Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹11.7 L+₹1.1 L (10.7%)Rejected-AOC | L2 | Rejected-AOC Not being L1 bidder | |
| 3 | Rejected-Technical HOUSE NO 22 BHAGADUTTAPUR BELTOLA RUKMINIGAON ROAD GUWAHATI 781028 | KAMRUP METRO | ASSAM | 781028 | - | Rejected-Technical Does not have appropriate c(i) category | |
| 4 | Rejected-Technical | - | Rejected-Technical Does not have appropriate c(i) category | |
| 5 | Rejected-Technical | - | Rejected-Technical Does not have appropriate c(i) category |
Tender Value
Refer Docs
EMD Value
₹19,800
Closing Date
14 Sept 2024, 6:00 pmClosed
GE (P) AF Digaru
GE (P) AF Digaru PO Digaru Dist Kamrup Assam 782401
REPAIR/MAINTENANCE AND SERVICING OF SUMMER COOLING APPLIANCES, WATER COOLER, REFRIGERATOR, DEEP FREEZER, VOLTAGE STABILIZERS AND OTHER ALLIED WORKS AT AF STN DIGARU
2024_MES_650618_2
C/8719/E8 of 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Digaru
Please ref Tender Documents
6 documents required · 6 mandatory
₹500
GE (P) AF Digaru
₹19,800
Yes
28 Oct 2024
31 Aug 2024
21 Sept 2024
31 Aug 2024
14 Sept 2024
9 Sept 2024
Amount
Taking out water storage tank carefully from the system, soldering to the water tank to prevent water leakage and re-fixing the water tank inside the water cooler of 150/80 ltrs capacity.
M&L in repair/replacement of the internal electrical circuit by flexible copper insulated conductor of suitable size with thimbles, sockets etc all as required at site for water coolers having 80 ltrs capacity.
S&F of Lid gasket set (top & bottom) of required size suitable for 40/80 ltrs cpacity water coolers including taking out old worn out gasket set.
Installation of water coolers after repair including connecting to water supply system and electrical system, properly testing for cooling, auto cut ON/OFF of the system, sound less & vibration proof working system complete all as directed and satisfaction of Engineer-in-Charge.
M&L for re-insulation with glass wool/thermocol to pre-cast the water tank from external heat as required at site for water coolers of any size and capacity complete all as directed at site by Engineer-in-Charge.
Servicing & cleaning of water cooler by taking it out from the existing place, clearing with blower and soap water solution, making dust free to the system, tightening all nuts, bolts, screws etc, oiling to blower motor and refixing the water cooler in existing place properly to make sure that there is not extra sound from water cooler complete all as directed and satisfaction of Engineer-in-Charge.
Supply and fixing in repair/replacement of PVC pipe connection, both end screwed 18” long 15mm dia with brass nuts and neoprene washers for water cooler/ desert coolers etc complete all as directed.
Dismantling/taking out water cooler for major repair such as repair/replacement of compressor, fan motor, tank repair etc of any makes & size from any place and any capacity, transported to workshop & back complete all as specified and directed. Note:- Replacement of damaged parts i.e. compressor, fan motor etc. shall be measured & paid seperately.
Supply and fixing in repair/replacement of Compressor (Sealed unit) suitable for 60/120 Ltr capacity Water Cooler.
Supply and fixing in repair/replacement of Compressor (Sealed unit) suitable for 40/80 Ltr capacity Water Cooler.
M&L for Gas Charging of Water Cooler 60/120 and 40/80 Ltr capacity including necessary R-22/ R-134 gas, filter, anti moisturising agent, soldering /brazing, necessary copper capillary tube any size and testing complete. Note:- Cost of Refrigrant gas shall be deemed included in quoted rates.
M&L for submain wiring with two single core FRLS PVC insulated multi stranded copper conductor cable 4 Sqmm including rigid heavy duty PVC conduit size 25 mm dia in existing surface including all accessories along with 4.0 Sq mm PVC insulated copper standard conductor earth wire connected to main wring system complete all as specified & directed.
Supplying and fixing starting capacitor 60 to 80 MFD suitable for water cooler SRA-300/400/200 complete all as specified & directed.
Supplying and fixing running capacitor 30 MFD suitable for water cooler SRA-300/400/200 complete all as specified & directed.
Supplying and fixing running capacitor 15 MFD suitable for water cooler SRA-300/400/200 complete all as specified & directed.
Supply and fixing in repair/replacement of Push type C.P cock for water cooler. Make :- L& K / Leader/ sona/ Ess-Ess.
Supply and fixing in repair/replacement of float valve 15mm dia complete all as specified & directed.
Supply and fixing in repair/replacement of water drain-out tary stainless-Steel (thickness - 0.71) for water cooler any make /size with PVC waste pipe, pipe clamp complete all as directed.
Disconnecting the refrigerators from the system for servicing/cleaning, taking out regrigerators form the existing places, clearing with blower and soap water solution making dust free to the system tightening all nuts bolts screws etc, refixing the refrigerators in existing places properly to make sure that there is not extra sound from refrigerators.
S&F in repair/replacement of Cooling coil/Evaporator coil complete for refrigerators of different makes and different capacities i.e 165/180/300 ltrs including taking out old unserviceable cooling coils.
S&F in repair/replacement of suitable size Chill tray for refrigerator of 165/180/300 ltr capacities after taking out old chill tray.
S&F in repair/replacement of Door gasket for refrigerator after taking out old unserviceable door gasket set.
S&F of Plug top 15/16 Amps capacity.
S&F PVC stand for refrigerators of 165/180/300 ltr capacities.
S&F Vegetable tray for refrigerators of 165/180/300 ltr capacities.
M & L for strainer suitable for all type of Refrigerator.
Taking out unserviceable compressor from refrigerator of capacity 165 to 310 ltr of any make by un-screwing from base plate after disconnecting all electrical and suction / discharge pipe connections complete and fixing compressor (sealed unit) and providing all electrical connections to respective terminals including changing of unserviceable connecting wires as per the existing. Brazing of suction and discharge lines with new compressor and vacuuming the system and testing / rectification of leakage, charging of refrigerant gas as per requirement to achieve proper cooling effect and testing on completion complete all as specified and as directed. Note :- Compressor (sealed unit), Refrigerant Gas and Spare Parts required for replacement for satisfactory repair shall be paid and measured separately under relavant items.
M&L for Gas Charging of refrigerators having 165 Ltr to 310 Ltr capacities including R-22/134/310 gas, filter, anti moisturising agent, soldering/brazing, necessary copper capillary tube of any size and testing complete all as specified and satisfication of Engr-in-charge. Note : Cost of Refrigerant gas shall deemed to be included in quoted rates.
Supply and fixing in repair/replacement of Compressor (sealed unit) with relay suitable for refrigerators of capacity 200 to 280 ltrs complete all as specified & directed.
All as per srl item No. 29 above but for capacity of 165/175 ltrs.
Supply and fixing in repair/replacement of Thermostatic switch with knob suitable for Refrigerator. Make :- Indfoss/ Ranutrol
Supply and fixing in repair/replacement of Overload protection relay suitable refrigerator any capacity. Make :- Sriram/ Ranutrol/ Indfoss
Removing rusted worn out bottom base portion of refrigerator/deep freezer of any size and type including welding and making the surface as original along with painting with one coat of red oxide primer and two coats of super synthetic enamel paint matching to the original colour of refrigerator complete all as specified and directed by Engr-in-Charge.
Taking out unserviceable compressor from Deep Freezer of capacity 310/320 ltr of any make by un-screwing from base plate after disconnecting all electrical and suction/ discharge water pipe connections, fixing new compressor (sealed unit), making all electrical connections to respective terminals including changing of unserviceable connecting wires as per the existing, brazing of suction and discharge lines with new compressor and vacuuming the system and testing / rectification of leakage, charging of refrigerant gas as per requirement to achieve proper cooling effect and testing on completion complete all as specified and directed by Engr-in-charge. Note :- Compressor (sealed unit), Refrigerant Gas and Spare Parts required for replacement for satisfactory repair shall be paid and measured separately under relavant items.
M&L for Gas Charging of Deep Freezers having 310 to 320 Ltr capacities including R-22/134/320 gas, filter, anti moisturising agent, soldering/brazing, necessary copper capillary tube of any size and testing complete. Note:- Cost of Refrigerant gas shall deemed to be included in quoted rates.
S&F in repair/replacement of Compressor (sealed unit) with relay suitable for Deep Freezer of capacity 310 to 320 ltrs all as specified and as directed by Engineer-in-Charge.
S&F in repair/replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amps MCB, 240 volt complete all as spacified and directed.
Supply and fix MCB single pole 25 Amps 240 volts, 50 Hz , 10 KA 'C' series in existing distribution board.
Supply and fix MCB single pole and neutral 32 Amps 240 volts, 50 Hz , 10 KA 'C' series in existing distribution board.
Taking down unserviceable Window/Split Air Conditioner of any capacity make by un-screwing from base plate after disconnecting all electrical and suction / discharge pipe connections complete and making necessary repairs as required like fixing new compressor (sealed unit) and providing all electrical connections to respective terminals including changing of unserviceable connecting wires as per the existing. Brazing of suction and discharge lines with new compressor and vacuuming the system and testing/ rectification of leakage, fixing cooling coil, charging of refrigerant gas as per requirement to achieve proper cooling effect and testing after refixing in position complete all as specified and directed by Engr-in-Charge. Note:- Compressor (sealed unit), air cooling coil, condensor coil, Refrigerant Gas and spare parts required for replacement for satisfactorily repair shall be paid and measured separately under relavant items.
M&L for Refrigerant Gas ie R-22/134/320 or any other suitable gas for charging of Split/ Window type AC units of capacity of 1.5/2 TR including necessary filter, anti-moisturising agent complete all as specified and directed.
Supply and fixing in repair/replacement of Copper Pancake Coil Nitrile Foam Insulation Tube, Class-1, Inner Diameter - 1/2 Inch (12.7mm) & Wall Thickness - 19 mm, Pack of 1 Pcs of 2m length for suction and discharge line copper tubing for split type AC 1.5/2 ton capacity complete all as specified & directed.
Supply and fixing in repair/replacement Filter as per sample for split/window type AC complete all as specified and directed.
Supply and fixing in repair/replacement of Copper Tubing of suitable size1/2"and 3/4" for suction and discharge line two run for split type AC with insultion to protect the heat etc. complete all as specified & directed.
Supply and fixing in repair/replacement of cooling/ condensor coil for outdoor unit of split type AC suitable for 1.5/2 ton etc. complete all as specified & directed.
Supply and fixing in repair/replacement of air cooling/evaporator coil for indoor unit of split type AC suitable for 1.5/2 ton etc complete as as directed.
Supply and fixing in repair/replacement of auto circuit plate (PCB) 220V, 50Hz suitable for Window Type AC complete all as specified & directed.
S&F in replacement of Swing Motor, type C, 12V DC, 4 hole, 5 wire suitable for 1.5/2.0 TR Split type Air Conditioner complete all as specified & directed.
Supply and fixing in repair/replacement of Connection lead wire, two single core with PVC insulated and sheathed copper cable size 4.0 Sqmm including earth wire complete all as specified & directed.
Material & Labour for unplasticised PVC pipe of pressure rating 100 Kg/Cm2 fixed complete to walls, ceilings or in floors etc of size 15mm dia (outer dia) including chase cutting on wall & making good as per existing complete all as specified & directed.
Universal AC Remote for all types Air Conditioners of capacity, type & make as directed.
M&L for shifting of split AC unit including dismantling of indoor and outdoor unit and mounting arrangement and refixing in new location by fixing mounting arrangement, topping up gas complete all as specified and directed by Engr-in-Charge.
Material & Labour for repairs to Voltage stabilizer of 4/5 KVA capacity, single phase, 230 Volts of various make after disconnecting incoming and outgoing electric connection and carry out minor repair work such as repairing of internal worn out wires, repair to electronic circuit plate, low/high cutoff circuit and replacement of unserviceable parts including testing by connecting on load and adjusting low/high cutoff and timing relay all as directed. Note :- Spares required for replacement shall be measured and paid separately as "Supply only" under relavant items.
Supply only Electronic circuit plate (PCB) with timer, high and low cut off suitable for 4/5 KVA stabilizer.
Supply only Relay 5 Amps 230 volts suitable for 4/5 KVA stabilizer.
Supply only Relay 30 Amps capacity suitable for 4/5 KVA stabilizer.
Supply only Indicator lamp complete for AC 230 Volts Red or Green round shape as per requirement.
Supply only Voltmeter 0-300 volt round/square type. Make :- AE/IMP/Volini/Voltas
Supply and fixing in repair/replacement of Main transformer with super enamelled copper wire of suitable size including varnishing and heating complete suitable for 4/5 KVA.
M/s Ravi Enterprise (BID ID -3095342)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .