Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.9 L+₹52,466 (3.42%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other then lowest | |
| 3 | L3₹15.9 L+₹53,662 (3.50%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L3 | Rejected-Finance Other then lowest | |
| 4 | L4₹17.0 L+₹1.6 L (10.6%)Rejected-Finance | L4 | Rejected-Finance Other then lowest | |
| 5 | L5₹43.2 L+₹27.9 L (181.6%)Rejected-Finance | L5 | Rejected-Finance Other then lowest |
Tender Value
₹2.3 L
EMD Value
₹46,000
Closing Date
14 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)-143530
GE GSR- 31/ 2021-2022 CERTAIN REPAIR/ REPLACEMENT TO AREA LIGHTING AND PERIMETER LIGHTS AT ZONE-II OF TIBRI MIL STN UNDER GE GURDASPUR
2021_MES_489905_2
GE GSR-31/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE Gurdaspur (Tibri)
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹46,000
Yes
5 Apr 2022
22 Feb 2022
21 Mar 2022
22 Feb 2022
14 Mar 2022
2 Mar 2022
60 days
Amount
M & L for dismantling/taking down carefully Street light fittings of any type HPSV, HPMV, any wattage of flood lights, post top lanterns etc. by disconnecting of electric connection from pole / walls of any heights and any situation/ location, place complete all as specified and directed by Engineer-in-Charge.
Supply & fixing LED Street light 90 Watt WARM WHITE 4000K with silicon gasket for IP 66 (no glue) protection suitable upto 50mm OD holder fixed on existing poles. LED street light shall be made up of pressure die cast alluminium LM 6 aloy housing with toughened glass and high power LEDs and secondary lenses with IP 66 protections ( of any one of maufacturers of LED viz; Nichia, Cree, OSRAM, Philips), top opening for separate driver compartment with frame, brand, logo embossed, toughened glass cover. High power ceramic base, CRI > 70 and bolted inside the luminaire panel. Average life class of 50000 hrs metal body fully coated phase to phase protection at 440 V upto 4 hours and > 300 V auto cut and restart feature. Luminaries and driver shall be of same make to avoid any dispute and service issue later all as specified and directed. Note :- LM 79 test report, LM 80 report with minimum 9000 hrs testing to support 50K life TTC and dirver NABL accreditated report shall be submitted before execution of work to the Engineer - in - Charge .
All as per Srl item No 3 above but 72 Watt all as directed by Engineer-in-Charge
All as per Srl item No 3 above but 60 Watt all as directed by Engineer-in-Charge
Supply and fixing in replacement LED flood light 200 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driver and lamp in replacement metal halide flood light hoarding light luminaire complete accessories, connecting up with twin core twisted flexible copper conductor cable. Flood light shall be made up of pressure die cast aluminum LM6 alloy housing with toughened glass and high power LEDs and secondary lenses with IP66 protection complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 6 above but 120 Watt all as directed by Engineer-in-Charge
Supply and fixing of 45 watt LED Inverter street light with suporting AUTO ON/ AUTO OFF and must have DIMMING facility from 10 to 100% of rated wattage as per user defined timeline. Housing made of pressure die cast aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, have secondary lens for better optics, should have LM80 certified LED of CREE, NICHIA, OSRAM, SEOUL make only electronic driver with 5KV SPD , IP66. Street light shall have inbuilt Li-ion battery of 5200mAH and shall have > 1.5hrs battery backup at inverter load in case of power failure, efficacy > 100LPW, CRI >70, THD < 10%, PF > 0.95, cut off voltage at 300 volt + 10% and suitable for 50mm mounting pipe all as per Halonix Model : HLSLD-ML04-45-CWL-INV-R or equivalent as approved by GE". Note :- Before placing the order contractor must get approved TD and sample from GE.
All as per Srl item No 8 above but 60 Watt all as directed by Engineer-in-Charge
Supply and fixing in replacement of UNSV driver for LED Street light fitting driver for LED street light/ Flood light/ Post top lantern capacity 150 to 200 Watt for any make and type complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 10 above but 90 to 120 Watt all as directed by Engineer-in-Charge
All as per Srl item No 10 above but 70 to 72 Watt all as directed by Engineer-in-Charge
All as per Srl item No 10 above but 30 to 60 Watt all as directed by Engineer-in-Charge
Supply and fixing in replacement GI pipe bracket made out of GI pipe light grade 32mm dia and bend to shape 1.5 mtr long, including MS clamps made out of MS flat iron of size 40X4mm thick with nuts & bolts, washers complete including dismantling the existing GI pipe bracket and drilling of holes for nuts & bolts etc all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of three phase 8 KW automatic street light control switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation should be based on Natural Light Lux level. Switching off illuminance level should be of minimum 30 Lux and Switching off illuminance should be greater than or equal to 10 LUX. The sensor should also have part night operation facility of min 4 hrs to maximum 12 hrs. The circuit shall have a provision for manual over ride operation. The sensor along with suitable power contactors and incoming-outgoing MCBs should be enclosed in a pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP 54 complete all as directed by Engr-in-Charge. The Make of Nature switch : Kakatiya Energy Systems/Havells/Healer, Contactor: BCH/ L&T/ Schneider, MCBs : Hager/ Schneider/ L&T/ C&S, SMC enclosure and circuit sheet: Sintex/Hensel
Repair / tightening of end terminals of street light fitting , flood light, Post top lanten of any size/ capacity at any height and repair the street lights, flood lights and post top lanten having minor faults i.e loose connections, carbon deposition, shifting and refixing the same etc and make the light functional all as specified and directed by Engineer-in-Charge. Note :- (a) Complaint shall be rectified within 48Hrs time frame after intimation to the contractor/ contractor rep by telephonically/ whatsapp msg or letter by JE/Engineer-In- Charge, failing which penalty of Rs 100 per day per complaint will be levied on contractor. (b) One supervisor of Contractor will report to JE E/M/ Engr-in-charge on daily basis with complaint register.
M & L for repair of the panel timer switch of street lights including replacement of the following defective parts/ items complete all as specified and directed:- (a) Lugs (b) Copper/ aluminium wire (c) Welding/ brazing and painting of one coat of paint. Note :- Cost of relevant pars not paid separately.
Supply and fixing in replacement digital type timer switch front mounted programmable per 1 min current capacity 15-16 amps with 1 change over, total 25 programes complete all as specified and directed.
Supply and fixing in replacement of 3 pole power contactor of amp rating 45 to 60Amp as per existing make and rating all as directed by Engineer- in-charge.
Supply and fixing of LED post top lantern with die cast housing cum heat sink with PMMA diffuser in IP-66 fitting of 40 Watt complete complete all as specified and directed by Engineer-in-Charge.
Supply and laying weather proof flat twin core cable aluminium conductor 1100 volts grade size 10 Sqmm including taking out old one all as specified and directed.
Supply and fixing in replacement aluminium lugs eye type suitable for cable size 6 sqmm to 10 including necessary crimping with crimping tool complete all as specified and directed.
All as per Srl item No 23 above but size 16 sqmm to 35 sqmm.
Supply and fix LT straight through cable joining kit heat shrinkabale complete with jointing materials suitable for LT armoured cable 2/4 core of size 6 sqmm to 16 sqmm complete all as specified and directed.
Supply and fix LT straight through cable joining kit heat shrinkabale complete with jointing materials suitable for LT armoured cable 3.5/4 core of size 25 sqmm to 50 sqmm complete all as specified and directed.
Supply and fixing in replacement PVC cable copper conductor of size 1.5 sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
S & F in replacement junction box poly corbonate size 250x200x100mm with glass fibre reinforced, environment friendly, recylable, UV resistant, halogen and silicon free anti acid and anti corrosive IP 66 /67 in accordance with IE rule internally embedded gasket, junction box including 3 phase 415 volt aluminium bus bar and Din rail for fixing the MCB including one No. MCB SP 6A 10KA to control the street light including clamps, nuts bolts to fix the junction box with poles all specified and directed.
M & L for preparation of old painted surfaces of electric pole removing complete dust and other deposited materials by cleaning from steel tubular pole of length upto 9 metres cross arms, bracing, clamps etc and painting with one coat of aluminium paint, retaining and repainting existing marking on poles and replacement of reflective band of 3M brand RED-YELLOW-RED alternate coloured 3 numbers of minimum 5 cm in height wrapped all around the pole all as specified and directed by Engineer-in-Charge.
Re-Stringing of existing ACSR conductor of any size any type as required sag fixed on OH line incl unwindinding the conductor & insulators/cross Arms on poles properly binding with alumminum all as specified and directed.
M & L in replacement for aluminium conductor steel reinforced (ACSR) over size of ferret/ weasels/ mink/ beaver etc fixing stretching and jumppering joining with aluminium wire complete all as specified.
Supply and fixing in replacement shackle type insulator porcelain vitrous white, brown or green insulator incl galvanised mild steel straps washers insulators bolts washers of size 75x90 mm all as specified and directed.
Excavation in trenches in soft loose soil n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for poles, stay, cable, pipe etc including taking out brick protection and sand cushioning, getting out complete all as specified and directed.
Returning , filling in, including spreading, leveling , watering and well ramming in layers each n. exc 25cm thick in soft loose soil complete all as specified and directed.
Removing of excavated material (soil) to distance not exc. 50metres and deposited where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed.
Supply and lay brick common burnt sub class "B" old size for protection of cable laid in trenches for under ground cable all as specified and directed.
M&L for sand cushioning trenches using fine sand to under ground cable, laid in two layer 15cm before laying the cable and 8 cm after laying the cable complete all as specified and directed.
M&L for road cutting, including excavation returning filling in, spreading levelling, well ramming in layers, soiling with, broken boudders/ stones, WBH 7.5 cm thick coarse aggregate received from dismentling the existing road, premix , carpeting 25mm thick using ready mate material , rolled and compacted for road patch repair work. (Section/ cross section area of cutting shall be as specified and as directed by Engineer-in-Chagre).
Supply and laying in replecement XLPE insulated armoured (under ground) heavy duty electric cable with stranded aluminium conductor 1100 volts grade of crossectional area 25 sqmm 4 core laid in trenches/ ducts/ through pipes/ in floor road/ along the pole etc complete all as specified and directed.
Supply and laying in replecement XLPE insulated armoured (under ground) heavy duty electric cable with stranded aluminium conductor 1100 volts grade of crossectional area 16 sqmm 4 core laid in trenches/ ducts/ through pipes/ in floor road/ along the pole etc complete all as specified and directed.
M&L for cross arms in replacement, bracing, supports, clamps and back plates, fabricated from structural steel section including nut bolts washers including welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed including two coats of aluminium paint over a coat of red oxide complete all as specified and directed.
Supply and fixing in repair of motion sensor based LED street light of capacity 45 watt IP-66 rated voltabe and frequency 240V, 50 Hz AC, 5700K with aluminum pressure die cast housing toughened glass in the front and peanut lens for batwing light distribution to ensure uniform light distribution, higher spacing between poles and motion sensor all as Orient cat part No LSFT-045-C-FO-us or equivalent makes as per Appx 'B'. Note :- Before placing the order contractor must take approval of TD & make and sample from GE. LED :- LM 80 certified LED. Lens - Batwing 135/85 Degree. Motion Sensor ; Available, Normal range upto 5-7 metre. Hardware :- SS or Ms zinc plated & passivated . Lumens maintenance :- 50000 Hrs @ L70 for LED.
Note: A Schedule of Credit for old/unserviceable demolished/dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
kailu construction co
HARPAL ENGINEERS AND BUILDERS
Sharma Electrical and Engineering Works
RATTAN CHAND CHANDAN AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .