Loading…
Loading…
Tender Value
₹4.7 Cr
EMD Value
₹2.4 L
Closing Date
8 Apr 2026, 5:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
MR Yognarayan sahu(DFLT)
CE(Ambikapur)
CONSTRUCTION OF RAJPUR-PRATAPPUR ROAD K.M. 11 TO KUNDI-KARWA APPROACH ROAD VIA PAHADPARA ROAD LENGTH 3.10 K.M. DISTT. BALRAMPUR-RAMANUJGANJ (C.G.)
187345
NIT No. 1098/TC/EinC/PWD/25-26
RESTRICTED TENDER
WORKS
4 days
CE(Ambikapur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
7 documents required · 7 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CE(Ambikapur)
PWD Circle, Ambikapur
Division Ramanujganj
120
04
No
0
187345
8 Apr, 2026 5:00:00 PM IST
13 Apr, 2026 10:00:00 AM IST
18 Mar, 2026 5:00:00 PM IST
NIT No. 1098/TC/EinC/PWD/25-26
CONSTRUCTION OF RAJPUR-PRATAPPUR ROAD K.M. 11 TO KUNDI-KARWA APPROACH ROAD VIA PAHADPARA ROAD LENGTH 3.10 K.M. DISTT. BALRAMPUR-RAMANUJGANJ (C.G.)
235160.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
47032000.00
2
10 Apr, 2026 5:00:00 PM IST
47032000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
20d 23h 44m
7 documents required · 6 mandatory · 1 optional
₹0
₹2.4 L
18 Mar 2026
18 Mar 2026
13 Apr 2026
18 Mar 2026
8 Apr 2026
18 Mar 2026
10 Apr 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and es girth up to 300 mm, removal of stumps of trees cut lier and disposal of unserviceable materials and stacking of serviceable terial tobe used or auctioned up to a lead of 1000 meters cluding removal and disposal of top ic soil not exceeding 150 mm in thickness if required and as per relevant lauses of ction- 200.
Compacting Original Ground Compacting Original Ground supporting embankment Loosening, leveling and compacting original ground to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at O.M.C. and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction.
Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300.
Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankment with approved materials having C.B.R.>5 (unless specified otherwise in the contract) deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method (with Mechanically crushed stone only) For Lower Sub-base with Grading-III Material
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)
Prime coat (Providing and applying primer coat with oil based bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per clause 502. on WBM/WMM surface @0.85 Kg/sqm.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. Granular surfaces treated with primes @ 0.30 kg /Sqm
Bituminous Macadam (Providing and laying bituminous macadam as per clause 504 with mixed prepared in minimum 40-60 TPH capacity hot mix plant usin g crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction)
Close Graded Premix Surfacing/Mixed Seal Surfacing (Mechanical means using minimum 40-60 TPH capacity of HMP. Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness using bitumen to the required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to required level and grade, complete as per clause 508) With mechanical paver finisher Type B ( 13.2 mm to 0.09 mm size aggregates )
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new nstruction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98-2011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to imum 450 mm in case of double and triple row ducts ,joints to be made leak proof, invert level of duct to be above gher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. Single row for one utility service
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 600 mm dia
Retro- reflectrorized Traffic signs (Providing and fixing of retro-reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of Micro prismatic grade type reflective sheeting vide clause 801.3, fixed over aluminum sheeting, 1.5 mm thick supported on a mild steel frame of size 40 x 40 x 5 mm and mild steel angle iron post 75 mm x75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing) Made of Class -A High Intensity Super Engineering Grade Sheeting of Type II (for ODR &Village Road) With Aluminum Sheeting of 2 mm thickness 600 mm equilateral triangle
600 mm circular
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorized sign as per IRC :67-2012 made of retro-reflective type sheeting and vide ause 801.3, fixed over aluminum sheeting, 2 mm thick with area exceeding 0.9 sqm and fixed on a mild steel frame of size 40 x 40 x 5 mm supported on 2 Nos. mild steel angle iron posts of size 75 mm x 75 mm x 6 firmly fixed to the ound with M 15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing) C Made of class - A High intensity Micro prismatic grade Sheeting of Type 1 (for ODR &Village Road)
Kilo Meter Stone (Reinforced cement concrete M15 grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Ordinary Kilometer stone (Precast)
Hectometer stone (Precast)
Providing and fixing guard stones 200 x 200 x 900 mm made of precast RCC M-20 grade fixed at 300 mm into the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400 mm and given two coats of paint with white and black bands including excavation.
Providing & Fixing tree studs in Square/ Round shape of 4” side/diameter made of 2 mm aluminum substrate ming to IS:736 -Material Designation, 24345 or 1900) end ective surface of High Intensity grade as specified in section 801.3 of MORT&H duly treated with HLVA and fixing the same th four Nos. high strength nails confirming to 1S:1367 on trees at site each.
Construction of RCC open drain Construction of RCC open drain 0.60m x 0.60m inside dimension lined with 120 mm thick RCC M-20 walls, 120 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 8 mm dia horizontal bars @ 150 mm c/c and L-shaped 8 mm dia vertical bars @ 150 mm c/c (L= 800 mm) including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications.
Construction of RCC Drain/Cover/Chamber Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth
Plain cement concrete complete as per drawing and Technical Specifications PCC Grade M 15
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete. Ordinary soil Upto 3 m depth
Add extra 20% in the rates of above items for dewatering (Assessment of dewatering shall be made as per site condition )
Ordinary Rock (Not Required Blasting) Upto 3 m depth
Add extra 20% in the rates of above items for dewatering (Assessment of dewatering shall be made as per site condition )
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications Using concrete Mixer P.C.C grade M 15
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Providing and laying Plain/Reinforced cement concrete in sub - structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags). Upto 5m Height Using Concrete Mixture P.C.C. grade M 15
Supplying, fitting and placing HSD (High Strength Deformed Steel) bars reinforcement in sub - structure complete as per drawing and technical specifications section 1600 and 2200.
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC pipe, extending through the full width of the structure with slope of 1 V: 20 H towards drawing face. Complete as per drawing and Technical specifications section 2706 and 2200.
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MORT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications 710.1.4 of I.R.C. 78 and 2200
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200. Granular material
Furnishing and Placing Reinforced/Prestressed cement concrete in super - structure as per drawing and Technical Specification sections 1500, 1600 and 1700 (Newly laid concrete shall be covered by gunny bags). R.C.C. Grade M 25 For Solid Slab Super Structure Height upto 5m
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in super - structure complete as per drawing and technical specifications
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications as per relevant clause of section 2700.
Providing and fixing in position 20 mm thick premoulded joint filler ( 12 m long x 30 cm deep ) in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications.
Providing and filling joint sealing compound ( 12 m long x 100 mm wide x 10 mm deep recess) as per drawings and technical specifications with coarse sand and 6% bitumen by weight
Drainage Spouts complete as per drawing and Technical specifications of section 2705
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 1000 mm dia
UOM Name
Percentage
Per mile
Per Diem Rate
MAN DAYS
Siemens Per meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.07 MB
4355648977090759701_152305_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
6550909912944831901_187345_Form A.doc
NIT • 0.15 MB
4310059743873899002_187345_NIT.doc
NIT • 0.36 MB
9008141592657844824_187345_Notice.docx
NIT • 0.04 MB
2005699552325280962_187345_BOQ.xlsx
BOQ • 0.04 MB
Download all tender documents and submit your bid