified and as directed.
S&F ceiling rose surface type bakelite (65x50) mm three terminals complete all as specified and as directed.
S&F LED tube light fitting 1x20 watt 230 Volt with all accessories internally pre-wired and including connecting up with twin/three core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Note:- Unit rate shall include the cost of fitting and LED rod. Make:- Havells Cat Part No. LHEXBYPNIN1W020 or equivalent as per list of makes.
S&F MCB DB SPN 8 Way, 230 Volts, double door made out of CRCA mild steel sheet with epoxy power coating IP 43 & IK 09 protection surface/concealed dust and vermin proof suitable for incorporation of incomer MCCB and outgoing MCB's and making all necessary connections complete all as specified and as directed.
S&F MCB SP 6 to 32 Amps, 240 volt 'C' Series 10 KA complete all as specified and as directed.
S&F MCB SP 63 Amps, 240 volts 'C' Series 10 KA complete all as specified and as directed.
M&L for concealed sub main wiring 2 x 4 Sqmm along with earth wire 1x 4 Sqmm drawn through with and including PVC conduit not less than 25 mm dia medium grade complete all as specified and as directed. Note:- Two core of main wire one core of earth wire and PVC conduit shall be measured as one run.
M &L for GI earthing complete with GI earth plate electrode of size 60cm x 60cm x6 mm thick buried directly in ground vertically to size of ditch not less than 0.90 m x 0.60 m x 2.25 mtr, below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised iron strip of size 25 mm x 4 mm- 7.5 mtr long by means of brazing nuts, bolts, check nuts & washers, testing of completion (drawn in earth lead protection pipe light gade GI of size 15 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing lead with main switch/main control board, filling with charcoal dust, and common salt, including necessary excavation and earth work in any type of soil, perforated watering pipe, funnel with wire mesh, earth lead protection pipe light grade, PCC chamber of cement concrete (1:3:6) type C1 (for even finish on both the faces) and RCC cover (1:2:4) Type B1 of size (450 x450)mm x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed at site.
S&F water cooler electric driven (single phase), having approx storage capacity of 80 ltrs and nominal cooling capacity of 80 ltrs per hour, minimum 3 star rated, with and including connection to water cooler with GI inlet pipe of pipe line, making PCC plinth as per size of water cooler for and steel fabricated stand for water cooler as per size complete all as specified and as directed. Make:- Bluestar Model SDLX480 with 40 L Cooling, 80 L Storage(Metallic) or equivalent as per list of makes.
M/S.R.S.Chauhan and Sons
Raju Electrical and Refrigeration Works
Associated Engineers
Vp sanjiv
M/s Ray construction
Y P ANAND
M/s Mukesh and company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .