Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹49.7 L+₹44,962.10 (0.91%)Rejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L2 | Rejected-Finance Rejected being other than L1 |
Tender Value
Refer Docs
EMD Value
₹96,800
Closing Date
24 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 865 EWS
GE 865 EWS PIN-913865 c/o 56 APO
PROVN OF CERTAIN LBW WORKS OF AGE BR II AND AGE EM II UNDER GE 865 EWS
2021_MES_436053_3
865/EWS (NIT-08)/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per tender documents and as per policy in vogue
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹96,800
Yes
11 Aug 2021
9 Jul 2021
26 Jul 2021
9 Jul 2021
24 Jul 2021
9 Jul 2021
60 days
Amount
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for and removing debris outside the MoD land complete all as specified and as directed by Engr-in-Charge.
M&L for providing precast reinforced cement concrete type A1, 1:1.5:3 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes etc) and similar articles with plain faces and setting in cement mortar 1:6 complete with joints to match including use of necessary formwork all as specified and directed. Note : S&F reinforcement shall be measured and paid separately.
Reinforced cement concrete 1:1.5.3 type A1, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engineer-in-Charge. Note : Re-inforcement shall be measured and paid separately.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Formwork to edges of rough finished concrete flat surfaces, treads , breaks in floors, window cills concrete railing s openings in concrete walls , floors and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping andsimilar works exc 10 cm but n exc 20 cm wide complete all as specified and directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 06 to 08mm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Demolition of precast concrete block/Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for pre cast cement concrete block masonary of 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) with soild blocks, exc.10cm in width, set and jointed in cement mortor 1:6 complete all as spd and directed.
Walling of random rubble masonary, with best quality of locally available stones such as granite, trap or basalt stone, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed
Plain cement concrete 1:2:4 type B1 using (20mm graded crushed stone aggregates) in copings all as specified and directed including necessary use and waste of form work complete all as specified and directed.
Providing, cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates) in surface channels and drains complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick walls or on concrete surfaces plastered surfaces finished even and smooth without using extra cement, mixed with Water Proofing Admixture as per manufacturer's instructions complete all as specified and as directed (Water Proofing Admixture shall be measured and paid separately as supply only)
Supply only integral Water Proofing Admixture complete all as specified and directed. Make : Pidilite/Dr Fixit
Demolition cement concrete (unreinforced), in ground floors not exc. 15 cm thick, above or below ground level, and removing debris outside the MoD land complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in sub base, foundation, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M & L for joint free Non-Skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06sqm not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in Cement Mortar 1:4 for laying floor finishes complete all as specified and directed. MAKE: KAJARIA/H&R JOHNSON/CERA/ NITCO/SOMANY
M&L for (350mmx250mmx7mm/450mmx350mmx 7mm thick ) coloured glazed ceramic tiles set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments, incl 10mm thck screed bed below tile for dado/skirting CM 1:4 complete all as specified and directed MAKE: KAJARIA/H&R JOHNSON/CERA/ NITCO/SOMANY
Vitreous china water closet, 'Orissa' pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, incl bedding with PCC 1:2:4 type B-1 using 20 mm grade stone aggregate complete all as specified and as directed by Engr-in-Charge. Make: Cera/Hindware/Parryware
S&F Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed by Engr-in-Charge. Make: Cera/Hindware/Parryware
S&F Cast Iron 'P' or 'S' trap 100mm bore for Indian type water closet compele all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in hard/dense soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, exc 1.5 m wide and exc 1.5 mtr but n.exc 3 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in hard/dense soil and getting out soil, complete all as specified and as directed by Engineer-in-charge.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed and as directed by Engineer-in-Charge.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed and as directed by Engineer-in-Charge.
Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including the pipe inserted in Man holes walls etc. for undermentioned drain pipes, including removal of rubbish outside MoD land.
Demolition and breaking up 200mm dia drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including the pipe inserted in Man holes walls etc. for undermentioned drain pipes, including removal of rubbish outside MoD land.
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 150 mm bore pipes complete all as specified and directed.
Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 200 mm bore pipes complete all as specified and directed.
M&L for reinforced concrete pipes, class NP2, laid and jointed complete with collars for laying dia 150mm internal dia pipes of grade 'A' laid in trenches and jointed all as specified and directed.
M&L for reinforced concrete pipes, class NP2, laid and jointed complete with collars for laying dia 200mm internal dia pipes of grade 'A' laid in trenches and jointed all as specified and directed.
Destling/desludging/cleaning of man holes of any size n.exc 1.5 m in depth and removing all blockage from manhole such as plastic pieces, soil etc, removing waste material / sludge etc to a distance exc 100m outside the MoD land and burrying the same in pits in hygenic manners and covering the pits with excavated earth complete all as specified and directed by Engr-in-Charge. NOTE: The cost for excavation and earth work for pits is deemed to be included in the unit rate.
Destling/desludging/cleaning of man holes of any size exc 1.5 m and n.exc 3.00m in depth and removing all blockage from manhole such as plastic pieces, soil etc, removing waste material / sludge etc to a distance exc 100m outside the MoD land and burrying the same in pits in hygenic manners and covering the pits with excavated earth complete all as specified and directed by Engr-in-Charge. NOTE: The cost for excavation and earth work for pits is deemed to be included in the unit rate.
M&L for pumping and bailing out sludge and a like components from septic tanks, soakage pit and alike and removing waste material / sludge etc to a distance exc 100m outside the MoD land and burrying the same in pits in hygenic manners and covering the pits with excavated earth complete all as specified and directed by Engr-in-Charge. NOTE: The cost for excavation and earth work for pits is deemed to be included in the unit rate.
Dismantling posts or struts (wooden, steel or RCC) any section embadded in concrete, brick work etc including taking out embedded portion.
Dismantling chain link fencing wiremesh, any type complete all as specified and as directed by the Engr-in-charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 metre and making good the disturbed grouind, in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
M & L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete , complete all as specified and as directed.
S&F rolled tubular sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc and similar work conforming to Fe-290 Gde E-165 complete all as specifie dand directed by Engr-in-Charge.
M&L for two coats of synthetic enamel paint on new steel surfaces incl preparation of new steel surface over a coat of red oxide or zinc chrome primer complete all as specified and directed. MAKE : BERGER PAINTS/ASIAN PAINTS/NEROLAC PAINTS/ GOODLASS
Prepainted colored trapezoidal profiled Galvalume/ Zinc coated steel sheet with min 0.50mm TCT confirming to IS-513 (AZ-150 GSM, AL Zn alloy mettalic coating 550 MPA yield stress as per AS-1397), as in roof covering/cladding to wall fixed with self tapping screws colour/exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer, all fixed with Galvanised self drilling/self-tapping fastener (12-14 x 55 with EPDM seals) indlucing dismantling palin or corrugated sheeting any gauge thickness including nanital or similar pattern complete all as specified and directed by Engr-in-Charge. Make : Tata Blue Scope Steel Ltd/JSW Steel Ltd/CRIL
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:6), complete all as specified and directed by Engr-in-charge.
M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in CM 1:4 complete all as specified and as directed.
S&F galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised MS wire staple or steel pins etc as directed (each line wire to be measured.) complete all as specified and directed.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 Core, 70 Sqmm, conforming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified and directed by Engr-in-Charge. Make : Cable Corporation of India/Finolex Cable Co/Polycab/ Gloster/Havells/KEI/ RR Kabel Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 Core, 50 Sqmm, conforming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified and directed by Engr-in-Charge. Make : Cable Corporation of India/Finolex Cable Co/Polycab/ Gloster/Havells/KEI/ RR Kabel Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, punned to 18 cm thick complete all as specified in clause 19.75 of SSR Par-I, complete all as specified and directed by Engr-in-Charge. Note : Only punned thickness of 18 cm shall be measured and paid.
S&F of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-I flate size 250 x 150x40mm , complete all as specified and directed by Engr-in- Charge.
Sub main wiring with four runs of 10 Sqmm (4x10 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories etc with two run of 6 Sqmm (2x6sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, including cutting chases in wall for PVC conduit, sinking of MS boxes and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 4 runs of 10 Sqmm (4x10sqmm), 2 run of 6 Sqmm (2x6 sqmm) cable and one metre of conduit will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB Make of conduit: PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
Sub main wiring with two runs of 10Sqmm (2x10 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6Sqmm (1x6sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 10 Sqmm (2x10 sqmm), one run of 6Sqmm (1x6 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB Make of casing caping PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
Sub main wiring with two runs of 6 Sqmm (2x6 sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 4Sqmm (1x4sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6 Sqmm (2x6 sqmm), one run of 4 Sqmm (1x4 sqmm) cable and one metre of PVC casing caping will be measured as one unit. Make of Cable: L&T/FINOLEX/GRANDPLAY/ANCHOR/ POLYCAB Make of Casing Caping PLAZA/FINOLEX/ SUPREME/PRESTO PLAST
Supply and fixing MCB distribution board Double door, sheet metal box, TPN vertical load line DBs are fitted with 200 amps rated bus bars, neutal links, blanking plates (Without MCCB suitable for FP G frame), 415 volts 4 ways, concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc complete all as specified and as directed by Engr-in-Charge. Make: Cat part No 5077 45 of Legrand (Ekinoxe)/Cat Part No DHDLVDRWGOF004 of Havells or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Supply and fixing MCCB 4 pole 160 Amps, 10 KA, 415 Volt complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4200 17 of Legrand (DPX³)/Cat part No IHLGSF0160 of Havells or equal approved in Schneider (NSX)/Siemens (3VL2)/L&T (D-Shine)
Supply and fixing MCCB 4 pole 100 Amps, 10 KA, 415 Volt complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4200 15 of Legrand (DPX³)/Cat part No IHLGSF0100 of Havells or equal approved in Schneider (NSX)/Siemens (3VL2)/L&T (D-Shine)
Supply and fixing MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 12 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc. Make: Cat part No 5076 12 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Supply and fixing MCB distribution board Double door, regal grey, sheet metal enclosure, SPN 240 volts 8 way with 200 amps rated bus bar concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc. Make: Cat part No 5076 11 of Legrand (Ekinoxe) or equal approved in Schneider (Acti-9)/Siemens (Betagard-8GB32)
Supply and fixing MCB SPN 63 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4086 20 of Legrand (DX³)/Cat part No DHMGCSNF063 of Havells or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
Supply and fixing MCB SPN 40 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4086 18 of Legrand (DX³)/ Cat part No DHMGCSNF040 of Havells or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
Supply and fixing MCB SP 6 to 32 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4085 87 to 4085 95 of Legrand (DX³)/ Cat part No DHMGCSPF006-032 of Havells or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
Supply and fixing MCB SP 40 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4085 96 of Legrand (DX³)/ Cat part No DHMGCSPF040 of Havells or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
Supply and fixing MCB SP 63 Amps, 'C' series, 230 V A/C complete all as specified and as directed by Engineer-in-Charge. Make: Cat part No 4085 98 of Legrand (DX³)/Cat part No DHMGCSPF063 of Havells or equal approved in Schneider (Acti -9)/ Siemens (Betagard-5SL4)
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron 4 mm dia wire as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR (Part-I) complete all as specified and directed.
Supply and installation of 500 LPD evacuated collector based Solar Heating system with evcuated Tubes ALN-SS-CU (Three layers) 58-2100 - 35 Nos with suitable height of vent pipe with insulation (vent pipe measured seprately) including mild steel with PP coating angle iron of suitable size, suitable for fixing of solar water heater complete with all as speicified and directed by Engr-in-Charge. Make : V Gaurd/Supreme/TATA Power Solar System Ltd/Racold Note : (i) Angle iron frame for fixing of solar water heatng system shall be included in overall rates quoted against this item. (ii) Design and sections of steel members for frame shall be as per manufracturer's recommendations.
Rotational moulded polyethylene water storage PUF tank, PUF insulated with 100 mm thick PUF insulation of density not less than 48Kg/Cum, with aluminium cladding, inner and out white, two layers, ISI marked (cylinderical vertical/rectangular/loft type with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 4000 litres each including all accessories (i.e GI nipples, etc), including provn of 20/25mm dia spout for connecting inlet, outlet, overflow and washout pipes, complete all as specified and as directed by Engr-in-Charge. MAKE: SINTEX/POLYWELL/ROTEX/POLYCON Note : Frame of stand for mounting water tank shall be measured and paid separately as S&F under relevant item of this BOQ.
Mild steel framed work such as frame work for water tanks, cooler stand etc and similar work conforming to Fe-410-O or Fe-310-O, complete all as specified and as directed by Engr-in-Charge.
M&L for pre insulated 3 layers PP-R pipe, SDR 7.4 (PN-16) UV stabilised and antimicrobal fusion welded having thermal stability for hot & cold water supply including all PPR plain and brass threaded polypropylene random fittings including PUF insulation of thickness 75 mm glass/rock wool with chicken mesh, aluminium cladding complete suitable for above ground of size 25 mm dia all as specified and directed by Engr-in-Charge. Make : JINDAL/KISAN/SFMC/Supreme/Kanha Plastic Pvt Ltd
M&L for gun metal gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25mm pipe complete all as specified and directed by Engr-in-Charge.
M&L for pillar taps, cast copper alloy, with capaston heads chromium plated screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iorn pipe and fixed of size 25 mm complete all as specified and directed by Engr-in-Charge. Make : PARKO/MARC/ESS ESS/CERA
M/S BHAT ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .