SE/GEDC/GOBI
The Superintending Engineer, 110/11 KV GOBI SS CAMPUS,VETTAIKARANKOVIL,GOBI-638476
Erection,dismantling transportation of poles, DTs, HT/LT lines in Nambiyur subdivison
2022_EB_247308_1
ET No.23 dt11.08.2022
Open Tender
Electrical and Maintenance Works
Works
30 days
GOBI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹25,000
Yes
27 Aug 2022
16 Aug 2022
27 Aug 2022
16 Aug 2022
26 Aug 2022
16 Aug 2022
Amount
Excavation of pole pit upto 27" (8.0 m) Pole by using JCB or manual
Excavation Stay pit 4.5' to 5' depth by using JCB or manual
Excavation of pole pit upto 9.14 mtr Pole by using JCB or manual
Excavation of RSJ pole pit above 36' by using JCB or manual
Excavation of pole/stay pit Hard rock without blasting (where houses are located)
Erection of RCC poles/Metal poles upto 8.00m. (27') by using JCB or manual
Dismantling of RCC poles/Metal poles upto 8.00m. (27') by using JCB or manual
Erection of RCC poles/Metal poles upto 9.14m.(30') by using JCB or maual
Dismantling of RCC poles/Metal poles upto 9.14m.(30') by using JCB or maual
Erection of RSJ joists, fabricated poles above 30'-0" (9.14 m) by using JCB or manual
Dismantling of RSJ joists, fabricated poles above 30'-0" (9.14 m) by using JCB or manual
Erection of stay set complete
Dismandling of stay set complete
Paving of conductor ,stringing etc, complete with 7/4.09mm,7/3.35mm7/3.15mm ACSR Conductor
Paving of conductor ,stringing etc, complete with 7/2.59mm ACSR/AAAC 3.15mm, Conductor
Dismantling of conductor of size 7/4.09mm,7/3.35mm7/3.15mm ACSR Conductor
Dismantling of of conductor ,stringing etc, complete with 7/2.59mm ACSR/AAAC 3.15mm, Conductor
Fixing of HT "V" cross arms(all types) / channel cross arms/guarding Cross arms
Dismantling of HT "V" cross arms(all types) / channel cross arms/guarding Cross arms
Fixing of LT 3 phase cross arms
Dismantling of LT 3 phase cross arms
Fixing of LT Single phase cross arms
Dismantling of LT Single phase cross arms
Fixing of HT/LT TI Fittings
Dismantling of HT/LT TI Fittings
Fixing of HT pin Insulators 11 KV
Dismantling of HT pin Insulators 11 KV
Fixing of HT HT 33 KV,11KV strain disc.
Dismantling of HT 33 KV,11KV strain disc.
Fixing of LT pin Insulator
Dismantling of LT pin Insulator
Fixing of LT shackle
Dismantling of LT shackle
Fixing of Aluminium Knob
Dismantling of Aluminium Knob
Earthing of pole with pin including burying looping and binding.
b. Sleeve concreting including materials (Cement 1/2 bag + river sand and Blue metals and watering)
Erection of Transformer structure complete in all respects with wiring Earthing, fixing of open type fuse units, HT/LT/LAS and jumpering 3 Nos. Earth pits with tubs including painting of metal parts, structure poles, fixing of top channel seating channel, belting angle ,concreting including material jelly , cement ,sand and colour washing of structure pole , painting of all metal parts , (Except erection of Transformer)
Erection of single pole structure (Except erection of Transformer)
Dismandling of Transformer structure complete in all respects with wiring Earthing, fixing of open type fuse units, HT/LT/LAS and jumpering 3 Nos. Earth pits with tubs including painting of metal parts, structure poles, fixing of top channel seating channel, belting angle (Except erection of Transformer)
Transporting of Distribution Transformers /Metering set by using private vechile other than bullock cart upto 30 kms
Transporting of Distribution Transformers /Metering set by using private vechile other than bullock cart above30 kms
Transporting of poles /material /conductor and other material (Excluding and unloading charges)below 8 kms
Transporting of poles /material /conductor and other material (Excluding and unloading charges)above 8 kms for additional
Return Transport charges of private vechicle (After unloading of materials) upto 8 km
Return Transport charges of private vechicle (After unloading of materials) beyond 8 km for every addl km irrespective of weight
loading of poles upto 27'-0"
loading of poles upto 30'-0"/RSJ Pole
Un loading of poles upto 27'-0"
Un loading of poles upto 30'-0"/RSJ Pole
Transporting of poles from road site to pole pit including loading and unloading of poles by using JCB or manual up to 100 m
Transporting of poles from road site to pole pit including loading and unloading of poles by using JCB or manual beyond 100 m
Loading or unloading of Transformer upto 100 KVA for each
Erection of New Transformer of all capacity
Dismandling of Transformer upto 200 KVA
Erection of street light including fixure fitting
Erection of street light service
Releasing of single phase service and re-fixing.
Releasing of 3 phase service and (upto 50 HP) re-fixing.
Erection of D.P. structure with AB switch top channel, cross brancing, HG fuse set, earthing painting earthing painting, providing stay and pole concreting
Drilling of hole in channel only 3/4" & 1" per hole
cutting of channel
Guarding Arrangements LT split neutral guarding
Guarding Arrangements HT split neutral guarding
Releasing of grills from RCC pole
Labour charges for alteration of clamps to suit for the works
Resagging of conductor ,stringing etc, complete with 7/4.09mm,7/3.35mm7/3.15mm ACSR Conductor
Resagging of conductor ,stringing etc, complete with 7/2.59mm ACSR/AAAC 3.15mm, Conductor
Providing LT Busbar arrangement in Distribution Tr.Structure location
Provision of Distribution Transformer Name board (Name of the 33/11KV #, Name of the SS, Capacitor, Danger board)
Realising of ACSR/AAAC Conductor from conductor drum and coiling ACSR 7/3.35, 7/2.59 AAAC 7/2.50, 7/3.15MM (Per km)
TI Fitting welding with clamps
Clearing of branches of trees
Feeding Arrangements with open type fuse unit
stage.html
html • 0.02 MB
finance_292540.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .