Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.8 L+₹62,835 (1.60%)Rejected-AOC 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-AOC Lowest Bidder is JAMUNA CONSTRUCTION AND GENERAL ORDER SUPPLIER | |
| 3 | L3₹39.9 L+₹69,114 (1.76%)Rejected-AOC NOT AVAILABLE | L3 | Rejected-AOC Lowest Bidder is JAMUNA CONSTRUCTION AND GENERAL ORDER SUPPLIER | |
| 4 | L4₹40.1 L+₹92,526 (2.36%)Rejected-AOC N A | NA | NA | 121004 | L4 | Rejected-AOC Lowest Bidder is JAMUNA CONSTRUCTION AND GENERAL ORDER SUPPLIER | |
| 5 | L5₹40.9 L+₹1.7 L (4.29%)Rejected-AOC PEMASAR ROAD WARD NO 04 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L5 | Rejected-AOC Lowest Bidder is JAMUNA CONSTRUCTION AND GENERAL ORDER SUPPLIER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
26 Nov 2019, 6:00 pmClosed
Col Rajesh Dwivedi
CWE Bikaner Mil Stn Bikaner
Provn of special repair to building No P2 P3 and T142 1 to 4 JCO Md Accn at Military Station Bikaner under GE N Bikaner
2019_MES_295016_1
CWE BKN TOKEN 22 of 2019-2020
Open Tender
Civil Works
Item Rate
150 days
Bikaner
The firms not enlisted with MES shall meet the enlistment criteria of D class MES contractors category ai iewith regard to having satisfactorily completed requisite value work
7 documents required · 7 mandatory
₹500
GE NORTH Bikaner
₹1 L
Yes
1 Feb 2020
5 Nov 2019
28 Nov 2019
5 Nov 2019
26 Nov 2019
20 Nov 2019
5 Nov 2019 - 14 Nov 2019
Amount
Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified & as directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) all as specified & as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Dismantling of stone slabs in roofs, suspended floors, chajjas, landings, etc., any description, any thickness, jointed in any mortar, complete all as specified & as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed.
Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed.
Taking down shutters (including fittings & fixtures) of any description exc 1 Sqm and not exc. 2 Sqm each, complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good complete all as specified and as directed.
Taking down old rusted & damaged steel windows/ventilators of any description and of any type & size with guard bars / grill including cutting holes for hold fasts & making good the disturbed portion complete all as specified & as directed.
Taking down old rusted & damaged steel windows/ventilators of any description and of any type & size without guard bars / grill including cutting holes for hold fasts & making good the disturbed portion complete all as specified & as directed.
Dismantling of cast iron, wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement.
M&L for PCC 1:3:6 type C0 (using 12.5mm graded crushed stone aggregate) as in filling up chowkat/frame hollows and similar works complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately under respective item of this Schedule.
M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like complete all as specified & as directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
Supply only integral liquid water proofing compound (ISI marked).
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with old size Fly Ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M&L for 40 to 50mm thick sand stone slab in sunshades, chajjas, shelves, cills, landings, cover stones, templates etc not exc 2m in length, punched dressed on face and along exposed edges, self faced on the other side and set and pointed in cement mortar 1:4 complete all as specified and as directed.
M&L for Jodhpur stone roof slabs, self faced 7.5cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in cement mortar 1:6 complete all as specified & as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & as directed.
Formwork to edges of concrete flats, roofs, floors etc and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces complete all as specified & as directed.
Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same opening including easing and adjusting of shutter as required including renewal of unserviceable screws all as directed.
Supply and fixing factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & as directed.
Supply and fixing factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24(a) of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & as directed.
S&F factory made 25mm thick flush shutter, solid core construction, with block board core and plywood face panels, both faces covered with decorative face veneer with lipping to match complete all as specified and as directed.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour single piece extruded PVC profile reinforced with MS square tube in opening as per specifications complete all as specified and as directed..
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with plain colour single piece extruded PVC profile ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour single piece extruded PVC profile for top rail lock rail bottom rail on either side and as gap insert for Top rail and bottom rail paneling of plain colour PVC sheet to fitted on the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and as directed..
M&L for 19mm thick Particle board (ISI marked), medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work/hinges as in cupboard shutters, shelves, Kitchen cabinets etc with & including necessary 19mm wide & 6mm thick Teak wood beading / edging / lipping fixed with nails to particle board complete all as specified & as directed.
S&F butt hinges of size 100mm medium weight, cold rolled mild steel (ISI marked) including welding to angle iron frame where required complete all as specified and as directed.
S&F butt hinges of size 100mm extruded aluminium alloy with galvanized mild steel hinge pin, anodized type B-21 complete all as specified.
S&F 150 mm long mild steel barrel tower bolts, stove enameled black with bright bolts and fixed complete all as specified.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified.
S&F mild steel pressed handle, 150 mm size, oval type, stove enameled black complete all as specified.
S&F aluminium handle, 150mm size, cast type, anodized (ISI marked) complete all as specified.
Supply & fixing hasp and staple of size 100mm aluminium anodized safety type with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified.
S&F 250 mm long mild steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified & as directed.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified & as directed.
S&F mild steel helical door spring 300mm ordinary rat tail rod pattern spring including roller and roller plate, welded to steel frame, including making suitable cut out in wall and making good in CM 1:4 complete all as specified & as directed.
S&F 75mm long aluminium anodized floor door stopper double legged with rubber shoe/boot, fixed to bottom rail of door shutter complete all as specified & as directed.
S&F in repairs mild steel chromium plated tubular curtain/drapery rod 19mm dia (in lengths as directed) with & including pair of projecting type fancy mild steel chromium plated brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.
S&F rolled mild steel as in Joist, channel, angle or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length directed) and similar work conforming to Grade E-250 quality `A’ all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
M&L for mild steel TMT bars 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
S&F factory made pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, complete as specified & as directed.
S&F factory made pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, complete as specified & as directed.
S&F mild steel framed work such as framework of water tanks, ladders, railings and similar work conforming to Grade E-165 (Fe 290) including necessary welding etc complete all as specified & as directed.
S&F factory made steel ventilator with top hung shutter including hinges, steel peg stay, handle complete all as specified & as directed.
S&F factory fabricated pressed steel frame/box windows, ventilators with glazed and fly proof shutters provided to size and dimensions as specified & shown on drawing No. BTD-888R Sheet No. 1/5 to 5/5 & BTD-889 Sheet No. 1/4 to 4/4 with & including MS grill, MS fillets, pintol hinges, tower bolts, MS handles, peg stays, MS lugs, locking arrangement, dash through bolt where required, etc complete all as specified & as directed. Notes : (i) PCC for filling in frames, glass, wire gauge and painting shall be measured & paid for separately under respective items. Provision of all other items as shown & specified on drawings shall deemed to be included in quoted rate of this item. (ii) The quoted rate shall deemed to include provision of cutting holes of suitable depth in walls for inserting lugs etc and making good dismantled portion in PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate and CM (1:3).
Dismantling of brick tiles or terracing tiles single layer on roofs, complete all as specified and as directed.
Demolition of lime concrete of any description over roof, complete all as specified and as directed.
M&L for 10mm thick plaster (screed bed) over roof slab in CM 1:4, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and as directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for applying evenly a tack coat of industrial bitumen 85/25 grade at the rate of 1.20 Kg per sqm including cleaning surfaces, complete all as specified & as directed.
M&L for 150 micron heavy duty Polythene film (White) over roof slab and the like, complete all as directed.
M&L for Lime concrete terracing as specified in roof complete all as specified & as directed.
M&L for 40mm thick brick tiles, joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement, laid on roof over & including 20mm thick screed bed in cement & sand mortar 1:6, complete all as specified & as directed.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even, complete all as specified and as directed.
M&L for 75 mm thick PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in flooring, leveling course, etc, surface finished fair and even, complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in flooring, leveling course, etc, surface finished fair and even, complete all as specified and as directed.
M&L for 20 to 25mm thick machine cut Kota stone slab in single piece as in treads/landings of stair case & the like, laid over & including screed bed or bedding layer of 15mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified. Note : The nosing of treads/landings shall be made full round with two parallel grooves of 3mmx3mm and rate quoted shall deemed to include this provision.
M&L for 18 to 20mm thick machine cut Kota stone slab in single piece as in risers of stair case & the like, laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for glazed ceramic tiles (coloured) 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for 18 to 20mm thick Granite (of any type) machine cut slab of approved shade (table rubbed and polished) with true & uniform joints as in cooking platform & similar works and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed (bedding layer) in CM 1:4 with cement slurry @ 3 Kg/Sqm complete all as specified & as directed. Note : The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.
M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished even and smooth without using extra cement complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for factory made 60mm thick machine pressed precast cement concrete interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & as directed. Note : Shape of paver blocks shall be as approved by the GE.
M&L for factory made 60mm thick machine pressed precast cement concrete coloured designer polished (reflecting type) interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment with coloured top casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & as directed. Note : Shape & colour of paver blocks shall be as approved by the GE.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:6 on surfaces other than fair face of brick work of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished fair & even complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on surfaces other than fair face of brick work of walls, finished fair & even complete all as specified.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
Raking out joints/pointing to stone slab or precast concrete slab floor, any description, laid flat, work built in cement or cement lime mortar, complete all as specified & as directed .
M&L for flush pointing in cement mortar 1:3 to self faced / rough dressed stone slab or precast concrete slab floors, any description, laid flat, complete all as specified & as directed.
M&L for preparation of old surfaces (plastered or unplastered) of ceilings including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of white wash complete all as specified & as directed.
M&L for preparation of old surfaces (plastered or unplastered) of ceilings including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying two coats of white wash complete all as specified & as directed.
M&L for preparation of newly plastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty complete all as specified & as directed.
M&L for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil emulsion distemper (OBD) of approved shade/tint complete all as specified & as directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty on walls complete all as specified & as directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified.
M&L for preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint of approved shade/tint complete all as specified & as directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint on walls all as specified and as directed.
S&F 3mm thick figured glass pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified & as directed.
S&F 4mm thick sheet glass ordinary quality as in glazing to steel windows etc, not exc 0.5 sqm in each pane, complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and directed including taking up or down old unserviceable steel water tubing and connections of 15mm bore.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and directed including taking up or down old unserviceable steel water tubing and connections of 20mm bore.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing and making good, cutting not exc 10 cm girth in brick walls, complete all as specified & as directed.
Disconnecting & taking down the existing unserviceable water tank with ball valve and Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20mm bore (minimum weight 210 gms) complete all as specified and as directed.
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, complete all as specified and as directed.
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified & as directed.
S&F in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed.
S&F sink with drainage board made of stainless steel 1mm thick for Kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to brick wall, connecting union to pipe, overall minimum size 915mm x 460 mm with bowl size 410mm x 330mm x160 mm including 40mm dia waste pipe of polythelene of low or high density, 40mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete all as specified and as directed including taking down old unserviceable vitreous china sink with fittings.
S&F in repairs PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified & as directed.
S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified & as directed.
S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & as directed.
S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & as directed.
S&F in repairs 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified & as directed.
S&F in repairs 20mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified & as directed.
S&F in repairs 15mm bore Stop valve, fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F in repairs 15mm bore Angle stop valve, fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed.
S&F in repairs brass chromium plated basin mixer for mixing hot & cold water screwed down for iron pipe of 15mm bore complete all as specified and as directed.
S&F in repairs brass chromium plated wall mixer for mixing hot & cold water screwed down for iron pipe of 15mm bore all as specified and as directed.
S&F in repairs brass chromium plated shower rose 65mm size with swivel joint type including fixing to steel pipe of 15mm bore or union complete all as specified.
S&F in repairs tubular towel rail, stainless steel, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified and as directed.
S&F in repairs corner glass shelf (set of three - 200mm x 3) fixed on wall with PVC rawl plug & cadmium plated brass screws. Make : Parryware / Jaquar / Marc / Kingston / Somany / Ess Ess / Sieco / Kohler / Hindware / Prayag / Parko
S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with aluminium alloy brackets and guard rail 60cm long fixed on wall with PVC rawl plug & cadmium plated brass screws, complete all as specified and as directed.
S&F in repair Mirror cabinet (PTMT) of size 450mm x 350mm with 5mm thick high quality mirror, seamless finish, light weight, high strength, fixed on wall with cadmium plated brass screws, complete all as specified & as directed. Make :- Prayag (Cat Part No. 557) or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs brass chromium plated soap dish with flange fixed on wall with PVC rawl plug & cadmium plated brass screws. Make : Cat Part No T6403A1 of Parryware or equivalent of Jaquar / Marc / Kingston / Somany / Ess Ess / Sieco / Kohler / Hindware / Prayag / Parko
S&F in repairs stainless steel peg set of six of standard size (not less than 300mm long) as approved fixed to wall with two rawl plugs and chromium plated brass screws complete all as directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified & as directed including dismantling & taking down old unserviceable 110mm bore PVC pipe with fittings.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified & as directed including dismantling & taking down old unserviceable 75mm bore PVC pipe with fittings.
S&F 110mm bore PVC (SWR) bend, any radius with oval access door complete all as specified & as directed.
S&F 75mm bore PVC (SWR) bend, any radius with oval access door complete all as specified & as directed.
S&F 110mm bore PVC (SWR) branch piece, single (single ‘Y’) equal or unequal with access door complete all as specified & as directed.
S&F 75mm bore PVC (SWR) branch piece, single (single ‘Y’) equal or unequal with access door complete all as specified & as directed.
S&F 110mm bore PVC (SWR) branch piece, double (double ‘Y’) equal or unequal with access door, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) branch piece, double (double ‘Y’) equal or unequal with access door, complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) junction single (single ‘T’), equal or unequal with access door, complete all as specified and as directed.
S&F 75 mm bore PVC (SWR) junction single (single ‘T’), equal or unequal with access door, complete all as specified and as directed.
S&F 110mm PVC (SWR) WC connector with lip ring complete all as specified & as directed.
S&F 110mm bore PVC (SWR) vent cowl complete all as specified & as directed.
S&F in repairs PVC (SWR) floor trap plain with PTMT grating including jointing with solvent cement, diameter of outlet 75mm, complete all as specified & as directed.
Demolition and breaking up 150mm bore SGSW/RCC/AC drain pipes set in cement mortar including PCC haunching and bedding, complete all as specified and as directed.
S&F salt glazed stone ware drain pipes of 150mm bore, Class ‘SP 2’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in bedding to SGSW drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and as directed.
M&L for cutting into existing manholes/Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1, reforming benching as required and finishing surface even & smooth for 150mm bore pipe complete all as specified and as directed.
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
All as per serial item No. 143 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches.
All as per serial item No. 143 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No. 143 here-in-before but for one light point controlled by two, two way switches.
All as per serial item No. 143 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, two way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F bell push, flush type, 5 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 3 pin (2 in 1, with 2 pin outlet also), 5/6 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch socket combination, 5 in 1, 5 and 16 Amps, flush type, 230 Volts, ISI marked, complete all as specified and as directed .
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
S&F 9 Watt LED Bulb (Non-dimmable) of Standard / Universal size, Base - B22, Power Factor > 0.90, Lamp Efficiency > 80%,, Color Temperature - 3000 K, Lumen output - 900 lm, Colour Rendering Index (CRI) > 70, Warm white (WW) / Cool Day Light (CDL), 230 V, 50 Hz AC, ISI marked, complete all as specified and as directed.
S&F electronic fan regulator, flush type, stepped type with 5 step control, 230 Volts, 150 Watt, including making hole in sheet top cover and connecting up, ISI marked, complete all as specified and as directed.
Supply and fixing Bell ‘Ding Dong’ / ‘Multi Music’ Type, AC, 230 Volts, ISI marked, complete all as specified and as directed.
S&F bulk head energy efficient LED light fitting, 1x10 Watt, 230 Volts, surface mounted, comprising of high brightness LEDs, IP-65 protection, with & including all standard accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make : Havells Cat Part No. RUGBYNEONFT10WLED860SSYM TOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F energy efficient decorative ultra slim LED light fitting, 1x18/20 Watt, 230 Volts, Day Cool light, batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make : Havells Cat Part No. LUMILINEBS18WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F sheet metal enclosure for distribution boards flushed in wall, double door type, suitable for fixing MCBs/MCCBs, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, TPN, vertical load line, 4 way, suitable for 3 Pole / 4 Pole ‘A’ frame MCCB, fitted with and including following accessories, complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type & capacity :- (a) MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type – 01 No (b) MCB, 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve – 04 Nos Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, fixed in repairs, complete all as specified and as directed.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts, fixed in repairs, complete all as specified and as directed.
S&F MCB, 6 to 30 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
S&F MCB, 5 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, fixed in repairs, complete all as specified and as directed.
M&L for taking down carefully existing serviceable ceiling fan with down rod / exhaust fan of any sweep and re-fixing / hanging the same after proper cleaning and connecting up with and including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto ceiling rose, complete all as specified and as directed.
M&L for carefully disconnecting electric & water connections and taking down existing serviceable Geyser (water storage type) of capacity 25/50 litre vertical type and re-fixing the same with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of suitable size but not less than 10mm dia 125mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface as original and re-connecting electric & water connections, complete all as directed.
M&L for painting of exposed steel & iron surfaces of existing electric energy meter panel box of any size with two coats of synthetic enamel paint of approved tint including preparation of old painted surfaces and marking MES/Serial number, Volt, etc on panel box with white thick synthetic enamel paint including cleaning of perspex/glass fitted to box using suitable cleaning chemical complete all as specified & as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete including dismantling & taking down old unserviceable sub main wiring. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete including dismantling & taking down old unserviceable sub main wiring. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 3 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :- (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe with clamps. Note :- Excavation & earthwork shall be measured & paid for separately.
Beenu Co. Company
durga construction company
N.K. CONSTRUCTION COMPANY
SUBHAM ENTERPRISES
M/S ASHRAFI CONSTRUCTION CO
ALPHA ENGINEERING COMPANY
MAHAVIR CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .