Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Ok | |
| 2 | L2₹37.3 L+₹2.8 L (8.20%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹44.9 L+₹10.5 L (30.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹47.0 L+₹12.5 L (36.4%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹47.9 L+₹13.5 L (39.2%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹46.6 L
EMD Value
₹93,250
Closing Date
2 Mar 2022, 6:00 pmClosed
GE E/M BASE HOSPITAL DLEHI CANTT
GE E/M BASE HOSPITAL DLEHI CANTT-110010
REPAIR/ REPLACEMENT OF UNSERVICEABLE DUCTING GRILL DIFFUSER NITRILE INSULATIONS UNDRDECK INSULATION AND COMPREHENSIVE MAINT AND MISCELLANEOUS E/M ITEMS AT BASE HOSPITAL UNDER GE (E/M) BHDC-10
2022_MES_505233_1
GE/BH-75/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category c(i)
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSPITAL DLEHI CANTT
₹93,250
Yes
2 Apr 2022
2 Feb 2022
4 Mar 2022
2 Feb 2022
2 Mar 2022
17 Feb 2022
Amount
Supply, assembly and erection in replacement GI sheet of following sizes with C & SS rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete including necessary MS Channels, gurder supports as approved by Engr-in-Charge including making of hole in any type of wall and making good with plastering work, masonry work and necessary MS channel supports complete all as specified and as directed.
24 Gauge GI Sheet
22 Gauge GI Sheet
Supply & erection in replacement 25 mm thick nitrile duct thermal insulation with Aluminium foil, non-fibrous, fire retardant, closed cell, tri- dimensional, chemically cross linked polyethylene foam, confirm to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminium foil complete all as specified and as directed.
S&F in replacement acoustic lining of supply air ducting complete with GI frame, tissue paper, 26 Gauge perforated Aluminium Sheet, 25mm thick, of density 32 Kg/cum fiber glass insulation complete all as specified and as directed.
M&L in replacement under deck insulation for metal roof with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and Kraft paper (FSK), facing with 50 mm projection for overlap and butting in following operations complete all as directed and specified:- (a) S&F in replacement 6 mm dia MS rods between purlins suitably for supporting the required thickness of insulation material beneath the metal roof. (b) S&F in replacement 22 SWG GI/ Aluminium wires supports for insulation. (c) S&F in replacement chicken wire mesh 12.5 mm x 22 SWG of hexagonal construction below the insulation for supporting the same. (d) S&F in replacement under deck insulation with bonded fibre glass wool of density 24 Kg/Cum, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and Kraft paper (FSK), facing with 50 mm projection for overlap and butting. Note:- Insulating material shall be conforming to BS - 476, Part 4, 5, 6 & 7.
S&F in replacement Acoustic treatment/ lining of area of AHU room with 22 Gauge,GI sheet GI channels of 50x50 mm size fitted at 600x600mm girds, fitted with 50mm thick, 32 Kg/cum fibber glass insulation, covered with fibber glass tissue and 24 Gauge Aluminium perforated sheet as required, the joint shall be with minimum overlapping of 75mm with 30mmx 3mm aluminium strip covering, all corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and as directed.
Supply, installation, testing and balancing in repair square shape supply air diffusers with removable core and antismudge ring and volume control dampers, powder coated, extruded aluminium construction complete all as specified and as directed.
Supply, installation, testing and balancing in repair square shape return air diffusers with removable core and antismudge ring and without control dampers, with powder coated, extruded aluminium construction complete all as specified and as directed.
Supply and fixing in replacement air volume control damper with connected accessories, made out of 22 Gauge GI sheet with flap and operatig handle complete all as specified and as directed.
Supply and fixing fire proof double layered canvas cloth connection for AHU outlet including inspection opening complete with flanges made out of 22 GSS Sheet on both side for connection to AHE and duct complete with nuts, bolts complete all as specified and directed.
Supply and fixing GI Pipe 80mm dia heavy class fixing on wall for ducting supports including making of hole in any type of wall and making good with plastering work, masonry work complete all as specified and directed.
M/S Rohit Enterprises
sony engineering works
New Era Engineers
Vishal Traders
M/s Adhikari construction co.
Saini Enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .