Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹38.5 L+₹6.6 L (20.7%)Rejected-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹39.4 L+₹7.6 L (23.7%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹41.2 L+₹9.4 L (29.5%)Rejected-AOC NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹41.6 L+₹9.8 L (30.6%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
24 Jun 2022, 6:00 pmClosed
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
GE S U 11 2022 23 DAY TO DAY MAINTENANCE OF INTERNAL ELECTRIFICATION AT CERTAIN LOCATIONS AND REPAIR MAINTENANCE OF CERTAIN PARTS OF CEILING FANS EXHAUST FANS CABIN FANS AND ALLIED WORKS UNDER AGE EM OF GE SOUTH UDHAMPUR
2022_MES_526775_1
GE/S(U)-11/2022-23
Open Tender
Civil Works
Works
330 days
GE SOUTH UDHAMPUR
As per NIT documents
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹91,000
6 Aug 2022
27 May 2022
25 Jun 2022
27 May 2022
24 Jun 2022
10 Jun 2022
27 May 2022 - 6 Jun 2022
Amount
Repairing of unserviceable light point, Fan point, socket point 5A/15A, switches, sockets or regulator, light fixtures any type , any type MCBs, DB's & all electrical accessories in day to day/door to door maintenance and making it serviceable in all respect with all replacement of any major part but including small length of wires upto 2.5 sqmm single core (not more than 50 cm), adhesive tape and other connected accessories like screws & washers etc. Work shall also include to check & removal of breakages in service connection /sub main of houses as and when directed. The scope of work shall also include cutting of existing Bakelite sheet to accommodate new wiring accessories like switches, sockets, fan regulators etc complete all as specified and as directed.
Note:- (a) Contractors representative/engineer will report to JE E/M / Engr-in-charge daily at forenoon and afternoon to collect routine/urgent works related to internal electric supply till completion of contract. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job including every type of requisite T&P items to his trades man. All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(b) The penalty shall be applicable to the contractor if the delay is noticed by the EIC more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-In-Charge/ JE E/M shall handover the slip containing specification of work to the contractor. The contractor shall attend the job immediately and report to Engr-In-Charge within 12hrs. The contractor will keep his tradesmen in stand by for attending any routine/urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 20 per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW –2249 and shall be treated as interim condition of the contract and shall enforceable as and delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regard shall be final and binding.
(c ) One Complaints slip to be treated as One Complaint irrespective of No. of Repairs mentioned in the same.
(d) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours ( 0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs ) Other than the Regular complaints during working Hrs ( 0900 Hrs to 1700 Hrs )
(e) Procurement of Security gate passes of the Electrician , will be sole responsibility of the Contractor
(f) If the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the govt.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket, fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and as directed.
Taking down Old/ Unserviceable MCCB/MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and as directed. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per srl item No 5 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 Sqmm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 5 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 Sqmm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 5 but for One light point controlled by two 2-way switches,with cables 1.5 Sqmm size complete all as specified and as directed.
All as per Srl item No 5 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and as directed.
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and as directed.
S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and as directed.
S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in Wiring with Copper conductor cables in PVC casing & caping as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with sunken boxes & PVC back plate for mounting all type switches, sockets & regulators etc with front plate including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and as directed. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per srl item No 14 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 Sqmm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 14 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 Sqmm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 14 but for One light point controlled by two 2-way switches, with cables 1.5 Sqmm size complete all as specified and as directed.
All as per Srl item No 16 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 Sqmm earth wire standard and connected to earth dolly complete all as specified and as directed.
Switch piano 5 Amps single pole one way 230 V, 50 Hz, AC complete all as specified and as directed.
Switch piano 15 Amps single pole one way 230 V, 50 Hz, AC complete all as specified and as directed.
Socket outlet 2 in 1, 3 pin, 5A, 230 V, 50 Hz, AC complete all as specified and as directed.
Socket outlet 2 in 1, 3 pin, 15A, 230 V, 50 Hz, AC complete all as specified and as directed.
Bell push flush type 5 amp 230 V, 50 Hz, AC complete all as specified and as directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete all as specified and as directed.
Calling Bell ding dong 230 volts single pole 50Hz complete all as specified and as directed.
Electronic fan regulator stepped type 120 watt 230 volts 50Hz two module C/S deluxe type complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 10 Sqmm in PVC concealed conduit /casing capping 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead all as specified. Including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit /casing capping 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead complete all as specified and as directed. Including taking down old sub main wire.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in PVC concealed conduit/casing capping 25mm dia including PVC insulated copper conductor cable 4 Sq mm as earth lead including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2.5 Sqmm in PVC concealed conduit/casing capping 25mm dia including PVC insulated copper conductor cable 1.5 Sq mm as earth lead including taking down old sub main wire complete all as specified and as directed.
Sheet metal enclosure double door type for MCCB TPN DB upto 125 Amps, 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link including MCCB 125 Amps 25 KA , chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
Sheet metal enclosure double door type for MCB TPN DB upto 6 way vertical type 415 volts with 400 Amps rated busbar and neutral link including MCB upto TPN 100 Amps 10 KA , chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
Sheet metal enclosure double door type for MCB TPN DB upto 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link , chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
Sheet metal enclosure double door type for DBs (when MCB to be used) Single pole & neutral 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
Sheet metal enclosure double door type for DBs (when MCB to be used) Single pole & neutral 8 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
Sheet metal enclosure double door type for DBs (when MCB to be used) Single pole & neutral 4 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S & F in replacement MCCB Three Pole & Neutral capacity of 125 amps 415 volts rupturing capacity 16 KA complete all as specified and as directed.
S & F in replacement MCB Single pole and neutral 240 volt any rating from 40 Amps"C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB single pole 240 volt any rating from 10 to 40 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB single pole and neutral 240 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB TPN 415 volt any rating from 40 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB TPN 415 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB TPN 415 volt any rating from 100 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps nicluding taking down of old one complete all as specified and as directed.
S & F in repairs modular switch one way 230 volt 50 Hz , 6A, 1 module complete all as specified and as directed.
S & F in repairs modular switch one way 230 volt 50 Hz , 16A, 1 module complete all as specified and as directed.
S & F in repairs modular bell push one way 230 volt 50 Hz , 6A, 1 module complete all as specified and as directed.
S & F in repairs modular socket outlet 6A 2/3 pin combined 2 module complete all as specified and as directed.
S & F in repairs modular socket outlet 6A/16A 2/3 pin combined 2 module complete all as specified and as directed.
S & F in repairs modular fan regulator 120W 2 module complete all as specified and as directed.
S&F in repairs piano switch 5 Amps single pole one way 230 V, 50 Hz, AC , complete all as specified and as directed.
S&F in repairs piano switch 15 Amps single pole one way 230 V, 50 Hz, AC , complete all as specified and as directed.
S&F in repairs bell push single pole one way 230 V, 50 Hz, AC complete all as specified and as directed.
S&F in repairs for Socket outlet 2 in 1, 3 pin, 5A, flush type 230 V, 50 Hz, AC , complete all as specified and as directed.
S&F in repairs for Socket outlet 2 in 1, 3 pin, 5/15A, flush type 230 V, 50 Hz, AC , complete all as specified and as directed.
S & F in repairs buzzer ding dong AC 230 volts single pole complete all as specified and as directed.
S&F in repairs for switch Socket combination 2 in 1, 5 pin, 5A, flush type 230 V, 50 Hz, AC complete all as specified and as directed.
S&F in repairs for switch Socket combination 2 in 1, 5 pin, 5A,/15 flush type 230 V, 50 Hz, AC complete all as specified and as directed.
S&F in repairs for modular switch Socket combination 2 in 1, 5 pin, 6A, 230 V, 50 Hz, AC complete all as specified and as directed.
S&F in repairs for modular switch Socket combination 2 in 1, 5 pin, 6A/16A, 230 V, 50 Hz, AC complete all as specified and as directed.
S & F in repairs Angular Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for light fittings complete all as specified and as directed.
S & F in repairs electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc complete all as specified and as directed.
S & F in repairs LED lamp white/ warm white 5/7/9 W Base CapB 22/E27 with all necessary fixing arrangement complete all as specified and as directed.
S & F in repairs LED lamp white/ warm white 15 W Base Cap B 22/E27 03 star rated with all necessary fixing arrangement complete all as specified and as directed.
S & F in repairs thread type 5/12/20 watt white/ warm white Base 2 Cap B 22/E27 light fitting 6500K /2700K(White/yellow) with all necessary fixing arrengement complete all as specified and as directed.
S & F in repairs LED lamp 0.5 Watt Safelite white/ warm white Yellow/Green/Red Base Cap B22 for engagement lights with all necessary fixing arrengement complete all as specified and as directed.
PVC insulated (unsheathed) 03 core multistranded cable copper conductor FRLS suitable upto 1.5 Sqmm suitable upto 1100volts complete all as specified and as directed.
PVC insulated (unsheathed) 03 core multistranded cable copper conductor FRLS suitable upto 2.5 Sqmm suitable upto 1100 volts complete all as specified and as directed.
PVC insulated (unsheathed) single core multistranded cable copper conductor FRLS suitable upto 1.5 Sqmm suitable upto 1100 volts complete all as specified and as directed.
PVC insulated (unsheathed) single core multistranded cable copper conductor FRLS suitable upto 2.5 Sqmm suitable upto 1100 volts complete all as specified and as directed.
S & F in repairs Electronic LED panel driver/ adoptor with universal connector for easy installations to light fittings suitable for 36/40W, 230 Volt ,AC complete all as specified and as directed.
S & F in repairs Electronic LED panel driver/ adoptor with universal connector for easy installations to light fittings suitable for 3W, 230 Volt, AC complete all as specified and as directed.
S & F in repairs Electronic LED panel driver/ adoptor with universal connector for easy installations to light fittings suitable for 8W, 230 Volt, AC complete all as specified and as directed.
S & F in repairs Electronic LED panel driver/ adoptor with universal connector for easy installations to light fittings suitable for 15/18/24W, 230 Volt ,AC complete all as specified and as directed.
S & F in repairs PVC Casing Caping of Size upto 25 mm and 12 mm including all connected accessories (Like - Nail, Tee, Albow etc) complete all as specified and as directed.
S & F in repairs PVC Conduit of Size 20/25 mm including all accessories (Like - Nail, Clamps, Albow etc).complete all as specified and as directed.
M&L for PVC Flexible twisted cable twin core copper conductor cable of size 23/0.0076 complete all as specified and as directed.
S & F in repairs fan Capacitor 2.5/3.15mfd AC, 230 volt complete all as specified and as directed. Make : Havells/ Radson/ Epcos
S & F in repairs LED lights fitting 1x 5W, 230V, white/ warm white AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F in repairs LED lights fitting 1x 10W, 230V,AC white/ warm white decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F in repairs LED lights fitting 1x 20W, 230V,AC white/ warm white decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F in repairs LED light fitting 1x9W/1X10Wbulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED building security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S & F in repairs LED wall mounting mirror type white/ warm white pitcture light fitting with high out put diffuser 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED decorative down light fitting/recess mounted round type white/ warm white with high out put diffuser 8 watt 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED decorative down light fitting/recess mounted round type white/ warm white with high out put diffuser 12 watt 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED decorative surface mounted light fitting round/square type white/ warm white with high out put diffuser 18 watt 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED panel decorative down light fitting/recess mounted square type white/ warm white 2X2 36W with high out put diffuser 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED panel decorative surface mounted square type white/ warm white 2X2 36W with high out put diffuser 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED wall mounting Decorative wall light fixture CITY 3 made up of Polycarbonate, suitable for 9 W retrofit LED Lamp B 22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED wall mounting Decorative wall light fixture Apple made up of Polycarbonate, suitable for 9 W retrofit LED Lamp B 22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED Decorative, STYLO wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LE D lamp B 22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs metal clad plug and socket for AC plug and geysers complete all as specified and as directed.
S&F Street light Bracket complete made of GI pipe of suitable size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall complete all as specified and as directed.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and as directed.
Supply and fixing mini calling bell indicator with light 10 way controller box for offices in VIP bldgs complete all as specified and as directed.
Switch - socket combination 5 Amps, 5 pin multipurpose with PVC Box, 4 holes complete all as specified and as directed.
Switch - socket combination 15 Amps, 6 pin multipurpose with PVC Box, 4 Holes complete all as specified and as directed.
Taking up/down carefully ceiling fans 1200/1400 mm sweep and exhaust fan/pedestal/air circulator Fan/ wall mounted fan any size, any sweep, from various bldgs (Or collecting from MES E/M Store Yard) as directed, opening up for servicing/repairaing , removing dust and dirt ,cleaning fan motor with cotton/waste malmal, washing blades with detergent powder, servicing/Oiling , Lathe work if any required and greasing of fan of any size/type by using approprite grade of oil/grease and Replacing defective parts such as armature, conopy, Fan blade, Ball bearing, Fan down rod, shutter/louvers , MS shaft, bush, bearing split pin, rubber bush , holding clamp, capacitor ,MS clamps, rubber packing, split pins rubber reel etc, for the smooth and satisfactory functioning, and reassembling complete, re-fixing ceiling fan /exhaust fan with proper PVC flexible pipe 20 mm dia, in same position ( or deposited to MES Store Yard ) , connecting to copper flexible cable 40/.0076 size to electrical system and including proper testing complete all as specified and as directed.
Note: (a). Replacement of unserviceable parts shall be measured and paid for separately under respective items as Supply Only.
(b) On testing after completion of repair , if the proper speed/smootheness is not obtained at Engr-in- charge satisfactory level , the reapiring will be re- done by the contractor at his own costs and the same shall be deemed to be included in the quoted rates.
(c) The contractor shall maintain/open a Workshop and keep his electrician ready during working Hrs ( 0900 Hrs to 1700 Hrs ) for repair/rewinding pupose, inside MES store Yard so that all the repairing/ rewinding of Fans will be done in proper manner, MES authorities will not be issued any Fans ,any type, for repaire/rewinding puropse to the contractor for his outside workshop.
Rewinding & Painting (painting with two coats of synthetic asian paints) of AC ceiling fan motor 240 volt, 50 Hz, 1200 mm sweep of any make with super enameled copper winding wire of existing size including sleeve work, varnishing with ‘B’ class insulation varnish, connection with flexible copper wire 0.472mm dia upto connector block, complete all as specified and as directed. (Motor shall be wound with machine with same No of turns as per existing.)
All as per srl item no 100 here-in before but Ceiling Fans of 1400 mm sweep complete all as specified and as directed.
Rewinding & Painting (painting with two coats of synthetic asian paints) of exhaust fan motor 240 volt, 50 Hz, 300/380 mm sweep of any make with super enameled copper winding wire of existing size including sleeve work, varnishing with ‘B’ class insulation varnish, connection with flexible copper wire 40/.0076mm dia upto connector block complete all as specified and as directed. (Motor shall be wound with machine with same No of turns as per existing.)
All as per srl item no 102 here-in before but exhaust fans/ wall mounting fan of 450 mm sweep complete all as specified and as directed.
Supply only Capacitor AC 415 volts 2.5 mfd 50 HZ complete all as specified and as directed.
All as per srl item No 104 here-in-before but 3.15 to mfd complete all as specified and as directed.
Supply only MS shaft for exhaust fan 300 mm to 450 mm size complete all as specified and as directed.
Supply only bearing ball suitable for ceiling fan for 1200 mm sweep complete all as specified and as directed. Make SKF/NBC
Supply only bearing ball suitable for ceiling fan for 1400 mm sweep complete all as specified and as directed. Make SKF/NBC
Supply only bearing ball suitable for exhaust fan /pedestal fan/air circulator/table fan complete all as specified and as directed. Make SKF/NBC
Supply only blade set MS fan suitable for Steel body exhaust fan of 300mm sweep as required, complete all as specified and as directed.
Supply only fan blade set heavy duty suitable for PVC/steel exhaust fan/pedestal/air circulator fan upto 430 mm sweep as required complete all as specified and as directed.
Supply only ceiling fan blade set 1200 mm sweep complete all as specified and as directed.
Supply only ceiling fan blade set 1400 mm sweep complete all as specified and as directed.
Supply only down rod 30 cm long of ceiling fan 1200/1400mm sweep including clamps, reels lock nuts, split pin etc complete of standard size complete all as specified and as directed.
Supply only PVC insulated twin core twisted copper flexible cable of size 23/0.0076 from connector block to ceiling rose and making connection complete all as specified and as directed.
Fan regulator stepped type electronic fan regulator flush type on the existing laminated sheet complete all as specified and as directed.
Supply only upper / lower canopy for 1200/1400 mm sweep ceiling fans of complete all as specified and as directed. Make -:Usha/Orient/Polar/Khaitan.
Shutter / louver of MS sheet for of size 300 to 450 mm sweep for exhaust fan with fixing arrangement complete all as specified and as directed.
Supply only armature for celling fan suitable for 1200mm sweep with prewired copper wound armature complete all as specified and as directed.
Supply only armature for celling fan suitable for 1400mm sweep with prewired copper wound armature complete all as specified and as directed.
Supply only holding clamp for capacitor of ceiling Fans 1200/1400 mm sweep complete all as specified and as directed.
Supply only MS Clamps for hanging purpose of ceiling fan with proper rubber reel packing complete all as specified and as directed.
Supply only ceiling fans, MS shaft of standard size 1200 mm to 1400 mm size complete all as specified and as directed.
Note : Bidders attention is invited to pages on ser page No 13 & 14 of tender documents.
DEV RAJ MAGOTRA
ARNABH ASSOCIATES
CITY TOP ELECTRICAL WORKS
G R CONSTRUCTIONS
m/s shanti trading company
Bansal and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .