Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹34.9 L+₹73,454.34 (2.15%)Rejected-AOC 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC OK | |
| 3 | L3₹35.2 L+₹1.1 L (3.26%)Rejected-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC OK | |
| 4 | L4₹35.4 L+₹1.3 L (3.86%)Rejected-AOC MAIN ROAD KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU AND KASHMIR | 181221 | L4 | Rejected-AOC OK | |
| 5 | L5₹35.9 L+₹1.8 L (5.13%)Rejected-AOC PLOT NO 60 PHASE II HOUSING COLONY DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC OK |
| Sl No | Description | Qty | Unit | SHIVAE CONSTRUCTION L2 | K S BUILDERS L1 | M/S SANJAY STEEL WORKS L4 | DAVINDER SINGH L3 | MAHADEV ENTERPRISES L6 | M/S SHUBAM ENGINEERS L5 | PARAS RAM ASGOTRA AND SONS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of plain, corrugated or semi corrugated sheeting, of any description, roof coverings all as specified. | 565 | Sqm | 0.5 ₹282.5 Lowest | 6 ₹3,390 | 5 ₹2,825 | 2 ₹1,130 | 10 ₹5,650 | 7 ₹3,955 | 2 ₹1,130 |
| 2.00 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and complete all as directed and specified. | 530 | Sqm | 575 ₹3,04,750 Lowest | 606 ₹3,21,180 | 620 ₹3,28,600 | 600 ₹3,18,000 | 750 ₹3,97,500 | 610 ₹3,23,300 | 690 ₹3,65,700 |
| 3.00 | S&F painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,eaves etc fixed with self tapping screws as specified complete all as specified as directed. | 35 | Sqm | 575 ₹20,125 Lowest | 606 ₹21,210 | 620 ₹21,700 | 575 ₹20,125 Lowest | 650 ₹22,750 | 605 ₹21,175 | 690 ₹24,150 |
| 4.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. | 4.5 | Qtl | 25 ₹112.5 Lowest | 26 ₹117 | 50 ₹225 | 50 ₹225 | 100 ₹450 | 90 ₹405 | 100 ₹450 |
| 5.00 | S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality A all as specified and directed. | 450 | Kg | 80 ₹36,000 | 66 ₹29,700 Lowest | 90 ₹40,500 | 80 ₹36,000 | 70 ₹31,500 | 78 ₹35,100 | 83 ₹37,350 |
| 6.00 | Framed work such as grills, gratings etc with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290 Gde E-165. | 100 | Kg | 80 ₹8,000 | 66 ₹6,600 Lowest | 80 ₹8,000 | 66 ₹6,600 Lowest | 85 ₹8,500 | 74 ₹7,400 | 90 ₹9,000 |
| 7.00 | M&L for taking down existing roof treatment of any description and any type and position and removing the deberis from site outside MD land all as specified and directed by Engr-in-Charge | 35 | Sqm | 2 ₹70 Lowest | 16 ₹560 | 15 ₹525 | 10 ₹350 | 20 ₹700 | 10 ₹350 | 10 ₹350 |
| 8.00 | M&L for rendering 15mm thick in CM 1:4 on of brick work or concrete surface incl Brushing neat cement slurry with 3.0kg of cement per sq. metre finish ever and smooth (w/o using extra cement) incl WPC as per user manual at any height etc complete all as specified and directed. (WPC will be measured and paid separately). | 35 | Sqm | 100 ₹3,500 | 196 ₹6,860 | 150 ₹5,250 | 160 ₹5,600 | 150 ₹5,250 | 70 ₹2,450 Lowest | 150 ₹5,250 |
| 9.00 | M&L for Roof treatment for Non Accessible Roof :- priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm, Top surface of roof after carrying out treatment as specified here in above as per manufactur instructions, complete all as specified | 35 | Sqm | 350 ₹12,250 | 206 ₹7,210 Lowest | 390 ₹13,650 | 600 ₹21,000 | 350 ₹12,250 | 280 ₹9,800 | 450 ₹15,750 |
| 10.00 | M&L for Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment, complete all as specified. | 35 | Sqm | 50 ₹1,750 Lowest | 66 ₹2,310 | 60 ₹2,100 | 160 ₹5,600 | 70 ₹2,450 | 60 ₹2,100 | 100 ₹3,500 |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
19 May 2025, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
SPL REPAIR TO BUILDING NO P-60 OR LIVING LINE OF LT AD REGT COMP AT DHAR ROAD GRN UNDER GE ARMY DHAR ROAD. JOB NO Z SRB-45 2024-25
2025_MES_704776_1
8071/NIT-03/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹87,400
Yes
11 Aug 2025
19 Apr 2025
21 May 2025
20 Apr 2025
19 May 2025
5 May 2025
Amount
Dismantling of plain, corrugated or semi corrugated sheeting, of any description, roof coverings all as specified.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and complete all as directed and specified.
S&F painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,eaves etc fixed with self tapping screws as specified complete all as specified as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality A all as specified and directed.
Framed work such as grills, gratings etc with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290 Gde E-165.
M&L for taking down existing roof treatment of any description and any type and position and removing the deberis from site outside MD land all as specified and directed by Engr-in-Charge
M&L for rendering 15mm thick in CM 1:4 on of brick work or concrete surface incl Brushing neat cement slurry with 3.0kg of cement per sq. metre finish ever and smooth (w/o using extra cement) incl WPC as per user manual at any height etc complete all as specified and directed. (WPC will be measured and paid separately).
M&L for Roof treatment for Non Accessible Roof :- priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter provide polymeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm, Top surface of roof after carrying out treatment as specified here in above as per manufactur instructions, complete all as specified
M&L for Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment, complete all as specified.
M&L for 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) for roof pedding, finish even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge
Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards /slabs / blankets, any thickness, including cover fillets
S&F Anodised aluminium snap grid frame work for false ceiling for size of grid 605 x 605 mm including hangers 6 mm dia GI (up to 1200 mm long) adjusting level fixed to roof complete all as specified
S&F 4mm thick non asbestos fibre cement designer board ISI Marked fixed with screw to aluminium frame work in ceiling flat or sloppy as per manufacturer instructions complete all as specified
Demolition of stone slab and tiles of any description or thickness on cooking platform, floors, aprons, skirting etc laid bedded and pointed in any morter complete all as specified and directed
M & L for Machine cut 18-20 mm thick Kota stone slab flooring as in treads of staircase over cement screed base 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor finishes and finishing smooth and even without using extra cement all as specified and directed.
M & L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar, laid over cement screed of 10mm in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
M & L for Granite (of any type) work, 18-20 mm thk (table rubbed and polished) in steps, jambs, pillars, top of slab, skirtings with necessary hole where ever required and cement mortar bedding of 20mm thick in CM 1:6 including pointing in white cement using marble dust with admixture of pigment to match including rounded edges with shade of granite complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store yard and rubbish off the premises as directed.
M & L for Providing and injecting chemical chlorpyrifos emulsifiable concentrate for Post Constructional Anti termite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron.
M & L for Anti termite Treatment of soil under existing floors using chemical chlorpyrifos emulsifiable concentrate @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors all as specified .
M & L for Glazed Ceramic coloured tiles in vertical surface 450X300X7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including 10mm thick backing coat of cement mortar (1:4), complete all as specified and directed
M&L for Non skid ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.18 sqm not exceeding 0.38, as in floor laid on 10mm thick cement plaster in CM (1:4) , set and jointed in neat cement slurry at the rate of 3 kg per sqm and pointed in white/coloured cement to match the shade of tiles.
Demolition of Brickwork or stone/ boulder masonry, built in CM incl all quoins, arches, pillars, etc, complete all as specified and directed .
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as directed.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc including removal of debrish from the MOD land complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per manufacturer instructions at any height etc complete all as specified and directed. (WPC will be measured and paid separately).
M&L for rendering 10 mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed. .
Supply only liquid WPC
M & L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care Putty complete.
M & L for Preparing new plastered or unplastered surfaces of wall and applying exterior emulsion paint white or tinted over & including a coat of wall care Putty specified for external surface as per manufacturer instruction complete.
M & L for preparing new plastered surface of ceiling and applying three coats of white wash complete.
M&L for complete removal of existing treatment on walls by electrical grinder/ sand paper/ steel patti thereafter prepartion of walls by filling of holes and cracks with wall care putty, specified for external surface as required area of surface and applying two coats of exterior emulsion paint (weatherproof /Apex) over a coat of wall care Putty specified for external surface as per manufacturer instruction,scomplete.
Complete removal of existing treatment , wahsing down and stopping of distempered and painted surfaces and old plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & over a coat of wall care putty complete.
Complete removal of existing treatment, washing down and stopping painted surfaces and preparing old plastered or unplastered surfaces of wall and applying three coats of white wash complete.
M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scraping and filling of holes and cracks with suitable material like cement or plaster of Paris etc and there after applying one coat of Cement base paint on walls complete
M&L Preparation of new plaster surfaces apply two coat of cement base paint over a coat of primer.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each and all as specified and directed.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 sqm each and all as specified and directed.
M&L for pressed steel frames of size 125mmx60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets with and including necessary fixing lugs, hinges (100mm medium weight-03 Nos on each rebate), lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar 1:6, complete all as specified.
M&L for factory made solid PVC moulded door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification & drawing and all as directed by the Engr- in-Charge.
S&F for Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face & fixing in frame at site as per specification & drawingand as directed by Engr-in-Charge.
S&F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete as specified.
S&F 35 mm thick factory made II class Hard wood glazed and Skelton shutters (three panels) open rebated and prepared to receive and including glass/gauge , wiremesh etc divided into squares edges of framing Plain, chamfered or rounded mitered and rebated sash bar any number with cut or mitered beads for securing glass/gauge etc Size of members of shutters complete as specified
S&F MS butt hinges medium weight cold rolled mild steel 100mm
S&F for aluminum anodized barrel tower bolts of extruded section 150mm long (ISI Marked) complete all as specified and directed.
S&F for aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, 300mm long, complete all as specified and directed.
S&F for aluminum handles cast type anodized 150mm long (ISI Marked) complete all as specified and directed.
S & F Floor door stopper (double leg) of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor; overall length of cover plate 60mm complete.
S&F 300mm long ordinary rat tail rod pattern spring incl roller and plate fixing wooden/MS door frame as requird, complete all as specified
S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and avg width of aparture 1.18mm complete all as specified and directed
M & L for preparation of new wooden surfaces of any description not otherwise described over 10 cms width or girth and apply two coats of synthetic enamel paint over a coat of pink primer all as specified.
Dismantling wrought iron or mild steel/cast iron work of any description (steel window & Grill) complete all as specified and directed.
S&F in repair Steel window with side hunge shutters incl projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded with one shop coat of red oxide primer, and two coat of synthetic enamel paint, complete all as specified and directed.
S&F in repair Steel window with side hunge shutters incl projecting type hinges with steel handle and steel peg stay complete without glazing bars dovetailed or welded with one shop coat of red oxide primer, and two coat of synthetic enamel paint, complete all as specified and directed.
S&F in repair for Steel window or ventilator fixed type with glazing bars.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as directed and specified.
S&F for 25 mm dia decorative/fancy type stainless steel curtain rod with brackets and knobs at both ends as per site requirement incl taking down old existing pipes with accessories complete all as specified and directed. Note: the cost of brackets and knobs is deemed to be incl in the quoted rate.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, as directed by the Engr-in-charge.
M&L for RCC Nominal mix type B1 1:2:4 (20mm graded aggregate) in landings, chajjas,shelves and similar articles with plain faces, set in cement mortar 1:4, including necessary form work complete all as specified and directed.
M&L for TMT Bar 10mm dia and over cut to length bend to shape required incl cranking, bending sprilly for hooping colmns hooking ends and binding with and incl MS wire (Anneled) not less than 0.9mm dia or securing with clips
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching/ filling in hold fast, pressed steel frame and all other similar works including necessary formwork complete all as directed.
M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm agg. ) as in plinth protection / path/ any paved area complete all as specified and directed.
Dismantling water tanks exc 1000 & n exc 2000 capacity in litres and removing to contractors store
S&F for 2000 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position icluding 20 mm ball brass valve complete all as specified
S&F in ball brass valves, 20 mm bore, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed.
S & F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore complete.
S&F for Health faucet brass chromium plated with 8mm dia 1.2 mtr long flexible pipe and wall hook fixed with brass chromium plated screws, complete all as specified.
S&F in repair 15 mm dia brass chromium plated angle valve fancy type (quarter turn), screwed at ends including necessary extention piece and fixed complete.
S & F in repair Bib tap CP fancy type long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings all as specified and directed.
S&F in repairs PVC low level white flushing cistern, valveless syphonic action type 10 ltr capacity with inlet, ball valve, float and handle including PVC flush pipe 32mm dia bend and a pair of mild steel iron brackets of suitable size including making necessary connection to water supply pip line and, complete all as specified and directed
S&F in repairs for vitreous china ware Wash Hand Basin, white, flat back of size 550 x 400 mm including brackets, cutting for and pinning in ends of brackets or erecting stand including brass CP union/waste fitting of 32mm dia and discharge pipe of 32mm dia PVC of 1.0 m length with all fittings etc complete all as specified and directed by Engineer-in-Charge
S & F in repair Vitreous china squatting pan ‘Orissa’ pattern, size 580 x 440 mm, coloured, with integral foot rests, fixed in repairs squatting pan including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete.
S&F for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush pipe) incl connection to drain and flushing pipe in repairs complete all as spd and directed.
S&F in repair wast pipe 32/40 For WHB and sink mm complete all as specified and directed. .
S&F in repairs grating doom 125mm dia of steel (minimum weight 40gms) with waste hole complete all as specified and directed.
Supply and fixing tubular towel rail 20mm dia, D type, 60cm long between flanges all as specified and approved.
S&F mixing valve 15mm dia,Hot& cold CP brass fancy including joints to steel pipe or unions for centre hole wash hand basin , including fittings complete all as specified and directed by Engineer-in-Charge. (Make :Jaquar, Marc, Gem )
Supply and fixing in repairs brass chromium plated shower roses 125mm with or without swivel joints, any size, including fixing to steel pipe or union all as specified.
S&F in repairs for PVC connections 15mm heavy duty hot and cold size with PTMT nuts of length 600 mm complete all as specified and directed.
Taking up or down steel tubing and connections all as specified. 15 mm bore complete all as specified.
Taking up or down steel tubing and connections all as specified. 20 mm bore complete all as specified.
Taking up or down steel tubing and connections all as specified. 25 mm bore complete all as specified.
Cutting chases or making holes, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth.
S&F GI tubing 15 mm bore medium grade galvanised with all fittings, laid in walls, ceiling, floors, etc all as specified.
S&F GI tubing 20 mm bore medium grade galvanised with all fittings, laid in walls, ceiling, floors, etc all as specified.
S&F GI tubing 25 mm bore medium grade galvanised with all fittings, laid in walls, ceiling, floors, etc all as specified.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and MS ring (25x6 FI used) bolt at every 1.5 mtrs length complete , incl taking up/down old pipe with all fittings all as specified and directed by Engineer-in-charge.
All as per ser item No above but laid in trench or in floor
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed. .
S&F for 110mm bore PVC bends/junction with access door any radius complete all as specified and directed. .
S&F for 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed. .
S&F for 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. .
S&F for 75mm dia PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. .
S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings all as specified and directed by Engineer-in-charge.
'Ditto all as per ser item No above but laid in trench or in floor
S&F for 75 mm bore PVC bends/junction any radius complete all as specified and directed. .
M&L in repairs for cast iron Nahani trap/floor trap with CP grating including jointing with cement joint to waste pipe of 100 mm dia fixed in cement concrete type B-1(1:2:4) complete all as specified
Demolition of cement concrete in floors of any description complete all as specified.
M & L 25 mm thick PCC 1:2:4 using 20 mm graded stone aggregate over 250 thick lime concrete type E2 ( 1:3 ) with 40mm brick bats as in filling of sunken floors over a layer of polyethylene film black 50 micron over a layer of bitumen blown any grade applied hot (1.5 Kg/sqm) over 10mm thick plaster in cm 1:3 with WPC @2% by wt. of cement including treatment to side wall of sunken complete all as specified & directed. Note Over all floor area only be measured for payment, rate for side wall deemed to be included.
M & L of Cement concrete in foundations,filling and mass concrete type C2 1:3:6 (40mm graded aggregate) complete all as specified and directed by engineer-in-charge.
Demolition of cement concrete unreinforced in ground floors and paving n. exc 15 cm thickness below or above gound level , concrete debris and rubbish to a distance n exc 100m as directed by the EIC.
M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block of 60mm thickness, any shape and size confirming to IS 15658 -2006 with grey cement, pigment complete all as specified and directed.
M & L for sand filling under floors or in foundation or as in sand coushing incl watering and consolidation complete all as specified.
M&L for Factory made Pre-cast cement concrete block type B1, 1:2:4 as in kerb stone made to shape as directed, exc. 10 cm in width and setting in mortar 1:4, complete all as specified and as directed.
Excavating in trenchs n exc 1.5m in depth and n exc 1.5m wide for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out soft/loose soil complete all as specified & as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified & as directed.
Removing excavated soil material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified & as directed.
S&F for laying in trenches, jointing and testing salt glazed stoneware pipe grade 'A' drainpipe 150mm bore conforming to IS at any depth after they are laid and tested complete all as specified & directed.
M&L for PCC 1:3:6 type C2 as in concrete bed to 150 mm bore drain pipe and over incl packing under haunching against the sides of pipes after pipe laid and tested complete all as specified & as directed.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc
T/D old unserviceable submain wiring any size 4/6 Sq mm 02 run copper conductor single phase with earth wire including PVC conduit
M & L for concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) all as specified and directed by Engineer-in-Charge for the following :-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch same board.
All as per item No 118 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.
S&F socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed.
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed.
S&F for batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and as directed.
Supply & Fixing medium step type fan regulator 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed.
M & L for sub main wiring with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments incl PVC conduit medium grade 25 mm dia and PVC insulated copper conductor cable drawing in PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FRLS PVC insulated shall be measured and paid as one unit length.
Supply & Fixing SPN Distribution Box, double door of protection grade IP 42 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed. Make- Legrand cat no 507611 or eqvts of L&T/Schenider (Electric)
Supply & Fixing MCB SPN, 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand cat no 408618 to 408620 or eqvts of L&T/Schenider (Electric)
Supply & Fixing MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand cat no 408609 to 408617 or eqvts of L&T/Schenider (Electric)
Supply and fixing VTPN Distribution Box with MCCB Amp breaking capacity,16 KA double door of protection grade IP 42, in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed.
S&F Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed. Make- CG cat No LDL-20-CDL or equvts of Havells/Philips/Wipro
S&F Wall mounted Mirror light LED fitting, 10 Watt, 2 Feet long incl integrated electronic driver including dismantling taking down unsv sketch fitting any type complete all as specified and directed.Make- Crompton Cat No LDL-10-CDL or equvts of Havells/Philips/Wipro
S&F as in replacement Bulk Head fittings 12/15 watt on wall complete all as specified and directed by Engineer-in-charge.
S&F in replacement of old sketch fitting/any type by decorative wall mounted light with LED lamp (white/ warm) complete all as specified and directed.
S&F LED building security light 35 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed.
Supply only LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb.
Taking down existing ceiling fan serviceable type and deposite MES safe coustedy all as directed after complition of B/R work refixing of ceiling fan including fixing necessary arrangements complete all as specified and directed.
Taking down existing Exhaust fan serviceable type and deposite to MES for safe coustedy all as directed after complition of B/R work refixing of ceiling fan including fixing necessary arrangements complete all as specified and directed.
Supply & fix fans ceiling complete 230 V,1200 mm sweep. BEE rated including T/D old ceiling fan and deposit in MES store yard ,fixing arrangement and connection with 3 core flexible copper cable all as specifed and directed .
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep ,900 RPM with louver including cutting of hole of adequate size including making good existing surfaces incl fixing with MS fasnut all as specified and directed
Taking down Old unserviceable rusted earthing plates
supply and laying XLPE cable 50 x 3.5 core complete all as specified and directed by Engineer incharge
Excavation in trenches in Hard and dense soil n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of poles,cable laying etc, including forming bottom surface to required level and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soil/loose soil including spreading, leveling,watering & well ramming in layers not .exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches and punning down complete all as specified and directed by Engineer-in-Charge.
Material and labour cover to underground cable with one layer of bricks using sub class 'B' bricks laid flat acorss the cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 50 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Deduct Schedule of Credit of Rs. (-) 55832.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount Note: Tenderers will not quote against this item being a firm amount.
SHIVAE CONSTRUCTION (BID ID -3294714)
DAVINDER SINGH (BID ID -3295311)
M/S SANJAY STEEL WORKS (BID ID -3295113)
M/S SHUBAM ENGINEERS (BID ID -3295626)
MAHADEV ENTERPRISES (BID ID -3293654)
PARAS RAM ASGOTRA AND SONS (BID ID -3295386)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .