Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.1 CrAccepted-AOC 143 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | ₹6.1 Cr Quoted ₹6.6 Cr | L-1 | Accepted-AOC ok |
| 2 | L-2₹6.6 Cr+₹3.3 L (0.50%)Rejected-Finance A 14 INDUSTRIAL HOUSE INDERPURI NEW DELHI 1100012 | NEW DELHI | NEW DELHI | DELHI | 110012 | ₹6.6 Cr+₹3.3 L (0.50%) | L-2 | Rejected-Finance Agreement made with L-1 agency |
| 3 | L-3₹6.8 Cr+₹24.1 L (3.68%)Rejected-Finance | ₹6.8 Cr+₹24.1 L (3.68%) | L-3 | Rejected-Finance Agreement made with L-1 agency |
| 4 | L-4₹6.8 Cr+₹27.5 L (4.20%)Rejected-Finance 46 LOWER GROUND FLOOR CHARMWOOD PLAZA EROS GARDEN FARIDABAD HARYANA 121009 | FARIDABAD | FARIDABAD | HARYANA | 121009 | ₹6.8 Cr+₹27.5 L (4.20%) | L-4 | Rejected-Finance Agreement made with L-1 agency |
| 5 | L-5₹7.0 Cr+₹42.7 L (6.51%)Rejected-Finance 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | ₹7.0 Cr+₹42.7 L (6.51%) | L-5 | Rejected-Finance Agreement made with L-1 agency |
Tender Value
Refer Docs
EMD Value
₹12.7 L
Closing Date
7 Aug 2023, 2:00 pmClosed
Executive Engineer, W.S. Mech. Division, Rewari
Executive Engineer, W.S. Mech. Division, Rewari
Supply, erection and commissioning of 03no 150 Cs (P1 P5 at JC1 and P2 at JC2) 02no 50 Cs (P9 JC1 and P7 JC2) 01no 12 Cs (P5 JC2) VT Pumps, 02no 600 HP HT (JC1 and JC2) 02no 40 HP LT (JC2) induction motors with LT Panel, cables, earthings at pump hou
2023_HRY_297111_5
1961/6-A dated 13.07.2023
Open Tender
Pumps/Motors
Works
240 days
Executive Engineer, W.S. Mech. Division
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,000
Yes
₹12.7 L
Yes
Executive Engineer, W.S. Mech. Division, Rewari
7 Nov 2023
15 Jul 2023
7 Aug 2023
15 Jul 2023
7 Aug 2023
15 Jul 2023
20 Jul 2023
Amount
Supply, Erection & Commissioning of 150Cs Y-body type VT axial flow pump (P1 JC1) having lift approx 20ft , 495 RPM including MS Delivery Pipe (10mm thickness), Syphon Bend (10mm thickness), Support of syphon bend and any left over item as per site requirement, all bolts (HS). Specifications as approved by technical committee (Annexure - A).
Supply, Erection & Commissioning of 150Cs Y-body type VT axial flow pump (P5 JC1 & P2 JC2) having lift approx 20ft , 495 RPM including MS Delivery Pipe (10mm thickness) and any left over item as per site requirement, all bolts (HS). Specifications as approved by technical committee (Annexure - A).
Supply, Erection & Commissioning of 50Cs Y-body type VT axial flow pump (P9 JC1 & P7 JC2) having lift approx 20ft , 735 RPM including MS Delivery Pipe (10mm thickness), Syphon Bend (10mm thickness), Support of syphon bend and any left over item as per site requirement, all bolts (HS). Specifications as approved by technical committee (Annexure - A). Motor stool and pump coupling should be as per existing Marathon (150KW) motor at site.
Supply, Erection & Commissioning of 12Cs Y-body type VT axial flow pump (P5 JC2) having lift approx 12ft , 1465 RPM including MS Delivery Pipe (08mm thickness), Syphon Bend (08mm thickness) and any left over item as per site requirement, all bolts (HS). Specifications as approved by technical committee (Annexure - A).
Supply, erection and commissioning of induction motor of 600HP suitable for above supplied 150Cs VT axial flow pump (JC1 & JC2), 450KW, 495RPM, 3.3KV, 3 phase, 50 Hz, bearings (SKF /FAG) as per site requirements. Specifications as approved by technical committee (Annexure - B).
Supply, erection and commissioning of induction motor of 40HP LT suitable for above supplied 12Cs VT axial flow pump (P5) and existing pump (P3), 30KW, 1465RPM, 415V, 3 phase, 50 Hz, bearings (SKF /FAG) as per site requirements. Specifications as approved by technical committee (Annexure - B).
Supplying and laying of 630 sqmm - single core, 3.3KV, HT, Aluminium Conductor, XLPE insulated unearthed, Armored cable as per latest IS specifications with cable box (all accessories) from DHBVN Sub Station to VCB at pump house (250mtr at JC1 and 360mtr at JC2).
Supplying and laying of 240 sqmm - 3.5 core, 415V, LT, Aluminium Conductor, XLPE insulated, Armored cable as per latest IS specifications with thimbles/clamps/terminals (all accessories) from DHBVN Sub Station to LT MCC panel in Pump house (60mtr at JC1 and 100mtr at JC2).
Supplying and laying of 16 sqmm - 3 core, 415V, LT, Copper Conductor, XLPE insulated, Armored cable as per latest IS specifications with thimbles/clamps/terminals (all accessories) from LT panel to motors of Bhurthal Disty in Pump house.
Providing and fixing of foundation for 150 Cs VT pump by making required size/length at site from ISMB of size 500x200mm - approx 4600 mm length - 02 nos (Make - Tata/ Jindal/Sail/Vaizag). One end of this ISMB sections shall be grouted into the wall by making arrangement of PCC block of suitable size as per the weight of Pump. While other end should be welded/bolted to the existing ISMB 600x210mm with the help of L- bracket and nut/bolts/washers. Including material and labour for applying primer and two coats of epoxy paint on the complete foundation and labour charges for taking out old rusted foundation (P1 P5 at JC1 & P2 at JC2).
Providing and fixing of foundation for 50Cs VT pump by making required size/length at site from ISMB of size 450x150mm - approx 4600 mm length - 02 nos (Make - Tata/ Jindal/Sail/Vaizag). One end of this ISMB sections shall be grouted into the wall by making arrangement of PCC block of suitable size as per the weight of Pump. While other end should be welded/bolted to the existing ISMB 600x210mm with the help of L- bracket and nut/bolts/washers. Including material and labour for applying primer and two coats of epoxy paint on the complete foundation and labour charges for taking out old rusted foundation (P6 P7 P8 JC2).
Providing and fixing of chemical earthing by digging suitable bore and depth pit suitable for 3.3KV incoming complete with copper electrode, copper strip for all 03no VCB panels complete in all respect as per site requirement at pump house JC1 & JC2.
Providing and fixing of Lightening Arrester with protection radius of 100mtr along with earthing arrangement as per proper specification for pump house building and as per the site requirement at pump house JC1 & JC2.
Overhauling of MV feeder piller VCB of 3.3KV - Tosha make (01no incomer and 03no outgoings) by replacing IDMT relay,all the motor protection relays, transformers ckt 220/110, Ammeters, voltmeters, close coils, trip coils, spring charge motors, control wirings, panel locks glasses hinges and other unforseen items/repairs required for its proper functioning/operation complete in all respect as per site requirement. All the components as per approved specification of deptt (Annexure-C) at pump house JC1 & JC2.
Providing and fixing of chemical earthing by digging suitable bore and depth pit for LT Panels complete with copper electrode, copper strip for Bhurthal panel complete in all respect as per site requirement
The above rates are inclusive of all kind of taxes including GST and other expences like F.O.R. destination and inclusive of all incidental charges, enroute & at destination. Nothing extra shall be paid separately. Terms & Conditions as mentioned in Bid document in Price Schedule.
MOHINI ELECTRICALS LTD.
Sahil Engg. Works
ace marketing pvt ltd
M/s KRP Engineering Pvt. Ltd.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .