Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC | ₹49.4 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹52.1 L+₹2.7 L (5.42%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | ₹52.1 L+₹2.7 L (5.42%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹52.7 L+₹3.3 L (6.61%)Rejected-Finance | ₹52.7 L+₹3.3 L (6.61%) | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹53.7 L+₹4.2 L (8.59%)Rejected-Finance | ₹53.7 L+₹4.2 L (8.59%) | L4 | Rejected-Finance Rejected being L4 |
| 5 | L6₹54.6 L+₹5.2 L (10.5%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | ₹54.6 L+₹5.2 L (10.5%) | L6 | Rejected-Finance Rejected being L6 |
| Sl No | Description | Qty | Unit | M/S K S Enterprise L1 | STANDARD ELECTRIC WINDERS L2 | AFTAB ENTERPRISES L4 | M/S P R SINGH AND SONS L8 | D N ENTERPRISE L6 | M/S S.A.Electrics L7 | FREEZCON L3 | S K ENTERPRISE L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for servicing of 750 KVA DG Set by carrying out the following maintenance including testing on completion at connected laod for entire satisfaction of Engr-in-Charge and complete all as specified and directed at site.
(i) Draining out engine oil feom the sump by removing drain plug,cleaning the sump throughly and refilling the sump with new engine oil to required level (Note : Engine oil will be measured and paid separately)
(ii) Replace complete fuel filters, oil filters and air filter element.(Note : fuel filters, oil filters and air filter element will be measured and paid separately)
(iii) Draining out complete coolant water mixture from the radiator and refilling the radiator with new coolent and water mixture with proportionate ratio (Note : coolent will be measured and paid separately as Supply only)
(iv) Draining out diesel from disel tank and storing in cleaned containers,cleaning the tank throughly by removing sediments settled at the bottom and refilling the drained out diesel duly filtered.
(v) Check and top up the electrolyte/distilled water in starting batterie cells to maintain the required specific gravity.Cleaning of battery terminals & applying petroleum jelly to battery poles & brass connectors.
(vi) Tightening all the fasteners of complete DG set to the required torque.
(vii)Tightening of all gaskets, connection of battery terminals, cable connections, foundation bolts, coupling bolts etc including test running and tappet setting of alternator by checking and setting of voltage and frequencies complete. | 6 | Each Job | 8,190 ₹49,140 Lowest | 8,730 ₹52,380 | 8,800 ₹52,800 | 9,000 ₹54,000 | 8,840 ₹53,040 | 8,900 ₹53,400 | 8,610 ₹51,660 | 8,850 ₹53,100 |
| 2.00 | All as per ser item No 1 here-in-before but Cap of DG Set 320KVA | 6 | Each Job | 6,810 ₹40,860 | 6,800 ₹40,800 Lowest | 7,300 ₹43,800 | 7,600 ₹45,600 | 7,380 ₹44,280 | 7,426 ₹44,556 | 7,138 ₹42,828 | 7,330 ₹43,980 |
| 3.00 | All as per ser item No 1 here-in-before but Cap of DG Set 180/160 KVA | 10 | Each Job | 5,990 ₹59,900 | 6,400 ₹64,000 | 6,160 ₹61,600 | 6,400 ₹64,000 | 6,200 ₹62,000 | 6,246 ₹62,460 | 5,980 ₹59,800 Lowest | 6,160 ₹61,600 |
| 4.00 | All as per ser item No 1 here-in-before but Cap of DG Set 125/100 KVA | 4 | Each Job | 5,210 ₹20,840 Lowest | 6,160 ₹24,640 | 5,660 ₹22,640 | 5,900 ₹23,600 | 5,700 ₹22,800 | 5,750 ₹23,000 | 5,500 ₹22,000 | 5,670 ₹22,680 |
| 5.00 | All as per ser item No 1 here-in-before but Cap of DG Set 70/62.5 KVA | 16 | Each Job | 4,480 ₹71,680 | 5,150 ₹82,400 | 4,475 ₹71,600 Lowest | 5,300 ₹84,800 | 5,160 ₹82,560 | 5,202 ₹83,232 | 5,000 ₹80,000 | 5,150 ₹82,400 |
| 6.00 | All as per ser item No 1 here-in-before but Cap of DG Set 45/40/35 KVA | 10 | Each Job | 4,220 ₹42,200 | 4,200 ₹42,000 Lowest | 4,960 ₹49,600 | 5,200 ₹52,000 | 5,010 ₹50,100 | 5,044 ₹50,440 | 4,800 ₹48,000 | 5,000 ₹50,000 |
| 7.00 | All as per ser item No 1 here-in-before but Cap of DG Set 30/25 KVA | 10 | Each Job | 4,000 ₹40,000 | 3,985 ₹39,850 Lowest | 4,850 ₹48,500 | 5,200 ₹52,000 | 4,950 ₹49,500 | 4,977 ₹49,770 | 4,600 ₹46,000 | 5,000 ₹50,000 |
| 8.00 | Supply only Pre filter cartridge suitable for 750 KVA DG set (Set of Two) | 6 | Each | 32,745 ₹1,96,470 Lowest | 35,600 ₹2,13,600 | 36,000 ₹2,16,000 | 37,000 ₹2,22,000 | 36,200 ₹2,17,200 | 36,450 ₹2,18,700 | 35,000 ₹2,10,000 | 36,000 ₹2,16,000 |
| 9.00 | Supply only Final filter cartridge suitable for 750 KVA DG set (Set of Two) | 6 | Each | 18,560 ₹1,11,360 Lowest | 19,200 ₹1,15,200 | 21,000 ₹1,26,000 | 22,000 ₹1,32,000 | 21,200 ₹1,27,200 | 21,250 ₹1,27,500 | 20,000 ₹1,20,000 | 21,000 ₹1,26,000 |
| 10.00 | Supply only disel filter suitable for 320 kVA DG set (Set of Two) | 12 | Each | 3,585 ₹43,020 | 3,720 ₹44,640 | 3,680 ₹44,160 | 3,800 ₹45,600 | 3,700 ₹44,400 | 3,732 ₹44,784 | 3,580 ₹42,960 Lowest | 3,700 ₹44,400 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
26 Nov 2025, 6:00 pmClosed
GE (AF) CHABUA
GE (AF) CHABUA
REPAIR/MAINTENANCE OF DG SETS AND ASSOCIATED WORKS AT TECH AREA AT AF STNS UNDER GE (AF) CHABUA
2025_MES_738507_1
748
Open Tender
Civil Works
Item Rate
270 days
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUG
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) CHABUA
₹90,000
Yes
10 Dec 2025
5 Nov 2025
28 Nov 2025
5 Nov 2025
26 Nov 2025
19 Nov 2025
5 Nov 2025 - 12 Nov 2025
Amount
Material and labour for servicing of 750 KVA DG Set by carrying out the following maintenance including testing on completion at connected laod for entire satisfaction of Engr-in-Charge and complete all as specified and directed at site. (i) Draining out engine oil feom the sump by removing drain plug,cleaning the sump throughly and refilling the sump with new engine oil to required level (Note : Engine oil will be measured and paid separately) (ii) Replace complete fuel filters, oil filters and air filter element.(Note : fuel filters, oil filters and air filter element will be measured and paid separately) (iii) Draining out complete coolant water mixture from the radiator and refilling the radiator with new coolent and water mixture with proportionate ratio (Note : coolent will be measured and paid separately as Supply only) (iv) Draining out diesel from disel tank and storing in cleaned containers,cleaning the tank throughly by removing sediments settled at the bottom and refilling the drained out diesel duly filtered. (v) Check and top up the electrolyte/distilled water in starting batterie cells to maintain the required specific gravity.Cleaning of battery terminals & applying petroleum jelly to battery poles & brass connectors. (vi) Tightening all the fasteners of complete DG set to the required torque. (vii)Tightening of all gaskets, connection of battery terminals, cable connections, foundation bolts, coupling bolts etc including test running and tappet setting of alternator by checking and setting of voltage and frequencies complete.
All as per ser item No 1 here-in-before but Cap of DG Set 320KVA
All as per ser item No 1 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 1 here-in-before but Cap of DG Set 125/100 KVA
All as per ser item No 1 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 1 here-in-before but Cap of DG Set 45/40/35 KVA
All as per ser item No 1 here-in-before but Cap of DG Set 30/25 KVA
Supply only Pre filter cartridge suitable for 750 KVA DG set (Set of Two)
Supply only Final filter cartridge suitable for 750 KVA DG set (Set of Two)
Supply only disel filter suitable for 320 kVA DG set (Set of Two)
Supply only disel filter suitable for 180/160 kVA DG set (Set of Two)
Supply only disel filter suitable for 100 kVA DG set (Set of Two)
Supply only disel filter suitable for 70/62.5 kVA DG set (Set of Two)
Supply only disel filter suitable for 45/40/35 KVA DG set
Supply only disel filter suitable for 30/25 KVA DG set
Supply only oil filter suitable for 750 kVA DG set (Set of Two)
Supply only oil filter suitable for 320 kVA DG set
Supply only oil filter suitable for 180/160 kVA DG set (Set of Two/One)
Supply only oil filter suitable for 100 kVA DG set (Set of Two/One)
Supply only oil filter suitable for 70/62.5 kVA DG set (Set of Two)
Supply only oil filter suitable for 45/40/35 KVA DG set
Supply only oil filter suitable for 30/25 KVA DG set
Supply only air filter safety suitable for 750 kVA DG set
Supply only air filter primary suitable for 750 kVA DG set (Set of Two)
Supply only air filter suitable for 320 kVA DG set (Set of Two)
Supply only air filter suitable for 180 /160 kVA DG set
Supply only air filter suitable for 100 kVA DG set
Supply only air filter suitable for 70/62.5 kVA DG set
Supply only air filter suitable for 45/40/35 KVA DG set
Supply only air filter suitable for 30/25 KVA DG set
M&L for drain out the old unsv engine oil from sump of DG sets & cleaning &n refilling with new engine oil 15 W 40 up to required level including top up complete all as specified and directed at site.
M&L for drain out old coolant from radiator and topup of best quality pre mixed coolants in radiator of any capacity DG set complete all as specified and directed at site.
M&L for top up of distilled water in DG set battery as per required level complete all as specified and directed at site.
Attending of emergency complaint in any breakdown of standby DG Sets/AMF panels up to 750 KVA DG set at any place in AF Stn Chabua,whenever required round the clock, and attend the complain supply with in 8 hrs after receipt of the complaint other wise a recovery of Rs. 500 / per day recovered from the contractor.
De-scaling of radiator assembly by carefully from the engine,transporting to civil workshop and removing the sediments,scales and rust etc by means of chemical cleaning,high pressure water washing and air cleaning, arresting the leakages by gas welding/soldering with suitable material, and re-assembling the same with new gaskets including replacement of radiator cap(whereever required) and transporting to the site, fixing to the engine for DG set of capcity 750 KVA and testing for satisfactory performance complete all as specified and directecd at site.
All as per ser item No 35 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 35 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 35 here-in-before but Cap of DG Set 100 KVA
All as per ser item No 35 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 35 here-in-before but Cap of DG Set 45/40/35 KVA
All as per ser item No 35 here-in-before but Cap of DG Set 30/25 KVA
Dismantling the defective fuel injectors & FIP from the engine and material and labour for repair/calibration of fuel injectors , nozzle repair with pressure check including replacement of barrel plunger,Nozzels,)element,dilevery valve, Injector,cups,'O' rings etc as per site requirement of 750 KVA DG set complete all as specified and directed at site.
All as per ser item No 42 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 42 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 42 here-in-before but Cap of DG Set 100 KVA
All as per ser item No 42 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 42 here-in-before but Cap of DG Set 45/40/35 KVA
All as per ser item No 42 here-in-before but Cap of DG Set 30/25 KVA
Supply and fixing in repair solenoid coil suitable for DG set of capacity 750 KVA complete all as specified and directed at site.
All as per ser item No 49 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 49 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 49 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 49 here-in-before but Cap of DG Set 45/40/35 KVA
All as per ser item No 49 here-in-before but Cap of DG Set 30/25 KVA
M& Labour in repair of self starter 24 volt ,dismantling from DG set of Cap 750 KVA and shifting to workshop and back for and including replacement of spare parts such as armature,housing bush,solonoid switch,pinion,pinion lock,rocker, rocker cap bush, frog, frog adjustment bolt,field coil,carbon brush,,armatur shat/comutator shaft ,adjusting bolt, centre plate bush,comutator fiber/steel washer carrying out following repair works ,
All as per ser item No 55 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 55 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 55 here-in-before but Cap of DG Set 100 KVA
M& Labour in repair of self starter 12 volt ,dismantling from DG set of Cap 70/62.5 KVA and shifting to workshop and back for and including replacement of spare parts such as armature,housing bush,solonoid switch,pinion,pinion lock,rocker, rocker cap bush, frog, frog adjustment bolt,field coil,carbon brush,,armatur shat/comutator shaft ,adjusting bolt, centre plate bush,comutator fiber/steel washer carrying out following repair works ,
All as per ser item No 59 here-in-before but Cap of DG Set 45/40/35 KVA
M&L for complete painting of 750 KVA DG set of and make with alternator ,base plate engine and complete canopy by using heat resistant paint with spray gun over existing surface as per existing colour code after taking out old paint ,dirt and dust from the DG set body, alternator and engine complete all as specified and directed by Engr-in-Charge.
All as per ser item No 61 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 61 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 61 here-in-before but Cap of DG Set 100 KVA
All as per ser item No 61 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 61 here-in-before but Cap of DG Set 45/40/35 KVA
All as per ser item No 61 here-in-before but Cap of DG Set 30/25 KVA
Dismantling the defective turbocharger suiatble for 750 kVA Dg Set and Repair/maint of Turbo charger suitable for 750 KVA Generator set of any ,make and type complete all as per specified and directed at site.
Dismantling the defective turbocharger suiatble for 320 KVA DG Set and Repair/maint of Turbo charger suitable for 320 KVA Generator set of any ,make and type complete all as per specified and directed at site.
Dismantling the defective turbocharger suiatble for 180/160 KVA DG Set and Repair/maint of Turbo charger suitable for 180/160 KVA Generator set of any ,make and type complete all as per specified and directed at site.
Dismantling the defective turbocharger suiatble for 125/100 KVA DG Set and Repair/maint of Turbo charger suitable for 100 KVA Generator set of any ,make and type complete all as per specified and directed at site.
Dismantling the defective water pump assembly and repair/maint of water pump assembly suitable for DG set of capacity 750 KVA complete all as specified and directed at site.
Dismantling the defective water pump assembly and repair/maint of water pump assembly suitable for DG set of capacity 320 KVA complete all as specified and directed at site.
Dismantling the defective water pump assembly and repair/maint of water pump assembly suitable for DG set of capacity 180/160 KVA complete all as specified and directed at site.
Dismantling the defective water pump assembly and repair/maint of water pump assembly suitable for DG set of capacity 45/40/35 KVA complete all as specified and directed at site.
M & L for rewinding of DG set alternator/Stator/Rotor coil /Rectifier Coil Unit of any capacity with super enemelled copper wire of existing gauge incluiding all connected insulating material, varnishing, replacement of carbon bushes including disconnection/dismantling of electrical connections, foundation bolts, pulling out of rotor with proper care and reinsulation of burnt out rotor/stator after rewinding work including re-assembling and testing on site including taking out alternator from AF Stn Chabua to auth workshop and after repair from workshop to site complete all as specified and directed at site.
M & L for repair/rewinding of 750 KVA DG set Battery charging Alternator 24 volt with super enamelled/ paper coated copper wire of existing gauge incluiding all connected insulating material such as separator etc, varnishing, replacement of carbon bushes including disconnection/dismantling of electrical connections, foundation bolts, pulling out and reinsulation of burnt out winding after rewinding work including re-assembling and testing complete all as directed.
All as per ser item No 77 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 77 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 77 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 77 here-in-before but Cap of DG Set 40/35 KVA
All as per ser item No 77 here-in-before but Cap of DG Set 30/25 KVA
Supply and fixing battery lead with stranded copper conductor of size 95/70 sqmm single core PVC insulated flexible 0.6 M long along with battery terminal for positive and stator terminal duly soldered all as directed.
Supply and fixing in replacement of battery lead with stranded copper conductor of size 95/70 sqmm single core PVC insulated flexible 0.6 M long along with battery terminal for negative and stator terminal duly soldered all as directed.
M&L in repair rewiring of DG control panel of 160 to 180 KVA DG Set as per existing circuit with proper size of lugs complete all as specified and as directed
M&L in repair rewiring of DG control panel of 40 to 70 KVA DG Set as per existing circuit with proper size of lugs complete all as specified and as directed
Supply and fixing SMPS electronic battery charger 24 v, 10 amps complete with all connecting accessories and connecting wire all as specified and as directed.
Supply and fixing SMPS electronic battery charger 12 v, 10 amps complete with all connecting accessories and connecting wire all as specified and as directed.
Supply and fixing oil temp sensor suitable for DG set of cap 750 KVA complete all as specified and directed at site.
All as per ser item No 89 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 89 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 89 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 89 here-in-before but Cap of DG Set 45/40/35 KVA
Supply and fix in replacement AVR suitable for 750 KVA DG Set complete complete all as specified and directed.
All as per ser item No 94 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 94 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 94 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 94 here-in-before but Cap of DG Set 45/40/35 KVA
M&L in replacement diesel pipe metal mesh types both side connecting arrangement of length as required on site suitable for 750 KVA DG Set complete all as specified and directed.
All as per ser item No 99 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 99 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 99 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 99 here-in-before but Cap of DG Set 45/40/35 KVA
Supply and fixing in repair actuator suitable for DG set of capacity 750 KVA complete all as specified and directed at site.
All as per ser item No 104 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 104 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 104 here-in-before but Cap of DG Set 70/62.5 KVA
Supply and fix in replacement of RRA suitable for 750 KVA DG Set complete complete all as specified and directed.
All as per ser item No 108 here-in-before but Cap of DG Set 320 KVA
All as per ser item No 108 here-in-before but Cap of DG Set 180/160 KVA
All as per ser item No 108 here-in-before but Cap of DG Set 70/62.5 KVA
All as per ser item No 108 here-in-before but Cap of DG Set 45/40/35 KVA
M&L for checking/Inspection/Maintenance and servicing complete including replacement of unserviceable spare parts of the DG Set( comparising of Engine/Alternator/Control panel) of the 180/160 KVA DG Set for smooth functioning as per OEM instructions including replacement of all type of gasket, all type of belt,door repair with sound proof spunch and or all as directed by Engr-in-Charge Checking (a) Checking & replacement of lubricating oil,(b) Repair & Replacement of all the nut,bolts of engine and alternator(c) Replacement of all belts and adjust the tension properly(d) and dismantling the cylinder head and assembly from DG Set , including overhauling of Engine and head shifting to authorised workshop for head & valve polishing and back for carrying out following repair and replacement of spares as mentioned below :- Note : (i) Spare parts to be measured and paid and separately
Kit cylinder Liner
Liner o ring
Piston
Piston ring
C.R.bearing
Valve
Complet gasket of DG Set
Complete fan belt of Dg Set
Valve Guide
Valve seat inlet
Valve seat exhaust
valve seal
Kit Turbo charging
Piston cooling nozzle
Piston connecting rod
Gear assembly
Governor pressure valve (hydraulic Governor)
Collet valve
Spring valve
Collar thrust
Kit injector
Barrel sleeve
M&L for checking/Inspection/Maintenance and servicing complete including replacement of unserviceable spare parts of the DG Set( comparising of Engine/Alternator/Control panel) of the 45/40/35 KVA DG Set for smooth functioning as per OEM instructions including replacement of all type of gasket, all type of belt,door repair with sound proof spunch and or all as directed by Engr-in-Charge Checking (a) Checking & replacement of lubricating oil,(b) Repair & Replacement of all the nut,bolts of engine and alternator(c) Replacement of all belts and adjust the tension properly(d) and dismantling the cylinder head and assembly from DG Set , including overhauling of Engine and head shifting to authorised workshop for head & valve polishing and back for carrying out following repair and replacement of spares as mentioned below :- Note : (i) Spare parts to be measured and paid and separately
Kit cylinder Liner
Liner o ring
Piston
Piston ring
C.R.bearing
Valve
Complet gasket of DG Set
Complete fan belt of Dg Set
Valve Guide
Valve seat inlet
Valve seat exhaust
valve seal
Kit Turbo charging
Piston cooling nozzle
Piston connecting rod
Gear assembly
Governor pressure valve (hydraulic Governor)
Collet valve
Spring valve
Collar thrust
Kit injector
Barrel sleeve
Supply and fix in replacement of bellow flexible suitable for 750 KVA DG Set set all as specified and directed at site.
Supply and fix in replacement of bellow flexible suitable for 160/180 KVA DG Set set all as specified and directed at site.
Supply and fix in replacement of bellow flexible suitable for 70/62.5 KVA DG Set set all as specified and directed at site.
Supply and fix in replacement of bellow flexible suitable for 45/40/35 KVA DG Set set all as specified and directed at site.
Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 750 kVA DG set all as specified and directed at site.
Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 320 kVA DG set all as specified and directed at site.
Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 180/160 kVA DG set all as specified and directed at site.
Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 70/62.5 kVA DG set all as specified and directed at site.
Supply and fix in replacement of engine Fan blade suitable for 750 kVA DG set all as specified and directed at site.
Supply and fix in replacement of engine Fan blade suitable for 320 kVA DG set all as specified and directed at site.
Supply and fix in replacement of engine Fan blade suitable for 180/160 kVA DG set all as specified and directed at site.
Supply and fix in replacement of thermostate valve suitable for 750 KVA DG Set complete all as specified and directed at site.
Supply and fix in replacement of thermostate valve suitable for 320 KVA DG Set complete all as specified and directed at site.
Supply and fix in replacement of thermostate valve suitable for 180/160 KVA DG Set complete all as specified and directed at site.
Supply and fix in replacement of thermostate valve suitable for 70/62.5 KVA DG Set complete all as specified and directed at site.
Supply and fixing in replacement of maintenance free battery with initially charged of capacity 90/100 AH, 12 volt complete all as specified and directec at site.
Supply and fixing in replacement of maintenance free battery with initially charged of capacity 150 AH, 12 volt complete all as specified and directec at site.
Supply and fixing in replacement of maintenance free battery with initially charged of capacity 180 AH, 12 volt complete all as specified and directec at site.
Servicing of AMF panel of DG Set 320 kVA by OEM i.e auth dealer of installed at AF Stn Chabua by cleaning the complete panel with suitable cleaning agennt,removing dust particles by using high speed blower and checking the controller relays,timer, contactors for proper functioning,replacing defective spare parts,replacement of defective wires of exixting size up to 2 mtr,tightening of all connections and applying jelly on contractors complete all as specified and directed by Engr-in-Charge Note : Spare parts required will be measured and paid separately as supply only but cost of small wire s shall be included in the quotated rates.
Supply AMF Relay procom
Supply only battery charger 24 Volt
CT coils 5/100
Servicing of AMF panel of DG Set 180/160 kVA by OEM i.e auth dealer of installed at AF Stn Chabua by cleaning the complete panel with suitable cleaning agennt,removing dust particles by using high speed blower and checking the controller relays,timer, contactors for proper functioning,replacing defective spare parts,replacement of defective wires of exixting size up to 2 mtr,tightening of all connections and applying jelly on contractors complete all as specified and directed by Engr-in-Charge Note : Spare parts required will be measured and paid separately as supply only but cost of small wire s shall be included in the quotated rates.
Supply AMF Relay procom
Supply only battery charger 24 Volt
CT coils 5/100
Servicing of AMF panel of DG Set 100 kVA by OEM i.e auth dealer of installed at AF Stn Chabua by cleaning the complete panel with suitable cleaning agennt,removing dust particles by using high speed blower and checking the controller relays,timer, contactors for proper functioning,replacing defective spare parts,replacement of defective wires of exixting size up to 2 mtr,tightening of all connections and applying jelly on contractors complete all as specified and directed by Engr-in-Charge Note : Spare parts required will be measured and paid separately as supply only but cost of small wire s shall be included in the quotated rates.
Supply AMF Relay procom
Supply only battery charger 24 Volt
CT coils 5/100
Servicing of AMF panel of DG Set 62.5 kVA by OEM i.e auth dealer of installed at AF Stn Chabua by cleaning the complete panel with suitable cleaning agennt,removing dust particles by using high speed blower and checking the controller relays,timer, contactors for proper functioning,replacing defective spare parts,replacement of defective wires of exixting size up to 2 mtr,tightening of all connections and applying jelly on contractors complete all as specified and directed by Engr-in-Charge Note : Spare parts required will be measured and paid separately as supply only but cost of small wire s shall be included in the quotated rates.
Supply AMF Relay procom
Supply only battery charger 24 Volt
CT coils 5/100
Supply and fix in replacement of radiator Cooling Fan pulley suitable for 750 kVA DG Set complete all as specified and directed at site.
Supply and fix in replacement of radiator Cooling Fan pulley suitable for 180/160 KVA DG Set complete all as specified and directed at site.
Supply and fix in replacement of engine mounting vibrating pad suitable for DG Set cap 180/160 KVA complete all as specified and directed at site.
Supply and fix in replacement of engine mounting vibrating pad suitable for DG Set cap 70/62.5 KVA complete all as specified and directed at site.
Supply and fixing in repair of 4 pole MCCB 400 Amp suitable for 160/180 KVA DG Set AMF Panels complete all as specified and directed at site.
Supply and fixing in repair of 4 pole MCCB 300 Amp suitable for 160/180 KVA DG Set AMF Panels complete all as specified and directed at site.
Supply and fixing in repair of 4 pole power contactors, suitable for 160/180 KVA DG Set AMF Panels complete all as specified and directed at site.
S & F in replacement of all type of 'V' belt suitable for 70/62.5 kVA DG Set complete all as directed by Engr-in -charge.
S & F in replacement of all type of 'V' belt suitable for 180/160 kVA DG Set complete all as directed by Engr-in -charge.
Supply and fix in replacement of all type of gasket / seal suitable for 125/100 kVA DG set all as specified and directed at site.
Supply and fixing in repair contactor suitable for 62.5 kVA DG Set AMF Panel complete all as specified and directed at site.
Supply and fixing in repair contactor coil suitable for 62.5 kVA DG Set AMF Panel complete all as specified and directed at site.
Supply and fix in replacement of Turbo charger suitable for 160/180 KVA Generator set of any ,make and type complete all as per specified and directed at site.
Supply and fix in replacement of water pump assembly suitable for existing DG set of capacity 70/62.5 KV complete all as specified and directed at site.
Supply and fix in replacement of four pole change over switch with advance neutral on load I-O-II, current rating 630 amps ,415 volts with open execution/ with enclosure complete all as specified and directed at site.
Supply and fix in replacement of four pole change over switch with advance neutral on load I-O-II, current rating 400 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site.
Supply and fix in replacement of four pole change over switch with advance neutral on load I-O-II, current rating 320/315 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site.
Supply and fix in replacement of four pole change over switch with advance neutral on load I-O-II, current rating 250 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site.
Supply and fix in replacement of four pole change over switch with advance neutral on load I-O-II, current rating 200 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site.
Supply and fix in replacement of four pole change over switch with advance neutral on load I-O-II, current rating 160 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site.
Supply and fix in replacement of four pole change over switch with advance neutral on load I-O-II, current rating 125 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site.
Supply and fix in replacement of four pole change over switch with advance neutral on load I-O-II, current rating 63 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site.
Supply and fix in replacement of engine control panel considting of ignition switch,water temperature gauge,VAF meter,push button,indication lamp etc suitable for DG set of capacity 62.5 KVA complete all as specified and directec at site
S & F in repair doors of 250 kVA DG Set including welding of defective portion and provision of fixing of new MS hinges/MS sheet of suitable size including replacement of all doors acoustic foam complete all as directed by Engr-in -charge.
S & F in repair doors of 180/160 kVA DG Set including welding of defective portion and provision of fixing of new MS hinges/MS sheet of suitable size including replacement of all doors acoustic foam complete all as directed by Engr-in -charge.
S & F in repair doors of 70/62.5 kVA DG Set including welding of defective portion and provision of fixing of new MS hinges/MS sheet of suitable size including replacement of all doors acoustic foam complete all as directed by Engr-in -charge.
S & F in repair doors of 45/40 kVA DG Set including welding of defective portion and provision of fixing of new MS hinges/MS sheet of suitable size including replacement of all doors acoustic foam complete all as directed by Engr-in -charge.
STANDARD ELECTRIC WINDERS (BID ID -3480993)
FREEZCON (BID ID -3480747)
AFTAB ENTERPRISES (BID ID -3482198)
S K ENTERPRISE (BID ID -3482601)
D N ENTERPRISE (BID ID -3481796)
M/S S.A.Electrics (BID ID -3481217)
M/S P R SINGH AND SONS (BID ID -3483076)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
GeneralPages.pdf
Tender Documents • 0.62 MB
BOQ_826924.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .