| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC 0 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹35.5 L+₹48,873.60 (1.40%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹36.6 L+₹1.6 L (4.51%)Rejected-Finance 26M NEEM SARAI DHOOMANGANJ PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹39.5 L+₹4.4 L (12.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tender | |
| 5 | L5₹40.3 L+₹5.3 L (15.0%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L5 | Rejected-Finance Other than lowest tender |
Tender Value
₹3.6 L
EMD Value
₹72,000
Closing Date
2 Sept 2021, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
SPECIAL REPAIR FOR REPLACEMENT OF LIGHTS AT OFFICERS MESS,HQ CAC LAWN,SUB GUARD ROOM OF QFFICERS MESS AND ALLIIED WORKSUNDER GE(AF) BAMRAUL
2021_MES_460902_2
8666/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (AF) Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Bamrauli
₹72,000
15 Sept 2021
19 Aug 2021
3 Sept 2021
19 Aug 2021
2 Sept 2021
26 Aug 2021
Amount
S&F in replacement of Decorative Pole of size 5 mtr long with shaft top is 76 mm, shaft bootom 140 mm and Size of base plate 250x250x16 mm made with pipe of ERW standard as per IS 1239 having decorative cast iron embellishment for beautification with hot dip galvanized completely covered with minimum 70‐80 microns. The Pole is coated with epoxy zinc phosphate primer of 40 microns and finished using polyurethane based paint The Pole is provided with flush door at bottom with the proper strengthen to cut out of the door opening; with special panel lock key and safety chain; with 63 Amps 4‐way heavy duty Bakelite connector for loop in loop out arrangement and MCB channel to mount MCB. All this arrangement will be mount upon heavy duty Bakelite sheet into the pole .Hardware used is non‐corrosive grade SS304 Complete fitting is pure polyester based powder coated with high corrosion resistance and chemical chromicised protection, also available with multiple coats of weather resistant polyurethane paint in various colours. Cat part No : Acropolis pole 5 mtr, Make : Surya or equivalent of Make : Crompton/Philips/Mepro
S&F in replacement of Decorative Pole of size 3100mm long with shaft top is 76 mm, shaft bootom 140 mm and Size of base plate 250x250x16 mm made with pipe of ERW having decorative cast aluminium heavy pole designer leg and broarder designer based finished with polyurithane paint alongwith Square junction with max projection breadth of 625 mm suitable for two no. of post top lantern .The Pole is coated with epoxy zinc phosphate primer of 40 microns and finished using polyurethane based paint The Pole is provided with flush door at bottom with the proper strengthen to cut out of the door opening; with special panel lock key and safety chain; with 63 Amps 4‐way heavy duty Bakelite connector for loop in loop out arrangement and MCB channel to mount MCB. All this arrangement will be mount upon heavy duty Bakelite sheet into the pole .Hardware used is non‐corrosive grade SS304 Complete fitting is pure polyester based powder coated with high corrosion resistance and chemical chromicised protection, also available with multiple coats of weather resistant polyurethane paint in various colours. Cat Part No. MCPL-07 and CDPB-05) of Mepro make and equivalent of Make : Surya/Crompton/Philips
S&F in replacement of Post Top Lantern fitting with AL die-cast section in powder coat finish, opal acrylic diffuser fitting with 30/40W LED,IP 65 protection, system efficacy > 100 Lm/W, product life 50000 hrs @ L70, surge protection 5KV Internal complete with all accessories such as , bipin holder etc including provn of three core cable of copper conductor of size 2.5 sqmm 3 core of white covering , for making connection, fixing the fitting on pole including all necessary fixing accessories complete all as directed. Cat Part No : VEGA TM 40W, Make Surya or equivalent of Make : Crompton/Philips/Bajaj/Syska/Havells
S&F in replacement of LED Flood light fitting 50 watt, warm white with surge protection 4KV inbuilt in driver and minimum 10 KV separate, IP66 having Pressure dia cast aluminum housing with heat resistant toughened glass, individual LED lenses complete making connection with suitable in size 3 core of wire and suitable for mounted on angle iron frame. (i) The driver should be potted ant vibration type, IP66 should be sustain 440 volt for 2-4 hrs (ii) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided (iii) CRI (Colour Rendering Index of fixture shall be greater then 70 (iv) CCT ( Colour correlated Temperature) of fixture shall be ± 300K (v) system lumen efficiency shall be > 100 lumen/Watt complete all as specified and directed. Make : Crompton/Philips/Bajaj/Syska/Havells
S&F in replacement standard Post Top Lantern fitting with 25W LED,IP 65 protection lamp spherical shape polycarbonate, opal acrylic diffuser complete with all accessories such as , bipin holder etc including provn of three core cable of copper conductor of size 2.5 sqmm 3 core of white covering , for making connection, fixing the fitting on 40/50mm pole including all necessary fixing accessories complete all as directed. Make : Crompton/Philips/Bajaj/Syska/ Havells
S&F in replacement of LED Bollard Flare fitted size 650mm long and 140mm dia with AL die-cast base in powder coat finish, opal acrylic diffuser fitting with 9W LED,IP 65 protection, system efficacy > 40 Lm/W, product life 50000 hrs @ L70, base mounting, CCT 5700K, CRI > 70, surge protection 5KV Internal complete with all accessories such as , bipin holder etc including provn of three core cable of copper conductor of size 2.5 sqmm 3 core of white covering , for making connection, fixing the fitting on foundation including all necessary fixing accessories complete all as directed. Make : SLEBL 12W-FLR650 Surya Make or equivalent of make Crompton/Havells/Syska.
Supply & Laying in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm4 Core. Make : Hevells/Universal/Glostar
Excavation in trenches/Pits in any type of soil(soft/loose soil), n.exc. 1.5M wide and n.exc. 1.5M deep and getting out complete, all as specified & directed .
Returning filling in with the earth obtained from Item No 1 here-in-before including spreading, leveling and well ramming in layers n.exc. 25cm thick complete all as specified & directed.
Removal of surplus excavated material to a distance n.exc. 50 Mtr and depositing where directed at a level n.exc. 1.5 Mtr above starting point complete all as specified & directed
M&L for providing old size sub class 'B' bricks laid perpendicular to the cable abutting each other all as specified and directed by the Engineer-in-charge.
Supply and spreading clean and dry sand (unwashed) in trenches around the cable for cushioning all as specified & directed
Supply and fix in replacement of junction box [FRP] of size 250x200x100mm complete with insulator 100 apms AL bus bar 4 way MCB SP 06 amps capacity with necessary fixing arrangements by providing MS clamps 2 nos made out of MS flat 25 x 5mm including nut bolts etc complete.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items of this schedule. The same shall be recovered from various payment to contractor before handing over old material.
FRIENDS N FRIENDS
bharat construction
sethi tradres
M/S VIJAY SINGH
M/S Rakesh Singh
M/S SATISH KUMAR
M/S R S Traders
M/s M A Traders
Mohit Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .