Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.5 CrAccepted-AOC CIVIL WORKS FOR CONSTRUCTION OF ADDITIONAL OFFICE BLOCK AT IOCL PUNJAB STATE OFFICE BUILDING PLOT NO 3A SECTOR 19 A CHANDIGARH UT | NA | NA | 160001 | ₹6.5 Cr | 1 | Accepted-AOC 1 |
| 2 | 2₹6.7 Cr+₹24.5 L (3.79%)Rejected-AOC | ₹6.7 Cr+₹24.5 L (3.79%) | 2 | Rejected-AOC 2 |
| 3 | 3₹6.9 Cr+₹42.3 L (6.54%)Rejected-AOC H NO 861 12 SALARA MOHALLA ROHTAK 124001 HARYANA INDIA | ROHTAK | HARYANA | 124001 | ₹6.9 Cr+₹42.3 L (6.54%) | 3 | Rejected-AOC 3 |
| 4 | 4₹6.9 Cr+₹46.1 L (7.13%)Rejected-AOC ANAND PURA ROHTAK H NO 521 20 NEAR BAL BHAWAN ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹6.9 Cr+₹46.1 L (7.13%) | 4 | Rejected-AOC 4 |
Tender Value
₹7.4 Cr
EMD Value
₹14.8 L
Closing Date
17 Nov 2023, 12:00 pmClosed
Gopal Kalawat
Municipal Corporation Gurgaon
ESTIMATE FOR BALANCE WORK OF COMMUNITY CENTRE (CIVIL WORK, PLUMBING WORK and ELECTRICAL WORK ) IN SECTOR 14, WARD NO-06, ZONE- 02, GURUGRAM, UNDER MCG AREA.
2023_HRY_321279_1
20231955FA6A AA6E 49E7 9E9A 82CAFEF01AEB285ULB
Open Tender
Civil Works
Works
300 days
Gurugram
2 documents required · 2 mandatory
₹20,000
₹14.8 L
Yes
O/o Chief Engineer
16 Mar 2024
17 Oct 2023
17 Nov 2023
17 Oct 2023
17 Nov 2023
17 Oct 2023
26 Oct 2023
Amount
Providing and fixing C.P. flange (cap)
Supply of iron J- hook complete in all respect
Supply of G.I tank connecting nipple for connecting tank of 25 mm internal dia with check nuts
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make..Single Tee with Door 75mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make...Single Tee with Door 110mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Single `Y` with Door 75mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Single `Y` with Door 110mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend 45 Dg. 75mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend 45 Dg. 110 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend 87.5 Dg. 75 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend 87.5 Dg. 110 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Nahni Trap with Jali 4” 110 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Nahni Trap with Jali 4” 75 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make110mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality / OFFSET 110mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make of approved quality /make Supreme/ kasta 200 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make of approved quality /make Supreme/ kasta 250 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme / kasta Coupler (socket).160 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme / kasta Coupler (socket).200 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme / kasta Coupler (socket).250 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme / kasta Single Tee with Door 160 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme / kasta Bend 45 Dg. 160 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme / kasta Door Bend 87.5 Dg. 160 mm dia
Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M
Providing and fixing gunmetal equilibrium float valve with S.S. rod and 2 mm thick copper float, tested for 10 Kg/Sq.cm complete including companion flanges, nuts, bolts, washer etc. complete in all respect.65 mm dia
Providing and fixing gunmetal equilibrium float valve with S.S. rod and 2 mm thick copper float, tested for 10 Kg/Sq.cm complete including companion flanges, nuts, bolts, washer etc. complete in all respect.50 mm dia
SITC of Local fire authority approved Diesel Engine driven Pump suitable for automatic operation as per discharge defined beolw consisting of the following details given as A, B, C, D, E and F . (A) Horizontal Single / Multi stage Centrifugal End suction, back pull type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, Butterfly valve on the suction side ( all items to be matching with the suction side dia of the pump) and pressure gauge ,Butterfly valve and non return valve on the delivery side side ( all items to be matching with the delivery side dia of the pump) and including bypass arrangement for Testing of pump (B) Material of construction : Pump Casing - Cast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal (C)Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head (D) Radiator cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1500 / 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump,Antivibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically if the Normal electrical supply fails with a unit of battery bank of 12/24v,180 Ah, Lead Acid Battery with Boost / Trickle charger as required for operation of Diesel engine, Exhaust Pipe of suitable diameter minimum 10 M length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumping set, (E) Pump is to be inspected by third party like RITES / PDIL at manufacturer`s premises and inspection report is to be submitted. (F) Suitable cement concreat foundation duly plastered with anti vibration pads. 2280 LPM suitable for 88 Mtr Head, multi stage, 1500
SITC of Local fire authority approved Vertical multistage Jockey pump with SS Body, SS impellor, SS shaft, mechanical seal coupled with Squirrel cage induction motor for automatic operation suitable for three phase, 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM ,T.E.F.C type confirming to IP:55 with flexible coupling and coupling guard with the pump ,Common bed plate fabricated from mild steel channel , Suitable cement concreat foundation duly plastered with anti vibration pads.180 LPM suitable for 30
SITC of pressure switches for Main, Jockey pump and standby Diesel pumps, including necessary wiring upto control panel and Ball valve.
Supplying and fixing air vessel of continuous welded construction for pump room made of 450 mm dia,fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, 2000 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun Metal wheel valve, with required accessories, pressure gauge and painting with two coats of Red Oxide and two coat of post office red enamel paint as required.
Providing, installation, testing and commissioning of stainless steel strainer of dia given below fabricated out of 1.6 mm. thick stainless steel sheet with 3 mm. dia holes with stainless steel flange of following sizes. 150 mm dia
Supplying and fixing, testing and commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze /gun metal seat ISI marked complete with nuts, bolts, washers, gaskets, conforming to IS 780 of following sizes as required. 150 mm dia
SandF following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required. 25 mm
Providing/Laying P.V.C. / XLPE insulated and P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. a) 3.5C x 25.0 Sq.mm
Providing/Laying P.V.C. / XLPE insulated and P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.b) 3.5C x 120.0 Sq.mm
S and Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. a) 8 SWG GI Wire
Supplying, Installation, Testing and Commissioning submersible type dewatering pump of stainless steel / Noryl casing and impellor of discharge and head given below complete with base plate and all accessories suitable for operation on 230 V, single phase/415 V /3 phase, 50 Hz. AC supply complete with starter for automatic operation including water level sensing device / float switch inter connection with submersible cable etc. as required. 180 LPM with 10 mtr head
Supplying and fixing Gun metal single headed Internal / external yard hydrant valve with 1 No. 63 mm dia instantaneous Gun metal coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal cap and chain as required.
Supplying and fixing of Hose Cabinet of size 750 mm x 600 mm x 250 mm made of 1.6 mm thick MS sheet with 6 mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 Nos 15 Mtr. Long Hose pipe, 1 No. branch pipe, mounted on wall OR raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant, as required
Supply, testing and commissioning of 90 W LED, IP-65/66 integral Street light fitting, pressure die-cast aluminium housing, powder coated light fitting complete with LEDs, total lumen out put shall not not less than 9000 lumens , heavy duty driver, THD less than 10%,100V-265V single phase AC system, surge protection, totally enclosed with toughened glass cover, pole mounting arrangement etc and as per specifications, complete as required As per Goldwyn Cat Ref: XS 04 18 New -90W, Bajaj Ref: EDGE (BRTFG) Series, Philips Ref: BRP322 LED (7000-12500lm) or Eq. approved as per list of approved
Supplying and fixing Fire Brigade Connection of CI body with Gun Metal male instantaneous inlet couplings complete with cap and chain as required for 150mm dia MS pipe connection, conforming to IS 904 as required of following way : a) 2 Way (for Drawout )
Supplying and fixing Fire Brigade Connection of CI body with Gun Metal male instantaneous inlet couplings complete with cap and chain as required for 150mm dia MS pipe connection, conforming to IS 904 as required of following way :b) 4 Way (for Inlet)
Supply, testing and commissioning of 120 W LED, IP-65/66 integral Street light fitting, pressure die-cast aluminium housing, powder coated light fitting complete with LEDs, total lumen out put shall not not less than 10100 lumens , heavy duty driver, THD less than 10%,100V-265V single phase AC system, surge protection, totally enclosed with toughened glass cover, pole mounting arrangement etc and as per specifications, complete as required Make: Bajaj,
Providing and fixing of 4 way suction coupling for fire brigade withdrawal of water from fire tank with 150mm dia pipe and foot valve.
Supplying and fixing 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia male and female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required.
Providing and fixing 100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg ) range, 3 / 8 ` BSP bottom entry on Pump Delivery Line complete with Ball valve
Supplying and fixing first -Aid hose reel wall mounted swinging type with MS construction spray painted in post office Red, conforming to IS 884 with upto date amendments, complete with the following as required.(A) 30 m long 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type -2 as per IS: 12585 (B)20 mm (nominal internal) dia gun metal globe valve and nozzle.(C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 40 mm dia stop valve (gun metal) and M.S. pipe
Supply, installation, testing and commissioning of following type of LED/CFL fixtures including all fixing accessories, ballast/driver as required. All fixtures shall be supplied with lamps.Make: Crompton Greaves/Wipro/Bajaj/Phillips 30 Watts recessed mounted LED circular down lighter complete as required with minimum 2800 Lumens
Supply and Fixing of Fire Man`s Axe with heavy Insulated rubber tested up to 20 KV and confirming to IS :926
Supply, installation, testing and commissioning of following type of LED/CFL fixtures including all fixing accessories, ballast/driver as required. All fixtures shall be supplied with lamps.Make: Crompton Greaves/Wipro/Bajaj/Phillips 10 Watts recessed mounted LED circular down lighter complete as required with minimum 840 Lumens
Providing, laying, testing and Commissioning of `C` class heavy duty MS pipe conforming to IS 3589 / 1239 for hydrent and sprinkler applications including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and including painting of two coats of Red Oxide , painting with two or more coats of synthetic enamel paint of Post office red shade complete as required.The installation includes all civil openings ,breakages and making good the same. i 25 mm dia
Providing, laying, testing and Commissioning of `C` class heavy duty MS pipe conforming to IS 3589 / 1239 for hydrent and sprinkler applications including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and including painting of two coats of Red Oxide , painting with two or more coats of synthetic enamel paint of Post office red shade complete as required.The installation includes all civil openings ,breakages and making good the same. ii 40 mm dia
Providing, laying, testing and Commissioning of `C` class heavy duty MS pipe conforming to IS 3589 / 1239 for hydrent and sprinkler applications including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and including painting of two coats of Red Oxide , painting with two or more coats of synthetic enamel paint of Post office red shade complete as required.The installation includes all civil openings ,breakages and making good the same. iv 65 mm dia
Providing, laying, testing and Commissioning of `C` class heavy duty MS pipe conforming to IS 3589 / 1239 for hydrent and sprinkler applications including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and including painting of two coats of Red Oxide , painting with two or more coats of synthetic enamel paint of Post office red shade complete as required.The installation includes all civil openings ,breakages and making good the same. v 80 mm dia
Providing, laying, testing and Commissioning of `C` class heavy duty MS pipe conforming to IS 3589 / 1239 for hydrent and sprinkler applications including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and including painting of two coats of Red Oxide , painting with two or more coats of synthetic enamel paint of Post office red shade complete as required.The installation includes all civil openings ,breakages and making good the same. vii 150 mm dia
Supply, installation, testing and commissioning of following type of LED/CFL fixtures including all fixing accessories, ballast/driver as required. All fixtures shall be supplied with lamps.Make: Crompton Greaves/Wipro/Bajaj/Phillips 15 Watts recessed mounted LED circular down lighter complete as required with minimum 1400 Lumens
Providing, laying, testing and Commissioning of `C` class heavy duty MS pipe conforming to IS 3589 / 1239 for hydrent and sprinkler applications including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and including painting of two coats of Red Oxide , painting with two or more coats of synthetic enamel paint of Post office red shade complete as required.The installation includes all civil openings ,breakages and making good the same. viii 200 mm dia, 6.0 mm thick
Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, G I bolts, nuts, washers etc. as required. i 80 mm dia
Supply, installation, testing and commissioning of following type of LED/CFL fixtures including all fixing accessories, ballast/driver as required. All fixtures shall be supplied with lamps.Make: Crompton Greaves/Wipro/Bajaj/Phillips 36 Watts recessed mounted LED square down lighter complete as required with minimum 3600 Lumens
Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, G I bolts, nuts, washers etc. as required. i 150 mm dia
Supplying, fixing, testing commissioning of butterfly valve PN 1.6, with Bronze/ Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following sizes as required. a) 80 mm dia
Supply, installation, testing and commissioning of Box type LED Tube Light fixture made of Alluminium sheet channel 22 watts High efficiency 1900 lumens and high frequency replacable digital ballast. Make: Crompton Greaves/Wipro/Bajaj/
Supplying, fixing, testing commissioning of butterfly valve PN 1.6, with Bronze/ Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following sizes as required. c) 150 mm dia
Providing, installation, testing and commissioning of Brass ball valves of following sizes as required. 25 mm dia
Providing, fixing, testing and commissioning of 15 mm dia size ,quartzoid bulb sprinkler heads suitable for 68 degree centigrade rating of the following type : i Pendant type
P and F of IP 66 protected High Power LED Flood Light system with extruded aluminium housing, toughened glass diffuser with suitable lenses on LED to acheive various beam angles, System power 40W - 60W 240V, 50 - 400 Lumens system output of High Power LED lamps supplied with pre-wired cable of 1 mtr. Integrated Driver shall be high efficiency having efficiency ) 85% and in compliance to IEC standards (Price to be quoted with light fixture). System life of 25,000 Burning Hours with 70% of initial Lumens maintained. Light output in Red, Green, Blue, Cool white or Warm White Colour as per engineers choice. Fixtures shall be CE and KEMA
Supply and Fixing ISI marked ( IS : 15683 ) Poratable Fire Exitnguisher,Trolley mounted Mech. Foam type capacity 09 ltrs with gun-metal cap and nozzle and complete respects in all respects including initial fill and wall suspension.
Supply, testing and Commissioning of low intensity avaition ostruction LED light having 35cd in any direction (red color),single emitter, cast aluminium housig, weather proof IP-65, painted with corrosion resistant paint, covered by hard ABS red cover dome, with mounting pole and other accessories as
Supply and Fixing ISI marked ( IS : 15683 ) Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of following capacity. 6 kg
Supply and Fixing ISI marked ( IS : 15683 ) Portable fire Extinguisher, Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia. min. 600 mm long and complete in all respects including initial fill with C02 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667and wall suspension bracket. Capacity 4.5 Kg.
SITC of Active repeater panel with function keys flike Reset, Alarm Acknowledge, Alarm Silence, Trouble Acknowledge on panel itself etc. as per specification.
Supply of Hot Dip Galvanised Octagonal steel pole on RCC foundation as per the design of manufacturer considiaring wind pressure and speed, light fixture and pole load, pole shall have weather proof terminal box with in the pole with lockable rigid and vandal resistant hinged metal cover flushed to pole exterior surface and control MCB 10kA `C` curve , power terminals for loop-in and loop-out arrangment of cable terminations, gland plate, the terminal box shall at height of app. 500mm above the base plate, suitable earthing studs shall be provided in side the pole, pole shall be in single section and without any circumferential weld joint, hot dip galvanising shall be as per latest IS: indian standards and coating thickness shall not be less than 70 microns. Pole shall be made out HT steel of grade S355JO, Pole shall have 4Nos. foundation bolts of EN-8 grade and base plate as per IS226/IS 2062. (Foundation and pole installation is not included in this item) 7Meter long with Single arm (1M size) suitable for required light fixture mounting and with arrangement, Bajaj Cat . BOP-9030 or equivelent approved from the list of makes
3 Meter long with Single arm (1M size) suitable for required light fixture mounting and with arrangement, Bajaj or equivelent approved from the list of
SITC of 4 loop Multi loop Microprocessor based intelligent and modular, 100% electronically addressable system where field device addressing is done by panel and not user, complete touch screen system with peer to peer networking of 126 network nodes, loop capacity of 200 devices per loop, built in charger and 2x9AH battery which is sealed lead scid rechargable maintenance free type that can support backup upto 24hours idle condition and 15 minutes during alarm condition, with Zonal LEDs on board, capacity to have upto 250 logic zones created, Touch LCD screen display with LED technology, 4 NAC circuits, 3 programmable relays, dedicated Alarm relay, Integral short circuit, Event history on 9999 logs, option to load Logo on the main screen, view live analog level of field devices on the panel screen, option to download these events log and analog level report from panel, 3 detector sensitivity levels, option to change the operating temperature of heat detectors from panel, option to change the volume and tone of loop powered base sounders from panel, Alarm verification option, T1/T2 timer option, field outputs modules programmable with 3 stage program options, have open path programming software, capacity to communicate loop mount repeater panels, optional NAC power supply units that are loop mountable and 100% supervised from main panel.
SITC of Addressable type manual fire alarm boxes (MCP/Pull Station ) shall, on command from the control panel, send data to the panel representing the state of the manual switch and the addressable communication module status. Manual fire alarm boxes shall be constructed of Lexan with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in raised letters, 1.75 inches (44 mm) or larger. etc. as required.
SITC of Addressable 2 wire optical Smoke detector, 100% soft addressing, single LED that covers 360Deg lightpipe technology with intensity that can handle upto 5000 Lux, Discreet design for incorporation into any décor, Common mounting base, Drift compensation, Removable detector chamber, Chamber monitoring by panel, option to connect remote indicator.
SITC of Addressable Ultraviolet Flame detector 2 wire 3 sensitivity levels, dust proof, damp proof and corrosion proof having IP21 rating. Discreet design for incorporation into any décor, Common mounting base, Drift compensation, Removable detector chamber, Chamber monitoring by panel, option to connect remote indicator.
SITC of Addressable Wall mount or ceiling mount loop powered sounder strober. IP33 rating and sound output of 98DB @ 1 Mt.
SITC of Base mount short circuit isolator, to be used as a detector base. Capability to automatically resume after short circuit is removed, load ability upto 32 devices. Chamber monitoring by panel, option to connect remote indicator
Supply and Fixing of signs Auto-Glo, (list of design attached), based on acrylic, single sided wall pasted size 12” x 6”
SITC of 2CORE 1.5SQMM FRLS FLEXIBLE COPPER CABLE
Supply, testing and Commissioning of ceiling fan ISI, 5-star rated/certified with copper wound heavy duty motor in die cast aluminum housing, three nos. Aluminum blade, double ball bearings, capacitor, canopies , down rod with mounting shekel and rope hanger including wiring the down rod of standard length with 1.5 sq.mm. FRLS insulated, copper conductor, single core cable as per specifications and complete in all respects. Supply and Fixing of 900 mm sweep High Speed Ceiling fan with standard down rod, all accessories Electrical connections. Including fixing materials required.as per ECBC and GRIHA compliance
Supply and Fixing of 1050 mm sweep Make High Speed Ceiling fan with standard down rod, all accessories Electrical connections. Including fixing materials required.as per ECBC and GRIHA compliance
Supply and Fixing of 1200 mm sweep Make High Speed Ceiling fan with standard down rod, all accessories Electrical connections. Including fixing materials required.as per ECBC and GRIHA compliance
Supply and Fixing of 1400 mm sweep Make High Speed Ceiling fan with standard down rod, all accessories Electrical connections. Including fixing materials required.as per ECBC and GRIHA compliance
Supplying, testing and commissioning of 1400 RPM, 300MM size heavy duty exhaust fan with mounting frame, complete with copper wound motor etc. as req. as per ECBC and GRIHA compliance 400mm Sweep
Supplying, testing and commissioning of 1400 RPM, 300MM size heavy duty exhaust fan with mounting frame, complete with copper wound motor etc. as req. as per ECBC and GRIHA compliance 230mm Sweep
Supply and fixing in position 1000 mm wide 2.0 mm. thick 1100 V grade insulating floor matting with resin bound required adhesive tested for die-electric strength and quality as per BIS-15652:2006 of approved make and ISI marked.
P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 and 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia. 50/55 mm
P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 and 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia. 100/95 mm
P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 and 2 with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia. 300/260 mm
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 300x300 mm 400mm deep including with heavy duty ductile double sealed iron recessed frame and cover with load rating not less than 12.5 tonnes and as per Euro norms BS EN -124
EXTERNAL LIGHTING Feeder Pillar INCOMER: 32A, FP MCB, 10 kA `C` curve protection release, ON LED indicating light with control MCB -9Set BUS BAR - 32A, 415V three Phase 4 wire, four equal ratting colour coded, non-adhesive PVC insulated electrolytic `Al` conductor bus bars OUTGOINGS 16 A, FP MCB, 10 kA `C` curve protection release, ON LED indicating light with control MCB - 7Set NOTES: 1)L.T.Panel shall be suitable to receive all incoming and outgoing from Top /Bottom 2)MCCB`s shall be with extended type Door operating mechanism with door interlock, phase barriers and copper spreaders. 3) Ics=100%Icu, for all MCCBs 4)All CT`s shall be cast resin type. 5) All Incomers and Bus coupler of main LT panel shall be interlocked. 6) Floor mounted type panels shall have ISMC base channel at entire bottem of ISMC-100MMsize.
SITC of 800 KVA, 11/0.433 KV Copper Wound Outdoor Type Transformer Complete with first filling Of Transformer Oil and All other Standard Accessories. (As per BIS Level-I Specification.) (IS:1180) and as per ECBC compliance.
Supply Installation testing and commissioning of 2Cx1.5 Sq mm Copper cable meant for PA system
Supply and lowering 150 mm dia, PVC pipe `having perforation 10-25 mm size all sides of the pipe in Zig-Zag fashion and making air vent at top including the cost of , Socket etc.
Providing Laying and jointing glazed S.W. pipes grade `A` (IS:651 marked) of approved make with spun yarn and stiff mixture of cement mortar 1:1, excavation and refilling of earthcomplete.in all types of soil upto 1.2m depth, S.W. fittings, including testing of joints etc,
Construction of tubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with `code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemed completed only after obtaining sound free water during pumping
Providing and fixing in position best Indian make Towel rails fixed in with rawl plugs embedded in walls with C.P. brass screws complete in all respects including cutting and making good thea) 25 mm dia C.P. brass adjustable ii) 600 mm long
Providing and fixing C.P brass liquid soap container of best quality (as required by the Engineer-in-charge)
Providing and fixing in position automatic brass ball valves in tanks With plastic ball 25mm internal diameter
Extra Provision for for OH tank water indicatos
P/F in position Gully traps fixed in cement concrete 1:4:8 with HCI grating 150x150mm CI cover weighing approximately 7.26 kg and frame clear opening 300 x 300mm and outside size 330mm x 330mm and chamber including cost of all brick work 1:5 cement concrete 1:8:16 in foundations and C.C. 1:2:4 in coping around CI cover and frame etc. with 3 coats of black bitumastic paint of approved manufacture on all CI work as per standard design, minimum depth of water should be 150mm with a minimum seal 50mm. a) 100mm internal diameter S.W. gully traps
Making sewer connection with existing sewer line 450 mm
Providing and fixing in position best Indian make paper holders fixed into wall with C.P. brass screws complete in all respects including cutting and making good the walls etc. (a) C.P. brass
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Vent Cowel 110mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Coupler (socket) 75mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Coupler (socket) 110mm dia
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp, 30KA, FP MCCB
SITC of following item Advance Lightning Protection System including all necessary fixing accessories and effective connections complying the detailed technical specifications given therein. electronic based lightning protection system working principle on piezoelectric technology, Complying standards like NF C 17-102:2011, EN 50164 and UNE 21.186, Air terminal is made up of stainless steel suitable for every weather conditions Protection radius – 70M
P and F of IP65 IK10 protected LED Bollard fixture with extrusion aluminium housing, LED 8W - 12W, 220V-240V, 50Hz LEDs with available in quick connecting cable coupled with various mounting accessories.Driver shall be high efficiency having efficiency ) 85% and in compliance to IEC standards (Integral with light fixture). System Power Consumption of 8W - 12W ~ 300 - 400 lumens, system life of 25,000 Burning Hours with 70% of initial Lumens maintained. Light output in Cool white or Warm White Colour as per engineers choice. Fixtures shall be CE and KEMA compliance. 0.8 mtr high bollard.
Supply,Installation, testing and commissioning of water cooler (storage type ) fully stainless steel of 150/150 ltrs capacity as per IS standards with all accessories. as per site requirment suitable for operation on 230 V plus /- 10% , 50 Hz, single phase AC supply complete as reqd. Make Blue Star/ Sidwal/ Usha etc. The work includes PVC connection, control cable with plug top, drain pipe by making hole and chase cutting wherever it required as per site and repair the same with original finish etc as reqd..
Supply, Installation, testing and commissioning s of 2.0 tonne BEE rated 3 star inverter type cassette AC Complete with indoor and outdoor unit alongwithy drainage,, seamless heavu duty Cupper piping with thermal insulation , suction pipe , refrigerant gas ,, with all accessories like remore control, cabling etc. in all respect.
Supply, Installation, testing and commissioning s of 1.5 tonne BEE rated 3 star inverter type high wall split unit AC Complete with indoor and outdoor unit alongwithy drainage,, seamless heavu duty Cupper piping with thermal insulation , suction pipe , refrigerant gas ,, with all accessories like remore control, cabling etc. in all respect.
Bidder Name
Amount
Sh. Vipin Kumar Jain(GSTN-06AGPPJ7035D1ZG)
M/s Tech Sphere Infrastructures(GSTN-06AQAPS2700D2ZE)
Ashok Kumar Garg(GSTN-06ABTPG1118P1ZC)
Vijender Kumar Contractor(GSTN-NA)
Ashok Kumar Garg
Vijender Kumar Contractor
Sh. Vipin Kumar Jain
Sh. Vipin Kumar Jain
Vijender Kumar Contractor
M/s Tech Sphere Infrastructures
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .