| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹15.7 LAdmitted-Finance G 15 PKT 2 NARAINA VIHAR NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | -33.99% | ₹15.7 L | L1 | Admitted-Finance |
| 2 | L2₹16.9 L+₹1.2 L (7.74%)Admitted-Finance | -28.88% | ₹16.9 L+₹1.2 L (7.74%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical B 1124 SHASTRI NAGAR DELHI 110052 | NORTH | DELHI | 110052 | - | - | - | Rejected-Technical DISQUALIFIED |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical DISQUALIFIED |
Tender Value
₹23.8 L
EMD Value
₹47,589
Closing Date
6 May 2026, 3:00 pmClosed
EE,ELD-9,DDA
EE,ELD-9,DDA
Operation and Maintenance of Clear water Booster pump set, DG set and Substation equipment at Block- A and C, Sector-28, Rohini, Ph-IV
2026_DDA_906552_1
04/EE/ELD-9/DDA/NIT/ 2026-27
Open Tender
Electrical Works
Works
365 days
Rohini
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹47,589
28-04-2026 at 12.30 P.M. in O/o EE/ELD-9
8 Jun 2026
27 Apr 2026
7 May 2026
27 Apr 2026
6 May 2026
29 Apr 2026
28 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Operation and maintenance of clear water booster pump set, DG and substation equipment and other allied accessories attached at the following site at different locations of sector-28 at Block ‘A’& 'C, Rohini as per inventory terms & conditions attached. | |||||
| 1.01 | Wireman/Pump/D.G Set operator Grd-I ,2 Nos.-1 no. for morning shift for both the pump houses i.e. from 6.00 a.m. to 2.00 p.m. and 1 No.for evening shift for both the pump houses i.e. from 2.00 p.m. to 10.00 p.m. or as when required. | - | Month | 72,422 | - |
| 1.02 | Khallasi cum Chowkidar ,2 Nos.-1 no. for each for pump house in night shift i.e. 10.00 p.m. to 6.00 a.m. | - | Month | 59,771 | - |
| 2 | Supply & replacement of following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. i/c Rebate for dismantle material.
a) 250 A,36KA,FPMCCB | - | Each | 22,438 | - |
| 2.1 | b) 400 A,50KA,FPMCCB | - | Each | 54,547 | - |
| 3 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)including rebate for dismantle material..18- 22 Watt Servicing and overhauling the following capacity DG Set of 'Kirloskar' make | - | Each | 647 | - |
| 4 | 320 KVA DG Set i/c supply and replacement of following items/ parts.
i. Mobil Oil -50 ltr.
ii. Diesel Filter -1 No.
iii. Oil Filter -1 No.
iv. Super by Pass Filter -1 No.
v. Air Filter -1 No.
vi. Coolant -30 ltr.
vii. Water temp. Gauge -1 No.
viii. O Ring -3 Nos. | - | Job | 85,291 | - |
| 4.1 | 380 KVA DG Set i/c supply and replacement of following items/ parts.
i. Mobil Oil -60 ltr.
ii. Diesel Filter -1 No.
iii. Oil Filter -1 No.
iv. Super by Pass Filter -1 No.
v. Air Filter -1 No.
vi. Coolant -35 ltr.
vii. Water temp. Gauge -1 No.
viii. O Ring -3 Nos. | - | Job | 1,11,508 | - |
| 5LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 5.1 | 100 watt | - | Each | 2,266 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.78 MB
NIT04.pdf
Tender Documents • 1.82 MB
BOQ_952872.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .