| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | ₹15.2 L Quoted ₹15.7 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹17.8 L+₹2.1 L (13.4%)Rejected-AOC | ₹17.8 L+₹2.1 L (13.4%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹18.1 L+₹2.5 L (15.8%)Rejected-AOC 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹18.1 L+₹2.5 L (15.8%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹18.2 L+₹2.5 L (15.9%)Rejected-AOC | ₹18.2 L+₹2.5 L (15.9%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹20.9 L+₹5.3 L (33.7%)Rejected-AOC | ₹20.9 L+₹5.3 L (33.7%) | L5 | Rejected-AOC Rejected |
Tender Value
₹20.0 L
EMD Value
₹39,980
Closing Date
2 Sept 2021, 5:00 pmClosed
GE GOMANTAK VASCO
GE GOMANTAK VASCO DA GAMA PIN 403802
Repair Maintenance of DG sets at Alparquerious Hill NCB 2W Det NAD and NOFRA area under GE Gomantak Vasco
2021_MES_465417_1
8316/E8
Open Tender
Support/Maintenance Service
Item Rate
270 days
VASCO DA GAMA
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE GOMANTAK
₹39,980
Yes
6 Nov 2021
5 Aug 2021
3 Sept 2021
5 Aug 2021
2 Sept 2021
18 Aug 2021
Amount
Service Charges for Carrying out maintenance for DG sets of authorised rep or service engineer from the OEM of DG set of Kirloskar/ Cummins make of 400KVA at HQGNA, injector & valve tappet setting, checking of vibration damper, checking turbocharger, oil leakage, tightening mounting screws & nuts, replacement of filters & oil, checking inlet & Exhaust manifold cap, screws, checking of fan hub & water pump, removing the existing unserviceable engine oil, clean the oil sump and refilling with required quantity of new oil & coolant top up, charging of battery, filling of distilled water, cleaning of radiator fins by using blower / inside tank with solution (caustic soda with water) to the entire satisfaction of Engr-in-charge, trial & testing etc. (Note : (a) New spares required for repairing will be measured and paid seperately as supply only.
Supply only Kit fuel filter and ring.Make:Kirloskar/Mico
Supply only Element for Lubrication oil filter.Make:Kirloskar/Mico
Supply only Kit Element of super bypass filter.Make:Kirloskar/Mico
Supply only Air filter element Make:Kirloskar/Mico
Supply only water filter Make:Kirloskar/Mico
All as per item No 1 above but DG set of Engine Cummins of 380 KVA capacity at NAD APRE II
Supply only Kit fuel filter and ring.Make:Kirloskar/Mico
Supply only Element for Lubrication oil filter.Make:Kirloskar/Mico
Supply only Kit Element of super bypass filter.Make:Kirloskar/Mico
Supply only Air filter element Make:Kirloskar/Mico
Supply only water filter Make:Kirloskar/Mico
All as per item No 1 above but DG set of Engine Cummins of 200 KVA capacity at MIG Wk shop and AC plant Mag No.3 of NAD
Supply only Kit fuel filter and ring.Make:Kirloskar/Mico
Supply only Element for Lubrication oil filter.Make:Kirloskar/Mico
Supply only Kit Element of super bypass filter.Make:Kirloskar/Mico
Supply only Air filter element Make:Kirloskar/Mico
Supply only water filter Make:Kirloskar/Mico
All as per item No 1 above but DG set of Engine Cummins of 160 KVA capacity at GNA pump house House,New COMCEN, NOFRA, INHS Jeevanti and NCN
Supply only Kit, fuel filter and ring.Make:Kirloskar/Mico
Supply only Element for Lubrication oil filter.Make: Kirloskar
Supply only Kit, Element of super bypass filter.Make: Kirloskar
Supply only water filter.Make: Kirloskar/Mico
Supply only Element Air filter .Make: Kirloskar/Mico
Supply only Gasket, Rocker lever cover .Make: Kirloskar/Mico
All as per item No 1 above but DG set of Engine Cummins of 125 KVA capacity at NOFRA
Supply only Kit, fuel filter and ring.Make:Kirloskar/Mico
Supply only Element for Lubrication oil filter.Make: Kirloskar
Supply only Kit, Element of super bypass filter.Make: Kirloskar
Supply only water filter.Make: Kirloskar/Mico
Supply only Element Air filter .Make: Kirloskar/Mico
Supply only Gasket, Rocker lever cover .Make: Kirloskar/Mico
All as per item No 1 above but DG set of Engine Cummins powerica/Cummins of 82.5/100 KVA capacity at 2W Det/Jeevanti Power House/AC Plant
Supply only Fuel Filter .Make: Kirloskar/Mico
Supply only Cartridge, Lub oil filter .Make: Kirloskar/Mico
Supply only Separator, Fuel water .Make: Kirloskar/Mico
Supply only Element Air filter.Make: Kirloskar
Supply only Gasket, Valve cover.Make: Kirloskar/Mico
All as per item No 1 above but DG set of 40 to 63 KVA capacity of any Engine at GNA pump house, 2W Det, NHS and NCB.
Supply only Lubrication oil filter, cartridge.Make: Kirloskar/Mico
Supply only Fuel Filter assy Primary.Make: Kirloskar/Mico
Supply only Fuel Filter assy Secondary.Make: Kirloskar/Mico
Supply only Air filter element . Make:Kirloskar/Mico
Note :- (1) The Maint spares, engine oil, Coolant will be measured and paid separately under relevent item of this schedule. 2. Any other check as per menufacturer's instructions / Engr In charge directeion shall be carried out by the contractor and the same may be included in the quoted rate.and directed by Engineer-in-charge.
Supply & filling Coolant concentrate Superkool xtra as required in the DG set all as directed. Make : TVS/SERVO
Supply & filling Engine Oil Premium Blue 15 W 40 grade API CI 4 PLUS as required in the DG set oil sump all as directed. Make : VALVOLINE/SERVO.
Dismantling the defective alternator of any capacity from the existing foundation and from Engine after removing all electrical connections, transporting to approved / authorised / directed workshop, opening and taking out burnt winding, cleaning the stator assy rewinding with super enameled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of ‘F’ class, baking in oven re-assembling the alternator, transporting back to site re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete. Note : - (a) Rate quoted shall be deemed to be inclusive of making good the disturbed surfaces. (b) The DG set shall be tested on load as per rated capacity for the satisfaction of Engineer- in- Charge to achieve designed parameters.
S & F in repair door hinges for canopy of any capacity of DG set door including nut, bolt, drilling of hole, welding as per directed.
Dismantling the old and unserviceable DG Set rubber hose pipe up to 2'' dia and replacing the same with of existing size and equal length for any capacity DG Set including both side hose clamp, with nut, bolt and washers as required , etc as directed by the Engineer in Charge .
Ditto all as per item No 48 here in before but of hose size 3" all as directed.Make: Kirloskar/Mico
Ditto all as per item No 48 here in before but of hose size 4" all as directed.Make: Kirloskar/Mico
Supply and fixing in repair battery terminals brass suitable for 95 AH to 180 AH battery .
Supply and fixing in repair rectifiers diodes for any capacity DG sets of existing make.
Dismantling the radiator assy from any capacity DG set carefully for necessary repair , soldering the cooling tube if found weak /leakage , cleaning properly , replacement of nuts , bolts , rubber mounting bushes etc and refixing the same at site including testing on completion.
S & F in repairs connecting and commissioing lead acid battery 12 volts 180 AH . Make : Exide Express /Amaron
S & F in repiars connecting and commissioing lead acid battery 12 volts 135 AH .Make : Exide Express / Amaron
Dismantling the unserviceable Dynamo / Alternators 12/24 volts and rewinding with ‘F’ class copper wire of 22 /existing gauge incl dismantling the old coil, cleaning thoroughly and winding with super enamelled copper cord of existing size and gauge, varnishing, drying etc and re fixing with dynamo/alternator properly including testing on completion.
Dismantling the defective Dynamo /Alternators 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring, and soldering after re-fixing at site.
Dismantling the defective self starter assy of 12/24 volts and necessary repair with replacement of defective spares such as, carbon brushes, carbon spring, bearing, bushes, defective wiring and soldering after repair, re-assembling and refixing at site complete as directed including testing on completion.
M&L for providing new AVR unit suitable for anycapacity DG Set size in repairs ie taking down of old AVR unit, complete all as specified and as directed by Engineer -in-charge. Make: Kirloskar/cummins/stanford
M&L for providing new control panel assy suitable for any capacity DG Set size in repairs ie taking down of old unit, complete all as specified and as directed by Engineer -in-charge. Make: Kirloskar/cummins/stanford
M&L for providing new feed pump suitable for any capacity DG Set size in repairs ie taking down of old feed pump, complete all as specified and as directed by Engineer -in-charge. Make: Kirloskar/cummins/stanford
Dismantling the defective exciter of DG set of any capacity from the existing foundation and engine after removing all electrical connections, transporting to workshop rewinding the burn out coil complete with super enamelled copper wire rewinding, applying insulating varnish of 'F' class baking in oven reassembling the alternator, transporting back to site, re-installing the same carrying out alignment of complete DG Set connecting up all electrical connections, testing & commissioning complete.
Supply and fixing in repair digital type volt meter square type 96x96 mm up to 3 Phase AC 50 HZ, 500 volts of and connecting complete make : Meco/AE or equivalent all as directed.
Supply and fixing copper cable multi stranded suitable for 12/24 volts, 135/180 AH battery replacing the same with of existing size and equal length complete fixing with brass clamp at both ends including taking down of old one from the existing battery.
S &F in repair asbestos rope 12 mm dia of superior quality for wrapping with the exhaust pipe of anycapacity DG set complete as directed.
S&F in replacement V belt suitable for anycapacity DG Set as per existing model and size including dismantling the old one. Make: Kirloskar/Mico
Scraping the old paint from the DG set of 400 KVA capacity including outer bodyof silent DG set, applying spray paint two coats of synthetic enamel paint of approved make and writing of SM/MES No at easily visible manner complete as directed.
All as per item No 67 above but DG Set 40 KVA to 100 KVA DG Set.
S & F in repairs Injector assy for any capacity of existing make DG Set for Cummins / Kirloskar / Greaves DG Set
S & F in repairs self starter 12V/24V with solinoid switch assy complete set as per existing make of DG Set of any capacity all as directed. Make Kirloskar / TVS Lucas
S & F in repairs new Dynamo / Alternator assy 12 / 24 Volts of existing type and capacity suitable for DG set incl necessary elect connections all as directed.Make: Kirloskar/Mico
S & F in repairs micro processor based DG control unit suitable for any Capacity DG sets of existing make incl neccessary connections and testing complete all as directed.Make: Kirloskar/Mico
S & F in repairs Excitor rotor assy suitable for any Capacity DG sets of existing make incl neccessary connections and testing complete all as directed.Make: Kirloskar/Mico
S & F in repairs Excitor stator assy suitable for any Capacity DG sets of existing make incl neccessary connections and testing complete all as directed.Make: Kirloskar/Mico
S & F in repairs fuel pump assy suitable for any Capacity DG sets of existing make incl neccessary connections and testing complete all as directed.Make: Kirloskar/Mico
S & F in repairs Oil pump assy suitable for any Capacity DG sets of existing make incl neccessary connections and testing complete all as directed.Make: Kirloskar/Mico
S & F in repairs silencer suitable for any Capacity DG sets of existing make incl neccessary connections and testing complete all as directed.Make: Kirloskar/Mico
S & F in repairs fuel level sensor suitable for any Capacity DG sets of existing make incl neccessary connections and testing complete all as directed.Make: Kirloskar/Mico
S & F in repairs onload Change over switch 250 Amps, 415 Volt, 4 pole Make: Scheneder/ Havells/ L&T
S & F in repairs air cleaner assy with element suitable for any Capacity DG sets of existing make incl neccessary connections and testing complete all as directed. Make: Kirloskar/Mico
Dismantling and taking out the defected Electromagnetic speed Governor unit with fuel injector pump assy from any capacity DG set, transport to authorised work shop, cleaning the Fuel injector, Nozzle, calibration in test bench re-assembling into the DG set at site with necessary new gaskets/ nut, bolt and washer and testing complete all as directed. Note : The cost of spares like new injector / nozzle / gasket are deemed to be included in the quoted rates.
Service Charges for Carrying out maintenance for AMF Panel of 400 KVA DG sets of authorised rep or service engineer from the OEM of DG set of Kirloskar/ Cummins to the entire satisfaction of Engr-in-charge, trial & testing etc. (Note : (a) New spares required for repairing will be measured and paid seperately as supply only.
S & F in repairs self starter push button / with Key arrangement for DG starting suitable for any capacity / any make DG sets all as directed.Make: Kirloskar/Mico
S & F in repairs Relays suitable for any capacity DG Set AMF Pannel of existing make incuding testing to the entire satisfaction of Engr-in-Charge.Make: Kirloskar/Mico
S&F in repairs AMF pannel Power contactor MNX 185, 250 Amps,415V, 3 pole, 3 phase incuding testing to the entire satisfaction of Engr-in-Charge. Make: L&T/Havells/Scheneder
S&F in repairs AMF pannel Power contactor MCX 32, 160 Amps,415V, 4 pole, 3 phase incuding testing to the entire satisfaction of Engr-in-Charge Make: L&T/Havells/Scheneder
S&F in repairs AMF pannel Power contactor MCX 22, 100 Amps,415V, 4 pole, 3 phase incuding testing to the entire satisfaction of Engr-in-Charge. Make: L&T/Havells/Scheneder
S&F in repairs AMF pannel Analogue timer on delay 0.35 of any capacity DG set, incuding testing to the entire satisfaction of Engr-in-Charge
S & F of distilled water in the DG set battery of any capacity all as directed.
M & L for opening the cylinder head of the engine and oil sump carefully for replacement of head gasket including sump gasket complete refixing the head and sump to arrest oil leakage with engine complete with proper alignment and testing the engine for 1 hrs on load to achive designed parameters of any capacity DGset all as directed by Engineer-in-Charge.
Star Freeze Service
SHIVANI ENTERPRISES
KAMINS CARE
M/s Gayatri Contruction Co.
D.K. ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .