| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | ₹40.2 L | L1 | Accepted-AOC Being lowest tenderer after deducting Sch of Credit |
| 2 | L2₹43.3 L+₹3.1 L (7.77%)Rejected-Finance HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | ₹43.3 L+₹3.1 L (7.77%) | L2 | Rejected-Finance Being other than 2nd lowest tenderer after deducting Sch of Credit |
| 3 | L3₹53.9 L+₹13.7 L (34.1%)Rejected-Finance | ₹53.9 L+₹13.7 L (34.1%) | L3 | Rejected-Finance Being other than 3rdlowest tenderer after deducting Sch of Credit |
| 4 | L4₹69.5 L+₹29.3 L (72.8%)Rejected-Finance | ₹69.5 L+₹29.3 L (72.8%) | L4 | Rejected-Finance Being other than 4th lowest tenderer after deducting Sch of Credit |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
12 Feb 2024, 6:00 pmClosed
Shri Vishal Garg,IDSE ,SE (SAG)
CWE Chennai
SPL REPAIRS TO ROOF TREATMENT AND CONNECTED WORKS TO BLDG NO 456 OF OTA UNDER GE STM CHENNAI
2024_MES_636664_1
86542/E8(II)
Open Tender
Civil Works
Item Rate
150 days
GE ST THOMAS MOUNT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE STM Chennai
₹1.1 L
Yes
26 Feb 2024
10 Jan 2024
19 Feb 2024
10 Jan 2024
12 Feb 2024
24 Jan 2024
10 Jan 2024 - 17 Jan 2024
Amount
BOQ UPLOADED ON 10 Jan 2024
Removing the existing roof treatment of any description completely including padding concrete, Screed bed and removal of all the debris from the site and rubbish off the premises complete all as directed by the Eng-in-Charge
Roughening surfaces of old concrete flooring by picking, sweeping clean and washing down with water to remove dust etc, and brushing neat cement slurry with 3.0 kg of cement per Sqm
PCC 25mm thick (average thickness) 1:2:4 mix type B-0 (using 12.50mm graded aggregate) as in leveling course on roof surfaces complete all as specified and directed. Note: (i) Level sheet for the roof top will be maintained before carrying out any repair work duly approved by the GE.
Screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:3) over roof surface/ chajja etc finished even and smooth without using extra cement mixed with Water proofing compound complete all as specified Note : (i) Water proofing compound will be measured and paid seperately)
PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in roof kerbs rounded or chamfered on edges cills, coving, steps, seismic and similar bands, plinth courses, string courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and the like including platform for tanks, weathering, slightly rounded or chamfered angles and throating mixed with liquid wwater proofing compound as per manufacturer instruction including form work all as directed. (Note : Liquid water proofing compound will be measured and paid separately).
Supply only Liqid water proofing compound
Cutting grooves in brick wall, of size not more than 20mm wide and 65mm deep and shaping horizontal face of groove with CM 1:3 mixed with Liquid water proofing compond as per the Manufacturers Instructions.
Preparing the rendered surface thoroughly to remove all loose particles, dirt / dust particles and applying a uniform coat of blown grade bitumen VG-10 @ 1.20 kg/sqm conforming to IS-702 over a coat of bitumen primer @ 0.70 Litres / Sqm followed by 3mm thick weighing not less than 3.80 kg / sqm APP membrane reinforced with polyster non woven fabric HMHDPE matt black laid on primed surface by torch application complete all as specified and directed by the Eng-in-Charge. Note : (i) The make of the APP Membrane will be approved by the Accepting Officer along with the details of the authorised applicator of the manufacturer duly recommended by the GE
Hydraulically pressed burnt clay tile machine made of size 200 x 200 x 19/20 mm laid over screed bed 15mm thick in CM 1:6 jointed and pointed in CM 1:3 mixed with 5% crude oil by weight of cement complete all as per the manufacturers Instructions Note : (i) Sample of the Clay Tile along with complete details and manufacturers testing certificate will be submitted will be submitted to the Accepting Officer duly recommended by the GE for approval.
Disconnecting PVC tanks 500 litres capacity, setting aside (or lowering as required) for repairs, cleaning, etc., and hoisting if required reconnecting and refixing in position.
Ditto all as per Item No 11 above but 1000 Ltrs Capacity
Ditto all as per Item No 11 above but 2000 Ltrs Capacity
Taking up or down 25mm dia steel tubing and connections incl cleaning for refixing or removal from site
Taking up or down 50mm dia steel tubing and connections incl cleaning for refixing or removal from site
Refixing old steel tubing and connections of 25mm dia in new or old position (Walls, ceiling, floors, etc.) as directed by the Eng-in Charge
Ditto all as per Item No 16 above but 50mm dia steel tubing
PPR Polypropylene random copolymer) concealed pipes 50 mm outer dia 3-layer SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc in repairs complete all as specified and as directed Note : The quoted rate is inclusive of cutting chases or making holes in brick walls for concealed water tubing, making good to facings where required not exc 10 cm girth
All as per Item No 18 above but for 25mm bore fixed to walls, ceilings or laid in floors
Gun metal (Bronze) Gate, globe/Wheel Valve 50mm bore dia of pipes with Iron wheel head screwed both ends for iron pipe and fixed in repairs. Make - Kartar (K604) or equivalent of makes listed here-in-after.
All as per Item No 20 above but for 25 mm bore GI tubing
Ball valve PTMT with epoxy coated aluminimum rod for 25 mm bore pipe high pressure with polythelene high density float and complete screwed for iron pipe fixed in repair.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of bore 110mm as in repairs complete all as specified and as directed.
PVC SWR bend any radius 110 mm dia as in repairs complete all as specified and as directed Make - Prayag (Cat Pt No 5110/ 5111) or equivalent of makes listed here-in-after.
Dismantling of ceiling board of any thickness including aluminium snap grid/ cover fillets all spacified and as directed
GI frame work of (605 x 605) mm size grid for seamless ceiing comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to sorrounding wall using nylon sleeves and screws at 450mm centre to centre / intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and incl ceiling section of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete all as specified.
Non-asbestos fibre cement building boards 4mm thick fixed to GI framework with screws in ceiling fixed in jointless finish with jointing compound and jointing tape as per manufacturer instructions complete.
Preparing ceiling surface even and smooth by providing and applying plaster of paris 1mm thick and applying two coat of Oil bound distemper complete all as specified and directed by the Eng-In-Charge.
M&L for preparing of old painted wall surfaces and applying two coat of oil bound distember complete all as specified and directed by the Eng-In-Charge.
DJ Group
Kaadosh Real Estates Pvt Ltd
ASHWIN ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .