Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC | ₹11.6 L Quoted ₹9.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹9.7 L+₹926.85 (0.10%)Rejected-Finance | ₹9.7 L+₹926.85 (0.10%) | L2 | Rejected-Finance L2 |
Tender Value
₹9.3 L
EMD Value
₹18,537
Closing Date
16 Jan 2026, 5:00 pmClosed
EXECUTIVE ENGINEER, DIVN V, BICHOILM.
O/O EXECUTIVE ENGINEER, DIVN V, BICHOLIM.
Tender for the work of Shifting of 200 KVA DTC of Rumad Velguem to a new location at the load Centre in the jurisdiction of S.O Pale under SD II Sakhali.
2026_ED_27111_1
Tender-75/Div-V (2025-26)
Open Tender
Electrical Works
Percentage
90 days
Sankhali
AS PER NIT
2 documents required · 2 mandatory
₹500
₹18,537
13 May 2026
9 Jan 2026
19 Jan 2026
10 Jan 2026
16 Jan 2026
12 Jan 2026
Cost of Material
RCC poles 11.0 Mtr long
RCC poles 9.0 Mtr long
RCC poles 7.5.0 Mtr long
Stay Set Complete for 11 mrt Rcc pole
GI Nut bolts 65X12mm
HDGI 11 KV 'V' shap cross arm with LA HDG clamps for 11mts long RCC pole
HDG top fitting cross arm of channel ISMC 75x40x6 mm 0.7 mtrs long along with HDG clamps for 11 mtrs along RCC pole
HDG gurad channel of 1.5 mtr long of channel ISMC 75 x 40 x6 mm. for 11.0 mtrs RCC pole
11 KV pin insulator with HDGI pin
11KV Disc Insulators along with hardware (45KN)
HDGI DP structure material
Supply and erection of 11 KV GOAB switches of 200 A
HDG earthing pipe 8ft long 40 mmdia Class B fabricated & perforated including alternate ;ayers of 30 cmc thick of charcoal,salt & earth (charcoal & salt10Kgs each per pit inclusive of excavation,bacfilling & spreading the earth evenly)
Supply and Erection of Distribution Box (M.S) with 400Amps MCCB & Kit-Kat fuses
Supply & erection of DTC Metering unit
Supply & erection of 4G Modem
XLPE single core unarmoured 50 sq mm 1.1 KV grade
11Kv/400 Volts Enamelled danger boards
HDG LT 4 pin cross arm channel type with HDG clamps for 11.0 mts long RCC pole
HDG LT 2 pin cross arm channel type with HDG clmaps for 11.0 mts long RCC pole
LT shackle insulator with Metal parts
LT Pin insulator with GI Pin
AA "ANT" conductor 7/3.10 for phase
AA "GNAT conductor 7/2.21 for double neutral & guard loops
GI Tubular fencing complete with Gateand side dismentaling system as per specification of Distribution Transformer and feeder Pillears (Size 4MX 3MX2M) with concreting for GI fencing supports with plinth (0.3X 0.3X0.5) Cu.m x12 Nos..Each Ratio 1:3:6 and brick masonary
ACSR"WEASEL" Conductor
Cost of Erection
RCC poles 11.0 Mtr long
RCC poles 9.0 Mtr long
RCC poles 7.5.0 Mtr long
Removing and Re-Erection of 200 KVA DTC
Stay Set Complete for 11 mrt Rcc pole
HDGI 11 KV 'V' shap cross arm with LA HDG clamps for 11mts long RCC pole
HDG top fitting cross arm of channel ISMC 75x40x6 mm 0.7 mtrs long along with HDG clamps for 11 mtrs along RCC pole
HDG gurad channel of 1.5 mtr long of channel ISMC 75 x 40 x6 mm. for 11.0 mtrs RCC pole
11 KV pin insulator with HDGI pin
11KV Disc Insulators along with hardware (45KN)
HDGI DP structure material
Supply and erection of 11 KV GOAB switches of 200 A
HDG earthing pipe 8ft long 40 mmdia Class B fabricated & perforated including alternate ;ayers of 30 cmc thick of charcoal,salt & earth (charcoal & salt10Kgs each per pit inclusive of excavation,bacfilling & spreading the earth evenly)
Removing of old FRP distribution Box
Supply and Erection of Distribution Box (M.S) with 400Amps MCCB & Kit-Kat fuses
Supply & erection of DTC Metering unit
HDG LT 4 pin cross arm channel type with HDG clamps for 11.0 mts long RCC pole
HDG LT 2 pin cross arm channel type with HDG clmaps for 11.0 mts long RCC pole
LT shackle insulator with Metal parts
LT Pin insulator with GI Pin
AA "ANT" conductor 7/3.10 for phase
AA "GNAT conductor 7/2.21 for double neutral & guard loops
GI Tubular fencing complete with Gateand side dismentaling system as per specification of Distribution Transformer and feeder Pillears (Size 4MX 3MX2M) with concreting for GI fencing supports with plinth (0.3X 0.3X0.5) Cu.m x12 Nos..Each Ratio 1:3:6 and brick masonary
Removing & Restringing of AAC ANT conductor for jointing
Removing & Restringing of AAC GANT conductor for jointing
Removing and re-erection of XLPE 1.1KV 3 & 1/2 c cable 240 sq. mm
Removing and re-erection of XLPE 1.1KV 3 & 1/2 c cable 120 sq. mm
Removing of 11KV GOAB switch 200 A
Removing of 11KV 200 A H.G Fuse unit
Removing of 9kv, 5KA lightening Arrestor
Removing of HDGI structural material
Removing of deteriorated HDG LT 4 pin cross arm channel type HDG clamps
Removing of deteriorated HDG LT 2 pin cross arm channel type HDG clamps
Removing of deteriorated HDG cut point channel of 1.3 mtr long of channel ISMC 75x 40 x 6 mm with HDG clamps
Removing of deteriorated HDGI 11 KV 'V' shape cross arm with LA HDG clamps
Removing of deteriorated HDG top fitting cross arm of channel ISMC 75x40x6 mm 0.7 mtrs long along with HDG clamps
Removing of deteriorated HDG gurad channel of 1.5 mtr long of channel ISMC 75x40x6 mm
Removing of 11KV pin insulator with HDG pin
Removing of 11KV Disc insulators with Metal part
Removing of 9 Mtr RCC pole
Removing of 7.5 Mtr RCC pole
ACSR"WEASEL" Conductor
Removing of LT shackle insulator with M.P
Removing of LT Pin insulator with GI Pin
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m.All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in:All works upto plinth level
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) All works upto plinth level
Centering & shuttering including Strutting, Propping & removal of forms for :Foundations, Footings, Bases for columns
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
12mm cement plaster 1:4 (1 cement : 4 coarse sand)
Painting three or more coats of arcyllic exterior paints of approved brand and manufacture (such as weather shield, APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete
Supply and spreading of 40 mm/20 mm of basaltic stone aggregates in the swichyard.
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 23.08 MB
BOQ_27553.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .