| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | ₹20.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹21.3 L+₹42,647 (2.04%)Rejected-Finance NO 7 MUTHAMIZ STREET AAM NAGAR DV PURAM PONNERI TALUK TIRUVALLUR 601204 | PONNERI | TIRUVALLUR | TAMIL NADU | 601204 | ₹21.3 L+₹42,647 (2.04%) | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
17 Jan 2025, 3:00 pmClosed
Commissioner Nagercoil City Municipal Corporation
City Municipal Corporation Office Nagercoil 629001 Ph.No. 04652230984
Nagercoil Corporation Construction of Class Room Building at Meenakshipuram
2025_MAWS_516707_1
286/2024-2025_MLA
Open Tender
Civil Works
Lump-sum
90 days
Nagercoil Corporation Construction of Class Room B
Registered Contractor
4 documents required · 4 mandatory
₹0
₹30,000
10 Mar 2025
4 Jan 2025
17 Jan 2025
4 Jan 2025
17 Jan 2025
4 Jan 2025
Amount
Construction of Class Room Building
Dismantling ,clearing away and carefully stacking materials useful for re-use for any thick ness of wallsDismantling of Plain cement concrete
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls..One Course of Pressed Tile Roof finish in cement mortar
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
Laying Plain cement concrete 1:4:8 (One cement,four sand and eight aggregates) using 40mm ISS Hard broken granite stone jelly for foundation and basement including watering if found necessary and laid inlayers of 15cm thick, and consolidated including curing, cost and conveyance of all materials to work site all labour and incidental charges etc,. complete complying with standard specifications.(TNBP No.28)
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38(a) Column
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38(b) Beam & Slab
Brick work in CM 1:5 (one cement & five sand) using III class country bricks of size 8 3/4"X4 1/4" X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
Reinforced Cement concrete 1:1.5 :3 (one cement, one and half M.sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete. -Ground Floor
Reinforced Cement concrete 1:1.5 :3 (one cement, one and half M.sand & three course aggregate) using 20mm gauge hand broken/ and broken granite stone for all RCC items of works excluding centering shuttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete. -First Floor
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
Supply and Fixing of Cuddapah slab 50mm thick
Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 10mm thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Plastering with cement mortar 1:3 (One Part of Cement and Threer part of Plastering Sand (P- Sand)) 20mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309)
Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors.
Wiring with 2x1.5 sq.mm. PVC insulated unsheathed FRL SSC copper conductor of 1100V gradei nsuitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5AFT switch inflush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light /fan point (for electronic regulator) (5 points per coil)
Wiringwith2x1.5sq.mm.PVCinsulatedSCunsheathedFRLScopperconductorof1100VgradeinsuitablePVCrigidpipeconcealedinwallandceilingwithPVCaccessoriesinflushwithwallwith150mmx100mmx113mmTWswitchboxwith3mmthickhylemsheetcoverfor5A3pinnoninterlockingwallsocketwith5Aflushtypeswitchwithcontinuousearthwireconnectionof1.5sq.mmcopperwireandmakinggoodoftheconcealedportionwithsuitablecolour for concealed PVC plug point SD 38
Wiringwith2x4sq.mm.PVCinsulatedSCunsheathedFRLScopperconductorcableof1100VgradeinsuitablePVCrigidpipeconcealedinwallandceilingwithPVCaccessoriesinflushwithwallwith150mmx100mmx113mmTWswitchboxwith3mmthickhylemsheetfor15A3pinnoninterlockingwallsocketwith15Aflushtypeswitchwithcontinuousearthwireconnectionof4sq.mmcopperwireandmakinggoodoftheconcealedportionwithsuitablecolour for concealed power plug point SD 40
Supplyandfixingof1200mm(48")sweepACceilingfancompletewithsteppedelectronic300Wregulatorwith1metre down rod with fan clamp with side plates and cross arm of size 450mm (18") SD 106
4’ 18W Crystal Glass LED Tube Light Fitting
Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm]
V KUMAR (BID ID -1232299)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .