| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.7 L+₹62,176 (5.63%)Rejected-Finance 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance OTHER THAN L1. | |
| 3 | L3₹12.2 L+₹1.2 L (10.8%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L3 | Rejected-Finance OTHER THAN L1. | |
| 4 | L4₹14.8 L+₹3.7 L (33.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1. | |
| 5 | L5₹15.9 L+₹4.9 L (44.2%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L5 | Rejected-Finance OTHER THAN L1. |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS, BB CANTT SRINAGAR
REPAIR/ MAINT/ REPLACMENT OF LT NETWORK AND ALLIED WORKS UNDER AGE E/M OF GE 864 EWS AT BB CANTT, SRINAGAR
2022_MES_537729_1
864/WS-30/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE 864 EWS, BB CANTT SRINAGAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹40,000
Yes
11 Oct 2022
13 Jul 2022
12 Aug 2022
13 Jul 2022
10 Aug 2022
27 Jul 2022
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cable/pipes etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Ditto all as per serial item No. 1.00 described here-in-before but exceeding 1.5 metr in depth and not exceeding 3.0 metre depth
M&L for dry sand cushioning to under ground cable 8 cm thick before laying and 15 cm thick after laying and stretching the cables complete all as specified and directed. Note :- 1. Dry fine sand of best available quality shall only be used. 2. Punned down thickness shall only be measured and paid.
Supply and lay Sub class 'B' old size bricks well burnt as covering to under ground cables, laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable, complete all as specified and directed.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in soils complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supplying, laying, jointing and testing in replacement of u/s LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable, laid in trenches/ ducts or fixed to poles/ walls or laid under roads/ paths/ drains/ culverts duly encased in galvanised steel pipe of suitable sizes complete all as specified and directed of following sizes:-
240 Sqmm x 3.5 core
120 Sqmm x 3.5 core
95 Sqmm x 3.5 core
70 Sqmm x 3.5 core
50 Sqmm x 3.5 core
35 Sqmm x 3.5 core
25 Sqmm x 3.5 core
16 Sqmm x 4 core
Supply, fixing, connecting and testing in replacement of u/s MCCBs in existing LT panel box / feeder pillar boxes (KIOSK) of capacity 630 Amps 4 pole breaking capacity 36 KA with thermal as well as magnetic balance adjustable type trip setting complete all as specified and directed.
Ditto all as per serial item No. 8.00 described here-in-before but 400 Amps, 4 pole and 36 KA
Ditto all as per serial item No. 8.00 described here-in-before but 350/315 Amps, 3 pole and 25 KA
Ditto all as per serial item No. 8.00 described here-in-before but 250 Amps, 3 pole and 25 KA
Ditto all as per serial item No. 8.00 described here-in-before but 200 Amps, 3 pole and 25 KA
Ditto all as per serial item No. 8.00 described here-in-before but 160 Amps, 3 pole and 25 KA
Ditto as Srl No. 08 but 100Amps, 3 pole and 16 KA
Ditto all as per serial item No. 8.00 described here-in-before but 63 Amps, 3 pole and 16 KA
Supply and fixing in replacement galvanised iron pipes 80 mm bore light grade with all fittings for cable protection, laid under road/under culvert/drain/pole/wall complete with clamps made out of 50 x 6 mm thick MS flat, nuts, bolt of appropriate size including closing of ends with soft wooden wedge duly preformed with bitumenous material complete all as specified and directed.
Supply and fixing in replacement galvanised iron pipes 50 mm bore light grade with all fittings for cable protection, laid under road/under culvert/drain/ pole/wall complete with clamps made out of 50 x 6 mm thick MS flat, nuts, bolt of appropriate size including closing of ends with soft wooden wedge duly preformed with bitumenous material complete all as specified and directed.
M&L for plain cement concrete (1:4:8), type D2, (using 40 mm graded crushed stone aggregates) as in foundation filling and mass concrete for poles/stays, complete all as specified and directed.
M&L for plain cement concrete (1:2:4), type B1, (using 20 mm graded crushed stone aggregates) as in foundation, filling and mass concrete and copings and the like including necessary form work complete all as specified and directed.
M&L for preparation of existing old surface of steel tubular poles of 09 Mtr / 11 Mtr long and applying one coat of aluminium paint on the surfaces of steel tubular pole and painting black and white strips 04 Nos (each strip of 30 cm height) with synthetic enamel paint of black and white colour round the steel tubular pole alternatively from the bottom of the pole also incl numbering of pole complete all as specified and directed.
Dismantling and setting aside the pole of PCC/ Steel tubular pole 9 Mtr long complete all as specified and directed.
Fixing only steel tubular pole (retrieved form BOQ item No. 21.00 described here-in- before any type (9 Mtr long) complete all as specified and directed. Note:- Excavation, earthwork and PCC shall be measured and paid seperately under relevant items
Supply and erecting in vertical position steel tubular swaged pole type 410 SP-31 (9metre long) with 300mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5M from ground level/coping complete all as specified and directed.
Supply, fixing, commissioning and testing ACSR conductor in replacement of any size on existing LT pole including copper binding wire or aluminium tab, complete all as specified and directed.
Restretching of LT ACSR conductor and GI wire of any size and on any type of poles including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line spans, line separators, cross arms on poles complete all as specified and directed.
M&L for Cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, including dismantling old mild steel complete all as specified and directed.
S&F in Repair/Replacement of damaged service cable incluing supply and fixing 1100 volt grade alluminium solid conductor cable with PVC armoured tape and overall PVC sheathed 6 sqmm 2 core nominal cross section in service connction complete all as specified and directed.
S&F in Repair/Replacement of damaged service cable incluing supply and fixing 1100 volt grade alluminium solid conductor cable with PVC tape armoured tape and overall PVC sheathed 10 sqmm 2 core nominal cross section in service connction complete all as specified.
Cutting and trimming of tree branches to clear the over head lines in the arc of HT/ LT over head lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed. Note: All tools required for the job should be arranged by the contractor with in the overall cost quoted in the unit rate.
Supply and fix in replacement busbar chamber wall mounted 8 way 250 Amps cubical type complete all as specified and directed.
Supply and fix in replacement busbar chamber wall mounted 8 way up to 100 Amps cubical type complete all as specified and directed.
Supply and fix in replacement busbar chamber wall mounted 8 way 400 Amps cubical type complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connecting to the galvanised iron earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore medium grade GI pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, layers of common salt and charcoal filling, test point made out of 40mmx6mm flat iron with fixing arrangement funnel, wire mesh and earth work in hard/ dense soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electircal plate No. 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
Supply and fixing in replacement Off Load / On load change over switch in sheet metal enclousure 4 of pole of capacity 63 Amp complete all as specified and directed.
Supply and fixing in replacement of automatic transfer switch / automatic changover switch 4 pole, 50Hz, 415V, automatic/ manual with complete protection of capacity 160 Amps with sheet metal enclosure complete all as specified and directed.
Supply and fixing in replacement Off Load / On load change over switch in sheet metal enclousure 4 of pole of capacity 320 Amp complete all as specified and directed.
M/S TAHIRA ENTERPRISES
VEDA INFRASTRUCTURE
M/S MAS Electricals
M/S Sky Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .