| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.0 L+₹3.5 L (12.9%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹31.0 L+₹3.6 L (13.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹33.3 L+₹5.9 L (21.5%)Rejected-Finance KOHLI NO 17509 GALI KHADDAR BHANDAR WALI BHI WALA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹40.3 L+₹12.9 L (47.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/s BHUPINDRA ENGINEERING WORKS L4 | M/s BALDEV SINGH L11 | M/s Vee Kay Associates L6 | M/s Luxmi Constructions L8 | SARJIT SINGH AND CO. L7 | RAKESH KUMAR GARG & CO. L1 | GUPTA AND ENGINEERS L2 | yogesh kumar contractor L10 | GARG INFRA PROJECTS L3 | REYANSH GARG AND COMPANY L9 | STELLAR PROJECTS L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of post or struts any type and any section including taking out embedded portion of concrete and making good disturbed ground, complete all as specified and directed by Engineer in Charge. | 320 | RUNNING METRE | 15 ₹4,800 Lowest | 20 ₹6,400 | 30 ₹9,600 | 27 ₹8,640 | 30 ₹9,600 | 50 ₹16,000 | 15 ₹4,800 Lowest | 30 ₹9,600 | 60 ₹19,200 | 100 ₹32,000 | 30 ₹9,600 |
| 2.00 | Dismantling fencing wire mesh, any type, complete all as specified and directed by Engineer in Charge. | 540 | SQUARE METER | 15 ₹8,100 | 10 ₹5,400 | 10 ₹5,400 | 9 ₹4,860 | 26 ₹14,040 | 10 ₹5,400 | 3 ₹1,620 Lowest | 10 ₹5,400 | 12 ₹6,480 | 200 ₹1,08,000 | 10 ₹5,400 |
| 3.00 | S&F mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to RCC post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc and including 10mm MS bars as in tie bars fixed to fencing posts including necessary welding where required, as per site requirement and other similar works complete, conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer in Charge. | 2,300 | KILO GRAM | 90 ₹2,07,000 | 90 ₹2,07,000 | 80 ₹1,84,000 Lowest | 90 ₹2,07,000 | 80 ₹1,84,000 Lowest | 90 ₹2,07,000 | 80 ₹1,84,000 Lowest | 80 ₹1,84,000 Lowest | 100 ₹2,30,000 | 120 ₹2,76,000 | 80 ₹1,84,000 Lowest |
| 4.00 | M&L for cement concrete type C-2 1:2:4 (using 40mm graded aggregate as in foundation and mass concrete of fixing steel posts or other similar works, complete all as specified and directed by Engineer in Charge. | 15.36 | CUBIC METRE | 2,500 ₹38,400 Lowest | 7,000 ₹1,07,520 | 6,000 ₹92,160 | 5,400 ₹82,944 | 6,000 ₹92,160 | 3,000 ₹46,080 | 5,000 ₹76,800 | 6,000 ₹92,160 | 3,200 ₹49,152 | 3,000 ₹46,080 | 6,000 ₹92,160 |
| 5.00 | S&F in repair galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc, complete all as specified and directed by Engineer in Charge.
Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment. | 5 | PER 100 RUNNING METRE | 1,200 ₹6,000 | 5,000 ₹25,000 | 1,200 ₹6,000 | 1,260 ₹6,300 | 1,200 ₹6,000 | 1,500 ₹7,500 | 500 ₹2,500 | 1,200 ₹6,000 | 1,600 ₹8,000 | 200 ₹1,000 Lowest | 1,200 ₹6,000 |
| 6.00 | Restraining resecuring including making good staples etc galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc, complete all as specified and directed by Engineer in Charge.
Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment. | 5 | PER 100 RUNNING METRE | 500 ₹2,500 | 1,000 ₹5,000 | 300 ₹1,500 | 360 ₹1,800 | 300 ₹1,500 | 1,000 ₹5,000 | 150 ₹750 Lowest | 300 ₹1,500 | 900 ₹4,500 | 200 ₹1,000 | 300 ₹1,500 |
| 7.00 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut exc 5 cm but not exc 22.50 cm long, diameter of neck n exc 12 mm, complete all as specified and directed by Engineer in Charge. | 40 | KILO GRAM | 120 ₹4,800 | 170 ₹6,800 | 150 ₹6,000 | 180 ₹7,200 | 150 ₹6,000 | 100 ₹4,000 | 80 ₹3,200 Lowest | 150 ₹6,000 | 90 ₹3,600 | 100 ₹4,000 | 150 ₹6,000 |
| 8.00 | S&F 4mm dia PVC coated galvanised mild steel chain link fencing of mesh size 50x50mm fixed with straining bolts including line wire any mesh size and of any type, rails, straining bolts etc, including provision of binding wire, complete all as specified and directed by Engineer in Charge. | 450 | SQUARE METER | 450 ₹2,02,500 | 375 ₹1,68,750 | 400 ₹1,80,000 | 450 ₹2,02,500 | 400 ₹1,80,000 | 700 ₹3,15,000 | 400 ₹1,80,000 | 400 ₹1,80,000 | 775 ₹3,48,750 | 250 ₹1,12,500 Lowest | 400 ₹1,80,000 |
| 9.00 | Demolition of brick work/PCC block masonry work built in cement mortar in manholes, septic tank, soakage wells etc, complete all as specified and directed by Engineer in Charge. | 27.5 | CUBIC METRE | 150 ₹4,125 | 200 ₹5,500 | 250 ₹6,875 | 279 ₹7,672.5 | 250 ₹6,875 | 100 ₹2,750 | 20 ₹550 Lowest | 250 ₹6,875 | 95 ₹2,612.5 | 5,000 ₹1,37,500 | 250 ₹6,875 |
| 10.00 | Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specifically provided for including removing debris out side MD land, complete all as specified and directed by Engineer in Charge. | 70.7 | CUBIC METRE | 200 ₹14,140 | 200 ₹14,140 | 220 ₹15,554 | 270 ₹19,089 | 220 ₹15,554 | 100 ₹7,070 | 350 ₹24,745 | 220 ₹15,554 | 85 ₹6,009.5 Lowest | 5,000 ₹3,53,500 | 220 ₹15,554 |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
12 Jul 2025, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN - 151201
REPAIR TO SECURITY FENCING GATE GARBAGE BINS DRAIN PATH CULVERT HARD STANDING AT OTHER MISC WORKS REPAIR /MAINT AND CLEANING OF SEWERAGE SYSTEM IN DOMESTIC AREA (ZONE-I) NANDINI COMPLEX AT AF STN BHISIANA
2025_MES_715584_1
GE/BHI/T-50/2025-26
Open Tender
Civil Works
Item Rate
273 days
GE (AF) BHISIANA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) BHISIANA
₹74,000
Yes
11 Aug 2025
19 Jun 2025
15 Jul 2025
19 Jun 2025
12 Jul 2025
5 Jul 2025
19 Jun 2025 - 28 Jun 2025
Amount
Dismantling of post or struts any type and any section including taking out embedded portion of concrete and making good disturbed ground, complete all as specified and directed by Engineer in Charge.
Dismantling fencing wire mesh, any type, complete all as specified and directed by Engineer in Charge.
S&F mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to RCC post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc and including 10mm MS bars as in tie bars fixed to fencing posts including necessary welding where required, as per site requirement and other similar works complete, conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer in Charge.
M&L for cement concrete type C-2 1:2:4 (using 40mm graded aggregate as in foundation and mass concrete of fixing steel posts or other similar works, complete all as specified and directed by Engineer in Charge.
S&F in repair galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc, complete all as specified and directed by Engineer in Charge. Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
Restraining resecuring including making good staples etc galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc, complete all as specified and directed by Engineer in Charge. Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut exc 5 cm but not exc 22.50 cm long, diameter of neck n exc 12 mm, complete all as specified and directed by Engineer in Charge.
S&F 4mm dia PVC coated galvanised mild steel chain link fencing of mesh size 50x50mm fixed with straining bolts including line wire any mesh size and of any type, rails, straining bolts etc, including provision of binding wire, complete all as specified and directed by Engineer in Charge.
Demolition of brick work/PCC block masonry work built in cement mortar in manholes, septic tank, soakage wells etc, complete all as specified and directed by Engineer in Charge.
Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specifically provided for including removing debris out side MD land, complete all as specified and directed by Engineer in Charge.
Demolition of RCC manhole, septic tank cover slabs and similar works etc, complete all as specified and directed by Engineer in Charge.
M&L for Plain Cement Concrete 1:3:6 type C2 (using 40mm stone agg) as in foundation bed concrete etc, complete all as specified and directed by Engineer in Charge.
M&L for Reinforced cement concrete 1:2:4 Type B1 (20 mm graded aggregate) in Columns, pillars, piers, posts and struts etc coping, benching of manholes etc, complete all as specified and directed by Engineer in Charge.
M&L for formwork to sides of concrete, foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface, complete all as specified and directed by Engineer in Charge.
S&F TMT MS bar 8mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia, complete all as specified and directed by Engineer in Charge.
M&L Plain cement concrete 1:2:4 type B1 (using 20 mm graded stone agg) as in coping, benching of drain and similar work etc complete in foul conditions, complete all as specified and directed by Engineer in Charge.
M&L Brick work with sub class 'B' bricks in CM 1:6, straight or curved on plan exc 6 mtr mean radius, using old size bricks in foul conditions, complete all as specified and directed by Engineer in Charge.
M&L for 50mm thick Cement concrete 1:2:4 type B- 2 (40mm graded aggregate) aggregate as in floor topping of hard standing/ floor finished even and smooth without using extra cement (PCC shall be laid in alternate bays in panels of size, complete all as specified and directed by Engineer in Charge.
M&L for 75 mm thick Cement concrete 1:4:8 type D-2 (40mm graded aggregate) as in sub base to paving, complete all as specified and directed by Engineer in Charge.
M&L for Glossy finish chequered cement concrete tiles 30cm x 30cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment, complete all as specified and directed by Engineer in Charge.
M&L for Glossy finish machine pressed precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment, complete all as specified and directed by Engineer in Charge.
M&L for heavy duty endure ceramic coloured tiles 9-10 mm thick dark shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floor etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed by Engineer in Charge.
M&L for sand coshing 25mm thick for under floor/foundation or interlocking tiles incl watering and consolidation, complete all as specified and directed by Engineer in Charge.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar, complete all as specified and directed by Engineer in Charge.
M&L for Dholpur stone with hammer dressed face work (with maximum depression from a straight edge held against the dressed surface not exc 20mm), about 40mm high, 75mm deep in straight courses, laid and jointed in cement and stone dust mortar 1:3, recess pointed (10mm x 20mm) with an admixture of white cement and Dholpur stone dust 1:1, complete all as specified and directed by Engineer in Charge.
M&L for Granite (of any Type) work table rubbed and polished 18-20 mm thick machine cut, in steps, jams,pillars, window cills, cooking platforms and like laid and bedded over 15 mm thick cement mortar in CM(1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed by Engineer in Charge.
Rounding the edge of stone slabs one edge such as in steps, cooking platforms and the other similar situation, complete all as specified and directed by Engineer in Charge.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer in Charge.
M&L for rendering 15 mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces and finishing the surface even and fair etc, complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of cement base primer on new plastered surfaces, complete all as specified and directed by Engineer in Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed by Engineer in Charge.
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated in Fe-290 (Gde E165) etc, complete all as specified and directed by Engineer in Charge.
S&F Roof trusses (framed), trussed, purloins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410 -W (GdeE- 250) quality, complete all as specified and directed by Engineer in Charge.
M&L for providing and fixing stainless steel (Grade 304) railing/gates made of hollow tubes, channels, plates, nobs etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, complete all as specified and directed by Engineer in Charge.
Painting to new or previously untreated steel surfaces of any description over 10 cm in width or girth with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces, complete all as specified and directed by Engineer in Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engineer in Charge.
S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer in Charge.
Cleaning of Sewer line Depth 1.5 mtr to 3 mtr and dia of pipe up to 300 mm by mechanically truck/tractor mounted hydro jet sewage line cleaning machine of sewage line water sludge tank with wash down system / suck derrick arm hydraulically spring loaded rotary sliding vane compressor with V hose end section nozzle and strainer, complete all as specified and directed by Engineer in Charge. Note : The quoted rate includes removing and refixing of manhole covers.
Cleaning of sewer line depth 3 mtr to 5 mtr and dia of pipe up to 300 mm by mechanically truck/ tractor mounted hydro jet sewage line cleaning machine of sewage line water sludge tank with wash down system / suck derrick arm hydraulically spring loaded rotary sliding vane compressor with V hose end section nozzle and strainer, complete all as specified and directed by Engineer in Charge. Note : The quoted rate includes removing and refixing of manhole covers.
Desilting and cleaning of manhole chamber of any shape/ size depth exceeding 0.6 Mtr not exceeding 1.5 Mtr by removing sludge/ mud, silt, liquid etc (in foul condition) to outside MD land premises by manual and mechanical means after stopping of sewage flow by sand bags, gunny bags and ensure the the flow by removing the same after cleaning, all as specified and directed Note : The quoted rate includes removing and refixing of manhole covers.
Desilting and cleaning of manhole chamber of any shape/ size depth exceeding 0.6 Mtr but n exc 1.5Mtr by removing sludge/ mud, silt, liquid etc (in foul condition to outside MD land premises including testing of manholes by filling with water ), complete all as specified and directed by Engineer in Charge. Note : for ser item No 1 to 4:- (i) The rates quoted in the above item includes cost of T&P like rods, bamboos, gum shoes, shovel and hand glouses etc complete.
Desilting and cleaning of manhole chamber of any shape/size depth exceeding 3 Mtr n.exc 4.5 mtr by removing sludge/mud, silt, liquid etc (in foul condition) to outside MD land premises by manual and mechanical means after stopping of sewage flow by sand bags, gunny bags and ensure the the flow by removing the same after cleaning, complete all as specified and directed by Engineer in Charge. Note: The quoted rate includes removing and refixing of RCC manhole covers and works shall be carried out with all safety precautions.
Desludging/ dewatering, Cleaning of septic tank/manholes of any depth, including sludge by pumping out of sludge using mechanical equipment and transported by a vehicle of capacity 6000 Ltrs and removed outside MD land including cleaning off shrubs/bushes, vegetarian found around 2 Mtrs from external edge of septic tank and sludge chamber, complete all as specified and directed by Engineer in Charge. Note : The quoted rate includes removing and refixing of RCC manhole covers and works shall be carried out with all safety precautions.
Cleaning of sewage line blockage by rodding from manhole to manhole, Manhole to cleaning eye including that from first manhole to cleaning eye of down take pipe and removing all debris, sludge and solid material from sewage line and removal from site and well flushing with water after cleaning vertical pipe of following dia of pipes at any depth, complete all as specified and directed by Engineer in Charge. Depth of line up to 3 Mtr and the dia of pipe as per item no 46 & 47(Below)
150mm internal dia.
200mm internal dia
M&L for 15mm thick plaster on fair faces of brick work or concrete surfaces, mixed WPC @3% of weight of cement in CM 1:4, complete all as specified and directed by Engineer in Charge. Note :- Water Proofing compound shall be measured and paid separately under appropriate Item.
Supply only integrated water proofing compound @ 3% weight of cement or as per manufacturer instruction, complete all as specified and directed by Engineer in Charge.
M&L for 75 mm thick reinforced precast cement concrete 1:1:2 type B-1 (using 20mm graded stone aggregate) as in manhole cover bromatic slabs finish fair even and smooth without using extra cement (Top surface will be chequered finish) including S&F 2mm thick CR sheet all around the cover with 2 coat of bitumen paint and two round sunk steel handle 12mm dia to surface, complete all as specified and directed by Engineer in Charge. Note: (i) TMT MS bars welded with 2mm thick CR sheet for making frame. (ii) Reinforcement (only TMT bars) shall be measured and paid separately)
Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth as in foundation, drain etc, complete all as specified and directed by Engineer in Charge.
Excavation in trenches in hard/dense soil exc 1.5m upto 3.0m depth as in foundation, drain etc, complete all as specified and directed by Engineer in Charge.
Returning filling in including spreading, levelling watering and well ramming in layers n.exc 25 cm in hard/dense soil, complete all as specified and directed by Engineer in Charge.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level not exc 1.5 m above the the starting point, complete all as specified and directed by Engineer in Charge.
Demolition and breaking up of 150 mm dia sewage/ drain pipe with bed concrete set in cement mortar including removing debris out side MD land, complete all as specified and directed by Engineer in Charge.
S&F PVC (SWR) 150mm bore (dia) 6 kg/Sqcm Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid in Floors, complete all as specified and directed by Engineer in Charge.
M&L for 150mm dia salt glazed stoneware drain pipe (SGSW) grade 'A' laid in trenches and jointed in CM 1:1 and tested, complete all as specified and directed by Engineer in Charge.
M&L for Concrete bed to drain pipes including forming cradles in Plain cement concrete 1:4:8 type D2 (using 40 mm graded aggregate) for PVC (SWR)/RCC, Soil pipes after they are laid and tested for 150 mm dia bore pipe, complete all as specified and directed by Engineer in Charge.
Cutting into existing manholes for connecting new drains 150/200mm bore pipe including removing existing branch drain pipes of 150/200mm bore & benching to form branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) surface finished and reforming benching as required and making good surface with plaster etc to match existing, complete all as specified and directed by Engineer in Charge.
Demolition and breaking up of 200 mm dia SGSW drain pipe with bed concrete set in cement mortar including removing debris out side MD land, complete all as specified and directed by Engineer in Charge.
M&L for 200mm dia salt glazed stoneware drain pipe (SGSW) grade 'A' laid in trenches and jointed in Cement Mortar 1:1 and tested, complete all as specified and directed by Engineer in Charge.
M&L for Concrete bed to drain pipes including forming cradles in Plain Cement Concrete 1:4:8 type D2 (using 40 mm graded aggregate) for PVC (SWR)/RCC, Soil pipes after they are laid and tested for 200 mm dia bore pipe, complete all as specified and directed by Engineer in Charge.
Taking down PVC/ CI Pipe of any 110mm dia and any descriptions, fixed to Walls, laid on Floors, etc, complete all as specified and directed by Engineer in Charge.
Taking down PVC/ CI Pipe of any 75mm dia and any descriptions, fixed to Walls, laid on Floors, etc, complete all as specified and directed by Engineer in Charge.
S&F PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, fixed to Walls/floor, complete all as specified and directed by Engineer in Charge.
S&F PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, fixed to Walls/floor, complete all as specified and directed by Engineer in Charge.
S&F PVC (SWR) Bends (any radius), Diminishing Pieces or Tapers (larger bore measured) Fittings for PVC (SWR) Pipe 75mm bore (dia), jointing with Solvent Cement, complete all as specified and directed by Engineer in Charge.
S&F PVC (SWR) Bends (any radius), Diminishing Pieces or Tapers (larger bore measured) Fittings for PVC (SWR) Pipe 110mm bore (dia), jointing with Solvent Cement, complete all as specified and directed by Engineer in Charge.
M&L 50mm thick Cement Concrete 1:4:8 (40mm graded stone aggregate) in Sub-base under Pavements, etc, complete all as specified and directed by Engineer in Charge.
M&L for Machine Pressed Precast concrete interlocking paver block glossy finish any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 grade with grey cement with pigment, complete all as specified and directed by Engineer in Charge.
GUPTA AND ENGINEERS (BID ID -3355763)
GARG INFRA PROJECTS (BID ID -3355036)
M/s BHUPINDRA ENGINEERING WORKS (BID ID -3356130)
STELLAR PROJECTS (BID ID -3356450)
M/s Vee Kay Associates (BID ID -3356527)
SARJIT SINGH AND CO. (BID ID -3356759)
M/s Luxmi Constructions (BID ID -3356573)
REYANSH GARG AND COMPANY (BID ID -3356334)
yogesh kumar contractor (BID ID -3356314)
M/s BALDEV SINGH (BID ID -3356445)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .