| 1 | L1₹11.6 LAccepted-AOC B 35 BLOCK 9 NEW TEKDI TOWNSHIP PO GONDEGAON DISTRICT NAGPUR 441404 | NAGPUR | MAHARASHTRA | 441404 | L1 | Accepted-AOC LOWEST BIDDER L1 | |
| 2 | L2₹14.0 L+₹2.5 L (21.5%)Rejected-Finance 40004093 BINDU KISAN SINGH WARD NO 4 GUJAR KHEDI SAONER NAGPUR 441107 | NAGPUR | MAHARASHTRA | 441107 | L2 | Rejected-Finance REJECTED |
Tender Value
₹16.1 L
EMD Value
₹20,200
Closing Date
8 Feb 2025, 6:00 pmClosed
STAFF OFFICER CIVIL NAGPUR AREA
OFFICE OF THE AREA GENERAL MANAGER NAGPUR AREA PO KASTURBA NAGAR JARIPATKA NAGPUR 440014
Providing 01 Nos of Tubewell including ground water tank with shed mear over head tank at Inder Colony of Kamptee Sub Area.
2025_WCL_326759_2
na3250-civ-e-tender 50-2024-25
Open Tender
Civil Works - Others
Item Rate
60 days
Kamptee Sub Area
AS PER NIT
3 documents required · 3 mandatory
₹20,200
17 Mar 2025
24 Jan 2025
10 Feb 2025
25 Jan 2025
8 Feb 2025
25 Jan 2025
24 Jan 2025 - 28 Jan 2025
Amount
Hydrological survey (water devining charges) including yield test consisiting of yield, visit of expert authorised team along with necessary instrument, conducting resistivity survey preparation and submission of yield test report and suggesting pump type, capacity,depth etc all complete as per instruction of I/C.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.All types of soil 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia having minimum wall thickness 5.00 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part l).150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:150 mm dia
Providing and fixing pair of wooden sleeper of size 1.0 x 0.30 x 0.20 m for supporting clamp etc all complete as per instruction of E/I.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Supplying, erecting, testing and commissioning of minimum three & above star rated submersible pumpset of 5.625 kW/7.5 HP or as per suitable discharge with 415 V, three phase, 50 Hz A.C. supply suitable for 150 mm dia. borewell with 50 to 330 lpm discharge at 169 to 18 m head & discharge & delivery pipe of size-50 mm dia. with a necessary H type clamps as per specification no. WP-SMP (pump should be operated for 07 days total run after commencement and should carry manufacturers warranty for minimum period of 01 year the pump should be prefarably of KSB/C.R.I/Pullan or as approved by E/I)
Providing fixing & lowering G.I pipe of medium with long socket/G.I fitting for tubewell etc al complete as per instruction of E/I. 50 mm dia.
Supplying, erecting, testing and commissioning of flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying and erecting control panel for 3 phase, 415 V, AC submersible/centrifugal pump set 7.5 to 10 hp consisting of DOL starter having relay range 13 to 21 amp spp combined amp meter/ volt meter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection, control panel should offer single phasing, phase reversal, phase in balance etc all complete as per instruction of E/I.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more
Filling available excavated earth (excluding rock) in trenches, plinth. sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
Neat cement punning
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Point wiring for light/fan/bell in 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification no. WG-PW/SW
Supplying and erecting shockproof 3 pin plug socket 16A with porcelain base/ flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5mm thick laminate with S M screws and duly connected.
Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking /inside pole/bus bars or any other places. as per specification no. WG-MA/BW
Supplying, erecting, testing and commissioning of minimum three & above star rated centrifugal water pump (monoblock), 415 V, three phase, 50 Hz, A.C. supply of 5.625 kW/7.5 HP with discharge of 780/170 lpm for head of 33/54 m and 80 mm suction/65 mm delivery pipe on provided CC foundation as per specification no. WP-CGP.
Finishing walls with Acrylic Smooth exterior paint of required shade .New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm
Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP
Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF.
Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1400
Supplying & erecting ready to use Retrofit T8 LED, 18 / 20 watt tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary as per specification No. FG-LP/RET.
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways/12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB.
Supplying, erecting & marking DP MCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
Supplying, erecting & marking DP MCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
G. I. PIPES Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.B)MEDIUM 80 mm. ( 8.64 kg./m )
G. I. PIPES Providing ISI mark G.I. pipe of following class and dia. excluding GST levied by GOI & GOM in all respect, inspection charges, transportation to stores, etc. complete as per IS-1239/2004. Note : One coupler shall be provided with each full length of pipe cost of which is included in rates below.B) MEDIUM 100 mm. ( 12.40 kg./m )
Providing and supplying ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Reflux valves as per I.S.5312 Part I (1984)Without by pass arrangement -PN -1.100 mm
Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Sluice valves - PN -1 (Without by pass)100 mm.
Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves/non-return valve including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)100 mm.
Providing and fixing G.I flange 100/110 mm dia with nut and bolts etc all complete as per instruction of E/I.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Total impact of GST for the purpose of CTC
SAI TRADERS (BID ID -1124277)
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_338695.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .