| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹15.7 LAdmitted-Finance G 15 PKT 2 NARAINA VIHAR NEW DELHI 110028 | NEW DELHI | DELHI | 110028 | -33.99% | ₹15.7 L | L1 | Admitted-Finance |
| 2 | L2₹16.9 LAdmitted-Finance | -28.88% | ₹16.9 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical B 1124 SHASTRI NAGAR DELHI 110052 | NORTH | DELHI | 110052 | - | - | - | Rejected-Technical DISQUALIFIED |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical DISQUALIFIED |
Tender Value
₹23.8 L
EMD Value
₹47,589
Closing Date
6 May 2026, 3:00 pmClosed
EE,ELD-9,DDA
EE,ELD-9,DDA
Operation and Maintenance of Clear water Booster pump set, DG set and Substation equipment at Block- A and C, Sector-28, Rohini, Ph-IV
2026_DDA_906552_1
04/EE/ELD-9/DDA/NIT/ 2026-27
Open Tender
Electrical Works
365 days
Rohini
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹47,589
28-04-2026 at 12.30 P.M. in O/o EE/ELD-9
8 Jun 2026
27 Apr 2026
7 May 2026
27 Apr 2026
6 May 2026
29 Apr 2026
28 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Operation and maintenance of clear water booster pump set, DG and substation equipment and other allied accessories attached at the following site at different locations of sector-28 at Block ‘A’& 'C, Rohini as per inventory terms & conditions attached. | ||||||
| 1.01 | Wireman/Pump/D.G Set operator Grd-I ,2 Nos.-1 no. for morning shift for both the pump houses i.e. from 6.00 a.m. to 2.00 p.m. and 1 No.for evening shift for both the pump houses i.e. from 2.00 p.m. to 10.00 p.m. or as when required. | - | Month | 72,422 | - | BI01010001010000000000000515BI0100001114 |
| 1.02 | Khallasi cum Chowkidar ,2 Nos.-1 no. for each for pump house in night shift i.e. 10.00 p.m. to 6.00 a.m. | - | Month | 59,771 | - | BI01010001010000000000000515BI0100001115 |
| 2 | Supply & replacement of following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. i/c Rebate for dismantle material.
a) 250 A,36KA,FPMCCB | - | Each | 22,438 | - | BI01010001010000000000000515BI0100001116 |
| 2.1 | b) 400 A,50KA,FPMCCB | - | Each | 54,547 | - | BI01010001010000000000000515BI0100001117 |
| 3 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)including rebate for dismantle material..18- 22 Watt Servicing and overhauling the following capacity DG Set of 'Kirloskar' make | - | Each | 647 | - | BI01010001010000000000000515BI0100001118 |
| 4 | 320 KVA DG Set i/c supply and replacement of following items/ parts.
i. Mobil Oil -50 ltr.
ii. Diesel Filter -1 No.
iii. Oil Filter -1 No.
iv. Super by Pass Filter -1 No.
v. Air Filter -1 No.
vi. Coolant -30 ltr.
vii. Water temp. Gauge -1 No.
viii. O Ring -3 Nos. | - | Job | 85,291 | - | BI01010001010000000000000515BI0100001119 |
| 4.1 | 380 KVA DG Set i/c supply and replacement of following items/ parts.
i. Mobil Oil -60 ltr.
ii. Diesel Filter -1 No.
iii. Oil Filter -1 No.
iv. Super by Pass Filter -1 No.
v. Air Filter -1 No.
vi. Coolant -35 ltr.
vii. Water temp. Gauge -1 No.
viii. O Ring -3 Nos. | - | Job | 1,11,508 | - | BI01010001010000000000000515BI0100001120 |
| 5LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | ||||||
| 5.1 | 100 watt | - | Each | 2,266 | - | BI01010001010000000000000515BI0100001122 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.78 MB
NIT04.pdf
Tender Documents • 1.82 MB
BOQ_952872.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid