| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAdmitted-Finance FLAT NO T 1 PLOT NO 902 THIRD FLOOR MAYUR ENCLAVE 2 PANKI KANPUR NAGAR UTTAR PRADESH 208020 | KANPUR NAGAR | UTTAR PRADESH | 208020 | ₹1.9 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Hi Tech Power Project L1 |
|---|---|---|---|---|
| 1.01 | SH:I (Electrical Installations) :: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. [a] 3x1.5 sqmm. | 10 | Mtrs. | 850 ₹1,003 Lowest |
| 1.02 | [b] 3x4 sqmm. | 10 | Mtrs. | 1,850 ₹2,183 Lowest |
| 1.03 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) [a] 4 way (4 + 12), Double door. | 1 | No. | 6,785 ₹8,006.3 Lowest |
| 1.04 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [a] Single pole | 3 | Nos. | 693 ₹817.74 Lowest |
| 1.05 | [b] Triple pole and Neutral | 1 | No. | 1,109 ₹1,308.62 Lowest |
| 1.06 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. [a] 100 A | 1 | No. | 1,109 ₹1,308.62 Lowest |
| 1.07 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE armered al conductor power cable of 1.1 kV grade of following size in the existing pole/masonry open duct/in air etc. complete as required. [a] 4 X 16 sq. mm | 3 | Mtrs. | 1,389 ₹1,639.02 Lowest |
| 1.08 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [a] 4 X 16 sq. mm | 2 | Sets | 840 ₹660.8 Lowest |
| 1.09 | Supplying and Laying of 20mm. dia.PVC flexible conduit pipe from existing MS conduit to TPDB for drawing of wires etc. as reqd. | 20 | Mtrs. | 58 ₹684.4 Lowest |
| 1.10 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 10 | Mtrs. | 1,260 ₹743.4 Lowest |
Tender Value
₹1.9 L
EMD Value
₹3,710
Closing Date
11 Aug 2026, 4:00 pmClosed
Executive Engineer(E), BSNL Elect.Division,Kanpur
Executive Engineer (E), BSNL Electrical Division, 7th Floor, DSB. Mall Road,Kanpur
Providing EI, Fans, Earthing and SAC at New TE Building Sakrar, Jhansi.
2026_BSNL_286357_1
14/TED-KP/2026-27 dt.01.08.2026
Open Tender
Electrical Works
Item Rate
30 days
JHANSI
Plz refer tender docs
2 documents required · 2 mandatory
₹590
AO(Cash) O/o GMTD, BSNL, Kanpur
₹3,710
16 Sept 2026
3 Aug 2026
12 Aug 2026
3 Aug 2026
11 Aug 2026
3 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | SH:I (Electrical Installations) :: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. [a] 3x1.5 sqmm. | 10 | Mtrs. | - | - |
| 1.02 | [b] 3x4 sqmm. | 10 | Mtrs. | - | - |
| 1.03 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) [a] 4 way (4 + 12), Double door. | 1 | No. | - | - |
| 1.04 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [a] Single pole | 3 | Nos. | - | - |
| 1.05 | [b] Triple pole and Neutral | 1 | No. | - | - |
| 1.06 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. [a] 100 A | 1 | No. | - | - |
| 1.07 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE armered al conductor power cable of 1.1 kV grade of following size in the existing pole/masonry open duct/in air etc. complete as required. [a] 4 X 16 sq. mm | 3 | Mtrs. | - | - |
| 1.08 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [a] 4 X 16 sq. mm | 2 | Sets | - | - |
| 1.09 | Supplying and Laying of 20mm. dia.PVC flexible conduit pipe from existing MS conduit to TPDB for drawing of wires etc. as reqd. | 20 | Mtrs. | - | - |
| 1.1 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. | 10 | Mtrs. | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
TenderEISakrar.pdf
Tender Documents • 1.03 MB
BOQ_334175.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .